Indian brand mein shayad yahi controller 90/95% solar panel se output extract karta hai. Baki k sare to 50/60% se jyada extract nahi kar pate. Aur hamare anadi youtuber dc to dc buck converter function ko mppt function bata dete hain ya to inhe pata nahi hai mppt hota kya hai ya fir ye sponsored video banate hain. In anadiyon ki wajah se maine utl controller liya jiski solar efficiency muskil se 60% hai.(500 watt k panel se 300 watt se jyada power kabhi mili hi nahi) Aapki video dekh kar is cintroller ki solar power extraction efficiency pata chali. Good job sir. Agar ho sake to amberroot mppt controller ki solar efficiency ki vidro banaiye taki log ek good controller k bare mein jaan saken. Regards,
Sir maine apna inverter change kr dia hai pehle 12 volt ka tha ab 24 ka laga dia hai or battery ke connection series main kr diye hai Mere paas 900 watt ke panel hai 100 ×9=900 3 ka set banaya hai total 3 string banai hai to ap bataiye ki panal 24 volt ke hisaab se kam hai ya thik hai Or ek baat ashapower surya ki settings mai 24 volt system pr battery ah settings kitne pe rakhni hai 150 ah par ya 300 ah pr And one more question sir usar manual pr no 8 ke settings cal amp ki jo hai usme maine 160 tak rakha hai jitna vo maximum hai to thik hai ??? Thx respectable sir Sabhi questions ke ans details de dijiye plz ap se yehi umeed hai thx
Panel ki voc bato kitni hai? 8 no. Settings nahi change karni es se aap ki display flash amp ki reading dene lagg jaye gi vo ontni hi rakho jo pehle thi je to calibrate karne ke liye hoti hai. Agr do battery 150 + 150 ah ki series mai laggi hai to 150ah hi setting karni hai 300 pe nahi
@@sandhuztech4465 thx Panel ki voc 60 hai teen string ka mila ke 15 amp aata hai 8 no ki settings pehle 133 pr thi vo minimum 110 pr jaati hai or maximum 160 pr to maine 160 rakhi hai Agar kam krta hu to ampere kam dene lagta hai To kiya 133 pr rakhu ya kiya kru Or kiya panel kam hai or lagane ki jaroorat hai ya nahi
@@gurbaniras8601 ek panel 100 watt ka or buy karlo or 5+ 5 ki do string banna ke laggao results jadda ashe aye ge Ja fir 6 panel series mai chala ke dekho aap ko results ashe mile ge 8 no. Wali settings 130 pe kardo ja agr aap ke pass dc ampere check karne meter hai charging amp. Meter ke or display ke same hone chahiye aagr kam jadda hai to es 8 no. Settings se sett karo
Very good information, but I connect 2 solar panels of 440 Watts on one battery (along with this Solar Charge Controller). It was working fine from last 3 days but now, the display of MMPT Solar Charge Controller gone. Can you help me in this regard? Any help will be appreciated. Thanks!
Je work battery voltage pe karta hai but inverter ki main control karne ke lei vo line es ko dena parhta hai agr app only solar se battery charger karna chate hai to es ke bina bhi kaam chal jae ga
Hello 👋 sir muje is se badea ambrroot rehub 12vand 24v 40amp smu laga keo k panal se ketne vi amper Ae magar bo 18 amper se jeada nahe Jane data battery ko
Amberrot asha hai per efficiency kam hai Har bande ki aapni choice hai koi kis chij ko preference deta hai koi kisi or ko so je amberrot bhi best hai efficiency ko chod ke aagr aap ki battery time rehte charge hi na hui to kya feda es ko voc max 90 hai Ek video es ki smarten ke 2500 va ke sath comparison ki banni hai vo dekh lena Thanks for comment
very informative video sandhu ji . I am going to install my off grid solar system and I have purchased the neon 60 asha power charge controller i have two battery system of inverter with 2500 va can you suggest me how much wattage of solar panel I should install and daily on an average I use atleast 13 units .
Me 1800 watt ka 180 watt × 10 pannel lagaya hnu , aur mera 10 am pe 81 Ampare ,nikal raha he , asapower neon 80 lv. 220 ka 2 battery aur 12 volt inverter me chal raha he , aur abhi problem yee he ki jyada dhuup me display blank ho ja raha he, aaab yaa karu ???? Kuch suggestions dijiye
Sir Mere pass 390watt ke 4 panels lge hai jo waaree company ke mono perc hai or maine ispe ethan 60a charge controller lga hai or maine 4 battery ko 24v pr use kr ra hu but meri battery full charge nhi ho rhi hai kya kru mai
Sir ji inverter pe ampere meter lagane se kuch volt ka drop aata h ...jis se inverter ki battery output 14.60 ho jaygi lekin battery terminal ki 13.60 hogi ...or inverter charging me malfunction karega ....shunt wala ampere meter use Krna chahea ...ye coil wale voltage drop krte h ...
@@arnabkumarmondal510 epro matt lena Agr budget hai to hybrid inverter lo Jo on gird and off gird ch sakke aaj kal cellcronic ka hybrid best manna ja raha hai
Bhaiji mene surya 60 model lagaya hai or 390 watt ke 2 pannel mein wo to itna 76 volt se 8-9 AMP hi same climate mein charge kar raha hai aap ka mppt to 19 amp kaise kar raha hai???
@@Manishkumar-dj6kl battery voltage aap set kar sakte hai man lo aap ne chahte hai battery voltage 13v hone pe je aap ka load solar se chalane lagge ga
charging current limit karo 30A tak by seeting the battery ratings under settings. 2. Select option "1" for limited ampere charging up to the set value of 7th menu. (7.GRD-SOL) ( Grid to Solar shifting volt 14.2V default) When kept in this mode MPPT delivers only 30 amps of continuous charging current to the battery if the Ah is set to 150 and delivers the maximum available ampere to load and battery charging after shifting to solar power.
Right sir i know this setting but problem is here when load shift ed to solar then start limited charging if our load required more then 30amp and our panel have capacity to till 40amp but we select limited charging option and we can use only 30amp If have any more solutions want to shoot th video on this topic so please tell us
@@sandhuztech4465 Q: If the charging current configured to 30 amp, using 2000 watt panels for 24 volt battery bank, atmax. Are remaining amp willbe wasted?or use ac load A: 30 amp is the maximum amp that will be used for charging. If your batter is running with the full charge, Amp will be directly proportional to the load connected. If load is more , more ampere will be shared. Battery charging will be done only as per the requirement. By ASHAPOWER on 14 September, 2020 Contact Ashapower and they will guide you for the exact settings needed.
@@Ninja.9777 I already cantact to Ashapower care but their is no solution Why you spouse max Ampere is 30 amp My mppt neon 80 give me maximum Ampere till 42 so what you say about this condition
sir.. surya 60 me penal se 45 amp aa rha h lekin output 30 amp de rha h setting 0 pr set h. 12v 200 ah betry. unlimited amp nhi mil rha h. kya amp losses ho rha h.
mera manna h ki mppt k nam se logo ko loota ja rha h aap k pas 80 amp ka controller h lekin aap es pr 60amp tk ka output nhi kr sakte. aapko yh sirf 40 amp output hi melega try it
Hi Sandhu ji, I have installed 4 panel 335 each in 2 parallel x 2 series but I am getting 45 amp Max and voltage showing 78 apx and Max 5.5 unit generating per day. Is it ok or can be better than this
Sir at present mere paas normal single battery inverter h ab mera plan smarten superb 2500 jo ki local market me mujhe 11000 ka mil raha h to me mera jo ek purani tall tubler 150ah ki battery ke sath dusri 150 ah ki solar battery laga sakta hu kya plz
@@nagoriaframera system 12vol ka tha es liye amp yada dekha raha hai abhi 30amp aa rahe hai to buhat asha hai other wise panels barhi to amp or barhe ge
Jada tar video banane wale ye galti kyo karte h aap asha power to kai bar bol diya par ek baar b uska model nambar nhi bolte costumer agar lena chahe ga to konsa lega batao aap ka Controler kona sa model h ye batao
Please read page 11 of the .pdf for your particular model, where you can set the charging ampere from minimum to the full ampere capacity of your ASHAPOWER. The charging ampere can be varied in 3 different ways, 1)initial limited ampere charging, 2)Ampere Limiting based on load shifting voltage, 3)Ampere limiting based on Charging mode. It also comes in MAX-AMP setting which is menu 6 on Surya 40HV version 7and Menu 3 on Surya 60HV version 6.6 in the .pdf file. You can limit the battery charging ampere from 3 amps to the full amp capacity of your Ashapower model.
Sir , 12vot invetor ,12vot single battery, may 24vot soler panl laga sakta hai ki nahi? Or ager laga sakta hai to change controller kan cha le? Plz ans me
Very informative video, i also going to install my own off grid solar system.
Indian brand mein shayad yahi controller 90/95% solar panel se output extract karta hai. Baki k sare to 50/60% se jyada extract nahi kar pate. Aur hamare anadi youtuber dc to dc buck converter function ko mppt function bata dete hain ya to inhe pata nahi hai mppt hota kya hai ya fir ye sponsored video banate hain. In anadiyon ki wajah se maine utl controller liya jiski solar efficiency muskil se 60% hai.(500 watt k panel se 300 watt se jyada power kabhi mili hi nahi) Aapki video dekh kar is cintroller ki solar power extraction efficiency pata chali. Good job sir. Agar ho sake to amberroot mppt controller ki solar efficiency ki vidro banaiye taki log ek good controller k bare mein jaan saken.
Regards,
Thanks 🌹
Ashapower Mppt kisa he
Surya 60 pe 24 volt k liye kitna panel?2kw watt panel laga sakthe ho kya?
Surya 60 hv
On 24v system voc 165 and maximum 1600watt panel lagge ge
Sir model kya he
Nice video sir ji 👍🏻
Aap ameroot ke Rehub ki baat kar rahe the... 😁
Sir your videos are very informative. I have raise the same issue to Ashapower about charging current if we add more panels
Charging current is not issue you can use 2string
Sir panel kitne waat
Sandhu g agar possible ho toh is charge controller ko open kar iska inside view jarur dikhayega
Isme torroid coil kitni lagi hai.....
Sir mare pas neon 80 he lv model he. agr koi 2nd hand lana chatahe to connect kar shakte he
Place/Area
Hooghly-West Bengal
Kyon sale karta hai? Kya rate?
Sir mera Ashapower surya 60 short huva hai.... Tino light on rahte sath me Bip ki aavaj aati hai.... Plz batao ise repair kaise kare..? 🙏
Contact with customer care
I got 335 watt poly crystal solar panels can I use 5 panels for 1600 watt requirements
Ampere limit hai na use on Karo sath hi battery ah option hai na
Best video
Sir maine apna inverter change kr dia hai pehle 12 volt ka tha ab 24 ka laga dia hai or battery ke connection series main kr diye hai
Mere paas 900 watt ke panel hai 100 ×9=900
3 ka set banaya hai total 3 string banai hai to ap bataiye ki panal 24 volt ke hisaab se kam hai ya thik hai
Or ek baat ashapower surya ki settings mai 24 volt system pr battery ah settings kitne pe rakhni hai 150 ah par ya 300 ah pr
And one more question sir usar manual pr no 8 ke settings cal amp ki jo hai usme maine 160 tak rakha hai jitna vo maximum hai to thik hai ???
Thx respectable sir
Sabhi questions ke ans details de dijiye plz ap se yehi umeed hai thx
Panel ki voc bato kitni hai?
8 no. Settings nahi change karni es se aap ki display flash amp ki reading dene lagg jaye gi vo ontni hi rakho jo pehle thi je to calibrate karne ke liye hoti hai.
Agr do battery 150 + 150 ah ki series mai laggi hai to 150ah hi setting karni hai
300 pe nahi
@@sandhuztech4465 thx
Panel ki voc 60 hai teen string ka mila ke 15 amp aata hai
8 no ki settings pehle 133 pr thi vo minimum 110 pr jaati hai or maximum 160 pr to maine 160 rakhi hai
Agar kam krta hu to ampere kam dene lagta hai
To kiya 133 pr rakhu ya kiya kru
Or kiya panel kam hai or lagane ki jaroorat hai ya nahi
@@gurbaniras8601 ek panel ki voc batto g
@@sandhuztech4465 20 voc
@@gurbaniras8601 ek panel 100 watt ka or buy karlo or 5+ 5 ki do string banna ke laggao results jadda ashe aye ge
Ja fir 6 panel series mai chala ke dekho aap ko results ashe mile ge
8 no. Wali settings 130 pe kardo ja agr aap ke pass dc ampere check karne meter hai charging amp. Meter ke or display ke same hone chahiye aagr kam jadda hai to es 8 no. Settings se sett karo
Sir neon 80 main 4 battery per kam se kam kitne solar panel lga sakte hai
Voc 100 to 150 ke bich lagga sakte hai
Very good information, but I connect 2 solar panels of 440 Watts on one battery (along with this Solar Charge Controller). It was working fine from last 3 days but now, the display of MMPT Solar Charge Controller gone. Can you help me in this regard? Any help will be appreciated. Thanks!
Call to coustomer care
@@sandhuztech4465 Okay. Thank you!
Sir mene Nova 50 order kiya hai 24 volt system ke liye..kya ye shi h
As per your requirement you can purchase it
Sir 390 watts ke 4 panel mono perk ke liye kaun sa theek hai
Bhai aap asha power ke grid aur inverter connection kase kare uske video bano
wo wala mppt controller kaun sa hain?
Sandhu sir kya ashapower charge controller ko grid input Dena jaruri hai??? please batayen mein purchase karne ka plan kar raha hu sir
Je work battery voltage pe karta hai but inverter ki main control karne ke lei vo line es ko dena parhta hai agr app only solar se battery charger karna chate hai to es ke bina bhi kaam chal jae ga
@@sandhuztech4465 Sir aur query tha ki ashapower charge controller battery full karne k baad kya solar ke upar Ghar ka load chalata hai??
Hello 👋 sir muje is se badea ambrroot rehub 12vand 24v 40amp smu laga keo k panal se ketne vi amper Ae magar bo 18 amper se jeada nahe Jane data battery ko
Amberrot asha hai per efficiency kam hai
Har bande ki aapni choice hai koi kis chij ko preference deta hai koi kisi or ko so je amberrot bhi best hai efficiency ko chod ke aagr aap ki battery time rehte charge hi na hui to kya feda es ko voc max 90 hai
Ek video es ki smarten ke 2500 va ke sath comparison ki banni hai vo dekh lena
Thanks for comment
sir ye konsa model hai ,aapne bataya hi nahi , neon 60 hai ya surya 60 hai ya neon 80 hai plz replay
80 sir
Trapsun, Ethan compny ka mppt charge controller kessa he
On se je asha hai on pe bhi je function nahi hai or efficiency bhi es se kam hai
Ethan/ trapsun/ msv sab ka circuit aik hi hai yani circuit aik hi company bana kar de rahi hai aur ye sab apne brand tag kar sell kar rahe hai
I think you were talking about amberroot mppt charge controller
Yes your right but vo efficiency mai maar kha rha hai so os ki efficiency nahi barhi ja sakti buhat es ki problem controll k8 ja sakti hai
@@sandhuztech4465 magar battery ko to mar marta h na Asha power
very informative video sandhu ji . I am going to install my off grid solar system and I have purchased the neon 60 asha power charge controller i have two battery system of inverter with 2500 va can you suggest me how much wattage of solar panel I should install and daily on an average I use atleast 13 units .
You can install 1600 watt panel and voc should be below 150v
Please upload a comparison video with amberroot rehub.
Me 1800 watt ka 180 watt × 10 pannel lagaya hnu , aur mera 10 am pe 81 Ampare ,nikal raha he , asapower neon 80 lv. 220 ka 2 battery aur 12 volt inverter me chal raha he , aur abhi problem yee he ki jyada dhuup me display blank ho ja raha he, aaab yaa karu ???? Kuch suggestions dijiye
Neon 80 lv per 1200w panel support hai 1800watt kaise support kar gaye?
Controller ke output me pahle battery connect kro ya inverter koi fark nahi padega.
Pehle battery phir solar fir inverter ki main
Sir
Mere pass 390watt ke 4 panels lge hai jo waaree company ke mono perc hai or maine ispe ethan 60a charge controller lga hai or maine 4 battery ko 24v pr use kr ra hu but meri battery full charge nhi ho rhi hai kya kru mai
Sir ji inverter pe ampere meter lagane se kuch volt ka drop aata h ...jis se inverter ki battery output 14.60 ho jaygi lekin battery terminal ki 13.60 hogi ...or inverter charging me malfunction karega ....shunt wala ampere meter use Krna chahea ...ye coil wale voltage drop krte h ...
Etna fark nahi parhta dear
20 ampere pe itna drop aata h sir ...i have checked it
क्या ये बेटरी फूल चार्ज होने पर चार्जिंग कट नही करता ?
To Bulk charging, Float charging kya hay ?
Cut karya hai per jab charge karta hai agr aap ke amp jada aa rahe hai to battery ko jaldi charge karta hai
Paaji ek baat batao ashapower MPPT controller se without battery sirf normal inverter lagake ghar ka load chala skta hu kya?
No dear
Matlab load battery se hi chalega ye just charge krega. Aur aise solar battery grid system k liye eapro 3725 mppt solar inverter lu?
@@arnabkumarmondal510 epro matt lena
Agr budget hai to hybrid inverter lo
Jo on gird and off gird ch sakke aaj kal cellcronic ka hybrid best manna ja raha hai
Agr off grid hi lena hai to luminous ka le lo
@@sandhuztech4465 thank you sir
Neon 80 give 80amp in real
Please ek detail video banao......
🌱🌱🌱🌱🌱🌱🌱🌱
Bhai ji
Battery ko overcharge ko cover
karne k liye kya kren ??
Apke video ka bhi intezar kar raha hun
ruclips.net/video/br0bHrNdgYI/видео.html
Je video 17 min se dekhni shuru kijiye
Are bhi to usmai kya prob h load chala liya karo day time m . Ghar m koi lod nahi hai kya .
Single battery pr kitne Watt lagate h
Sir is controllar m display watt show hote h kya
No sir
To kya ye controller battery full charge hone per bypass off kar k solar plus battery p load chalta h
Agr battery Full charge nahi to bhi je battery bhi charge kare ga or load bhi chalega
Thanks for this video Sirji .
Sir, Paichana mujhe?
Sir 24 volt baitry ki setting ka video bna do
Nai video dalo bhai kaha gayab ho
Zarur kush busy chal reha bro jaldi hi videos pau ga
@@sandhuztech4465 dhanwaad sandhu sahab
Bhaiji mene surya 60 model lagaya hai or 390 watt ke 2 pannel mein wo to itna 76 volt se 8-9 AMP hi same climate mein charge kar raha hai aap ka mppt to 19 amp kaise kar raha hai???
I can't understand what you say dear
aap bhi amp meeter lga lo aap k bhi aane lagege.
Veer ji apda number chahida c mai asha power nova 50 lea setting krni hai
इसकी कौन सी सैटिंग है जिससे बेट्री भी चार्ज हो और लोड भी साथ साथ चले
ruclips.net/video/PSSJSAHDIbs/видео.html
Kya esse battery full charge hone ke bad direct load solar se chal Sakta hai kya clear kare plz
Yes through battery
@@sandhuztech4465solar fully available hone per battery ki cycle use hogi ya direct solar current se load chalega?
@@Manishkumar-dj6kl battery voltage aap set kar sakte hai man lo aap ne chahte hai battery voltage 13v hone pe je aap ka load solar se chalane lagge ga
Apke pichle video par maine yahi samsya to btaai thi ki ye battery ko jyada amp se charge karta hai,
Tab aap maan nahi rahe they
Mai aap ki baat nahi samjh paya hoga aap kehna kya chahte the
But fir bhi je market mai sab se asha controller hai
Agr aap ke pass amberrot ko chorh kar or koi vakalp hai to please zarur batto in same budget
@@sandhuztech4465
Amber root k charger ko aap parallel mein kitne bhi lga sakte ho,
battery ko amp kam he milenge
@@sandhuztech4465
Amberroot mein kya dikkat hai
Vo bhi 40 amp ka he hai
charging current limit karo 30A tak by seeting the battery ratings under settings.
2. Select option "1" for limited ampere charging up to the set value of 7th menu.
(7.GRD-SOL) ( Grid to Solar shifting volt 14.2V default) When kept in this mode
MPPT delivers only 30 amps of continuous charging current to the battery if the
Ah is set to 150 and delivers the maximum available ampere to load and battery
charging after shifting to solar power.
Right sir i know this setting but problem is here when load shift ed to solar then start limited charging if our load required more then 30amp and our panel have capacity to till 40amp but we select limited charging option and we can use only 30amp
If have any more solutions want to shoot th video on this topic so please tell us
@@sandhuztech4465
Q: If the charging current configured to 30 amp, using 2000 watt panels for 24 volt battery bank, atmax. Are remaining amp willbe wasted?or use ac load
A: 30 amp is the maximum amp that will be used for charging.
If your batter is running with the full charge, Amp will be directly proportional to the load connected.
If load is more , more ampere will be shared. Battery charging will be done only as per the requirement.
By ASHAPOWER on 14 September, 2020
Contact Ashapower and they will guide you for the exact settings needed.
@@Ninja.9777 I already cantact to Ashapower care but their is no solution
Why you spouse max Ampere is 30 amp
My mppt neon 80 give me maximum Ampere till 42 so what you say about this condition
Kya ye lithium battery ko charge kar sakta hai?
No
sir.. surya 60 me penal se 45 amp aa rha h lekin output 30 amp de rha h setting 0 pr set h. 12v 200 ah betry. unlimited amp nhi mil rha h. kya amp losses ho rha h.
Sir mai je push raha hu ke aapne panel se aane wale amp kaise check kiye?
Or panel kon se kiti voc|watt ke hai pura system bataie
@@sandhuztech4465 sir 150w k 12v series me 5 penal connect voc 100. 12v system pr. display me 42 amp lekin output m 30 anlog dc meter se chek kiya
mera manna h ki mppt k nam se logo ko loota ja rha h aap k pas 80 amp ka controller h lekin aap es pr 60amp tk ka output nhi kr sakte. aapko yh sirf 40 amp output hi melega try it
@@sheelendrakumar8523 video banna raha hu aap ke topic pe esa kyon hotta hai
On grid ka ja off grid best hia
Amberrot mppt or asha power mppt which one best?
Buy ashapower.. Service is good
क्या ये बेटरी फूल चार्ज होने पर चार्जिंग कट नही करता ??
Karta hai but ampere ki baat kar raha hu
Sir ji mujhe bataiye solar controller kitne volt aane ke baad great ko disconnect kar ta hai 👍
Jitne pe aap set karo ge
Hi Sandhu ji, I have installed 4 panel 335 each in 2 parallel x 2 series but I am getting 45 amp Max and voltage showing 78 apx and Max 5.5 unit generating per day. Is it ok or can be better than this
Mera 330 ke do panel lagge hai or 3 plus unit banna raha hai aagr weather bukul clear ho
Bhai voc kya hota hai
Sir isme single battery ke sath kitne panels laga sakte h
1000watt ke
@@sandhuztech4465 single battery par 24v ke 325 watt wale 3 panel laga sakte h kya
@@azadkhan0786 lagga to sakte hai but voc 120v se yada nahi honi chahiye
@@sandhuztech4465 pararel lagana padega ya series me
Sir at present mere paas normal single battery inverter h ab mera plan smarten superb 2500 jo ki local market me mujhe 11000 ka mil raha h to me mera jo ek purani tall tubler 150ah ki battery ke sath dusri 150 ah ki solar battery laga sakta hu kya plz
सर जी ये एमपियर मीटर कहा से मिलेगा
SANDHU JI AAPSE CALL PE BAAT KARSAKTE HE KYA
Aap ne DC Analog meter kahan se liyye Sir ?
ज्यादा पेनल से कोई दिक्कत नहीं है क्लाउडी वेदर मे ज्यादा करंट मिलेगा और धूप मे करंट लिमिट से बैट्री ओवर चार्ज नहीं होंगी
Inverter bi amp leta rhata
Sir keh hum off grid invertor ko on grid banasakte hay.
No
सर मेरा nova 50 mppt कंट्रोल 1300 watt के पैनल पर सिर्फ 4 एम्पीयर ही बड़ा कर दे रहा है और आप 4 से 19 एम्पीयर की बात बता रहे हैं
Battery kitni laggi hai 12v ja 24v
@@sandhuztech4465 sir 24volt luminous c10
Abhi 10:30 ko tolt 30 ampere aa rhe h
@@nagoriaframera system 12vol ka tha es liye amp yada dekha raha hai abhi 30amp aa rahe hai to buhat asha hai other wise panels barhi to amp or barhe ge
@@sandhuztech4465 kya wair se bhi ampere me fark padta hai mene DC wair 4mm ka lagaya hai
Jada tar video banane wale ye galti kyo karte h aap asha power to kai bar bol diya par ek baar b uska model nambar nhi bolte costumer agar lena chahe ga to konsa lega batao aap ka Controler kona sa model h ye batao
Jada tar viewers bhi je chahte hai ke hame yada videos na dekhni parh or sidha results pe punch jaye 😃
@@sandhuztech4465 jab aap products ka naam lete ho to uska model nambar bi bola karo taki pata chale konsa model kiske liye acha h
ruclips.net/video/PSSJSAHDIbs/видео.htmlsi=BXbHJ7_vlxjP3VsQ
इस मे ऐलो वायर इनवर्टर के द्वारा कनेक्टर है
Yes
Please read page 11 of the .pdf for your particular model, where you can set the charging ampere from minimum to the full ampere capacity of your ASHAPOWER. The charging ampere can be varied in 3 different ways, 1)initial limited ampere charging, 2)Ampere Limiting based on load shifting voltage, 3)Ampere limiting based on Charging mode. It also comes in MAX-AMP setting which is menu 6 on Surya 40HV version 7and Menu 3 on Surya 60HV version 6.6 in the .pdf file. You can limit the battery charging ampere from 3 amps to the full amp capacity of your Ashapower model.
Sir I already read and do practical but charging AMP to battery didn't control if load is zero
@@sandhuztech4465 please write to the company. I am sure they will give you a solution.
@@sunilcherianpullockaran8817 many time i call to company i don't know they can't understand this problem
24 vot penl me 12 vot battery charging karta hai
Yes
Sir , 12vot invetor ,12vot single battery, may 24vot soler panl laga sakta hai ki nahi? Or ager laga sakta hai to change controller kan cha le? Plz ans me
Kindly reply
Esa koi mppt na lo jiska service achha naho
Bhai kharaab hone per sahee ho jaata hai
सेटिग करनी नही आती क्या।करेनट सेट होता है।लगता है इस का लिटरेचर पढाही ही नही है।