@@Engr.Aminul I have reviewed it, thanks for the information ... my problem is that my elevator opens and circles the doors correctly. but I have a door that opens on a single floor and when the elevator is on that floor and I pulse the hall call of the same floor the door does not reopen .. this happens only on this floor .. since the other door does work properly in the other floors ... I have configured according to the information provided FB-00 = 2, FB-02 = 65534, FB-04 = 00001
Simple matter. Fb-02 for front door fb-04 for rear door. Both door built-in value 65535 Binary value of 16 floor 1111111111111111=65535 When you off any floor Deduct it's binary value. Example 2 nd floor off 1111111111111101=65533 1st and second floor off 1111111111111100=65532 Floor start from right side
@@Engr.Aminul I understand, the parameters are already configured correctly for the doors openings in selected floors, the problem is in the reopening of the 2nd door, in which it does not reopen with the hall call. Maybe you have information about the reopening of doors .. !!
Hello enyone help me. I have double side open G+2 lift. all the time lift reaches ground floor rear side door open close function not happen. but lift comes to top floor rear Side door open close function happen but there is no need for rear side open at top floor. In my site ground floor only double side other floor single side only. So now what can I do. Which parameter I have to adjust
Good afternoon friend! I have a problem with such equipment. when I make the high adjustment it when it finishes the Cirilo of fire appears and goes to the ground floor I already checked the keys in the buttonhole and the button inside the cabin. can you help me?
That installation is nice, The motor is normally meant to be used as a MRL but it's good in a motor room too infact, it's more solid in a motor room and the logic works good too. P.s nice English
53 fault 1. door inverter switch off 2. door limit not ok 3. door open close not ok 4. door contact short Error 51 can communication fault serial card / ctb board not connect with motherboard
Hi everybody. Please where I can enter the fire signal from a Fire Detection Panel (dry contact) to make the lift goes to base floor, open the doors to evacuate the people and then disable the lift until the fire alarm is over. I hope someone can help me
Error 41 1. power supply three phase, 24v 2. Safety problem 3. safety program for new lift when use x25, As safety x26, x27 door contact then program f5-36-4 f5-37-5 f5-38-5
Error 65, in nice 3000 controller, this lift 2 to 4 day good running again get problem like lift hang that is big problem it happens regulary please give me a solution, many engineer seen that they work but 2 day after same problem come, please help me, give a permanent solution idea
run contactor feed back problem. check point 1. 24v power supply 2. x6 led on or not 3.run contactor coil ok or not? 4. run contactor mechanically jam or not? etc....
Please help me,why is it that brake contactor won't energized during automatic operation
please explain how to adjust the lift cabin leveling by key pad NICE 3000 module thank you.
During automatic operation ws and fx contactor will pick up except the BY contactor won't energized,pls tell what is locking of what I'm doing,tnx
hi sir can you helf me nice 3000 controller shaft tune OK after car call not received . pls helf me.
how is this motor brand name
Good morning,
automatic reset for error 20-009, is there this function?
Hello
Do they have information about the reopening of double entry cabins ..?
I would thank you a lot
Sure. I will give a video. Thanks for comments.
I uploaded a video you can check it.
@@Engr.Aminul
I have reviewed it, thanks for the information ... my problem is that my elevator opens and circles the doors correctly. but I have a door that opens on a single floor and when the elevator is on that floor and I pulse the hall call of the same floor the door does not reopen .. this happens only on this floor .. since the other door does work properly in the other floors ... I have configured according to the information provided
FB-00 = 2,
FB-02 = 65534,
FB-04 = 00001
Simple matter. Fb-02 for front door fb-04 for rear door.
Both door built-in value 65535
Binary value of 16 floor
1111111111111111=65535
When you off any floor
Deduct it's binary value.
Example
2 nd floor off
1111111111111101=65533
1st and second floor off
1111111111111100=65532
Floor start from right side
@@Engr.Aminul I understand, the parameters are already configured correctly for the doors openings in selected floors, the problem is in the reopening of the 2nd door, in which it does not reopen with the hall call.
Maybe you have information about the reopening of doors .. !!
i am getting Error 36 time and again, when checked the contact feedback is fine and no issue , but the error is displayed
Ckeck :
1. Power supply 24 v
2. Break power
3. Break feedback
Check run contactor coil is normal.Safety line voltage is too low.
Hi sir can you helf me motor tuning time F3 brecker tripping pls give me a solution.
Nice 3000 controller
স্যার আপনি নাইচ কন্ট্রোল নিয়ে যাবতীয় সব কিছু তুলে ধরেন অনেক জানার আছে।
Hi sir bro how are you can you send to me your WhatsApps number please
+8801518328474
Hello enyone help me. I have double side open G+2 lift. all the time lift reaches ground floor rear side door open close function not happen. but lift comes to top floor rear Side door open close function happen but there is no need for rear side open at top floor. In my site ground floor only double side other floor single side only. So now what can I do. Which parameter I have to adjust
Check parameters group Fb.
Hi sir, how we know used watts
Good afternoon friend! I have a problem with such equipment. when I make the high adjustment it when it finishes the Cirilo of fire appears and goes to the ground floor I already checked the keys in the buttonhole and the button inside the cabin. can you help me?
edson silva check the fire programming. F5 menu
It's may be f5-08 value
11
Make it 0 and checking.
If done then confirm wireing and re programming.
Check group F5 parameters.if any 11 r 43 then set to 0.
R 23/55 then also set to 0.
Thanks ☺️
what is protocol?
Good evening sir .I how to solve monarch error 84 please can explain
Apply e65 fault solution
can you help me to get the electrical diagram of it?
send your mail address
Sharpliftsbd@gmail.com
That installation is nice, The motor is normally meant to be used as a MRL but it's good in a motor room too infact, it's more solid in a motor room and the logic works good too.
P.s nice English
how to solve E20-009 ????
All part parts changed makings auto tune error code 20 coming
Encoder fault
Reset on default parameters.
And Autotune with respect to nameplate of motor.
hello dears we need complete all error list and trouble shooting details vedio.
Ok
how to fix the error 35 on a monarch drive?
hey man. you can check circuit shorcut. board communication. ss1 ss2 sl or ss3.
Need shaft learn to remove it.
Automatically remove when shaft learning is complete.
How to fix error E.34 on a monarch drive?
Motherboard fault
Thank's, About the solution..?
Replace motherboard.
Error 36 is coming how to set this one.
Check the run contactor feedback
Check run contactor feedback and safety line voltage.
Please tell me how to solve error 20&33
e-20-
break
encoder
power
fault
কেমন আছেন sir, আমি ডোবাই থেকে দেখছি sir, আমার জন্য একটা গ্ৰোপ কন্ট্রোলের ভিডিও বানান দয়াকরে NIC3000new
I am from Algeria. i need PCB monarch nice 3000 but I don't know where.also I need tool test.?? can you help me??
Welcome. You send me inverter model.
How to solve err 53 and 51 ?
Pls advise ..thanks
53 fault
1. door inverter switch off
2. door limit not ok
3. door open close not ok
4. door contact short
Error 51
can communication fault
serial card / ctb board not connect with motherboard
@@Engr.Aminul thanks brother..can i have yr watsapp num brother ?? Please 😊
@@jgdev2966 +8801821831888
@@Engr.Aminul thanks brother..p👍👌
@@Engr.Aminul is that your name..?
Boa noite, como mudar a linguagem do voicer para Porturgues Brasil
Pls comments in English language
Hi everybody. Please where I can enter the fire signal from a Fire Detection Panel (dry contact) to make the lift goes to base floor, open the doors to evacuate the people and then disable the lift until the fire alarm is over. I hope someone can help me
Good day all
Is the monarch ME320LNNew integrated?
Good day All
Is the monarch ME320LNNew integrated drive.
F5 group you can choose a free port and set 11/43 with respect to no/nc.
Can you help for the control nice 3000 error 16?
phase miss of motor to inverter
@@Engr.Aminul How to handle it how?
@@dselevator2349 check the connection between motor and controller u v w
Error 28 somossa ta ki vai
plz need full programing video
its only basic information. If need any special document pls mention. mail me aminul963@gmail.com
bojlam naa vaiya
116 error problem
How to solve Error Code 41 ? Please give me some help brother 🙏
Error 41
1. power supply three phase, 24v
2. Safety problem
3. safety program for new lift
when use x25, As safety
x26, x27 door contact then program
f5-36-4
f5-37-5
f5-38-5
@@Engr.Aminul thank you brother. Youre the best👍
How to solve landing call not register
I have error49 and error66 how its is solve please tell me
mon ascenseur SIGLEN ne bouge pas avec la programmation MONARCH NICE 3000 AIDE MOIS EN LANGUE FRANCAISE
Check Fb-09 parameter set to 0.
CTB output and door lock and limit signals.
How to solve error 34, nice 3000 drive
Logic fault. need to replace board
how to solve error 28 on a monarch drive?
Check parameters group F5.if any 68/100
Then check no r nc.
R set to 0 for disconnect.
How to solve problem error 41?
power /
safety fault
Power/safety fault r safety circuit feedback.
Error 65, in nice 3000 controller, this lift 2 to 4 day good running again get problem like lift hang that is big problem it happens regulary please give me a solution, many engineer seen that they work but 2 day after same problem come, please help me, give a permanent solution idea
send your mobile no ?
I Know you very well.
01673992184 this is my number , first of all send me an sms
A.M Zubair Hi
Give your number
Can u help me to unblock password in monarch 3000 controller???
its not possible.
hello Imran please check me here vmushi88@gmail.com
Sharp Lifts & Engineering hello sir please I need your email or any contact kindly send me through this email vmushi88@gmail.com
Error 40 how can I solve sir ?
How to solve Err66 &65
Error 38?
encoder fault
@@Engr.Aminul спасибо
স্যার আপনার সাথে জোগজোগ করতে চাই।।নাম্বার টা দেন।।
01821831888
how to restart nice 3000+ motherboard
plz help
+8801710625170
@@Engr.Aminul I need to call you.. I have a monarch n300+ system. The control board is missing
@@Engr.Aminul the number is not correct
@@atikalove9 check again
+8801710625170
+8801711428593
Sir How to Solve Nice Three Thousand Erro 03/04
Overcurrent fault
check below
1. Encoder
2. Motor check
3. Inverter output short circuit
4. Autotune fault.
etc
Autotune fault ,encoder r weight balancing
Error Code E36?
Check run contactor feedback and safety line voltage.
How to solve E63?
63, 65, 68 same
Change the eight and ninth to "1" in F8-19.
Clases online para programar?
run contactor feed back problem.
check point
1. 24v power supply
2. x6 led on or not
3.run contactor coil ok or not?
4. run contactor mechanically jam or not?
etc....
How to fix error 34
Replace motherboard
Error e53?
Nice3000
door limit fault
good
Can you help eror 69
Sir your video is so good but your voice is low sir pls raise your voice volume
Its the first video. next will be implement...
290 volt gearless motor
E30-103
Error 72
hi
nice 3000 fault E 37
1. Check break it's open/not
2. Check break voltage
3. Check break magnetic contact feedback
4. Check power supply 24v
5. Check transformer
@@Engr.Aminul tuiii
Sar Hindi mein batao
erroe 20
ERROR 20
Fix e34
Replace MCB.
Error 88?