Greetings from Panama, I would like to ask about the YB5145B-V1 meter. IT IS AN AMMETER AND WHAT IS ITS MAXIMUM CONTINUOUS CURRENT AMPERAGE AND ITS POWER SUPPLY. ALSO, IF YOU CAN MAKE ANOTHER VIDEO SHOWING ITS CONNECTION DIAGRAM
You have a 15mA zero error. Mosty meters provide a means of zeroing meter with zero current. On this board, if you short the pads on the top left corner of PCB (see 5:05 of your video) and then turn power ON. Then release short and cycle power, it should remove zero error.
there was not instruction on that and I didn't want to predominantly damage it. The top left corner jumper pad (I believe) are for units of settings of the meter. and we have 5 pad. I've purchase 3 of them so far and they all have different pads shortened. I will see experiment with them to see if I can resolve it. Thank you for the comment. I didn't know about this zeroing of meter. Thanks.
@@robojax Compared to the maximum current, it is negligible, but if I'm measuring the charging current from a solar panel, it can be a significant portion of the total current available at times of low output. In a 24h period, this meter consumes a whopping 1.44Ah, which is unacceptable in many solar- and battery-operated applications. I like your videos and tests, I just wanted to point this issue out. 👍🏻
If you are looking for 50A or higher, then see this video ruclips.net/video/Mmxw7T29Z6k/видео.html
Greetings from Panama, I would like to ask about the YB5145B-V1 meter. IT IS AN AMMETER AND WHAT IS ITS MAXIMUM CONTINUOUS CURRENT AMPERAGE AND ITS POWER SUPPLY. ALSO, IF YOU CAN MAKE ANOTHER VIDEO SHOWING ITS CONNECTION DIAGRAM
Greeting, have you watched the video? All your questions have been answered in the video. All specs and wiring and test.
Thanks for good reviews.
My pleasure!
You have a 15mA zero error. Mosty meters provide a means of zeroing meter with zero current.
On this board, if you short the pads on the top left corner of PCB (see 5:05 of your video) and then turn power ON. Then release short and cycle power, it should remove zero error.
there was not instruction on that and I didn't want to predominantly damage it. The top left corner jumper pad (I believe) are for units of settings of the meter. and we have 5 pad. I've purchase 3 of them so far and they all have different pads shortened. I will see experiment with them to see if I can resolve it. Thank you for the comment. I didn't know about this zeroing of meter. Thanks.
Thank you.
👍
😊
sir can you make a video on SIM800L GSM Module
I will try. right now I've got over 200 projects waiting to be done.
Love you sir🥰
love you too.
The video is a little too long, and you should have measured the consumption current of the meter.
Yes it would have been nice but not important. This is based LED and it consumes like about 60mA which is 0.6% 10A. So it is negligible.
@@robojax Compared to the maximum current, it is negligible, but if I'm measuring the charging current from a solar panel, it can be a significant portion of the total current available at times of low output.
In a 24h period, this meter consumes a whopping 1.44Ah, which is unacceptable in many solar- and battery-operated applications.
I like your videos and tests, I just wanted to point this issue out. 👍🏻