  • In the video I diagnosed and replaced a bad harvest valve on a Manitowoc ice machine.
    If you found this video helpful please consider supporting the channel on Patreon.
    www.patreon.com/Icemachine411...

Комментарии • 108

  • @bugbomb8048
    @bugbomb8048 23 дня назад +2

    I’ve been battling with a 20 yr old large Manitowoc ice machine for two yrs…. I’m almost sure it a harvest valve now…. Great video thank you for the education….!

    • @IceMachine411
      @IceMachine411  21 день назад

      Pretty cool that you have a machine that’s 20 years old and is still working.

    • @AMELIAROTHSCHILD
      @AMELIAROTHSCHILD 16 дней назад

      lol same, q series! Gave it a little knock and, wallah! Harvested ice😅

  • @emanuelvelasco9042
    @emanuelvelasco9042 8 дней назад +1

    Im about to do this same job today. Awesome video, I will try removing the line. that's a good idea. Thanks for the video

  • @Jrod7291
    @Jrod7291 2 месяца назад +2

    You are a blessing to the ice machine techs 😅

    • @IceMachine411
      @IceMachine411  2 месяца назад

      Huge compliment. Thank you for that.

  • @sherwinalvarez7365
    @sherwinalvarez7365 5 месяцев назад +3

    I for one got great value off of this video. Sometimes simple is best. That being said, when you unsweat those 2 joints just made me feel a little foolish for all of the time i have struggled to do exactly what you talked about. I mean i do it with evaporators on units but never thought to do this on an ice machine. Im loving your videos. Im telling all my guys from school and work about you. We need your numbers up.

    • @IceMachine411
      @IceMachine411  5 месяцев назад

      I really appreciate you. Your comments mean a lot. I’m glad these videos have helped you.

  • @AVR-hf1rl
    @AVR-hf1rl 8 месяцев назад +3

    Learn something new every day Thanks for the video

  • @noahyohn2790
    @noahyohn2790 7 месяцев назад +1

    Literally had this same issue today. Repairing it Tuesday. great video! Was very helpful

    • @IceMachine411
      @IceMachine411  7 месяцев назад +1

      Enjoy your 3 days off brother.

  • @tiorontoron7531
    @tiorontoron7531 8 месяцев назад +4

    this is basically magic

  • @zekenzy6486
    @zekenzy6486 Месяц назад +1

    Great video. Thank you for sharing

  • @MrJEEPJT
    @MrJEEPJT 8 месяцев назад

    Great video 👍 !!over many years of moderate calls on ice machines the vast majority of the Manitowoc’s I’ve worked on have been water side problems, the occasional refrigerant leak, the occasional bad water pump.

    • @IceMachine411
      @IceMachine411  8 месяцев назад

      Same here. Most calls are water related.

  • @jerkyjohnny
    @jerkyjohnny 8 месяцев назад +2

    Great info and explanation! Thanks Jeff! 🧊

    • @IceMachine411
      @IceMachine411  8 месяцев назад

      Thank you for diagnosing it ahead of time John!

  • @skpsnipers834
    @skpsnipers834 3 месяца назад +1

    Appreciate your tip, smacking it with a screw driver really works to unstick them during testing🤣

    • @IceMachine411
      @IceMachine411  3 месяца назад

      Yes and it’s a good way to know for sure that it’s a bad harvest valve.

  • @trinito97
    @trinito97 27 дней назад +1

    Great video thanks

  • @gnpful
    @gnpful 7 месяцев назад

    Congrats 🎉
    Honestly man that’s a great job

  • @aaronpantoja2251
    @aaronpantoja2251 7 месяцев назад

    I started dancing when la chona song came on 😂. Just stumbled on your page I’m definitely subbing

    • @IceMachine411
      @IceMachine411  7 месяцев назад +1

      lol. Not super familiar with La Chona. Working in taquerias around Sacramento exposes me to la Raza.

  • @garza7676
    @garza7676 7 месяцев назад +1

    . No pressure like have Los tocunas de Norte on blast playing in the background while you braze .Good call on removing the whole line and brazing off equipment. I have a neo under the counter with this same harvest issue . Ice won’t come off evaporator .

    • @IceMachine411
      @IceMachine411  7 месяцев назад

      I wish someone would explain the significance of the music playing in the background.
      Also those Neo ice machines have had a rough run of bad harvest valves.

    • @garza7676
      @garza7676 7 месяцев назад

      @@IceMachine411 I work on residential hvac but would love to get into working on ice machines . Good thing I came across your channel . I already seen so many useful tips .

  • @charlesrios8542
    @charlesrios8542 8 месяцев назад +1

    Best one yet

  • @shine-cg9uf
    @shine-cg9uf 8 месяцев назад +2

    👍💪❄️🇺🇸 great informative video thanks for sharing

  • @mosadhana5815
    @mosadhana5815 7 месяцев назад

    Thanks for sharing!! Outstanding.

  • @user-de2oj6nb5y
    @user-de2oj6nb5y 4 месяца назад +1

    You doing great.

  • @keovongvilaykeo4799
    @keovongvilaykeo4799 8 месяцев назад +1

    Thanks 🙏 you for sharing

  • @raviyadav8743
    @raviyadav8743 5 месяцев назад

    Great job 😮

    • @IceMachine411
      @IceMachine411  5 месяцев назад

      Thank you. Hope you got some value out of this video.

  • @gnpful
    @gnpful 7 месяцев назад

    Great job 👏

  • @derrickgarcia303
    @derrickgarcia303 7 месяцев назад +1

    Good content!

  • @MauricioHernandez-if1mj
    @MauricioHernandez-if1mj 7 месяцев назад +1

    Thank you .

  • @ultimaterocketleaguehighli3772
    @ultimaterocketleaguehighli3772 3 месяца назад +1

    Great video dude

    • @IceMachine411
      @IceMachine411  3 месяца назад

      Thanks. Hope it helped.

    • @ultimaterocketleaguehighli3772
      @ultimaterocketleaguehighli3772 3 месяца назад

      It did I gave my harvest valve some percussive maintenance and it started giving me 1.5 minutes harvests. I did not replace it bc I’m not a beast like you. If it acts up again I will.

    • @IceMachine411
      @IceMachine411  3 месяца назад

      lol. Nice. 👍

    • @ultimaterocketleaguehighli3772
      @ultimaterocketleaguehighli3772 2 месяца назад

      @@IceMachine411yup and now I’m back… watched again.

  • @globecomputers1
    @globecomputers1 7 месяцев назад

    Awesome information.

    • @IceMachine411
      @IceMachine411  7 месяцев назад +1

      Thank you.

    • @globecomputers1
      @globecomputers1 7 месяцев назад

      I’m starting out in this field and even though there are others putting content yours is easier to understand.
      Can’t wait for the next episode! 👍👍👍

  • @camilo8cheryl
    @camilo8cheryl Месяц назад +1

    What kind of witchcraft is that?😂 you absolutely did some majic👍

    • @IceMachine411
      @IceMachine411  Месяц назад +1

      Abra kadbra. Ha. Welding copper to stainless steel is tough. I’m not skilled enough to weld it in place. One day though….

    • @camilo8cheryl
      @camilo8cheryl 29 дней назад

      @@IceMachine411 as muford majic words.. a la peanut butter and sandwiches.. poof!🌈💥

  • @eliseoalcala2976
    @eliseoalcala2976 6 месяцев назад

    Awesome 👍

  • @syakirinkirin5105
    @syakirinkirin5105 7 месяцев назад

    Tq sir.

  • @MightyMeehow
    @MightyMeehow 7 месяцев назад +1

    So I've found a bad HGV on their new style UC unit (the one where the bin removes off the refrigeration circuit) first time I diagnosed one and it would actually get stuck open! So never made a batch of proper ice. I used a solenoid magnet to exercise the valve but had no success. Never got to go back to replace it, I think the repair was more than they were willing to pay and they probably ended up replacing the unit lol!! Great video man, I like how you went ahead and unsweat some joints further down the circuit to keep the repairs easy and clean! Great job. How many years in refrigeration do you have?

    • @IceMachine411
      @IceMachine411  7 месяцев назад +2

      Oh ya I know what you’re talking about. I’ve had one of those myself. They’re a pain sometimes but actually pretty easy to work on. I’ve been in refrigeration for about 3 years. I use “refrigeration” light because I really only work ice machines. “Work smarter, not harder”

  • @mikestevenson1819
    @mikestevenson1819 6 месяцев назад

    Nice

  • @gedyx
    @gedyx 5 месяцев назад

    good job

    • @IceMachine411
      @IceMachine411  5 месяцев назад

      Are you Ice Man Mike from the Sacramento area?

    • @gedyx
      @gedyx 5 месяцев назад

      @IceMachine411 yes what can I do for you?

    • @IceMachine411
      @IceMachine411  5 месяцев назад

      You’re a legend! I’ve heard good things! I’ve been asked a few times if I know Ice Man Mike. Nice to finally meet you!

  • @life2breaksinc
    @life2breaksinc 7 месяцев назад

    Great content with explaining the process. Question... how long would that normally take you to complete? I'm just curious. Thanks

    • @IceMachine411
      @IceMachine411  7 месяцев назад +1

      Oh that’s a good question. Im trying to think back. Im going to guess 4 hours. Pulling Vacuum is the longest part of the job. Four hours is enough if everything goes smoothly.

  • @manhpham8052
    @manhpham8052 8 месяцев назад +2

    Super when u avoid to do brazing that hot gas valve in the tight space

  • @s.k6130
    @s.k6130 8 месяцев назад

    Thanks for your knowledge. Its OK to put fan cycle switch on manitowoc remote condenser fan motor if HEAD MASTER is not bypassing in cold?

    • @IceMachine411
      @IceMachine411  8 месяцев назад +1

      If your head master isn’t working properly the right thing to do is to replace it.

  • @juancarlosguillen593
    @juancarlosguillen593 2 месяца назад +1

    Quick question brother, what if no ice is producing I'm new to this field. I've been told headmaster, thermostatic bin control switch, compressor, txv, & board..
    I had power, it was not low on pressures had my solenoid magnet & hot gas valves were working fine. Any chance i can get some feedback?

    • @IceMachine411
      @IceMachine411  2 месяца назад

      Of course brother. I will admit that it’s extremely difficult to diagnose a machine through the comment section. Most manufacturers have a tech support team that will be able to walk you through the process step by step. What is the make and model of your machine?

  • @johnrotramel5204
    @johnrotramel5204 7 месяцев назад +1

    What rod are you using on that stainless valve to copper connection?

    • @IceMachine411
      @IceMachine411  7 месяцев назад +1

      Harris stay-silv 15 silver brazing alloy.

    • @johnrotramel5204
      @johnrotramel5204 7 месяцев назад

      @@IceMachine411 I see, I thought a higher silver rod might be required since it’s stainless but when I got the valves I realized they were copper coated on the inside. They were sticking open sometimes. Swapped them out and everything worked great.
      Thanks for the advice!

  • @frankduarte7109
    @frankduarte7109 6 месяцев назад

    What do you use for welding copper to stainless?

  • @marcoferreira226
    @marcoferreira226 7 месяцев назад

    what tip are you using in the torch

  • @kimranharris
    @kimranharris 5 месяцев назад

    Can the damage hot gas solenoid be the cause of my machine going in thaw continuously

    • @IceMachine411
      @IceMachine411  5 месяцев назад

      It could be. There are other things that could cause thaw mode. Bin switch is one of them. Dirty evaporator, control board relay and refrigeration system are possible causes.

  • @2969566
    @2969566 7 месяцев назад

    Hey, what alloy you are using for refrigeration brazing?

    • @IceMachine411
      @IceMachine411  7 месяцев назад +1

      15% silver solder.

    • @2969566
      @2969566 7 месяцев назад

      @@IceMachine411 same as resi

  • @calvinthompson5398
    @calvinthompson5398 8 месяцев назад +1

    Was that the second replacement of that valve? Looks familiar

    • @IceMachine411
      @IceMachine411  8 месяцев назад

      First time for me…on this machine.

  • @christopheralvarado351
    @christopheralvarado351 7 месяцев назад

    Off topic I bypassed the timer relay on the indigo next model on the condenser but it was already replaced and same thing happen again what else could be going on. It’s also under Warrenty?? After by pass it made 3 good batches of ice

    • @IceMachine411
      @IceMachine411  7 месяцев назад

      I think Manitowoc has a service bulletin out about this. Here’s the technical support phone number. 800-247-4520

    • @IceMachine411
      @IceMachine411  7 месяцев назад +1

      I’ve replaced one myself. Haven’t had two in a row though. At least it’s under warranty. Hope that helps.

    • @christopheralvarado351
      @christopheralvarado351 7 месяцев назад

      Will see what happens when we put it back in

  • @zokari407
    @zokari407 7 месяцев назад

    Where are you located
    I have issues with my ice machine it harvest but doesn't drop ice and starts to make new cycle and just builds up more ice slab

  • @charlesrios8542
    @charlesrios8542 8 месяцев назад +1

    Do you do jobs out of state? I have problems with my AC in New Jersey. Do you travel? I will pay travel costs

    • @IceMachine411
      @IceMachine411  8 месяцев назад +1

      I’ll do anything for the right price.

  • @whitebear1903
    @whitebear1903 Месяц назад +1

    In my machine Manitowoc QM45A after harvest it stuck at 60psi, I suppose it's the same issue with the gas valve.

    • @IceMachine411
      @IceMachine411  Месяц назад

      Maybe. Call Manitowoc tech support to verify. Would hate for you to change parts before knowing 100% what the issue is.

    • @whitebear1903
      @whitebear1903 Месяц назад +1

      @@IceMachine411 I had disconnected the wire of that gas valve and started ice machine in the ice making mode the pressure was 35 psi on the low side then I manually energized that gas valve for a few seconds by 120V will the cord (simulating the harvest mode) the pressure rised up to 60 psi but after removing the 120v it didn't drop back to 35 psi, so I suppose it's gas valve, the txv seems to be good.

    • @IceMachine411
      @IceMachine411  Месяц назад

      Smart!