The Twin & Earth Cable You've Always Dreamed Of is Here!

Поделиться
HTML-код
  • Опубликовано: 14 янв 2025

Комментарии • 559

  • @AdrianBawn
    @AdrianBawn 11 месяцев назад +81

    I'm just a DIYer, but i think I speak for most people who ever need to touch electrics, Thank you so much for this. Its about damn time. I've never understood why the CPC didn't have a sheath if you always have to apply one when you strip the cable back.

    • @Danish1der
      @Danish1der 11 месяцев назад +12

      I always assumed the cpc didn’t have a sheath so that it was not insulated from potential damage to the cable?

    • @x1BULLETfromABOVE1x
      @x1BULLETfromABOVE1x 11 месяцев назад +7

      It's cost related and also if you were to drill through the cable with a screw, when say putting up brackets for a shelf,you would have a higher chance of hitting the earth and one of the line conductors to cause a safe path for the electricity instead of making the screw live

    • @deang5622
      @deang5622 11 месяцев назад +10

      The CPC doesn't have insulation because it doesn't need it. It is surrounded by the cable sheath and the two adjacent conductors are insulated so there is nothing for the earth conductor to come electrically into contact with anything else.
      Therefore the cable can be made more cheaply.
      When analysing problems in electricity, you have to ask yourself: what's the electric shock risk posed by what we're doing, and what is the fire risk posed by doing something?
      And the answer here to both questions is: nothing.

    • @deang5622
      @deang5622 11 месяцев назад +7

      You don't always apply a sheath when you strip it back. That is not correct.
      There are two different things going on. Insulation and marking.
      The line and neutral are covered and that is insulation. The purpose of insulation is to ensure that no electrical contact can be made from the inner copper conductor and anything else.
      Marking is where we apply a piece of coloured sleeve over the conductor and the colour of the sleeve indicates the purpose of that conductor. This is NOT insulation. The sleeve might have some electrically insulative property but it is much thinner than the insulation that is used for the line and neutral. It does not offer the same level of insulative protection.
      You are assuming that the sleeve (which is typically yellow) that is put on the earth conductor is being done to provide insulation. That is not the case.
      When you have a bare conductor wired in, someone else coming along later after it was installed, doesn't know what that conductor is carrying or what its purpose is, so you mark it.

    • @JasperJanssen
      @JasperJanssen 11 месяцев назад +12

      @@deang5622the whole condescending explanation of the difference between insulation and marking is completely irrelevant to your first sentence. You do, in fact, always apply a sheath when you strip it back. Not insulation, but you do apply a marking sheath.

  • @GSHElectrical
    @GSHElectrical 11 месяцев назад +21

    Very exciting for our industry 👏🏼

    • @efixx
      @efixx  11 месяцев назад +2

      Sure is

    • @12000gp
      @12000gp 11 месяцев назад +4

      Is it that exciting? How many seconds will it save?

    • @Gaunty213
      @Gaunty213 11 месяцев назад

      Continue using the none sleeved version. Thats that sorted

    • @professionalineverything
      @professionalineverything 11 месяцев назад +1

      Hi Efixx in disguise.

    • @Ben-gm9lo
      @Ben-gm9lo 11 месяцев назад

      What about the poor sleeving production companies. Think of the millions of unemployed this will create (just a joke, in case that slipped you by).

  • @barryjdwyer
    @barryjdwyer 11 месяцев назад +39

    Finally the UK has caught up with Republic of Ireland! The hours of sleeving you're going to save!

    • @benjurqunov
      @benjurqunov 11 месяцев назад +2

      Meanwhile in USA...
      Earth ground is bare and they let it touch anywhere it happens to get pressed against.
      It's been that way 80-ish years when they started putting earth ground conductor within a jacketed cable.

    • @dmitripogosian5084
      @dmitripogosian5084 10 месяцев назад +3

      @@benjurqunov And why shouldn't it be ....

    • @dejanbrice8774
      @dejanbrice8774 10 месяцев назад

      Ground loops, control over potential@@dmitripogosian5084

    • @MostlyPennyCat
      @MostlyPennyCat 10 месяцев назад +1

      ​@@benjurqunov
      When there even _is_ an earth.

    • @anticat867
      @anticat867 10 месяцев назад +1

      @@benjurqunov Meanwhile in Central Europe, we always use 3 identical conductors for L, N and PE.

  • @Thermoelectric7
    @Thermoelectric7 11 месяцев назад +80

    It's a bit bizzare watching this from Australia. Our twin and earth started coming with sleeved earth probably 20-30 years ago. Only find the bare earth in pretty old homes now. Surprised it's taken this long for you lot to take it up!
    We also moved away from solid conductors in everything apart from 1mm. Stranded is a lot nicer to work with.

    • @efixx
      @efixx  11 месяцев назад +4

      Thanks for your insight from Australia and watching 👍🏻

    • @retrozmachine1189
      @retrozmachine1189 11 месяцев назад +5

      Yes, while we do have the option of using solid if we like, stranded is just so much easier to handle and pull than solid that no one in their right mind does.

    • @12000gp
      @12000gp 11 месяцев назад +1

      I’ll agree completely on the stranded vs solid but is it much of a difference having a sleeved CPC?

    • @Thermoelectric7
      @Thermoelectric7 11 месяцев назад +6

      @12000gp Easier to work with, don't have to carry sleeving with you or have it fall off and all that jazz.
      If you're going to sleeve it when you terminate the cable, why not just sleeve it at the factory? That and all our earths are required to be stranded, and sleeving that is more annoying.
      To me, the only situation where leaving it bare would make sense is where you don't need to sleeve it. However, as that's mandatory, what advantages does a bare CPC have?

    • @retrozmachine1189
      @retrozmachine1189 11 месяцев назад +11

      @@Thermoelectric7 The usual explanation is that it gives better protection should someone drive a nail through the cable, ie higher probability of contacting the earth wire should active/neutral be nicked. It's a stretch at best.

  • @martinsweltdertechnik1868
    @martinsweltdertechnik1868 10 месяцев назад +41

    New in UK. In Germany since 50 Years.

    • @raxorlp9932
      @raxorlp9932 10 месяцев назад +3

      i thought the same

    • @jonasduell9953
      @jonasduell9953 10 месяцев назад

      Hey don't be mean! I mean I saw a lot of those old 180° spring loaded turning switches in the UK too, almost felt like a Victorian rich person adjusting the gas flow in my modern gas supplied London Estate lighting.

    • @raxorlp9932
      @raxorlp9932 10 месяцев назад

      @@jonasduell9953 :D

    • @louisvl10
      @louisvl10 10 месяцев назад +1

      also the uk has smaller thickness wire for earth. that's forbidden in belgium

    • @paradieshenne
      @paradieshenne 10 месяцев назад +1

      @@louisvl10 I would think it depends. Here in Germany, it can be smaller for conductors >16mm²

  • @daved4547
    @daved4547 11 месяцев назад +39

    You had me laughing as I watched the earth sleeve drop and thought, 'Yep, been there, just a few times' 😏😎🖖

    • @John-ou4rm
      @John-ou4rm 10 месяцев назад

      Especially when it's dark because the electrics are off!

  • @thanhhuynh272
    @thanhhuynh272 11 месяцев назад +12

    Australian here: We have had a dedicated Earth sheath in green-yellow in our 2.5 amd 1.5mm squared T.P.S., (Tough PVC Sheath) cables for about 30 years now, prior to that, the Earth was bare as in your cable.
    Some differences/developments in our cables.
    1920s Vulcanized India Rubber and cotton sheathed single solid core wire in imperial…about 2mm squared, lain in pine trunking. Imported from England, so identical to yours. Earth run seperately, if st all.
    1930s. Same VIR in black painted, rolled steel conduit. Earth still run seprately.
    Also, in a similar form to modern, Lead, yes, lead, the 84th element on the perioic table…shearhed cable, with the same VIR inside in red and black. Red colour was rather dull compared to modern polymers.
    1940s. War surplous black rubber. Same flat format as modern, no Earth, (Run separately alongside, if at all). Inner cores, soft rubber that tended to bobd to the outer black sheath. No cotton weave over the rubber inners.
    All these older cables had single solid cores that were tin plated copper. I think the tin was put there because the bare copper would react with the sulphur in the rubber.
    1950s. First PVC insulated cables. Two cores in vivid red and black in a black sheath with a “score” on the wide side making it look like thick “figure-8”. Conductors: Still single solid, but now without the tin plating.
    1960’s. First like the black ‘50’s stuff, but now in white. Somewhat later the bare Earth was added between the red active and blue neutral….so really similar to the stuff you use there now!
    1970’s. Earth was made stranded, first three strands, later increased to seven strands. ALL AUSTRALIAN CABLES for donestic wiring have an Earth conductor with the same cross-sectional-area as the main active and neutral!
    Much of the remainder of the 20th century: Things stayed much the same, however the Government made a decree thst all public buildings be wired with cable that had all three conductors seven stranded, do cable with this stipulation was manufactired and it could be used for domestic rewires too if desired, but it was more expensive.
    Turn of the Millenium: Sometime sround the turn of the Millenium the gree-yellow sheath was added to the centre Earth core and the use of single-solid cores was banned and ALL cables had to be seven stranded. It has been much like thst ever since.
    So far, that European “madness” of brown acrive and blue neutral….which gets confused with blue phase in three phase stuff…has not infected us….yet…and hopefully NEVER! Our single phase active/phase colour is still RED = DANGER and Black = absence of all colour = absense of voltage (under normsl conditions). And don’t even mention that American craziness, BLACK = acrive and WHITE = neutral…what sort of madness is that. Theor heads must have been put on backwards!
    Here, white is a switched active in a lighting circuit between a switch and a light or sometimes some other load.
    Our modern TPS has two paralell scores down each side to facilitate tearing it back to reveal the inners, the older stuff without the seperately dheathed Earth had just ine score on each side.
    New Zealand cable is identical…but with one difference…the active is in the middle and shielded by the neutral on one dide and the Earth on the other (both connected by the M.E.N. Link in the switchboard. (Kiwis were and still are just one step ahaid of us Aussies!)
    Our cable brands are Pirelli, Olex and Advance Cables.
    The newest cables have layered insulation on the active and neutral inners that is white closest to the copper strands and has a layer of red or black over the white. The Earth is green with s two thinner yellow traces, these colours extend right through to the copper cores.
    Cheers to those st Doncaster Cables, hope it gives you some ideas for further improvment.
    P.S. All our goodbrands have chalk dust between the inner and outer. We are dtrating to see fake Chinese clones invade our market with dire consiquences.
    The Globe Collector, Tasmania.

    • @BigHenFor
      @BigHenFor 10 месяцев назад +1

      No-one is immune from criticism, but criticism should be deserved and constructive. I don't think your comment fits those criteria. Moreover, the motivation of electricians everywhere is safety to them and the consumer. Blue and brown causes no problems for the decades they've been the standard in the UK. Either you know what you're doing, or you should leave electrics alone.

    • @superslash7254
      @superslash7254 10 месяцев назад +1

      Spellcheck my dude. Or stop youtubing while drunk.

    • @TerrisLeonis
      @TerrisLeonis 9 месяцев назад +1

      That "European madness" as you call it was introduced to Aus/NZ Standard 3000 in 2018. The old colours are still permitted (AS/NZS 3000:2018 permits active to be any colour except green, yellow, green+yellow, black or light blue, permits black OR light blue as neutral, and mandates earth must be green+yellow). But the recommended colours are brown for live and light blue for neutral. Three-phase colours are brown for P1, black for P2, and white or grey for P3. Yes, we have black for a live in three phase now.

    • @TerrisLeonis
      @TerrisLeonis 9 месяцев назад

      I like to think of it like this: the brown wire is the same colour your pants will become if you touch it.

    • @whizzo94
      @whizzo94 9 месяцев назад

      Got to agree with you about the insulation colours. I believe there have been some accidents in the UK where a phase and neutral have been mixed up because of the stupid European colour coding. And the mistakes have not been made by amateurs.

  • @mistymick4905
    @mistymick4905 11 месяцев назад +27

    Hallelujah, About bloomin’ time. We’ve had this type of cable for years in Australia and New Zealand. How many times have you sparky’s put oversized sleeving on the earth core,I wonder!

    • @jens-olefrimann6818
      @jens-olefrimann6818 10 месяцев назад

      Also in Denmark

    • @BurkenProductions
      @BurkenProductions 10 месяцев назад

      You're cabling are the worst dude

    • @chimpyd
      @chimpyd 10 месяцев назад +4

      @@BurkenProductions Your spelling is the worst

  • @sergiofernandez3725
    @sergiofernandez3725 11 месяцев назад +45

    This is groundbreaking stuff Doncaster cable for cable in England. Ireland had this years ago. This product will change the uk market. Well done team Doncaster cable

    • @Robert-cu9bm
      @Robert-cu9bm 11 месяцев назад +7

      Same in Oz

    • @mernokimuvek
      @mernokimuvek 11 месяцев назад

      Most of Europe never allowed this bullshit. Even early 1960s cables had full sized and insulated ground wire.

    • @michiellombaers3198
      @michiellombaers3198 11 месяцев назад +8

      Same in continental Europe ... 🤷‍♂

    • @mernokimuvek
      @mernokimuvek 11 месяцев назад

      The UK is a 3rd world country compared to continental Europe. They have ugly electrics and they use miles instead of kilometers. Far from modern civilization.

    • @rogerphelps9939
      @rogerphelps9939 11 месяцев назад +7

      This is a no brainer. The original spec should have mandated a sheathed earth conductor.

  • @heffo1992
    @heffo1992 11 месяцев назад +37

    We have had this in 🇮🇪 for years with the exception the CPC is the same size as the other conductors.

    • @efixx
      @efixx  11 месяцев назад

      👍🏻👍🏻👍🏻

    • @gabor.nadudvari
      @gabor.nadudvari 11 месяцев назад +3

      UK is one step closed to IEC standards, and less hamonisation will be required.

    • @steveosshenanigans
      @steveosshenanigans 11 месяцев назад

      Same in Australia…..we had this cable for years

    • @isaac827
      @isaac827 11 месяцев назад +2

      @@steveosshenanigans At least 30 years.... I was an apprentice almost that long ago, and the only time I have ever seen cables like this it is in old installations.

    • @CBE-d6j
      @CBE-d6j 6 месяцев назад

      @heffo1992 i wish the cpc was the same size, looks like this is still a 2.5mm and 1mm. 😭

  • @MervynPartin
    @MervynPartin 11 месяцев назад +11

    Brilliant idea. The comment about dropping the sleeving is so true- usually when I've been on a stepladder.

    • @Ben-gm9lo
      @Ben-gm9lo 11 месяцев назад +1

      So this idea has a safety benefit attached too!

  • @walterjwalnut9964
    @walterjwalnut9964 11 месяцев назад +9

    Australian PVC twin and earth has had the earth (CPC) fully insulated since before I became experienced with it in the mid 1970's, i.e. originally green but more recently yellow green insulation the same overall thickness as the active and neutral lines insulation. Also our earth cable itself is the same cross section and material as the active and neutral cables for cables up to 4mmsq, after that the earth cable can be reduced cross section. Personally can see the benefit, but can't understand the hoopla about a leap that brings the UK up to standards that have existed elsewhere for 50+ yeas.

  • @der.Schtefan
    @der.Schtefan 11 месяцев назад +8

    I am not a Brit, just a EU engineer. This video popped up on my YT feed. If I understand, British electricians need to strip the 3-wire cable, then artificially put a yellow/green sleeve on the earth conductor that runs otherwise bare? And this company has designed a cable that fits the existing standards, but runs the earth insulated with a "pale mauve" color? (not sure i can identify this correctly in english)

    • @dlevi67
      @dlevi67 11 месяцев назад +1

      Yes, other than the colour of the insulation, which is normal green-and-yellow striped.

    • @marcviej.5635
      @marcviej.5635 11 месяцев назад +5

      this is standard in the EU for like 50 years

  • @Smart-electrical
    @Smart-electrical 11 месяцев назад +10

    What a time to be alive.

    • @Doncaster_Cables
      @Doncaster_Cables 11 месяцев назад +2

      Nice to hear 🙏

    • @richnorman7325
      @richnorman7325 11 месяцев назад +2

      😂😂😂😂😂

    • @nickdobb2555
      @nickdobb2555 11 месяцев назад

      When you're alive is always the best time to be alive. Some might say the *only* time.

    • @nickdobb2555
      @nickdobb2555 11 месяцев назад

      Or for that matter, what a time to be a CPC. I'll get me coat.

  • @adrianupnorth
    @adrianupnorth 11 месяцев назад +13

    I just love Doncaster cable. I had to use some cheap Indian cable a few weeks ago - what a difference. Great news, not enough wholesalers sell DC

    • @efixx
      @efixx  11 месяцев назад

      👍🏻👍🏻

    • @Doncaster_Cables
      @Doncaster_Cables 11 месяцев назад +2

      We would agree... but maybe slightly bias! 😃Thank you for the nice comment and support.

    • @nickdobb2555
      @nickdobb2555 11 месяцев назад +1

      Toolstation sell DC

    • @nickdobb2555
      @nickdobb2555 11 месяцев назад

      ​@@Doncaster_Cablesdoes the Earthsure design reduce the likelihood of cable damage/penetration causing a current path to the CPC in order to cause tripping, or has it been designed so this remains the same? Presumably we don't want to reduce the likelihood of cable damage resulting in an ADS...

  • @holzwurm_hd7029
    @holzwurm_hd7029 11 месяцев назад +6

    Wait what? The UK finally has isolated ground wires?
    In germany you are not allowed to use anything besides double isolated wires in house wiring.

    • @joansparky4439
      @joansparky4439 10 месяцев назад +1

      The UK have had "some sort of" democracy for several centuries.. until they are ahead of the pack again it will be a while and needs to break. Only then will that society be able to keep up or even lead again.. this is (unfortunately) to be expected.

  • @acespark1
    @acespark1 11 месяцев назад +14

    Thanks Gary you have score us all a winner and Doncaster cables trying to take all the glory. 😁

    • @efixx
      @efixx  11 месяцев назад +6

      He is always trying to take the credit for other people’s ideas 🤣

    • @nickuk1978
      @nickuk1978 11 месяцев назад

      It's a lie, was my idea! #alternativetruths

    • @paulfox4348
      @paulfox4348 11 месяцев назад +1

      Same cable has been used in Ireland for a long time maybe 10 years, IS 6193B

  • @dsesuk
    @dsesuk 11 месяцев назад +2

    About time too. I'll be buying this.

  • @salmattrulz
    @salmattrulz 11 месяцев назад +3

    As an Apprentice Electrician working at a cable manaufacturing plant (not doncaster) love seeing these videos.

  • @shaggygoat
    @shaggygoat 11 месяцев назад +3

    Here in NZ, we have been using green-yellow sleeved Earth wires in our TPS (Tough Plastic Sheath) cables for many decades, originally in Live, Earth, Neutral order but now in Neutral, Live and Earth order (which I guess is probably safer given that Live is in the middle and RCDs/GFCIs are ubiquitous and would quickly detect a Neutral-Earth swap).

    • @jackfromthe60s
      @jackfromthe60s 11 месяцев назад

      TPS= Thermoplastic Sheathed

    • @shaggygoat
      @shaggygoat 11 месяцев назад +1

      @@jackfromthe60s: TPS as “Tough Plastic Sheath” is common in New Zealand written material (for example, that put out by WorkSafe, a government agency). I gather it’s because we used to have TRS = Tough Rubber Sheath, in contrast to the VIR (Vucanised Indian Rubber), which still exists in the death trap houses owned by slumlords.

  • @ooltimu
    @ooltimu 10 месяцев назад +1

    Why is the ground conductor thinner in UK? It should be at least the size of the phase/neutral

  • @terrykillip8504
    @terrykillip8504 11 месяцев назад +2

    Are you going to do a low smoke version?

  • @euanhaig4422
    @euanhaig4422 11 месяцев назад +2

    Glad to see it made in Britain!

  • @The1nsane1
    @The1nsane1 11 месяцев назад +6

    What a revolution. Good to see you pommies are finally catching up. Australia introduced this back in the late 70's.😂😂

    • @chairmakerPete
      @chairmakerPete 11 месяцев назад

      pointless - solving a problem that doesn't exist. Zero people have ever been killed by an uninsulated earth - which by definition, shouldn't be insulated.
      Next, notices warning that water is wet and ice is slippery...

  • @MorzakEV
    @MorzakEV 11 месяцев назад +7

    When I saw this in my feed, I thought it was dejavu!!! I was trying to work out if Valetines day was also April fools!

    • @efixx
      @efixx  11 месяцев назад +1

      Sorry 🤦🏻‍♂️

    • @cglees
      @cglees 11 месяцев назад +1

      It was originally an April Fools gag…

    • @MorzakEV
      @MorzakEV 11 месяцев назад +1

      Lol, yeah, I know @@cglees

  • @BillsCountrysideAdventures
    @BillsCountrysideAdventures 11 месяцев назад +3

    Well done guys again, masters at work. Well done on keeping same price, that is amazing.

    • @efixx
      @efixx  11 месяцев назад +1

      Thanks for the wonderful comment 👍🏻

  • @richardlegg190
    @richardlegg190 11 месяцев назад +1

    Will they be doing it in LSF?

  • @richardlewis5316
    @richardlewis5316 11 месяцев назад +3

    Hooray. I thought the exposed copper E was to ensure that if the cable fractured and the L & N were exposed they would touch the E first. But to have the E not needing the sleeve is so good. Many times I go to my box and cannot find the sleeving! Hopefully it will be stocked by B&Q and Screwfix soon.

    • @streaky81
      @streaky81 11 месяцев назад +1

      It doesn't ensure it, it might raise the odds - but I suspect it almost never happens in the real world. You're better of just having RCBOs/AFDDs and an occasional circuit test. If you think if you stretch the cable or bend the cable and it damages the conductor the insulation of the conductors will force them away from each other regardless, best you can hope for is the cable fails completely or an AFDD spots it.

  • @jimi272
    @jimi272 11 месяцев назад +20

    In Switzerland and the rest of Europe, we have „NYM“ cables for permanent installations. They all have 3 or 5 equally sized strains, of course with the right colors. Don’t understand how England is so behind in that regard😂

    • @GoonSmith007
      @GoonSmith007 11 месяцев назад

      Same I was confused by all the hype, this has existed in Australia for over a decade at least.

    • @lobbyhoe01
      @lobbyhoe01 11 месяцев назад +2

      And all that stupid color coding with heat shrink, here in germany you can get basically every combination of brown, black, gray, blue and green/yellow, or numbered black you’ll ever need, and usually up to 10 conductors, as NYM, NHXMH, NYY, N2YY or NYCWY, NA2YY and NAYY for >10mm2

    • @MrEdrftgyuji
      @MrEdrftgyuji 11 месяцев назад

      But you have the absolutely terrible colour choices that you forced on us.

    • @edc1569
      @edc1569 11 месяцев назад

      UK has always been an incredibly price sensitive market for domestic stuff, in commercial there’s not so much T&E and yeah we have all sorts of other cables too….

  • @b67fstb
    @b67fstb 11 месяцев назад +4

    I thought in Belgium things went slow . We have this for decades ! 😉

  • @andycrask3531
    @andycrask3531 11 месяцев назад +8

    That's brilliant

    • @efixx
      @efixx  11 месяцев назад

      Thanks for watching and commenting

  • @steve11211
    @steve11211 11 месяцев назад +3

    Wow well done truly innovative, my only slight concern is how it performs stripping the cable by pulling the CPC that so many of us are used to doing especially when the cable gets a bit old and the powder does not work as well.. Apart from that I would say if its the same price, just stop making the old T&E and have this as standard, it will be down to the wholesalers, not enough people will hear about this whereas if you just replace all your T&E with this when the sparky gets it and sees the surprise of cpc colour coded they will be like wow this is great cable ill make sure I get the doncaster cable again as thats great.. But most sparkies will just grab what the wholesaler has in stock..

  • @TheDarmach
    @TheDarmach 10 месяцев назад +1

    I didn't even know these cables aren't the standard in the EU, here they are used for most part of past 30 years

  • @Pepps_Electrical
    @Pepps_Electrical 11 месяцев назад +1

    A Notification come thou, said to myself I’ll watch it later when I get home like I always do but re read it when I get in the van and watched it straight away
    Nice game changer that for us 👌🏼👌🏼🙌🏼🙌🏼

  • @ThePlumbeus
    @ThePlumbeus 10 месяцев назад

    So I guess the big deal is that the cables share dimensions with the regular ones and of course the approval. We had cables with sleeved earth for longer than I live, but those are round with equal distribution, so they would not fit your standard components. Being able to use existing tools, switches and other components is quite important in the industry. Greetings from Germany.

  • @05009
    @05009 11 месяцев назад +2

    So is it now PVC PVC Twin and PVC CPC cable?

    • @Doncaster_Cables
      @Doncaster_Cables 11 месяцев назад +1

      You are correct, and this is exactly why we needed to come up with a name like Earthsure 😆

  • @TeamSimpsonRacing
    @TeamSimpsonRacing 11 месяцев назад +4

    Game changer 💪👍

    • @efixx
      @efixx  11 месяцев назад

      We thinks so 👍🏻

  • @rajnirvan3336
    @rajnirvan3336 11 месяцев назад

    Will there be a 3 core version of this too

  • @davidwilkins2368
    @davidwilkins2368 10 месяцев назад

    Everybody in the UK will be speccing this immediately :) What a great idea :)

  • @jayktee96
    @jayktee96 11 месяцев назад +4

    I've wished for this for 50 years (now retired) . I used to use 1mm t&e with 2 red cores for switch drops, but haven't seen it for a long time, maybe DC should bring it back with 2 brown cores. Taking it even further-how about 3c and e with 2 brown and 1 blue, for timer fans/PIR etc. I always hated silly bits of sleeving.

    • @Doncaster_Cables
      @Doncaster_Cables 11 месяцев назад +2

      Agreed on all points. We do still manufacture twin brown ordinary t&e. Nothing stopping us bringing a twin brown Earthsure to the market if it helps people 👌

    • @_eusty
      @_eusty 11 месяцев назад

      Bought some the other day with 2 brown cores by mistake... Prysmian though not Doncaster

    • @FirstDan2000
      @FirstDan2000 11 месяцев назад

      This is a great product, it will be welcomed by many
      I wonder if 4 core flex will ever be improved by having a blue core instead of a grey core - like we used to have before harmonisation? It's a pain sleeving or taping that grey in roses, plugs, and other lighting accessories.
      And we don't use 1mm 4 core in 3-phase no-neutral applications as suggested by the grey core.

    • @Ragnar8504
      @Ragnar8504 11 месяцев назад +1

      @@FirstDan2000 In Germany you can get four-core with a blue on special order I think. Not sure about flex but I've definitely seen building cable. It's not needed all that often though and due to low sales volume five-core can actually be cheaper than four-core.

    • @spankeyspangler
      @spankeyspangler 11 месяцев назад

      Most people might take the neutral to the switch Nowadays surely.
      I do and I only install radials.
      Crazy I know. 😊

  • @paulf2529
    @paulf2529 Месяц назад

    This is great news, Doncaster cable has always been a nice product to work with. A no brainer really to use this.

  • @stubsstubs
    @stubsstubs 11 месяцев назад +1

    Love this, but I’ve only recently discovered the Quickwire products (thanks to your videos) and love them! Will these still be compatible with this Earthsure cable?

  • @paulrennie3819
    @paulrennie3819 11 месяцев назад +4

    Great Stuff !!!

    • @efixx
      @efixx  11 месяцев назад

      👍🏻

  • @TehJumpingJawa
    @TehJumpingJawa 11 месяцев назад +1

    Even as a DIYer this is exciting! 😍

  • @vandergulden
    @vandergulden 11 месяцев назад +1

    Is this new new? Not a retouched old vid or so.
    Last year I was super exited that I found a house with wire nuts and old coloured cables with gray earth wire instead of the green yellow thing. (all the same size though) I think that changed in 1970 in the Netherlands. But never such a flimsy bare earth wire. (I honestly have no clue if it is called earth though). So I thought that should be from even before the colours changed in 1970.

    • @joansparky4439
      @joansparky4439 10 месяцев назад

      Earth is only needed for a couple milliseconds until the MCB / RCD / AFD cuts off that faulty circuit - it's not there to keep the circuit running, which is why it can be thinner.

  • @josephkaz9093
    @josephkaz9093 11 месяцев назад +1

    Would these still work with Quickwire?

    • @efixx
      @efixx  11 месяцев назад

      How to Strip EarthSure Cable
      ruclips.net/video/8D0iKhlqOsY/видео.html

    • @yngndrw.
      @yngndrw. 11 месяцев назад +1

      @@efixx I think he means the accessories, not the stripper.

  • @Chris-rs6nq
    @Chris-rs6nq 10 месяцев назад

    is this going to come out in LSF

  • @russellslater4037
    @russellslater4037 11 месяцев назад +1

    Will it work with Quickwire?

    • @efixx
      @efixx  11 месяцев назад +1

      How to Strip EarthSure Cable
      ruclips.net/video/8D0iKhlqOsY/видео.html

  • @DilipDas
    @DilipDas 11 месяцев назад

    I think I speak for everyone when I say, IT'S ABOUT BLOODY TIME!!
    I'm just a DIYer and son of an electrian and whenever we strip the cable back we have to apply earth sleeving on anyway so why not have the earth identified anyway??
    The amount of faff and hassle saved from dropping earth sleving will be emmense!
    And having it at the same price as T+E means just buy earth sure!
    Absolute game changer!! ❤

  • @jamesreilly8455
    @jamesreilly8455 11 месяцев назад

    Can this cable be used alongside the Quickwire T connectors?

  • @0dWHOHWb0
    @0dWHOHWb0 10 месяцев назад

    Wait is the news that you have all three in a cable now? Was that not a thing over there in England already?

  • @chrisyeates2289
    @chrisyeates2289 11 месяцев назад +2

    wow tbh a small but quite pleasant change to ffs I've drop the sleeve. again !!

  • @thermionicdude2044
    @thermionicdude2044 11 месяцев назад +7

    How ground breaking 😂 New Zealand and Australia have had this for years. Years ago when I did my part P in the UK even the instructor had no clue as to why the UK was so far behind on this. Glad your now catching up 👍

  • @tomhoward5484
    @tomhoward5484 11 месяцев назад +8

    I was told at college, that the CPC was unsleeved to help with ADS if the cable is damaged, as it would be easier for it to come into contact with the line and neutral conductors and activate the protective device 🤔

    • @milosavitch1
      @milosavitch1 11 месяцев назад +1

      this is exactly what I was going to say, if you put a screw through T&E all it has to do is touch earth, but if the earths already sleeved it might gently push it put the way. Not sold on this for my house, I might put it in a commercial building

  • @pstanyer1
    @pstanyer1 11 месяцев назад

    Absolutely cracking

  • @BrianCairns
    @BrianCairns 11 месяцев назад +6

    The equivalent of T&E in the USA (Type NM-B, commonly called "Romex") is also bare copper for the CPC (Equipment Grounding Conductor, usually just called "Ground") is always bare copper in my experience. The difference is that there is no requirement to sleeve or label the EGC in the US National Electric Code. The EGC can be bare copper, solid green, or green with a yellow stripe.

    • @__Brandon__
      @__Brandon__ 11 месяцев назад

      Wouldn't you want it to always be bare in case someone drives a screw into it. You want the ground to sink the current immediately if a short is possible

    • @dmitripogosian5084
      @dmitripogosian5084 10 месяцев назад +2

      @@__Brandon__ Exactly, I do not understand the European desire to insulate ground. More over, since we are all still alive in North America, it looks like all this largely irrelevant, and just serves purpose to have extra regulation.

  • @kirkshielsthreesixtyuk8380
    @kirkshielsthreesixtyuk8380 11 месяцев назад

    Wonder if the new quickwire connectors are affected with this?

  • @raywelshman
    @raywelshman 11 месяцев назад +3

    I wondered how long it would take for the Uk to catch up with the Republic of Ireland who have Green/Yellow sleeved Earth in their T&E for some time now BTW they don't appear to have problems with cable clips etc. It has been a long time coming I'm 81 and a long time retired, we would have welcomed this in my day, in my time we called it Earth or Ground and not some silly acronym that has been used for a component supply company for many years & a lorry drivers exam, just Google CPC and see what you get..

    • @CBE-d6j
      @CBE-d6j 6 месяцев назад

      It was called cpc to avoid confusing the earth conductor from the circuit protective conductor.

  • @JBE
    @JBE 11 месяцев назад +4

    All this and we're still installing ring circuits.

    • @efixx
      @efixx  11 месяцев назад

      🤦🏻‍♂️👍🏻

  • @scotisland
    @scotisland 11 месяцев назад +2

    Very nice, must get some.

    • @efixx
      @efixx  11 месяцев назад

      Let’s us know how you get on 👍🏻

  • @Bigbluevwvan
    @Bigbluevwvan 10 месяцев назад +1

    Doncaster cable has alwayas been my first choice

  • @mfr58
    @mfr58 11 месяцев назад +3

    You won't be able to use the cpc to split back the insulation anymore......:)

  • @professionalineverything
    @professionalineverything 11 месяцев назад

    Thanks, now to extend the socket circuit with this cable. Which will confuse my dad who will disapprove the whole project on its own but its worth it as he will tell his friends about it.

  • @MrFameBright
    @MrFameBright 11 месяцев назад +2

    Great idea, if it's the same price and quality, this should be used as standard!

    • @keithterry2169
      @keithterry2169 10 месяцев назад

      Insulation doesn't come free, the price will have to rise.

  • @unrealillusion87
    @unrealillusion87 11 месяцев назад +1

    Im from Switzerland and cant seem to figure out why make things so complicated?
    Can anybode explain whats the deal with this? I would never want a smaller earth conductor..
    We have 3 conductors with 1.5mm2 crosssection. Earth must of course be the same crosssection as the live conductors.

    • @joansparky4439
      @joansparky4439 10 месяцев назад

      In ALL fault cases Earth only carries current for a couple milliseconds until the MCB / RCD / AFD cuts the circuit off. It doesn't need to be able to sustain that current. This is not it's job in modern installations. That's the hob of Neutral / Life.

  • @theondebray
    @theondebray 11 месяцев назад +1

    Nice idea, but one small disadvantage, if you pull the bare earth wire hard, it simply cuts thru the outer insulation, helping stripping time.

    • @paulf2529
      @paulf2529 Месяц назад +1

      I had an uncle who was what you might call a pro bodger/ handyman. He would advertise for small electrical work, extra sockets etc and used to call the earth wire the striping wire, he always cut his earth out on lighting and never bothered to sleave on sockets.
      I rekon when he finally retired all the local electricians would have rejoiced!

  • @parkeerwacht
    @parkeerwacht 11 месяцев назад +3

    so the UK is starting to do what we have over here for many years. however our cables are round (XMvK/YMvK which is most common) all conductors are the same size. never understood why it is blank over there, or smaller sized to the main conductors. Our regulations say that the Protective Earth must be the same conductor size as the main conductors up to 16mm2 above this it may be half of the main conductor size. we see this usually in steel armored (YMvK-AS) to be installed in the ground. Steel armored is only used in the ground to act as an extra mechanical protection, with the PE conductor consisting in bare copper strips (with additional steel strips as filler and reinforcement) or flexible tinned core with a braided steel mesh around it.

  • @adventuresofanathan
    @adventuresofanathan 11 месяцев назад

    My only question now is does it work with the quickwore junction boxes you feautred before? 🤔

  • @eddiereed5025
    @eddiereed5025 11 месяцев назад +4

    Great move from Doncaster matching te price for ordinary, who is going to buy old style now this is here other manufacturers got some catching up to do.

    • @efixx
      @efixx  11 месяцев назад

      Thanks for the positive comment 👍🏻

    • @jonathanbuzzard1376
      @jonathanbuzzard1376 11 месяцев назад +1

      That I would imagine is because Doncaster Cables are anticipating covering the development costs through increased sales. They may well have patents making it difficult for other manufacturers to follow.

  • @markpotter8280
    @markpotter8280 11 месяцев назад

    will be interesting to see a video on what this new cable is like to work with, i.e how well does it bend what is it like to strip. how easy is it to connect the fiddley earth into a pendant where most of us over sleeve all cpc's together. also now I can see the sales of wago's going up on light switches with cavity/fast fix boxes ( where you feed the switch obviously ). Also how many times have kitchen fitters drilled though a cable and nipped the live and cpc together now they may screw into the live but not break the insulation on the cpc which would leave a nice live screw in Mrs Smiths wall unit. Not sure if I like this cable yet only time will tell I suppose

  • @illusivec
    @illusivec 10 месяцев назад

    Not an electrician but I always wondered why the earth cables in the UK didn't come with the insulation already applied. My hypothesis was that it was a safety feature that'd make sure if the insulation on the live or neutral would ever get damaged, it'd short to earth and trip the fuse. Kinda surprised to hear the earth cable is naked just to save on material.
    Goes to show me not to overthink stuff.

  • @DeKempster
    @DeKempster 11 месяцев назад +4

    Interesting, earth conductors is a smaler size compared to L/N in the UK?

    • @UKsystems
      @UKsystems 11 месяцев назад +1

      it is because the protective device will engage and if not it will just get hot of it is in use

    • @efixx
      @efixx  11 месяцев назад +1

      Yep

    • @nickdobb2555
      @nickdobb2555 11 месяцев назад +1

      Yes, they're not normally current carrying so they don't need to be as big - only big enough to not get too hot during the relatively short duration of a fault to earth before the fuse blows or breaker trips or etc.

    • @ppdan
      @ppdan 10 месяцев назад

      Theoreticaly in nearly all failures the main RCD will trip before the earth conductor gets "overloaded".
      Our code here (Belgium) requires the earth to be equal or more.

  • @omega7311
    @omega7311 11 месяцев назад

    Brilliant well done

  • @jgharston
    @jgharston 10 месяцев назад

    Interesting. Yes, it will mean having to learn/get the habit of stripping the outer sheath differently. With a bare CPC I usually use the end-run method, cutting in lengthways from the cut end, running next to the CPC as a guide and pushing away from the adjacent sheathed conductor. Of course, this method would mean me de-sheathing the CPC!

  • @zoranstav3225
    @zoranstav3225 11 месяцев назад

    So you're just starting to catch-up to Australia and New Zealand? Good job...

    • @joansparky4439
      @joansparky4439 10 месяцев назад

      UK had "some form of" democracy for centuries while societal systems erode and become dysfunctional over such a time period..

  • @brianwood5220
    @brianwood5220 11 месяцев назад

    Somebody had to spend the R&D & Certification money at some point, even Irland have had something similar for years. Well done Doncaster Cables and best wishes for the sales of it.

  • @andygozzo72
    @andygozzo72 11 месяцев назад

    a very good idea 😊

  • @gmbs360
    @gmbs360 11 месяцев назад +1

    Delicious! Finally...

  • @iKidTutor
    @iKidTutor 10 месяцев назад

    As a German i would say we have this since the 60s/70s. Even in this old buildings where cables were placed underneath the wall Finish without ductwork around them. So save to say Ive never Seen anything Else in ny life used.
    So ofcourse we have single strain wires too. But in a context of your everyday Electro Installation this Basic 3x1,5m^2 etc is the Most Basic thing

  • @theawfulmrbird
    @theawfulmrbird 11 месяцев назад +4

    Living in a country which uses NYM-J cable i always wondered why twin and earth used bare copper as earth conductor. Nice to see that there is some progress.

    • @dorsetengineering
      @dorsetengineering 11 месяцев назад +1

      I was in a big DIY store in Germany recently - NYM-J was on the shelf in all the sizes, looked like a nice product.

  • @davidpinckney5595
    @davidpinckney5595 11 месяцев назад

    Hi, This type of cable has been available in Thailand for a number of years now

  • @babooXX
    @babooXX 11 месяцев назад +2

    Meanwhile in Europe, everyone has been using round cables with all conductors individually sleeved since even before the € became a thing you could touch.

    • @marcviej.5635
      @marcviej.5635 11 месяцев назад

      yea and flat cables have been banned long time ago too

    • @babooXX
      @babooXX 11 месяцев назад +1

      @@marcviej.5635 That's not actually true, you can still use flat cables (NYIF) but their use is discouraged and limited, must for example not be used in bathrooms and must be completely by plaster anywhere else.

    • @marcviej.5635
      @marcviej.5635 11 месяцев назад

      @@babooXXThat's possible where you are but here in Belgium flat cables won't pass inspection

    • @edc1569
      @edc1569 11 месяцев назад

      Why are round cables better?

    • @babooXX
      @babooXX 10 месяцев назад

      @@edc1569 That's mainly just preference; there's some minor technical advantages: round cables are easier to drum (you don't need to care about the orientation), and it's easier to drill a round hole and use a round grommet to clamp a round cable for tension relief than to find a way to do so with a twin'n'earth.

  • @1953Hardwork
    @1953Hardwork 11 месяцев назад +2

    Australia has been using twin + earth for years with a green and yellow insulated earth for 30 years plus.

    • @efixx
      @efixx  11 месяцев назад

      👍🏻👍🏻

  • @JezCunningham
    @JezCunningham 11 месяцев назад +3

    And which hand-strippers will do all three cores at once?

  • @dexwolfpack7919
    @dexwolfpack7919 11 месяцев назад +2

    not sure about this one to be honest i remember in my studies about this in electronics we looked at these cables as an example i was taught that the exposed earth increased the likelihood that if one line on either side was damaged it raised the chance that the cable would trip as sealing the grounding cable meant that if the outer shell of the cable was penetrated it reduces the possibility of a trip down to a 1 in 3 chance (this is bad as it it means if the cable is damaged by something it will only trip 1 in 3) reducing the efficacy of the trip from its current safety rating of nearly 80% down to 33% in this case i would argue this cable is easier to install no doubt but the safety concerns if damaged are higher

  • @gravyboat2370
    @gravyboat2370 10 месяцев назад

    Why has this not been done before !

  • @keacoq
    @keacoq 10 месяцев назад

    Is this the beginning of the end of bare copper earthing conductors in the UK? In France and NZ earth conductors have been insulated for decades.

  • @AngelLaHash
    @AngelLaHash 10 месяцев назад

    I did think it was bare because if there was any cut in the lines it touches earth first making it safer. Worse case live cable sleeve damaged , it now has an added protection from touching earth first .

  • @OH2023-cj9if
    @OH2023-cj9if 10 месяцев назад

    If only I could have had this in the 80s!

  • @brightspark0612
    @brightspark0612 11 месяцев назад

    Where there be an LSF ?

  • @Richard1977
    @Richard1977 11 месяцев назад +4

    First.
    Finally after all these 19 years of RUclips... ❤

    • @efixx
      @efixx  11 месяцев назад

      Congratulations

  • @drunkkmachine4511
    @drunkkmachine4511 11 месяцев назад

    🇨🇦 here - how much does a spool of 2.5mil 2-core+CPC cable cost on average from a wholesaler?

  • @olly7673
    @olly7673 11 месяцев назад +1

    It is a canny business move keeping the price the same and it may possibly help to take some the market share from the nasty imported rubbish from some Turkish and far east brands, as
    DC may now have the edge when putting convenience and quality over price. What is the situation with a LS0F version and what is the difference with this DC newby and Republic of Ireland's IS201-4: 2013 BASEC, BS EN 60338, they have been using since 2017 when they scrapped bare CPC? Also, how did the new DC T&E fare with the Quickwire flat cable strippers Gaz? The same or required a bit more effort?

    • @Ragnar8504
      @Ragnar8504 11 месяцев назад

      The DC stuff still has a smaller CPC, unlike the Irish cable.

  • @shanksgaming2827
    @shanksgaming2827 11 месяцев назад +3

    I’ve always said prysmian cable is the best to work with but if these new earth sure Doncaster cables are any good I might switch. 😮

  • @joansparky4439
    @joansparky4439 10 месяцев назад +1

    Been like that in Germany for DECADES.. and over here in Australia this is the norm for at least as long as well. And the UK only catching up now? OK, in the grand scheme of things - a couple decades give or take don't really matter.. but wow.

  • @pierer91
    @pierer91 11 месяцев назад +2

    As marine Electro Tech, all our cable comes with sheathed earth. Never understood why domestic stuff doesn’t 😂

  • @wpm720
    @wpm720 11 месяцев назад +1

    Nice to see that the new pre-sleeved will cost the same 🙌

  • @jeffhendon5506
    @jeffhendon5506 10 месяцев назад

    Was fitting this cable with covered earth in Australia in 2008/09. It's not NEW just never been offered here we're catching up at last !!

  • @jwillisbarrie
    @jwillisbarrie 10 месяцев назад

    Thanks for adding actual captions for the Deaf

  • @kobirelf97
    @kobirelf97 11 месяцев назад +4

    This is why I love Doncaster cables they are the number one cable company around now

    • @Doncaster_Cables
      @Doncaster_Cables 11 месяцев назад +2

      Thank you

    • @acelectricalsecurity
      @acelectricalsecurity 10 месяцев назад

      Are they?

    • @kobirelf97
      @kobirelf97 10 месяцев назад

      @@acelectricalsecurity yes

    • @acelectricalsecurity
      @acelectricalsecurity 10 месяцев назад

      @@kobirelf97 well the last time I used their cable when it was exclusive to cef, it was like chewing gum, and get to the end of the drum and the last several metres was useless, because it was all twisted and deformed.