The Secrets Of Making Electric Cables & Wires

Поделиться
HTML-код
  • Опубликовано: 8 сен 2024

Комментарии • 185

  • @JackBowley95
    @JackBowley95 2 года назад +15

    As someone who's not in the industry (but has done some basic training at college 10 years ago), I loved this video. Very satisfying to see a smart factory set up, but also great to see companies still taking pride in their work. Amazing.

    • @efixx
      @efixx  2 года назад +2

      Thanks 🙏

  • @nezbrun872
    @nezbrun872 2 года назад +5

    I'm a microelectronics engineer specialising in ultra low power applications in the nanowatt domain, but I still found this absolutely fascinating.

    • @Leo9ine
      @Leo9ine Год назад

      Huh, that's fascinating. What kind of things function in the nanowatt range? Sounds like really cool (and important) work too

  • @andysims4906
    @andysims4906 2 года назад +12

    I can remember when cable went metric .electricians at the time hated the fact twin and earth cable changed from stranded to solid cores. They soon got used to it though. But single conduit cable well into the 80s was available in sold or stranded core.
    Great video thanks

    • @raygale4198
      @raygale4198 Год назад

      Different standards in different countries, in Australia all domestic use cables over 1.0 sq mm are stranded, we also have an insulted earth conductor and our standard sheathed single phase twin and earth stayed as red and black cores, which personally I think was silly. Very interesting video, it's also good to see not all manufacturing has gone to Asia.

  • @ET-cj8jo
    @ET-cj8jo Год назад +1

    Wonderful presentation. No music (hooray!), just comprehensive and detailed explanation in clear English. Couldn't ask for better.

  • @MervynPartin
    @MervynPartin 2 года назад +13

    That was very interesting. I never realised how the cables were manufactured, so thank you (and Doncaster Cables) for your video.
    I do not regret the passing of 7/.029 like one of the comments, but I have always thought the previous colours of red, black and green were better. Then, 3-phase supplies were coloured red/yellow/blue. Simple and neutral remained black as in T & E. Even worse is the "50 shades of grey" in SWA.

    • @efixx
      @efixx  2 года назад +6

      Bring back the old colours

    • @randacnam7321
      @randacnam7321 Год назад

      As an American EE/DIY spark, can confirm that the old colors you used are way better than the new and are on par with our color code for ease of wire differentiation.

  • @HighWealder
    @HighWealder 2 года назад +1

    Glad to see we make some in Britain

  • @gbelectricks
    @gbelectricks 2 года назад +7

    I’ve worked with the stuff for years and years, but never seen the manufacturing process, very interesting to see. Great video efixx & Doncaster👏👏

  • @GSHElectrical
    @GSHElectrical 2 года назад +7

    What a fantastic video for new learners and electricians 👍🏻

    • @capactiveresistance314
      @capactiveresistance314 2 года назад +4

      This comment is like looking at a mirror in a mirror.
      Always happy to have Gary on my screen. Keep going, and thanks for the effort.

  • @muzikman2008
    @muzikman2008 2 года назад +6

    Enjoyed that! great video thanks 😎 love this stuff. I also like the fact you get an extra 1m of cable lol. All those saying "why don't they put a sleeve over the cpc? " it's because they have to make it to a British standard, regulations, thicker outer sheathing, conduit capacity, glanding, clips, etc.. and certification would all have a massive knock on effect of the price, and installation. would be nice though lol.

  • @kristiangoransson6104
    @kristiangoransson6104 2 года назад +6

    The cable manufacturers in Sweden has stopped using chalk to save our hands from drying up and not having to clean up the mess i makes. The newer types of cables are really easy to strip, often no problem to strip >1 meter of outer sheeting with minimum force

    • @efixx
      @efixx  2 года назад +6

      An alternative is to use a silicone based lubricant - we’ve had mixed results on cables which use this method.

    • @hayleyxyz
      @hayleyxyz 2 года назад

      I'd assume it would save you from potential lung damage too - silicosis I believe?

  • @2loco
    @2loco 2 года назад +4

    In Australia, we got rid of the bare earth TPS cable in the 1970s lol, and we don't use solid core anymore except on 1mm2

    • @efixx
      @efixx  2 года назад +1

      We like to stick to old ways - we converted from stranded to solid in the 1970’s

    • @2loco
      @2loco 2 года назад +1

      @@efixx 🤣🤣🤣

  • @drawingboard82
    @drawingboard82 Год назад +4

    What a fascinating video! Well done to you and Doncaster Cables. Especially glad to see the pride they take in their work. Hats off.

  • @JuneNafziger
    @JuneNafziger 2 года назад +1

    Super interesting, espescially, as a north american, to see how you have cables with chalk in them, here we have paper separating the different conductors!

    • @efixx
      @efixx  Год назад

      Thanks 👍🏻

  • @johnstancliff7328
    @johnstancliff7328 2 года назад +1

    this is so cool! I sold tons of this stuff back in the 1980's and 90's... here in North America we call the cable "Romex". This is such a neat video! Thank You Guys!

    • @efixx
      @efixx  2 года назад

      Cheers John

  • @drachirreisset
    @drachirreisset 2 года назад +1

    Narrator does a great job explaining the entire process.

    • @efixx
      @efixx  2 года назад

      That was Aaron he runs the show 👍

  • @Goatsmilkuk
    @Goatsmilkuk 2 года назад +3

    I used to work for CEF Doncaster cables was sadly one of the factories I didn't get to have a tour of. I did however handle a hell of a lot of cable from this factory during my time there. I still have half a roll of 1.5 and 2.5 in the shed.

    • @efixx
      @efixx  2 года назад +3

      Those rolls are an investment in the current climate 😃

    • @Goatsmilkuk
      @Goatsmilkuk 2 года назад

      @@efixx aren't they just. I remember 2.5 going for less than a tenner for 100 meters. Mind you it was over 20 years ago.

    • @petarnikolic998
      @petarnikolic998 7 месяцев назад

      Do you know what is the function of applying chalk ?

  • @ProfSimonHolland
    @ProfSimonHolland 2 года назад +1

    great to see high quality manufacturing

  • @Me-zo8yc
    @Me-zo8yc 10 месяцев назад

    When you're fighting to get the insulation off every single bloody core you come to appreciate a well made cable!

  • @brianwood5220
    @brianwood5220 2 года назад +2

    I love Doncaster Cable, there's nothing like it.

  • @JamesCurnowElectricalEngineer
    @JamesCurnowElectricalEngineer 2 года назад +3

    Interesting to see what goes into manufacturing cables.

  • @anthonyschofield7807
    @anthonyschofield7807 2 года назад +4

    One of the biggest secrets was how the manufacturers took the opportunity when metrication was introduced by moving from stranded to solid cores,they tried it with singles too but conduit wiring became almost impossible so they had to return to stranded,I’ll keep my 7/029 ring main cables thanks

    • @efixx
      @efixx  2 года назад +1

      Interesting

  • @mastergx1
    @mastergx1 2 года назад +5

    Interesting to see the process. I once had a reel of 1mm t+e cable where, on part of the reel, the neutal and cpc had managed to "switch places" within the sheath during manufacturing. The conductor order was now Line - Neutral - CPC. I didn't realise until I came to do my pre-test (end of 1st fix) and while it was a bastard to strip - it still passed cont and IR with flying colours so I decided to leave it in place (given that it would have been an extra 2 days labour to replace it). Anyone else ever had this issue? Never seen it before or since but now i''m super vigilant about it.

    • @andysims4906
      @andysims4906 2 года назад +4

      We used to get some crap cable from my wholesalers about 25 years ago .. Not through choice. It was called Wessel . Half way through the drum it would turn thin and even almost round. Full of kinks It wasn’t just a one off. It was still BASIC approved and tested ok.

    • @efixx
      @efixx  2 года назад +3

      We gave a sample of Kablo where this has happened.

    • @jjjannes
      @jjjannes 2 года назад

      WTF this cable is not usable, and should have been taken out.

  • @eddie_pegasus_electrical
    @eddie_pegasus_electrical Год назад +1

    Fascinating video. Love to see this live in the factory, tickles my coils this 😁
    👊😎👍💙

    • @efixx
      @efixx  Год назад +1

      🦾💕🦾

  • @pezzpezz7272
    @pezzpezz7272 2 года назад +43

    If only a manufacturer would make one with a sleeved earth, we need to catch up with the rest of the world.

    • @SuperSweetGamers
      @SuperSweetGamers 2 года назад +1

      It’s extra unnecessary costs though. Would only increase the price of work

    • @pezzpezz7272
      @pezzpezz7272 2 года назад +12

      @@SuperSweetGamers I’d quite happily pay the extra price, quicker installation time would far outweigh the extra 3 quid a drum

    • @muzikman2008
      @muzikman2008 2 года назад +3

      @@pezzpezz7272 really?... It's just a path to earth that needs a bit of sleeving on the end of a termination... 😉

    • @efixx
      @efixx  2 года назад +5

      Hank and Chuck across the pond don’t bother with sleeving

    • @muzikman2008
      @muzikman2008 2 года назад +1

      @@efixx "Hank & Chuck.." pmsl 😂👍

  • @bluebellelectrical
    @bluebellelectrical 2 года назад +3

    Great video, and really interesting to see how cable is actually made. Thanks Efixx team!

    • @efixx
      @efixx  2 года назад

      Thanks 👍🏻

  • @andrewcadby
    @andrewcadby 2 года назад +1

    Awesome video guys 👍

  • @thesavo
    @thesavo 2 года назад +1

    This is a wonderful video. I now know that it's chauk running out cable's when they are terminated. I have wondered what that was.

    • @thesavo
      @thesavo 2 года назад

      We don't have that in US residential cable. Maybe a collaboration with electrician u channel on the differences of UK and US power systems and standards.

  • @DrGenestealer
    @DrGenestealer 2 года назад +3

    Wow, 8:53 high voltage dielectric testing limit of 6 amps! That's a lot of leakage, but, then again, that's a large tightly wound coil.

    • @arcadia1701e
      @arcadia1701e 2 года назад +1

      That would be inductance of the coil surely .

    • @nirodper
      @nirodper 2 года назад +1

      @@arcadia1701e If it is AC it is the effect of capacitance, there's no current through the conductor for inductance

    • @rbland
      @rbland 2 года назад

      There must be a load on the other end. Probably a high voltage and current test all in one. I wouldn't have thought there could be this much leakage current. with all that insulation.

    • @nirodper
      @nirodper 2 года назад +3

      @@rbland There isn't a load on the other end, there would be no point in doing that.
      With a wire diameter of 1.4mm, a separating distance of 2.5mm and a pvc dielectric constant of 3 I've calculated a capacitance of 70pF/m, so at 10km of wire and 50hz there's an impedance of ~4550Ω, giving a current flow at ~3kv of 0.65 amperes.
      Purely capacitive.

  • @jim2757-w8m
    @jim2757-w8m 2 года назад +2

    Fascinating. 👍

  • @user-go2ed5zx5x
    @user-go2ed5zx5x Год назад

    interesting process manufactur.

  • @SirHackaL0t.
    @SirHackaL0t. 2 года назад +1

    Excellent video. More of these please. :)

    • @efixx
      @efixx  2 года назад +2

      On it

  • @iknowmyfootball3901
    @iknowmyfootball3901 2 года назад +2

    Brilliant video more like this please

  • @raindropsrising7662
    @raindropsrising7662 Год назад

    Super awesome to see the process. Love it. Thanks for putting this educational piece together.

  • @robertfraser9551
    @robertfraser9551 2 года назад

    Excellent video. Commentator very good. Impressed by the whole sequence. Obviously a lot of engineering and tradecraft has gone into the product !!

  • @carlubambi5541
    @carlubambi5541 2 года назад +1

    Similar process in Canada .We call it Romex .We do not make Romex with an isolated ground but do make BX Armoured cable with isolated ground .Used for Data Communications and hospital environments..Most cash register systems in groceries stores will use isolated grounds as each till and computer will have an independent UPS

    • @efixx
      @efixx  2 года назад +1

      Interesting would be good for us to get hold of some to compare. 👍

    • @carlubambi5541
      @carlubambi5541 2 года назад +1

      @@efixx pretty much the same thing we use 14 or 12 gauge for most residential applications .We also have a heavier jacketed version with the NMW-U rating .Non metallic wreathed proof and underground rated .It can be run on the surface above 1 meter without mechanical protection or underground .the insulation is almost 3 times the diameter of the conductor and the ground wire is the same ,bare . Armoured cable comes in various configurations .Lead core aluminium spiral and PVC inner or outer jacketed cables .Tech cable is a brand name can be a single conductor or multi conductor .Shielded or unshielded .The sky is the limit and so is the price .Some we use are over $8 Canadian a linear l foot /Or everything now is metricated .Dont know metric ,not conduit nor wire sizes .AWG ,Kcmil and MCM .,1/2,3/4 ,1, 11/4, 2 inch 3 inch and 4 inch conduits .Never used metric except in school and European equipment .Construction for us as always been imperial inches and thousands of an inch for machinery .

  • @jenseng8977
    @jenseng8977 Год назад

    Great video!!

  • @robertkat
    @robertkat 2 года назад

    Here in USA all housewiring is 14 gage, water heater 12 gage, white in neutral, black is hot. Easy to see. Blue , red and yellow for 3 phase .

  • @kjamison5951
    @kjamison5951 2 года назад

    Fascinating video but when I went to click on the video link at the end, it cut straight to an ad. Maybe leave the links on screen for a little longer next time.

  • @synthwave7
    @synthwave7 2 года назад +2

    Here is South Africa our twin and earth wires are black and red inside not blue and brown. Also - what is the function of the talc powder ?

    • @efixx
      @efixx  2 года назад +2

      We used to have the same colours before we harmonised with Europe. French chalk stops the inner cores sticking to the outer sheath.

  • @ianbakke
    @ianbakke 2 года назад +3

    What always surprises me is that the UK twin and earth allows smaller conductor for PE/CPC. This would never be allowed in the Scandinavian/Nordic countries, where the earth has to be the same area, or equivalent conductivity.
    Although we allow plastic consumer units, open ends on surface mounted plastic conduit without requirement to bend it with the cable showing out in the corners…

    • @___AD
      @___AD 2 года назад +2

      Like Ring Circuits it's a hangover from the War when they were trying to save copper.

    • @apk55
      @apk55 2 года назад +8

      The earth wire should never carry current except in the case of a short duration pulse (until the MCB trips) of a line to earth fault. Therefore it only needs to be big enough for this requirement.

    • @ianbakke
      @ianbakke 2 года назад

      @@apk55 Good point… but what if the fault current wouldn’t be enough to trip the circuit breaker, let’s say if the cable were to be quite long? Nowadays when an RCD is installed I guess it wouldn’t be an issue, but what if the RCD was faulty?
      I know this is very unlikely to be a problem but I think it’s just interesting to see how we do it differently.

    • @ChooseLife.YourLife
      @ChooseLife.YourLife 2 года назад +2

      @@ianbakke if the cable is too long for the size of the conductor to safely trip the mcb then the apprropriate larger size will be chosen.

    • @namibjDerEchte
      @namibjDerEchte 2 года назад +1

      @@apk55 The earth here in Germany has to be large and low resistance enough to clamp the fault current to a safe enough voltage in absolutely all situations. Which is hard to do if you get a line-to-earth short at the end of any disstance of cable run with the earth being a thinner conductor.

  • @jamesswinyard530
    @jamesswinyard530 2 года назад +3

    How many times did Gary want to say "Twin and CPC"?
    Great insight into what it takes to make some quality cable though!

    • @efixx
      @efixx  2 года назад +1

      You can feel his pain 😂

  • @jix177
    @jix177 2 года назад +1

    Fascinating - you'd certainly need your wits about you to walk around that factory, not a good place for loose clothing or trailing jewellery, etc!! Thanks for sharing.

    • @efixx
      @efixx  2 года назад +1

      Yes lots of fast moving parts

  • @tomschmidt381
    @tomschmidt381 2 года назад

    Interesting watching the manufacturing process. Cable looks similar to UF (underground feeder) cable on this side of the pond. Typical indoor flexible cable in the US NMC (Romex) has paper between the conductors and outer jacket. I was surprised by the wire twisting process on larger gauge, I was expecting to see the take-up spool being rotated.

  • @tincanpete
    @tincanpete 2 года назад +1

    That was super interesting, thanks!

    • @efixx
      @efixx  2 года назад

      Thanks 👍🏻

  • @cemprotecta
    @cemprotecta 2 года назад +1

    How interesting! Thanks for sharing.

    • @efixx
      @efixx  2 года назад

      Thanks 👍🏻

  • @lawrencer25
    @lawrencer25 2 года назад +1

    Fabulous video 👍👍👍

  • @Slikx666
    @Slikx666 2 года назад

    That was interesting. 🤔👍

  • @kalipsokasparo8328
    @kalipsokasparo8328 Год назад

    Perfect

  • @marcr1333
    @marcr1333 2 года назад

    How do you guys put new wire into the shrinker? Would assume it’s hard to put fresh line into it, given the diameter.

  • @anthonyschofield7807
    @anthonyschofield7807 Год назад

    And when we went metric the manufacturers seized the opportunity to go from stranded to single core which benefitted them but caused problems for electricians,particularly in conduit wiring so single soon returned to stranded.Unfortunately T&E was left with solid conductors making it stiffer and less easy to ensure the tightness of tunnel terminals.7/029 was superior to 2.5 in every respect

  • @PSM-IPADZ_OX
    @PSM-IPADZ_OX 2 года назад +1

    Any technical reasons or otherwise, are the drums of the cooper need to be of 8mm in diameter ? Just curious
    Couldn’t the cooper wire manufacturer produce them in different diameters needed for different purposes and sell them to electric cables producers the exact diameter that they need ?
    Side question - is similar manufacturing process of drawing out the raw copper cables into different diameters apply to making cables for the audio visual industry too ?

    • @efixx
      @efixx  2 года назад +2

      It’s a standard that copper rod is sold for cables.

    • @efixx
      @efixx  2 года назад

      Will be same process for AV

    • @PSM-IPADZ_OX
      @PSM-IPADZ_OX 2 года назад

      @@efixx thanks so much for the answer

    • @PSM-IPADZ_OX
      @PSM-IPADZ_OX 2 года назад

      @@efixx noted and thanks

    • @benjamindesson5326
      @benjamindesson5326 2 года назад

      It will be because it's the standard but also because it means that the cable manufacturer has greater control over the drawing and annealing. Relying on a supplier to manufacture to the standard you want can complicate things, for example if demand shifts or equipment goes down you wouldn't be able to shift production until the new wire works its way through shipping.

  • @jimgeelan5949
    @jimgeelan5949 2 года назад +1

    Wow wow wow you can now see why ENGLAND are so good at all things creative, not just football ~( go for it girls)

    • @2loco
      @2loco 2 года назад

      Ok

    • @efixx
      @efixx  2 года назад

      🇬🇧

  • @scroungasworkshop4663
    @scroungasworkshop4663 2 года назад

    Very interesting, What happens to the copper paste in the machines?

  • @hypeheat5197
    @hypeheat5197 2 года назад

    Very cool 👍

  • @AlexanderBukh
    @AlexanderBukh 2 года назад

    Great view into the process, thanks!

  • @willgallatin2802
    @willgallatin2802 2 года назад

    Different colors used here in the US, but The end product looks to be physically the same. US wire is normally certified for 600 VAC for this type of cable. Anyone know what it is in GB?

  • @BradBo1140
    @BradBo1140 2 года назад

    I’m curious to see how the automated 100 m reeling machine cuts and switch’s to a new drum? The big one had a person doing it.

  • @Bari_Khan_CEng_CMarEng
    @Bari_Khan_CEng_CMarEng Год назад

    Great video and insight.
    What exactly does the chalk do for the pvc inner core?

    • @Me-zo8yc
      @Me-zo8yc 10 месяцев назад +1

      Makes it easier to strip.

    • @Bari_Khan_CEng_CMarEng
      @Bari_Khan_CEng_CMarEng 10 месяцев назад +1

      @@Me-zo8yc cheers, I bought some Doncaster Cable, and it was super chalky!

    • @Me-zo8yc
      @Me-zo8yc 10 месяцев назад +1

      @@Bari_Khan_CEng_CMarEng Yeah, exactly that - if that chalk isn't there the different layers just get stuck to each other and especially if its on an existing older circuit that's had some use (And therefore heat) it can be literally impossible to remove the out sheathing! On a new install it's generally just irritating and a waste of time - you have to do it at each and every point!

  • @Dog-whisperer7494
    @Dog-whisperer7494 2 года назад +3

    Wow what a brilliant video.
    I found this very interesting,
    One question though if the cable is tested to 3KV for five minutes why is it when we get it it’s only rated to 250V? . Gaz this is one of you’re best videos more like this please.
    Brilliant video Gaz as always 👍👍👍👍👍👍👍👍❤️❤️

    • @FistralG
      @FistralG 2 года назад +1

      The test current was a lot lower than a typical domestic circuit.

    • @MatSmithLondon
      @MatSmithLondon 2 года назад +3

      @@FistralG he said “the high-voltage test procedure will test each core to every other metallic component within the cable”. Also he mentioned the voltage was applied for a period of time. Therefore this appears to be a “dielectric withstand” test. The idea is that no current is flowing.

    • @FistralG
      @FistralG 2 года назад +1

      @@MatSmithLondon There was a small current displayed on the screen. My point still stands it’s not tested with a high voltage and high current. That’s why it’s only rated to 250v in real life use.

    • @Dog-whisperer7494
      @Dog-whisperer7494 2 года назад

      @@FistralG I still can’t get it.
      I understand current carrying capacity of cables, what I don’t get is irrespective of the current, if the cable is tested to 3KV then surly it would be rated to 3KV why is it only rated to 250v , even if it was rated to 3KV if to much current flows through it it will overheat and melt . Also if it’s rated to 3KV then it will have a much higher current carrying capacity making it ideal for domestic installations as we wouldn’t have to worry about over loading and fires ?

    • @muzikman2008
      @muzikman2008 2 года назад +6

      @@Dog-whisperer7494 It's an insulation resistance test. HV is used at very low currents, as you would do with a IR tester on testing a final insulation, but only to 500V or 1000V on a multi tester, If it passes a test in the factory of 3KV then it will certainly pass an IR test after installation and test. It's "headroom" for its capability of IR.

  • @PissShiversss
    @PissShiversss 9 месяцев назад

    Does anyone know how they make the individual strands of a 1000ft 22 gauge wire? It's pretty easy to make 1 mil wire from 8 mil rod...

  • @MatSmithLondon
    @MatSmithLondon 2 года назад +1

    Is heat applied during the process of reducing its size?

    • @efixx
      @efixx  2 года назад +1

      No - just heated after drawing during the annealing process.

  • @nannesoar
    @nannesoar 10 месяцев назад

    Thank you for using your resources to educate, eFIXX

  • @FistralG
    @FistralG 2 года назад +1

    I only need a few meters to get another light in the porch! Do they do shorter lengths?

    • @efixx
      @efixx  2 года назад +5

      See Screwfix 😄

    • @Goatsmilkuk
      @Goatsmilkuk 2 года назад

      Most wholesalers such as CEF do it cut to length as do DIY stores.

  • @scratchpad7954
    @scratchpad7954 2 года назад

    Is Romex an example of a twin and earth cable?

  • @robertkat
    @robertkat 2 года назад

    Also all wiring was solid, mutch easier to work with.

  • @donmar6156
    @donmar6156 2 года назад

    Hey thanks for sharing I live in the caribean and never saw dual earths before.
    Could you explain the reason.
    Also another question would be why have we moved from red and black to blue and brown

    • @efixx
      @efixx  2 года назад

      We changed colours to harmonise across Europe.

    • @donmar6156
      @donmar6156 2 года назад

      Thanks

  • @ShahedAhmed-er4ih
    @ShahedAhmed-er4ih 2 года назад +1

    What purpose does the chalk serve?

    • @efixx
      @efixx  2 года назад +4

      It stops the inner cores sticking to the outer sheath.

    • @2loco
      @2loco 2 года назад

      For writing on chalk boards

  • @ahmedelectricianofiraq5550
    @ahmedelectricianofiraq5550 2 года назад

    Why the twin & earth cable made flat why not like around cable?

    • @efixx
      @efixx  2 года назад +1

      Would be a waste of material

  • @acespark1
    @acespark1 2 года назад +1

    If the cable is IR tested at 3kv how many times can it withstand an IR test above 1kv after that ? Only asking as I have carried out IR testing at 5kv and could only perform that test once. After that any more HV testing would destroy the cable.

  • @MrBobWareham
    @MrBobWareham 2 года назад

    Thank God it is not made in China, as we would end up with crap wiring in our homes and not the real thing! Nice to see we still make something in the UK

  • @skellious
    @skellious 2 года назад +1

    where's the corner cutting video?

    • @efixx
      @efixx  2 года назад +2

      Link at the end of the video

    • @herrtomas6729
      @herrtomas6729 2 года назад

      ruclips.net/video/JvJuqgBasuY/видео.html

  • @PissShiversss
    @PissShiversss 9 месяцев назад

    I'm gonna make a video titled "How A Chevrolet Tahoe is Made" and its going to go like this... "So we're going to start with a Chevy Suburban and make it smaller, then paint it"

  • @MrJef06
    @MrJef06 2 года назад

    I'm not an electrician but I've never seen this type of cable, is it a British thing? AFAICT here in France the earth lead is always identical to phase and neutral except for the color of course (yellow and green)

    • @efixx
      @efixx  2 года назад

      It’s a very British cable

  • @steves009
    @steves009 Год назад

    Why is British cables Earth core Unshelled?

  • @xdev_henry
    @xdev_henry Год назад

    Actual question: What happens with all the copper that is taken away in this 8mm to 1mm conversion process?

    • @efixx
      @efixx  Год назад

      The cable is stretched or “drawn” so no material is wasted the width is converted to length

    • @xdev_henry
      @xdev_henry Год назад

      @@efixx Oh alright, we’ll that’s answering that. English isn’t my main language so that explains the misunderstanding 😅

  • @christopherhume8896
    @christopherhume8896 Год назад

    Now you need to do a video on the biggest electrical question, to twist or not to twist? So many sparks, even on RUclips, don't seem to twist cores anymore, they just shove the ends in and hope the screw catches both as if they're a plumber. When I was an apprentice behaviour like that would have got your toolbox screwed to the floor. 🤣

  • @hmmmnz
    @hmmmnz 2 года назад

    coming from nz, the non insulated earth has always annoyed the bajesus out of me.
    ive gotten used to it being solid instead of stranded, and in some ways i actually think thats better,

  • @theoldbigmoose
    @theoldbigmoose 2 года назад +1

    I always thought the color of the cables is reversed. So easy to remember if blue was the hot or the sky, and brown was the return or ground, like in dirt. Anyone know how these colors were originally determined?

    • @efixx
      @efixx  2 года назад +1

      A good question for many years in the UK we used Red & Black before Europe decided to harmonise conductor colours.

    • @yuk-erkmckirk9277
      @yuk-erkmckirk9277 2 года назад +1

      we still use red & black in australia, only appliance cord and leads have blue & brown sleeves. i think the colour change was for colour blind people because when i did my apprenticeship you couldn't be a sparky if you were colour blind. and apparently only men get this ,most sparkies were men back then so testing was necessary because multicore cables can have lots of colours in them that can be mixed up by being colour blind.

    • @topend70
      @topend70 2 года назад +2

      Red and black can cause issues with people that are colourblind. Apparently blue and brown can be distinguished. Always remember you would not touch a turd and they are brown.

  • @leonardhall7203
    @leonardhall7203 2 года назад

    I know I'm just an American. But what is the powder in the wire? Our electricians here would never go for that. I know they are allergic to brooms and vacuums so that would definitely not help things for them.

    • @efixx
      @efixx  2 года назад

      Ha 😂 it’s French chalk it makes the cable easier to strip. The inner conductors don’t stick to the outer sheath.

  • @salix.h6923
    @salix.h6923 4 месяца назад

    Factory ODM OEM Copper electric Power Wiring Cable BVR/BV 2.5mm 4mm 6mm 10mm Single Core Flexible electricity wires and cables

  • @robintodd3901
    @robintodd3901 2 года назад +2

    Give me prysmian any day.

    • @efixx
      @efixx  2 года назад +1

      What’s the difference?

    • @robintodd3901
      @robintodd3901 2 года назад

      @@efixx prysmian is far better to work with and strip.

  • @dafalzonAUS
    @dafalzonAUS 6 месяцев назад

    stop winding me up😂

  • @werre2
    @werre2 2 года назад

    the best part was when they were making cable

  • @simonp.5959
    @simonp.5959 2 года назад +1

    In der EU abspult verboten, sogar streng verboten!!

  • @raymurphy9749
    @raymurphy9749 2 года назад

    So I can't knock up drums of 2.5mm in my shed then 😂

    • @efixx
      @efixx  2 года назад +1

      This place isn’t far off a shed ruclips.net/video/zepldzNnaAU/видео.html

  • @ledsalesoz
    @ledsalesoz 2 года назад

    Interesting vid, but I find it ridiculous that most cables are still PVC. It is one of the most toxic plastics to manufacture, is not easily recyclable, and indeed in many countries they simply burn big piles of cable to remove the PVC and get the copper for recycling, producing some seriously toxic pollutants like dioxins and furans in the process. Given that there are better alternatives, like synthetic rubbers which are less toxic, tougher and more heat resistant, it's hard to see why PVC is still the dominant sheathing material other than it's cheaper. But, I guess it all comes down to price in a capitalist society, things that actually matter like environmental issues always come last...

    • @efixx
      @efixx  2 года назад +1

      The scrap people would still burn rubber to extract the copper. Most underground cables are XLPE.

  • @christ9460
    @christ9460 2 года назад +1

    to make 1.5 or 2.5, an awful lot of copper was wasted

    • @efixx
      @efixx  2 года назад +2

      They waste very little

    • @christ9460
      @christ9460 2 года назад

      from 8mm copper and reduce it down to 2.5mm, there is a lot that is ground away, with diamond 00:20

    • @nirodper
      @nirodper 2 года назад +2

      @@christ9460 you don't understand what drawing wire is

    • @emilmuhrman
      @emilmuhrman 2 года назад +1

      @@christ9460 It's not ground away. It's stretched.