How to connect two Inverters in parallel.

Поделиться
HTML-код
  • Опубликовано: 17 окт 2024

Комментарии • 41

  • @sandfordstebbings125
    @sandfordstebbings125 4 месяца назад

    What about two different size inverters? How do you dictate the inverter size in Simulink. How do you get two inverters that are different sizes to supply same % of power?

    • @pmctech1415
      @pmctech1415  4 месяца назад

      Connecting inverters of different sizes in parallel is not recommended as it may cause imbalance and inefficiency in the system.
      If you do proceed, it is important to ensure that they have similar voltage and current ratings.

    • @sandfordstebbings125
      @sandfordstebbings125 4 месяца назад

      @@pmctech1415 I have gotten some value from your videos. I like them, but you are not correct here. Happy to discuss with you. I am working on a simulink model right now where two different size inverters are connected together and operate well. Send me a message if your interested.

  • @svaditya2896
    @svaditya2896 Год назад

    For DG1 how did you get the U ref:P function block ( after reactive and active power control)

    • @pmctech1415
      @pmctech1415  Год назад

      Hi, I am sorry I can't get your question. Would you rephrase it?

    • @svaditya2896
      @svaditya2896 Год назад

      @@pmctech1415 What is the load you have given to DG1 and DG2?
      Can you please show it on the system?

    • @pmctech1415
      @pmctech1415  Год назад

      @@svaditya2896 R=20ohms and L is 1mH for both DG1 and DG2

  • @svaditya2896
    @svaditya2896 Год назад

    Why is Iabc incompatible to VI measurement (3 phase) block?

    • @pmctech1415
      @pmctech1415  Год назад

      Would you kindly rephrase your question?

  • @ramazankeser1531
    @ramazankeser1531 Год назад

    Hi, what is the value of the series RLC load after the circuit breaker?

    • @pmctech1415
      @pmctech1415  Год назад

      Hello. Thank you for watching. R=20ohms and L is 1mH for both DG1 and DG2

    • @ramazankeser1531
      @ramazankeser1531 Год назад

      @@pmctech1415 no I mean the serıes rlc load after the circuit breaker

    • @mohaamoha9272
      @mohaamoha9272 7 месяцев назад

      Hi did you make this simulation yet​@@ramazankeser1531

  • @zakariaafshar5330
    @zakariaafshar5330 Год назад

    Why the active power-sharing is poor? Can you change the droop gain so that one inverter produce power two times more than the other inverter?

    • @pmctech1415
      @pmctech1415  Год назад

      Hello, sorry, I don't think i fully understand your first question. On the second question, yes, you can, but you might be stressing the inverter that is supplying more power than the other.

  • @meghadua8965
    @meghadua8965 Год назад

    Can you please explain the DG1 and DG2 subsystem.

  • @josuehernandez4230
    @josuehernandez4230 5 месяцев назад

    Could you please share the simulink file?

  • @feyikemiodesanmi1099
    @feyikemiodesanmi1099 Год назад

    please can you open the 3 phase load 1 an 2 subsystem, i dont know how to build it

    • @pmctech1415
      @pmctech1415  Год назад

      Inside the subsystem is an rl load with 50ohms resistance and 1mH inductance

    • @feyikemiodesanmi1099
      @feyikemiodesanmi1099 Год назад

      @@pmctech1415 what other blocks are in there but that
      could you please send me a screenshot

    • @pmctech1415
      @pmctech1415  Год назад

      @Feyikemi Odesanmi Hi, the only block that was not opened is the load. The other subsystems were opened. Unless otherwise, you can send me the screenshot.

    • @feyikemiodesanmi1099
      @feyikemiodesanmi1099 Год назад

      @@pmctech1415 it’s the load I’m referring to , like can I get the screenshot of the internal of the subsystem of the load , I don’t understand your other reply of just resistance and inductance

    • @pmctech1415
      @pmctech1415  Год назад

      @Feyikemi Odesanmi yes please that is the connected rl load, which I am referring to as resistance and inductance. I hope you get me now.

  • @arifazim4495
    @arifazim4495 Год назад +1

    Can You give Simulink file of this video

  • @VishalKumar-ic7su
    @VishalKumar-ic7su Год назад

    Could You please open the subsystem of (three phase load 1 and 2 )

    • @pmctech1415
      @pmctech1415  Год назад +1

      There is R=20ohms and L=1mH in both

    • @svaditya2896
      @svaditya2896 Год назад

      @@pmctech1415 What kind of load is that? What all blocks have you put?

  • @GaryRey-fq9oz
    @GaryRey-fq9oz Год назад

    Can you plz share the simulink file

  • @engqudratnwpu9094
    @engqudratnwpu9094 Год назад

    can you plz share simulink file here or on github

  • @SHAYANIRSHADKHANEEB
    @SHAYANIRSHADKHANEEB Год назад

    Can you please share simulation file with me?

  • @sujoybhowmik2341
    @sujoybhowmik2341 6 месяцев назад

    Hello ! really its amazing. Can you please share the simulink file to my email?

    • @pmctech1415
      @pmctech1415  6 месяцев назад

      Thank you for watching. Kindly email at pmctech1415@gmail.com

  • @THISisNICE135
    @THISisNICE135 4 месяца назад

    Can you please share the simulink file.

    • @miladamiri9442
      @miladamiri9442 2 месяца назад

      Please accept my request to give file

  • @feyikemiodesanmi1099
    @feyikemiodesanmi1099 Год назад

    please can you share the simulink file

  • @KRISHNAYADAV-yw2ix
    @KRISHNAYADAV-yw2ix Год назад

    Could you share simulink file