What part of the duct does it install in.Before the air enters the furnace/ac,but after the air filter or after the air passes through the furnace/ac but before it enters the ducts to the different rooms in the house.Also how many wires from the Air Scrubber connects to the power supply.
It mounts downstream of the air handler in the supply air duct with a minimal duct size of 9x9” metal or 10x10” duct board. Two wires 24vac supplied by a two wire conductor and preferably on its own 40va transformer.
I know u posted this a year ago but if anyone else is wondering it's 24 Vols so you can wire it right to the board or if you have like a zone control board already being powered off the board you need to add a 110v to 24v transformer
I just had this installed yesterday. The HVAC tech said to leave the fan on low setting to circulate the air, thus "cleaning" the air as it passes through the Air Scrubber. By the way, my unit is installed on a Carrier Infinity system.
Best explanation I seen so far! Great job !
The information in this video is better than what the company itself puts out. Kudos!
What is the name of the air scrubber you are recommending?
What part of the duct does it install in.Before the air enters the furnace/ac,but after the air filter or after the air passes through the furnace/ac but before it enters the ducts to the different rooms in the house.Also how many wires from the Air Scrubber connects to the power supply.
It mounts downstream of the air handler in the supply air duct with a minimal duct size of 9x9” metal or 10x10” duct board.
Two wires 24vac supplied by a two wire conductor and preferably on its own 40va transformer.
Hi, can I let the air scrubber run without ac or heater on? Because I cannot turn it off OR (do you know if I can make a switch to turn it off.)
Will it also clean the evaporator coil?
Do you know if this can be installed with a fujitsu or Daikin multi zone mini split. ?
Can you share what type of power supply comes with this? Is it a hard wire to the HVAC unit or plug into an electrical outlet? Thanks
I know u posted this a year ago but if anyone else is wondering it's 24 Vols so you can wire it right to the board or if you have like a zone control board already being powered off the board you need to add a 110v to 24v transformer
Should I run my fan 24/7 to clean my home around the clock and not just when the a/c comes on?
YES
I just had this installed yesterday. The HVAC tech said to leave the fan on low setting to circulate the air, thus "cleaning" the air as it passes through the Air Scrubber. By the way, my unit is installed on a Carrier Infinity system.
I have an Air Scrubber 2000 now. Can I replace it with this model? Where can I buy it?
I think it has to be sold through a licensed HVAC tech
I just gave you 56 subscribers