pl162t pump 9700002 bypass regulation problem LELIT Bianca Giulietta (bypass code 4000063)

Поделиться
HTML-код
  • Опубликовано: 15 окт 2024

Комментарии • 20

  • @alainprefontaine1909
    @alainprefontaine1909 10 месяцев назад +1

    Nice video using the cut away of the pump. Great work cheers from YYC

  • @dcippitelli
    @dcippitelli 7 месяцев назад +1

    Questo e stato molto utile, grazie dagli Stati Uniti!

  • @mhossen
    @mhossen 3 года назад +2

    Always useful Mauro! Thanks

  • @andersmllernielsen4932
    @andersmllernielsen4932 10 месяцев назад +1

    Thanks! Helped me out with my Bezzera Mitica Top

  • @user-ey3in5vl5w
    @user-ey3in5vl5w 9 месяцев назад

    Thanks! Do you have a video on removal and cleaning of the rotary pump? As it is a common problem that the OPV get stuck and the adjustment screw wont do anything anymore. Thanks!

    • @lelitinsider2977
      @lelitinsider2977  9 месяцев назад +1

      if you have the bypass video you can remove the bypass (not all the pump)
      like in this video

  • @Jerryxie88
    @Jerryxie88 Год назад

    Hi Mauro, just wondering where can i get the spare part of that adjustment screw which you took it out at 5:54 in the video?

    • @lelitinsider2977
      @lelitinsider2977  Год назад

      you have to ask to the releller in your country or try this
      lamacchinadelcaffe.com/

  • @alexisreyes3346
    @alexisreyes3346 Год назад

    nice video! did you recomend the phillips 66 grease for food machinary? is H1 NSF

  • @stefanb7529
    @stefanb7529 8 месяцев назад

    I noticed pressure increasing on my Lelit Bianca, so I screw the valve out a bit for decreasing pressure. Then it only shows 7.5 bars pump pressure with paddle fully opened and around 10 bars with closed paddle or blind basket. Now a few days later pressure increases again, but only with closed paddle or blind filter basket up to 11.5 bars. Pump pressure stays at 7.5 bars with fully opened paddle. I think there is a regulation problem with the bypass, same problem as shown in the video?

    • @lelitinsider2977
      @lelitinsider2977  8 месяцев назад

      yes, it can be the bypass,

    • @stefanb7529
      @stefanb7529 8 месяцев назад +2

      @@lelitinsider2977 Update: I removed the bypass completely as shown in the video. The plastic part with the o-ring wasn't blocked or tight, only a little bit limescale, I cleaned it and put a bit of silicone grease on the o-ring. Didn't solve the problem at first. Then I also removed the rear plastic part with the spring in it and I noticed immediately that it was very very firm. Took some time to get it out. I give all a good clean an reassembled everything. Now it works. Solved the problem.

    • @lelitinsider2977
      @lelitinsider2977  8 месяцев назад

      perfect! if you need it is possible change only the bypass!
      @@stefanb7529

  • @25ale52
    @25ale52 Год назад

    I have noticed on my bianca v1 when setting the pump pressure whit closed paddle, the pressure increase 1 bar higher when the paddle is open. Same thing when pulling a shot: at first the pump is on 9 bar, but after the pressure in the grouphead has reach his maximum the pressure of the pump goes on 10 bar. Do you know why? And which pressure is the relevant one for the shot? First or second?

    • @lelitinsider2977
      @lelitinsider2977  Год назад

      The importan is the pressure on the grouphead, the other shows only the pump pressure

  • @marcossombrero8189
    @marcossombrero8189 7 месяцев назад

    Thanks mate for this great Video 👍

  • @atuljangir5601
    @atuljangir5601 4 месяца назад

    Hindi main bataye please