Staggering of Bar and Lapping Zone problem in Building Construction I Know Solution as per IS Code

Поделиться
HTML-код
  • Опубликовано: 16 ноя 2022
  • Staggering of Bar and Lapping Zone problem in Building Construction I Know Solution as per IS Code
    Know More: contechxs.com/rebar-coupler/
    Phone: 9549549543
    Email: 9549549543@contechxs.com
    Welding, Lapping, Coupling of Reinforcement in Column and Slab - Which is Best
    • Welding, Lapping, Coup...
    What To do if Lap in Column Comes in Zone A
    • What To do if Lap in ...
    Which Bar should be Staggered during lapping in Column? | Upper or Lower
    • Which Bar should be JO...
    Reinforcement lapping Zone as per IS Code 13920 in Column
    • Reinforcement lapping ...
    Staggering of bar and lapping zone problem in building construction: stagger every bar with rebar coupler is the solution
    #Lapping #Coupler #staggering
    Disclaimer - This video is for educational purposes only. Copyright Disclaimer under section 107 of the copyright act1976, allowance is made for "fair use" for purposes such as criticism, comment, news reporting, teaching, scholarship and research. Fair use is a use permitted by copyright statute that might otherwise be infringing. Non-profit educational or personal use tips the balance in favour of fair use.

Комментарии • 26

  • @parvindra29

    Use full this video is solved my problem and confusion

  • @vishaljaiswal1440
    @vishaljaiswal1440 Год назад +4

    Sir app please video banaya kijiya jaldi hum log ko bahut intzar rehata hai❤️❤️

  • @sailendranathvemulapati

    If the length of the column rod left for the higher floor is less where we cannot lap it sufficiently, how can a coupler be used?. The existing rod cannot be threaded.

  • @vishalsharma2290
    @vishalsharma2290 Год назад +1

    Hello sir...

  • @subhankardua7112
    @subhankardua7112 Год назад +2

    Sir,non structure wall me q vertical ko floor to floor hota hay usko age Tak q nahi leta hay

  • @anandkumar5260
    @anandkumar5260 Год назад +1

    सर नमस्कार अगर छत के ऊपर स्लैब में सभी एक समान छड़ कट गए हैं तो क्या उसको वहीं पर कौपलर देकर कॉलम दूसरी मंजिल के लिए उठा सकते हैं क्या बताने का कष्ट करेंगे क्या पूरे छत पर बीम देकर कॉलम उठाया जा सकता है

  • @maheshj660
    @maheshj660 Год назад

    Agar site par column mein lower floor par 20mm dia vertical rebar hai , aur upper floor par 25mm dia hota (lower to higher dia) hai then us case mein couple kaise kaam aayega please explain , muze konsa rebar kaha terminate karna hoga aur kaha se jodna hoga

  • @cgogoi8952
    @cgogoi8952 Год назад

    Kya ground floor ma hi column ka joint da sakta haa. Kya ya safe haa

  • @amols9634
    @amols9634 Год назад +1

    Coupler Lagane k liea jo thread bnate h us se to steel ka strength Kam ho jata h na sir

  • @sabyasachipal4991
    @sabyasachipal4991 Год назад

    Sir,

  • @siddhartsrivastava2883
    @siddhartsrivastava2883 Год назад

    3 मंजिल बिल्डिंग के लिए फाउंडेशन से सरिया को कितनी ऊंचाई तक पहले बार काटते हैं यदि फाउन्डेशन से प्लिंथ बीम 10 फीट हो और उसके बाद छत 11.50 फीट हाइट हो तो पहला लैपिंग कितने हाइट पर रखेगे

  • @kirankumarsa4555
    @kirankumarsa4555 Год назад +1

    Sir.. my question is in building surveying .. which are the level that surveyor give... for example columns points sill level like that in total building that surveyor give every levels in building Construction am waiting for u r answer...

  • @homeplan3532
    @homeplan3532 Год назад

    Sir mein house construction karwa raha hoon mujhe column mein problem ho Rahi hai aap meri help kar sakte hai

  • @Perfectvlog74

    Agar 4 rod ek jaga pe laping pare toh Kia karna cahiyea ?

  • @haqi76
    @haqi76 Год назад +1

    16 mm aur 20 mm bar mau coupler ya but weld use kr saktay hain

  • @digitalatoz.
    @digitalatoz. Год назад

    Hello I'm BabulT from Dhaka,Bangladesh. However can you help me please I've need details for couple's purpose.

  • @homeplan3532
    @homeplan3532 Год назад

    Practically sariye ka wastage na ho isliye sariye ko ek hi length rakh dete hai Jayda tar log

  • @ironman2600
    @ironman2600 Год назад +1

    Sir Coupler For 16 mm Bar Kahan Milega ??