Getting to know your Solis Series 5 Hybrid (energy storage) Inverter.

Поделиться
HTML-код
  • Опубликовано: 13 сен 2024

Комментарии • 67

  • @alanrobinson1695
    @alanrobinson1695 Год назад +3

    Thanks Peter for the video - really helpful. You have a knack for explaining in a clear and understanding way. Just had my Solis inverter installed - I'm now confident to at least touch those buttons!! Hoping you will continue with more.

    • @SolisNotSolis
      @SolisNotSolis  Год назад +1

      Very welcome

    • @paultraynorbsc627
      @paultraynorbsc627 3 месяца назад

      Thanks for sharing with octopus
      Exporting More than using getting high bills clock time was out by one hour. Also switched to cheap charging for battery

  • @andrewpeat8710
    @andrewpeat8710 Год назад +1

    This a great little vid. Useful information on these inverters seems to be lacking on youtube.

  • @travissnyder9092
    @travissnyder9092 Год назад +2

    Peter you are amazing buddy. Really love your content and willingness to help.

  • @EMidMSO
    @EMidMSO Год назад +2

    Re Time settings. I don't know whether all energy companies are the same, but Octopus uses UTC, not local time, so be aware when setting the time on the inverter

  • @AnthonyFrancisJones
    @AnthonyFrancisJones Год назад +1

    Excellent - thanks for this. Just what I needed to know.

  • @TheKerb17
    @TheKerb17 Год назад +1

    Great video. Keep thd solis video's coming, there are Hardly any on RUclips

  • @martinweston8147
    @martinweston8147 Год назад +1

    Really like this channel, thanks Peter, would be great to have an overview of your full system and any pros and cons you have from your setup or it’s installation?

    • @SolisNotSolis
      @SolisNotSolis  Год назад +1

      Thanks Martin. I'll add it to the list!

  • @ps1budgerigarspaulstannard227
    @ps1budgerigarspaulstannard227 Год назад

    Thx Peter these videos you do are a great help

  • @HushListenLove
    @HushListenLove Год назад

    Hi Peter, great video thank you, my inverter and batteries don't seem to be on at all, I've just moved in and had broadband connected which goes into the data logger but I'm a complete beginner with solar and no idea what to do and if it's all broken!

  • @johnduddy4136
    @johnduddy4136 Год назад +1

    Thanks for the informative video!

  • @Jamescolbert182
    @Jamescolbert182 Год назад

    Please keep these videos coming to a novice this stuff is so useful. I think most people will want a video on the below if you could make one?
    I just want to use all the energy, any spare sent to batterys and then anything else sent to grid. I think this is Self-Use mode but do I need to set up discharge timings etc?

    • @SolisNotSolis
      @SolisNotSolis  Год назад +2

      Hi James. Thanks for the kind words.
      Self use mode does exactly what you describe.
      PV supports house load, then if surplus
      Charges Batteries then if they're full
      Exports (unless configured not to)
      You do not need anything on the Time of Use screen (with charge/discharge) timebands to perform this. Indeed you'd be better with that screen set to Stop.
      Charge fields on the time of use screen are for forcing battery charging from the grid, and conversley the discharge fields are to force your inverter to dump the contents of your batteries back to the grid (if you were being paid a super premium export rate you might choose to tip all your stored energy back for example).

  • @atoma1972
    @atoma1972 Год назад

    Hi Peter. Thank you for your share. Helpful tutorial! From your video I can see in all screens when the first diagram si visible that the consumtion of your house is lower aproximatly ~100-130w than the input power from PV and from the battery. This is the power consumtion of the inverter for self use?

  • @alihart
    @alihart Год назад +1

    Hi Peter - these are great tutorials and so helpful for (absolute) beginners like me. Many thanks, consider yourself subscribed to 😉

  • @SteveRossiter-ns8hs
    @SteveRossiter-ns8hs Год назад

    Hi Peter, I have just installed a Solis Hybrid inverter and three US3000c batteries. Your channel has been very helpful in getting it up and running. The solar panels should be ready to connect in a couple of months when I finish building my shed. One issue that I have is that my inverter consumes around 150w 24 hours a day which seems a huge amount of energy. When I look at the screen on your inverter it seems that your inverter is consuming around the same. Is this correct? This doesn't seem to reflect the stated 98% efficiency.

  • @wassaufkhalid8593
    @wassaufkhalid8593 Месяц назад

    We have a hybrid 6kw solis inveter and a volt protector device attached before it. The voltage protector show 2 to 2.5 amp import from grid while the inverter app shows that grid is not being used and power is only coming from solar. What is the problem?

  • @leewatson6959
    @leewatson6959 Год назад

    another sub here Peter, great easy to understand Info. do you know where I can find out more info about the app and what the values mean?, I have a similar set up to you, two lots of panels plus battery, I also charge on a cheap night rate. what i dont understand it my current yield is 1.5kwh but it says my generation is 5.08kwh. I imagine it has something to do with the battery but im struggling. it would be great if you have the time to make a video explaining some basic info on the values on the app, if you use it that is. cheers

  • @StevenVacher
    @StevenVacher Год назад +1

    Another great video, these videos should be standard viewing for anyone who has recently had a Solis inverter fitted.
    A question, I have 3 Pylontech US2000C batteries for 7.2kWh of storage but mine show that the Charge Limit is 75.0A, is this an error with the inverter, batteries or install.
    Thanks. Keep up the great videos.

    • @SolisNotSolis
      @SolisNotSolis  Год назад

      That is the correct value sir. US2000C are 25A sustained charge/discharge rate each.

    • @StevenVacher
      @StevenVacher Год назад

      @@SolisNotSolis Superb, thanks very much for the quick response and great video series.

  • @Gigidurucuru
    @Gigidurucuru Год назад

    Hi Peter. Very good videos. I subscribed to your chanel.
    Any particulat settings I should have for 2 X 5KWh LPF 48100 R batteries in terms of storage? I selected DLG, was wondeing if I sould customise that at all.
    I am also using cheaper tarrifs at night to charge my batteries during winter. For me setting the charge amp to 30 works.
    Thanks for your help.

  • @buddysalvador7416
    @buddysalvador7416 2 месяца назад

    Hi please how to get in to reserve soc i cant find it in the storage set do i need to download solis cloud?

  • @wkxy2002
    @wkxy2002 5 месяцев назад

    Mi scusi ho 2 batterie us3000c ma non è stato settato nessuna batteria come master può influire?. Grazie ho un inverter della solis da 5kw per le info del bms ho il cavo sulla porta a/can

  • @thomasengel9802
    @thomasengel9802 11 месяцев назад +1

    is it possible to use this as an stand alone ess in comnbination with an already existing solar inverter?

    • @SolisNotSolis
      @SolisNotSolis  11 месяцев назад

      Hi. It is indeed. It will charge with any surplus the management CT sees. So as long as that is at the edge of your house ie under your utility meter and the existing PV is inside it, it will happy use the surplus to charge. No config needed. Its the out of box setup for self use mode.

  • @MichaelWhite-yf6zk
    @MichaelWhite-yf6zk Год назад

    Hi Peter can you change the value of import and export values to your own suppliers. Great videos,keep them coming. Thanks

    • @SolisNotSolis
      @SolisNotSolis  Год назад

      Hiya Michael. Are you referring to the section on the phone app where it shows Octopus?
      PS thank you! I've a bunch planned for this weekend.

  • @dougdawson3118
    @dougdawson3118 Год назад +1

    Thanks for the video. My Solis inverter has an additional symbol on the main display screen showing output from the inverter going to a lightbulb, do you know what this means? Your inverter doesn't show this and I can't find any information about it.

    • @DSB_
      @DSB_ Год назад

      A lightbulb icon with 4 sparks coming from the top? From my Solis manual: Critical Loads: Loads connected to the AC Backup port which will
      be supported by battery and solar even if the grid is in malfunction.

    • @dougdawson3118
      @dougdawson3118 Год назад

      @@DSB_ Thanks, yes that's the icon I mean. That explains it.

  • @HanKila
    @HanKila Год назад +1

    Hi Thanks for this video. I have a similar setup as you. Can i add a second inverter with a second solar array and have it work with this inverter and batteries? how would i connect it?

    • @SolisNotSolis
      @SolisNotSolis  Год назад

      Hi. You can indeed. The AC charger is bi-directional on a Solis. So install a second string inverter + panels, and any surplus (as in export to the grid) from the second install is seen as surplus via the Solis meter/CT combo and used to charge the batteries on the hybrid. No interlinking/cabling/config required. Literally install the second (none battery) system as if the first wasn't there and it will work perfectly.
      You would of course need DNO approval for the additonal potential export capacity first.

  • @stevecooke1636
    @stevecooke1636 5 месяцев назад

    Is there any way to access the settings shown in these videos other than by going directly to the inverter control panel - e.g. a web page - and avoid climbing into a loft? The basic web page I can see on my system only allows very basic setting changes such as WiFi connections and server addresses - is there also a URL that would give access to the more advanced functions? Thanks

    • @SolisNotSolis
      @SolisNotSolis  5 месяцев назад +1

      Hi. Yes. Both.
      Assuming you've requested remote management permissions, under the Device, three dots top right of the screen on both the web interface and the phone/tablet app.

  • @celiarushin1729
    @celiarushin1729 Год назад

    Hi Peter,
    Thanks for the video, we had our battery installed on sat. The weather has been rubbish since, and according to our app, we have produced no power. We are on economy 7 and asked the installer t to set up the times for the battery to charge in the cheap period overnight. But it's doing it at prime time. Please can you explain how we change it.
    Many thanks Ceil

    • @SolisNotSolis
      @SolisNotSolis  Год назад

      Hi Celia. I aren't surprised you've made little to nothing from solar. I'm just the same. There's something there, but it's barely countable.
      I've put together a video on that already for you!
      Take a look here, and if you've any questions, just shout!
      ruclips.net/video/h1A80cSOrhA/видео.html

  • @drunknspike
    @drunknspike Год назад

    I'm wanting to buy this inverter SOLIS RHI-5K-48ES-5G 5KW HYBRID SOLAR INVERTER inverter work off grid for a home office garden shed and use mains power as a back up if the batteries connected or the solar pannels have low input power to charge the battery's and use appliances at the same time will it work thanx in advance

  • @rukshansanjeewa7533
    @rukshansanjeewa7533 Год назад

    If i wont to stop export an use PV power and battery for the house and if both not enough if grid can supply power what is the setting that i have to use

    • @SolisNotSolis
      @SolisNotSolis  Год назад

      That is the default - Self Use Mode.
      Ensure all other modes are specifically disabled, as enabling self use doesn't automatically turn all the others off.

  • @gmobeybill
    @gmobeybill 3 месяца назад

    Hi Pk on Solis, can help me to understand why will electric usage skyrocketed soon as I put on my storage battery and keeps charging at anytime even when I have set up charge time to be 2 am till 4 am.

    • @SolisNotSolis
      @SolisNotSolis  3 месяца назад

      Most commonly it is because the monitoring CT is either on the wrong cable (i.e. not under the supply meter and has been installed under the inverter or only on the household consumer unit when it also needs to see the (separate) PV board). Or it's facing the wrong way around on the cable it's attached to.

  • @RogerWebb-yx9jg
    @RogerWebb-yx9jg Год назад

    Hi, Newbi here and ask a silly question time. Just had a 50Kw solar PV system installed with a Solis Inverter. As it is a commercial use property I have not invested in any battery storage yet as there is minimal power demand after about 6pm. What size battery storage should i be looking at given that the solar energy is providing most of the demand, well on sunny days anyway

    • @persona250
      @persona250 Год назад

      Hi roger , is it a hybrid inverter ?

  • @daughydoc
    @daughydoc Год назад

    Hi Peter, great videos, is it possible for you to do a video on setting the backflow power, if I turn it off my battery's recharge at the full rate of the solar panels, but after they recharge nothing goes back to the grid and the panels stop producing, if I turn it on and set it to the amount the inverter can send back to the grid it will recharge the battery at a low rate and send excess back, I have an Eddie diverter so I need to find the right balance.

    • @chrispotts969
      @chrispotts969 Год назад +1

      I have the exact same problem daughy doc. When batteries are fully charged, the solar panels start clipping down to nothing in full sun. I would like the excess to go back to the grid, but obviously not from my batteries. Hope Peter can help us out.

    • @daughydoc
      @daughydoc Год назад

      @@chrispotts969 While testing the other day, I found that I could limit the amount the percentage of the battery drained to.
      My 2, 5kwh batteries are in parallel so I had issues with them communicating with eachother, there generic bms, not the standard solis batteries.
      My issue was one battery pulled power from the other leaving it at 0%.
      Switching the master to slave and slave to master seemed to have fixed the issue and they're now in sync. For how long I don't know, I set the inverter to drain to 50% capacity only, and set the over discharge to 40%.. these are the maximum allowed settings, I set the force charge to 40% at 25amps and when the batteries hit 40% discharge, the power was coming from grid only...
      This isn't ideal for everyone but the 20% discharge wasn't kicking in and it was leaving my second battery drained from powering my other one.. I set the backflow power to off, and have left it at 100 watts, as the weather is terrible, but that will change in summer.. not sure why this inverter isn't playing ball

    • @SolisNotSolis
      @SolisNotSolis  Год назад

      Hi. I covered off "backflow" or export power management recently. Hope it helps.
      ruclips.net/video/1aFcX0OYyXc/видео.html

    • @SolisNotSolis
      @SolisNotSolis  Год назад

      Hi. I covered off "backflow" or export power management recently. Hope it helps.
      ruclips.net/video/1aFcX0OYyXc/видео.html

  • @lalakakakaka
    @lalakakakaka Год назад

    Hi Peter, great videos. Just a quick question if you may. I have x2 Pylontech 2000cs and have just got a Pylontech 5000c which is now the master. I have currently, with Octopus Flux Import were cheap to import at 2am-5am, and great export rate between 4-7pm. With the Pylontech 5000c S the master but 2000cs in the chain can I increase the discharge limit from current 50A(maximum
    2000s can do), to say between 60-80A?(5000 as you say can do 100A discharge) if you are anyone in this thread knows it would be appreciated!!!

    • @SolisNotSolis
      @SolisNotSolis  Год назад

      Hi. Which model of hybrid do you have? Assuming its a 4.6/5/6kW model then yes the sustained rate of 80a is comfortable. You can peak to 100a but it won't sustain that for hours on end.

  • @chrissalisbury7826
    @chrissalisbury7826 4 месяца назад

    Can you set it up to charge at night of EV tariffs and charger day via solar panels?

    • @SolisNotSolis
      @SolisNotSolis  4 месяца назад +1

      Hi. It will charge batts from solar by default in Self Use mode during the day.
      If you check my other videos there's a couple on overnight charging from the grid which you can set to your cheap energy timeslot.

    • @chrissalisbury7826
      @chrissalisbury7826 4 месяца назад

      @@SolisNotSolis thanks

  • @paulbuxton8035
    @paulbuxton8035 Год назад

    Is that the RHi or S5 inverter?

  • @smartazz
    @smartazz Год назад

    Thanks for this video. I currently have my grid status saying off grid mode. I see yours is Normal mode. How can I change this please.

    • @SolisNotSolis
      @SolisNotSolis  Год назад +1

      If you have a look at the first part of this video, here are some details on checking/changing to Self Use.
      ruclips.net/video/h1A80cSOrhA/видео.html

    • @smartazz
      @smartazz Год назад

      Thank you for help it’s sorted now

  • @brutdesign4721
    @brutdesign4721 11 месяцев назад

    HELLO i wanted to setup without grid (off grid) so i don t conect rs485 , my diy battery (16 lifepod 280 ah 48 v) with jk bms but not can
    i don t understood if a setup battery on lead battery or other i alwas have alarm ... if i setup no battery no alarm ... could you help me thanks

    • @SolisNotSolis
      @SolisNotSolis  11 месяцев назад

      Hi. Thanks for the comment. Unfortuntely it's not a setup I'm familiar with so can't really help on this one.
      There are two Solis Facebook pages which might be a better bet, or the DIY Solar project page is also popular. They maybe able to help.

  • @ruwankumara6226
    @ruwankumara6226 8 месяцев назад

    Does it work with Growatt Hope 4.8L-C1 battery?

    • @SolisNotSolis
      @SolisNotSolis  8 месяцев назад

      It's not on the approved battery list so won't work fully managed. But might be possible to run as an unmanaged storage battery