Why do you put your video name in English then we hear the audio.. Tike absa kuli kulaktcha friends osni pungu blah blah blah blah? At least put captions! 🥴
Please sir galt n sikhaye ARD par motor run krti hii ap khud sochiye ki Induction motor ka jab break release hoga to itna tej se move kregi ki floor pr rukegi hi nhi ok is liye drive ke parameters me ARD speed ko entry ki jati hii aur lift ka motor usi speed pr run krti hii so please galat n sikhaye 😂
Bhai aap kah rahe ha tab ek baat mujhe sirf bataye ki jab supply ni hoti tab motor kese chalti ha please may be i dont have sufficient knowledge. Dont consider argue it is eager to know only.
At the outset thanks Mr amit for watching video and comment. I never saw such things but as far as i know lift runs on UPS due to Govt. recomendation. Plese describe clearly whete you saw such type lift and which make capacity etc. Building sanchalan
Dear 8 to 10 floor hi clear dikhai deta h. but lift dikh jaati h tab hum paas ke floor se dobara dekh sakte h. But this is not a right practice every time.
इमरजेंसी स्विच कार टॉप पर होता है वह फिट में होता है इमरजेंसी स्विच लगाने के बाद तुरंत खड़ी हो जाएगी केवल लाइट जाने की स्थिति में ही ए आर डी के द्वारा लिफ्ट कार डोर खोलकर नियर बाई खड़ी होती है
Bhai kch pta ho to thik h but misguide mt kro. ARD kitne der m kaam krti h?? ARD m break release krti h to lift upr kaise jati h??? Ard m lift 10/15 minute chalegi? Ard m lift ka motor work nhi krta??
@@tiwarig5003 thanks tiwari ji, First ARD takes maximum 1 to 2 minut for operate. Second lift will go down if counter weight is down from half. Third ARD does not operate Motor but control. Fourth , in ARD mode LIFT do not run except rescue. And battery back up only 10 to 15 minuts. Dont bother if u wanna to know anything about utility then let me know. Thanks once again, keep commenting
@@BuildingSanchalan ARD take only 40-45 second If you are a Oprator so you can check next time 🤣, 2nd ARD release single phases so weight logic is failed. 3rd if Ard don't working motor so we can directly ARD to brake motor? 4th Please sir dont misguided Lift just Reached at Floor and ARD cut the supply for panel and all. Please keep research on google and RUclips because you're nothing to do practical. If you has a Teqnical team so you know all of the Question's answer.
धन्यवाद महोदय इस ज्ञान को निःशुल्क प्रदान करने के लिए l मैं आपका आभारी हूँ l इस ज्ञान को हम तक पहुँचाने के लिए l
Welcome
Sir OSG Car men laga hota ya Machine Room Men
Car me
Sir ye OSG nhi hai sos hai sir
OSG- Over Speed Governer, U r right too sos for lift.
Osg ka video bejo
Sir lift Mein power cut hone per minimum kitne der tak emergency light Jal sakti hai ?
yeh to ups per depend karta ha parantu aajkal hum LED light use karte han yeh ghanto jal sakti ha
Video bejo
Me ne lift ka projects bana ya he to aap usaka jawado kiya ki aap aapki marji se baat karni hai please send me and please send
Dost me operation se related video jyada banata hu ya jo mujhse puchha jaata ha. Dost kya jawab dena ha samajh ni aaya
Please inform LOP AND control comunication please tell me
Supparb sir 👍🏼
सर हम आपसे बहुत सी जानकारी लेना चाहते हैं संपर्क कीजिए plz
Sir , car fream, counter fream ka droing v bata dijiya.
Bahut sa sir logo sa kha lakin koi nhi bata raha hi, sir please aap bata dijiya na.
Very nice 🙏
Lift chalti kaise h ye question explain karna chaiye aapko
Yes
counter whait car kai brabar krne kai bad jitne pessanger ki lift hai uska 50 % extra whait dalna hota hai naki car ka 50 %
Yes sir ,
You are absolutely right.
Wrong answer jitne bhi passenger ka lift ho usme hmesha 75 % dlta hai wait ok
Jo aap ne batya hai egelis batya kar ke batae intarviv iglies magte hai
please sir ji ek video Lift supervisor interview ki bhi banaiye
sir lift NOC ke bare me btaye please
Why do you put your video name in English then we hear the audio..
Tike absa kuli kulaktcha friends osni pungu blah blah blah blah?
At least put captions! 🥴
Dear, most of all search in english that's why. And i will try caption.
Nice sir 👍
Very good work sir👍👍
So nice of you
सर एटीपी ऑपरेटर से क्वेश्चन पूछे जाने वाले क्या पूछे जाते हैं ऑपरेटर क्या हमें बताएंगे🙏
ruclips.net/video/-qnnzhOcG0A/видео.html watch it
Lift me apprenticeship kar sakte hai kya
Mee plant video banao
Sir ap bbt m job kr rhe ho m b vhan job kr chuka hu
सर जी 20 पैसेंजर लिफ्ट है एक फ्लोर तक जाने में कितनी बिजली खाती है plz
लिफ्ट में मोटर कितने किलो वाट की है वह देख लीजिए या एनर्जी मीटर लगा दीजिए
Very nice mahiti sir, 🙏
Sir apla no.asel tar massage kara
Please sir galt n sikhaye ARD par motor run krti hii ap khud sochiye ki Induction motor ka jab break release hoga to itna tej se move kregi ki floor pr rukegi hi nhi ok is liye drive ke parameters me ARD speed ko entry ki jati hii aur lift ka motor usi speed pr run krti hii so please galat n sikhaye 😂
Bhai aap kah rahe ha tab ek baat mujhe sirf bataye ki jab supply ni hoti tab motor kese chalti ha please may be i dont have sufficient knowledge. Dont consider argue it is eager to know only.
Sir ji hydraulic lift kaise kaam karta hai or lift technician ka kya kaam hota hai es me sir video banaye dijiye 🙏
ruclips.net/video/I1jBrG4yHhg/видео.htmlsi=_OhHsI9KgLyDWwh4 watch it. And many more videos in channel. please visit.
Lift Technician Ka interview me puche question Ka ek video bnaea na Sir plzzzz
Hallo sir lift 6passenjarchi asel
8passenjar basle tar ashi kay system ahe ki extra passenjar basle ki syran vajto
6 passenger lift me 8 passenger bathne per overload ho jaayegi aur trip ho jayegi.
Sos safti के बारे में पूरा जानकारी दो
Sir one doubt hai
Mere yaha per 1 ton ka lift lga hua hai usme Maine 100 ka pu roller lagaya hai jab ki mere ko uska weight nikalna hai
❤❤
बहुत बढ़िया मालूमात है
एक ऐसी मालूमात बताई है जी लिफ्ट के काम करने वाले भी नही जानते ,,
Nice bro
Sir mai ap ki jankari ke liye bata du ki kuch lift me ARD motor ko run karti hai
At the outset thanks Mr amit for watching video and comment.
I never saw such things but as far as i know lift runs on UPS due to Govt. recomendation. Plese describe clearly whete you saw such type lift and which make capacity etc.
Building sanchalan
@@BuildingSanchalan bhai aapka number chahiye bat karni hai
Sir. Pasennger Hoist lift me batao.
Fireman switch galat explain kiya h
Agar sir ARD na kam kare to ham Maro se aap down kar sakte hain na sar
kya puchhna chahte ho samajh ni aaya
kha sai sikh krr aaye ho sir thoda or pdne ki jrurt hai aapko abhi
Thanks for suggestions.
Agar sir ARD na kam kare to ham Maro se aap down kar sakte hain na sar
Good infourmatison.sir
So nice of you
Lift mantenc ka ak part bnaye sir lift mantance kese hota h sir
I think ARD operation you explain same 1 feet can remove
Auto matic rescue divice
Sir🙏 otis lift shew room ke bare men bataiye
hydraulic lift kaise kaam karta hai
Hydraulic lift hydraulic presser se kaam karti ha .
Hello sir app ek chez or dhayan dijiye
Sir phir ye video kyu banayahe
Samjha ni kya batana chahte ho.
Sir Mera licence hai please mera ek kaam karwa dijiye
Bangla anti video Koran pls
Lift men ER and JU means
JU =justirfarht means adjustment run
ER=Error means something wrong in lift system.
Esh post ka pay scale kitna hota ha
15k to 20k
Sir hindi me interview de sakate hai
Bilkul
R4t
Good evening, fantastic video & knowledge fabulous. Thanks
Hii sir ji
Sir can you tell me how many brands of lifts have in India?
Many like , Mitshubisi, Johnson, Thyssen, Otis......etc.
🙏🙏
Lift Technician Ka ek video bnaea na Sar
Thank you sir
Welcome
Very good sir.
So nice of you
ARD
AUTO rescue device
Sir template ke bareme batao please
Very nice sir
Thanks and welcome
Thank you
You're welcome
10:05 pr jo wards bole wo
Clearly samj nhi aa rha
Respected sir, lift m konsi motor use ki jati h
induction motor
@@BuildingSanchalan konsi induction motor
@@s.k.fitness01 squirrel cage induction motor
Sir agar hamari display so nahi kara rahi hai to ham lending door open kar ke kitne floor upar dekha ja sakta hai
Dear 8 to 10 floor hi clear dikhai deta h. but lift dikh jaati h tab hum paas ke floor se dobara dekh sakte h. But this is not a right practice every time.
Jb ARD kaam na kre to bande ko level me nikalna ki 1 -2 fut upar niche
U may out the passengers at 1 feet level out. But ARD should not be fail.
But don't out the pregnant passengers if level out first have to level LIFT.
Good
Mee plant ky है
Tube settler ka fins damage ho Jane par water ko treat kar skte he...mgf acf filter se
कर सकते हैं लेकिन चौक होने के चांसेस ज्यादा है
bro kya mujhe koi bata sakta hai ki ye kaam kaha par Sikhaya jata hai..?
Yeh kaam company me sikhna padta h na ki sikhaya jaata h
@@BuildingSanchalan company name please reply sir
@@imranansari8872 high rise building, koi bhi
❤❤❤
hello
or ard motor ko run krata hai 440 volt out put deta hai ard
Maine to nahi dekha ho sakta h tumne dekha ho
Koi hai Bhai lift operator
aapko Lift operator chahiye ya lift operator ki naukri.
I have vacancy for lift operator if any then mention here i will contact.
@@BuildingSanchalan lift ka Kam sikhna hai sir
Thanks very nice 👍 😀 vedio s
welcome
very nice video shabji
Thanks a lot
Very nice
Sir emergency stop switch band Karne pe lift kaha pe rukegi Kya lift door open Karne ke baad hi rukegi sir
Please reply me
Thanking you sir
इमरजेंसी स्विच कार टॉप पर होता है वह फिट में होता है इमरजेंसी स्विच लगाने के बाद तुरंत खड़ी हो जाएगी केवल लाइट जाने की स्थिति में ही ए आर डी के द्वारा लिफ्ट कार डोर खोलकर नियर बाई खड़ी होती है
@@BuildingSanchalan thanks you sir
Sir limit ko lekar videos upload hai Kya sir
Jaise limits kitni distance pe lagate hai etc.
Kaha par kam karte ho bhai
very nice sir .
Tys sir God bless you
welcome
Thanks sir
Welcome
Nice sir
Thanks and welcome
OSG normal speed se kitani % par active hoga
watch Lift safety video
@@BuildingSanchalan Maine aap ki lift ki palylist wali sbhi video dekhi..
Aap ne bhut ache se bataya hai. Bhut ache keep it up 👍👍👍🙏
Bhai kch pta ho to thik h but misguide mt kro.
ARD kitne der m kaam krti h??
ARD m break release krti h to lift upr kaise jati h???
Ard m lift 10/15 minute chalegi?
Ard m lift ka motor work nhi krta??
@@tiwarig5003 thanks tiwari ji,
First ARD takes maximum 1 to 2 minut for operate.
Second lift will go down if counter weight is down from half.
Third ARD does not operate Motor but control.
Fourth , in ARD mode LIFT do not run except rescue. And battery back up only 10 to 15 minuts.
Dont bother if u wanna to know anything about utility then let me know.
Thanks once again, keep commenting
@@BuildingSanchalan ARD take only 40-45 second
If you are a Oprator so you can check next time 🤣,
2nd ARD release single phases so weight logic is failed.
3rd if Ard don't working motor so we can directly ARD to brake motor?
4th Please sir dont misguided
Lift just Reached at Floor and ARD cut the supply for panel and all.
Please keep research on google and RUclips because you're nothing to do practical.
If you has a Teqnical team so you know all of the Question's answer.
Sir ARD hamesha down 👇 ki traf work krta hai
Mostly, but according to weight
AAP Kam karte ho Kaya Bhai apka number chahiye
Bhai mai out of India hu
@@SaudiKSAmatch1458 WhatsApp number do bhai
@@SaudiKSAmatch1458 Bhai hamko Kam sikhna hai koi India me hai to number do yar
Excellent explain
Very good 👍
Sir may apkavidio dekh ke pass huaa hu. Lift forman me. bahut achhe hai. sir may apko namst kRta hu Sir 🙏🙏🙏🙏🙏
Bahut achhe dost, video share karte rahna. If any problem in future then mujhe batana
👍👌
Bhai hamko bhi Kam sikhna hai