MS06H. [Siemens S210 #08] Servo Torque Reduction, Torque Range (F07900 Alarm), Torque Limiting

Поделиться
HTML-код
  • Опубликовано: 11 июл 2024
  • #siemens #s210 #motioncontrol
    Before: [S210 #7] Motion Control Function Block Programming • MS06G. [Siemens S210 #...
    Next: [S210 #09] STO Safe Torque Off and SS1 Safe Stop • MS06I. [Siemens S210 #...
    Siemens Control Playlist: • Siemens Controls
    Motion Control Playlist: • Motion Control
    Chapter:
    00:00 Introduction
    04:00 Torque Data Telegram 750
    10:15 Read Act Torque Value
    11:10 MC_TorqueRange
    12:20 Notice of using Torque Reduction
    15:00 Issue of Velocity with Position Controlled
    17:30 Fault F07900 Alarm (P2175)
    22:00 Torque Reduction Demonstration
    30:00 Control Bits Analysis
    33:00 MC_TorqueLimiting
    38:00 Torque Reduction Demonstration
    44:50 Comparision between "TorqueRange" and "TorqueLimiting"
    I appreciate you could buy me a coffee via the PayPal link below:
    www.paypal.com/donate?hosted_...
    MS06J. [Siemens S210 #10] Servo Drive SLS Safely-Limited Speed
    • MS06J. [Siemens S210 #...
    MS06I. [Siemens S210 #09] STO Safe Torque Off and SS1 Safe Stop
    • MS06I. [Siemens S210 #...
    MS06H. [Siemens S210 #08] Servo Torque Reduction Torque Limiting
    • MS06H. [Siemens S210 #...
    MS06G. [Siemens S210 #7] Motion Control Function Block Programming and Live Test
    • MS06G. [Siemens S210 #...
    MS06F-2. [Siemens S210 #06-2] Positioning TO - CPU Stop Troubleshooting and Online Test
    • MS06F-2. [Siemens S210...
    MS06F-1. [Siemens S210 #06-1] Positioning TO Technology Object in TIA Portal - Configuration
    • MS06F-1. [Siemens S210...
    MS06E. [Siemens S210 #05] Setup Profinet IRT Communication for S210 Servo Drive (Telegram 105)
    • MS06E. [Siemens S210 #...
    MS06D. [Siemens S210 #04] Commission S210 Servo Drive using TIA Portal Startdrive
    • MS06D. [Siemens S210 #...
    MS06C. [Siemens S210 #03] One Button Tuning SINAMICS S210 Servo Drive
    • MS06C. [Siemens S210 #...
    MS06B. [Siemens S210 #02] Using Webpage to Configure SINAMICS S210 Servo Drive
    • MS06B. [Siemens S210 #...
    MS06A. [Siemens S210 #01] SINAMICS S210 Servo Drive Hardware Introduction
    • MS06A. [Siemens S210 #...
  • НаукаНаука

Комментарии • 16

  • @framos9991
    @framos9991 5 месяцев назад +2

    You are the Best teacher I have ever seen .

  • @BallAndBeam
    @BallAndBeam Год назад

    Best RUclipsrs on PLCs. Thank you!

  • @user-ev3tx3zk5d
    @user-ev3tx3zk5d Год назад

    Thank you very much for your explicaton.

  • @bhagyodayasinghjadhav7951
    @bhagyodayasinghjadhav7951 Год назад

    Thank you sir...

  • @mohammedrezk8072
    @mohammedrezk8072 Год назад

    honstly i have learned much from these playlist so Thanks for your Efforts, but i have a question on practical life scenario, i have four v90 drives controlled by S7 1500 cpu and lately i have randomly errors on two of them (HW Limit exceeds) while this is not occured , aslo from where i can know the real cause (is from Drive monitor Error Code or from the Commissioning Tab inside TO or from the PLC CPU diagnostic buffer )

    • @electricalautomation
      @electricalautomation  Год назад

      If you are not using the HW Limit but it is causing trouble, please check P29300, it could be set = 6. If you are using HW Limit, properly check the sensor flicking.

  • @maxjuniet
    @maxjuniet Год назад

    Hello, I hope you can help me.
    I have an engine BG65S from dunkermotoren that i command with a driver PDC1000 and a PLC S7-1500, thanks to your video i learned how to create the telegram 750 and read the torque value but i got a Word value (that is supposed to be a torque value in Nm but not) and i see that you are using a LReal.
    How did you get this value ? Did you convert it ?
    Thank you

    • @electricalautomation
      @electricalautomation  Год назад

      Once you activate Telegram 750, and download the configuration, your TO can read out the torq value, as shown in video 10:21. But different brand would do slightly different for preparing the data for telegram 750, many be doing % of the fully torque (full torque is your motor full torq, e.g 10.5 Nm), or the actual torque Nm value.

    • @maxjuniet
      @maxjuniet Год назад

      @@electricalautomation
      Hello thank you for your first answer. I verified the unit in the settings of my TO and it should be in Nm. After discussing in the siemens forum, it seems that my word value represent a torque purcentage as you said (so 16383 should be 100% of my available torque). I would like to retrieve a Nm value from it. My engine got a rated torque of 0,53 Nm (maximum 1,7) but there is a reductor of I = 100 so finally i got 38,69 Nm (based of the user manual of the engine), the point is that i'm not sure of the accuracy of this purcentage and i would not like to calculate the value in Nm from it, i am afraid that after too much calculation i will not have a torque value i can trust. If possible the best should be to directly have the value in Nm (LReal) from the telegram to have the best accuracy.

  • @vorapobautomation9760
    @vorapobautomation9760 Год назад

    Can use Torque Limiting for unwind and rewind machine ?

    • @electricalautomation
      @electricalautomation  Год назад +1

      Yes, torque reduction is a common function while you are using speed to control tension for winders

    • @vorapobautomation9760
      @vorapobautomation9760 Год назад

      @@electricalautomation Can you show next video how to use it ?