Reinforcement lapping Zone as per IS Code 13920 in Column | Learning Civil Technology
HTML-код
- Опубликовано: 22 дек 2019
- ✔In case of any confusion, feel free to message me on Facebook:
/ learningciviltechnology
✔New Channel Link: House Construction free Support
/ @cemukeshsah
JOIN US ON
✔Instagram: / learningciviltechnology
✔Whatsapp: chat.whatsapp.com/KLl7CHaxTMi...
✔Facebook: / learningciviltechnology
✔Telegram: t.me/LearningCivilTechnology
✔Pinterest: / learningciviltechnology
✔Email Id for Business Enquiry - civilengineeringofficial@gmail.com
✔Linkedin: / civilengineermukeshsah
In this video, I will explain,
1. Reinforcement lapping Zone as per IS Code 13920 in Column
2. What is the reason behind this?
3. What is Reinforcement Lapping?
4. What is the function of Reinforcement lapping?
5. Bending Moment Diagram of Column
⓿My Playlist Link
✔HOW TO STUDY DRAWING
• How To Study Drawing
✔CIVIL INTERVIEW
• Interview
✔CHECKLIST OF CIVIL WORKS
• Checklist of Civil Works
✔BBS (BAR BENDING SCHEDULE)
• BBS (Bar Bending Sched...
✔QUANTITY ESTIMATE
• Quantity Estimate
✔CONCRETE VOLUME CALCULATION
• Concrete Volume
✔IS CODE LECTURE
• IS CODE LECTURE
✔DREAM HOUSE CONSTRUCTION SERIES
• DREAM HOUSE CONSTRUCTI...
✔HOUSE CONSTRUCTION
• House Construction
✔HOUSE PLAN
• House Plan
✔CIVIL EXPERIMENTS
• Experiment
✔SURVEYING
• Surveying
✔CIVIL ENGINEERING TALK
• Civil Engineering Talk
****************************************************************
Official Website in English: www.learningtechnologyofficia...
Official Website in Hindi: www.civilofficial.com
****************************************************************
#CivilEngineerMukeshSah #ReinforcementLappinginColumn #LapinRCCColumn #LappingZoneinColumn ReinforcementLappingZone #CivilEngineeringVideos #LearningTechnology #L&T-LearningTechnology
Video ko Daba ke Share karo bhailog aur apna pyar dikhau.. Taki hamare sabhi bhahiyo, hamare Juniors aur Engineers tak pahuch sake.
Sir plinth beam top se floor beam bottom hight hi length hoga kya
I like ur videos more than other's videos.....
Sir middle zone me to bending moment kam hota he na tabbi ties ki spacing ku kam rkhte he
Also make video on staircase. As most of the people get confused while calculating treads and risers on actual site. Most important is staircase which is starting from some random floor. Which is not in continuation.
Sir aapka video dekhne ke bad pura tarah se satisfied ho jata hu bhagwan aap ko aise aur mind ko clear rakhe 👏
Sir I'm form Bangladesh,You are my very good teacher.Your explanation is very good sir.
Thank you so much,keep your update your video.
Sir I am Engineer but I can't explain as you explain. Thanks sir 🙏
👍👍# good lap zone in column #
Thanks For Teaching Sir
Also make video on beam and slab for overlapping
Thank you very much for the practical knowledge on Lapping Zone in column.
It is increasing our knowledge and confident in real time environment in site.
I have one question regarding column.
What could be the solution if the length of the reinforcement from isolate foundation is not enough for Lapping which should be provided for second or next story of building ?
Thank you and Regards!
Shailesh Singh.
Nepal
Excellent sir
Beam lap also required .
Thank you soo much.
#Beam zone required. Beautifully explained.
knowledgeable video sir 👌👍
Thank You Sir
Mukesh ji I like you for good teachings
I have downloaded your IS Code app.You have done a fab job brother.
Bro ur teaching is damn good
👍🏻 Keep it up
Tnx for clearing my concept
u r so good person! ❣️
Allah bls you
Thank you for your support
Very good video
Share and Keep Learning
Excellent sir.. 👍👍👍🙏🙏🙏🙏
अच्छा.व्हिडीओ.धन्यवाद.सर.
your explaination is very good
Hats of to you sir...
Good and informative video. Thanks!
Bahat achhaa!
Good job 👌
Superb video sir.
#Beam and Slab lap zone
Thank a lot sir
Absolutely sir
Thank u sir
NYC videos about lap zone
Thanks for Ur valuable information. I want to know one information, what is the joggle length and its ratio of the lapping bar as per the code reference.
Will make video on it
nice information , take a example of floor to floor ht 4 m , and give detail of lapping and lap length for footing to coloum , and above
Your my Guruji
Well explained
Auto level pe video banao sir....
PLEASE MAKE A VIDEO ON LEVEL OF. SLAB. ( SLAB ka level kaise check krte hai before casting)
Lap joint in beam as per is13920 2016
Thank you sir.....ur valuable information.sir i want to know that about bbs.
Excellent sir. Please sir still ki quantity nikalna batao. Kaise still ki quantity ko nikale total slab, beam, coloum etc.
Very Good Follower Base. Good Luck. #Success555
Sir I have one doubt about feture extension of building we leave 1 height of steel for feture extension but that is not a lap zone.then what we do for that for over come that problem
Bhut gazab sir Plz Do some Thing for compitative exam
Very nice👌👌👌
from the edge of the bottom or the top of the slab into the column, what shall be the minimum distance to provide the ties.
Kindly make a video on accelerator and retarders, plasticizers and superplasticizers
Sir , now column height is 2.5m and stirrups spacing is 150mm. This data’s are given as per drawing ..L/6 area it has less spacing .I what spacing should use here (L/6)
Very nice sir .make vedio also beam ,slab lapping
Plz make a video on importance of primavera p6
#beam pl. Sir bnao, and also explain how to decide L lenght of primary & secondary beam at end of beam.
Its very good vidio. Please make vidio on mivan Constructions steel.
Sir while calculating L beam depth should minus or not
Sir me assam se hu . mera building me column ka 6 sariya me 4 ko job join kiya tha usme laping kiya baki bij ka 2 me laping kiya nahi .kiya kharab hoga kiya .abhi me groun floor banaya he .
In addition to that minimum clear vertical distance between lapped bars shall be 0.25 times lap length. What is this?
Please make videos on RE wall highway
Sir colomn ki clear length beam bottom se Lena hai ya slab bottom se ? Kyoki beam bottom , slab bottom se down hi hoga
Hi mukesh... i have a question. Between both the lapping zone how much should be the spacing? I mean 50% rebars to be lapped below centerline and 50%above centerline. Should there be any gap between these staggered bars?
Mukesh ji only column beam junction mai actually minimum numbers of ring set kitne provide krne chahiye as per which is code
Also make a video on water proofing of terrace. What are the best materials present for it in the market.
already made a video on waterproofing of terrace..few days back... check my videos
@@LearningCivilTechnology yeah sure...Great 🙂
Thank you for this video.pls make a video on beam lap required.👍
Good sagsion
Nice sir
Thank u dimpal ji
# plz tell about cutting length of steel from foundation so that we can avoid zone A for floor height 3mtr..❤
Hello sir..
Yaha lap ham upar se jo joint karenge us steel me dena hai ya niche wala me.
Sir ; Bridge pier or abutment will be same Lapping zone
Sir clear span for lap in column is from beam bottom or slab bottom please tell me from where we take l/4 length please explain sir
From soffit of beam
Mukesh tum yaha ho..Mai Kabse dhund rha tha
Very nice app
waterpoofing mixing details at buildings prepare one video sir.....
Column ki laping beam wale porsen me kr sakte h
Sir, our engineer has placed lapping zone in column beam junction, already centering is done , waiting for slab,what shall I do now, engineer says it is ok for 2stor house,sir kindly suggest what should I do
Is it still intact ?
Slab beam ke Ander column r/f ka lap de sakte h kya
Agar zone B me bars ko starting karni padi to kya karenge. How it possible with overlap?
Sir plz bta dain stagger kB provide krte hai raft me
Lapping lower dia ya higher dia interview Questions?
What happen if the lapping given by welded ? Kindly make a vedio about why engengeers do not let welding any rebar joint in the building design ? Please let me know ! ?
Lapping dete hue and bante hue bhi dikhayen field mai taki samjhna asan ho
Sir, I want to know that.... Ki sariya ka dia Or quantity saman hona chahiye ya nanhi..... 1000sq building ka sab Callum ka
Sir splice mai jo ties provide krte hai uska spacing kitna hota hai ???
16mm bar 45d kar k kat diya hun... isku over lapping dene se koi problem hoga????
#beam zone required
Pls explain abt shear wall bro
What type of joggle,joggle methologi, IS code standard interview Question?
Jab ham clear cover ki baat karte hain to beam ya column dono cases me yah clarify Karen ki langitudinal bar ke outer face se clear cover consider Karen ya stirrups/ ties ke outer face se.Thanks
Beam ke leye bhi video bana degeye
Ok
Beam lap required Sir ji
Total station operation video banaye sir G
#parapet part, column extend wat height we should leave for further construction and lapping on it, tag mee bro when u upload
Sir all about pile foundation plzzzz!
ok
Sir it’s not available in App Store .. I could not find .. pls help
Jab column k vertical bar k dia change hota hai tab humko kakha lapping dalna hai?????
Matlab 2nd floor k bad mera steel k dia change hone wala hai..tab konsi jaiga par lap dalna hai?????
lap always zone B
I know the lap provides always zone B...But
How it's possible when my dia of bar change in 2nd floor...!!!so how can i extend the bar B zone in 3rd floor...!!!
@@debasisghosh6697 please clear you Quotation I think for example 3rd floor par dia 20 hone wala hai aur 2nd par 25mm hai. To 25mm ka bar 3rd floor par zone B ke center tak jayega. Aap kehna chahte ho ki me steel 3rd floor par 25mm kyon du.
🙏 🇮🇳 👍 😍 #beamlap required
# beam lap explain please sir
Sir Column ko jab overlapping krte hai tab L/4 rule ke liye column ka total height ground se count hoga ya floor to slab? Please
Floor top to beam bottom
Please make a video on Beam and shear wall according to IS 13920:2016. IS-13920:2016 is very jumbled and difficult to understand.
Sir please confirm thi, bar dia 25mm hai, uska lap zyada hai, ab lap ka kuch portion plinth beams me ja rha ha, tou kya ye possible hai ke hum uper jo columns uthayengy unko plinth se lap krkey utha len? Please confirm this sir thankyou so much
G+2 ke liye column, beam or plinth Ka kya size rkhe
Any change in lapping zone if couplers are used?
No
@@LearningCivilTechnology I can't find Section 7.2.3 (in the copy of the IS code I have) to understand transverse reinforcement as mentioned in Fig 12. Please give me a link to the right version of the IS code.
# Beam lap required sir
Good sir , Aapne a kaha tha,according to grade of steel and grade of concrete lapping provide karni hy toh wo bhi bataaiye k kounsa grade of steel & concrete se lap kaisa provide karte hy.
Sir reply diyo na video banaayenge na ?
Yes sir ye bata degeye
Drawing mey diya hota hey nahi to yaad kar saktey ho
Bro,in lap zone do we used 45D