MS02. [Siemens Motion Control] 9 Questions About Siemens Motion Control [2/10]

Поделиться
HTML-код
  • Опубликовано: 3 авг 2024
  • #Siemens #MotionControl #S71500T
    Next:MS03a • MS03a. [Siemens Motion...
    Playlist: • Motion Control
    MS01. Video Series Open Speech
    • MS01. [Siemens Motion ...
    MS02. 9 Common Questions About Siemens Motion Control
    • MS02. [Siemens Motion ...
    MS03a. Single Axis Control - Project Introduction
    • MS03a. [Siemens Motion...
    MS03b. TIA Portal Technology Object (TO) Configuration
    • MS03b. [Siemens Motion...
    MS03c. Reset, Power, Home, and MoveJog Instructions
    • MS03c. [Siemens Motion...
    MS03d. Move Absolute, Relative, Velocity, Stop, and Halt Instructions
    • MS03d. [Siemens Motion...
    MS03e. Download Axis and Program into PLCSIM, OB91 Buffer Overflow Solved
    • COM18. ModbusTCP Clien...
    MS03f. Online Axis Test via Axis Control Panel
    • MS03f. [Siemens Motion...
    MS03g. Rotary and Linear Motion Control Online Test
    • MS03g. [Siemens Motion...
    [SINAMICS S120]
    MS05a. [Siemens S120 #0]SIMAMICS S120 Motion Control Series Open Speech (S7-1500 + S120)
    • MS05a. [Siemens S120 #...
    MS05b. [Siemens S120 #1] SINAMICS S120 Configuration and Commissioning via STARTER
    • MS05b. [Siemens S120 #...
    MS05c. [Siemens S120 #2] SINAMICS S120 Configuration and Commissioning via StartDrive TIA Portal
    • MS05c. [Siemens S120 #...
    MS05d. [Siemens S120 #3] One Button Tuning S120 via STARTER and TIA Portal Startdrive
    • MS05d. [Siemens S120 #...
    MS05e. [Siemens S120 #4a] Setup PROFINET Connection Between S7-1500 PLC and S120 Servo Drive
    • MS05e. [Siemens S120 #...
    MS05f. [Siemens S120 #4b] Setup Motion Technology Object (TO) to Control S120 Servo Drive
    • MS05f. [Siemens S120 #...
    MS05g. [Siemens S120 #5] SINAMICS STO Safety Torque and SS1 Safe Stop vis Safety PLC
    • MS05g. [Siemens S120 #...
    MS05h. [Siemens S120 #6] How to Tune the TO Positioning Closed Loop Gain Kv in TIA Portal
    • MS05h. [Siemens S120 #...
    MS05i. [Siemens S120 #7] Use Motion Control Function Blocks to Control S120 Servo Drive
    • MS05i. [Siemens S120 #...
    MS05j. [Siemens S120 #8] S120 Servo Drive - Changing Velocity On the Fly
    • MS05j. [Siemens S120 #...
    MS05k. [Siemens S120 #9] SINAMICS S120 Torque Limitation, Torque Reduction
    • MS05k. [Siemens S120 #...
    MS05l. [Siemens S120 #10] SINAMICS S120 Velocity GearIn
    • MS05l. [Siemens S120 #...
    [SINAMICS S210]
    MS06J. [Siemens S210 #10] Servo Drive SLS Safely-Limited Speed
    • MS06J. [Siemens S210 #...
    MS06I. [Siemens S210 #09] STO Safe Torque Off and SS1 Safe Stop
    • MS06I. [Siemens S210 #...
    MS06H. [Siemens S210 #08] Servo Torque Reduction Torque Limiting
    • MS06H. [Siemens S210 #...
    MS06G. [Siemens S210 #7] Motion Control Function Block Programming and Live Test
    • MS06G. [Siemens S210 #...
    MS06F-2. [Siemens S210 #06-2] Positioning TO - CPU Stop Troubleshooting and Online Test
    • MS06F-2. [Siemens S210...
    MS06F-1. [Siemens S210 #06-1] Positioning TO Technology Object in TIA Portal - Configuration
    • MS06F-1. [Siemens S210...
    MS06E. [Siemens S210 #05] Setup Profinet IRT Communication for S210 Servo Drive (Telegram 105)
    • MS06E. [Siemens S210 #...
    MS06D. [Siemens S210 #04] Commission S210 Servo Drive using TIA Portal Startdrive
    • MS06D. [Siemens S210 #...
    MS06C. [Siemens S210 #03] One Button Tuning SINAMICS S210 Servo Drive
    • MS06C. [Siemens S210 #...
    MS06B. [Siemens S210 #02] Using Webpage to Configure SINAMICS S210 Servo Drive
    • MS06B. [Siemens S210 #...
    MS06A. [Siemens S210 #01] SINAMICS S210 Servo Drive Hardware Introduction
    • MS06A. [Siemens S210 #...
    [DC Motor]
    MS04a. Setup Positioning Axis via Analog Output, DC Motor, and Encoder
    • MS04a. [DC Motor Posit...
    MS04b. Program DC Motor Positioning Control via S7-1200 and TIA Portal
    • MS04b. [DC Motor Posit...
    [Stepper Motor]
    MS08a. Stepper Driver Wring with PLC 24v Pulse Signal (TB6600 FMD2740C)
    • MS08a. [Stepper Motor]...
    MS08b. 1/2 Control Stepper Motor with a Siemens S7-1200 PLC - Technology Object
    • MS08b. [Stepper Motor]...
    MS08c. 2/2 Control Stepper Motor with a Siemens S7-1200 PLC - Motion Control Programming
    • MS08c. [Stepper Motor]...
    MS09. How to Choose Siemens Telegram For Motion Control
    • MS09. How to Choose Si...
    Reference:
    SIMATIC Technology - Motion Control: Overview and Important Links
    support.industry.siemens.com/...
    Drives Technology Configurator
    mall.industry.siemens.com/spi...
    TIA Selection Tool
    new.siemens.com/global/en/pro...
  • НаукаНаука

Комментарии • 42

  • @siphongxongo8589
    @siphongxongo8589 3 года назад

    My King in Motion Control Salute....!!!!!

  • @gr.imadeddine324
    @gr.imadeddine324 3 года назад +2

    Intresting topic, great video, thanks for sharing !

  • @alialshammary7188
    @alialshammary7188 5 месяцев назад

    thanks for sharing

  • @BallAndBeam
    @BallAndBeam 3 года назад

    Great video. Thanks.

  • @fernandocadena_
    @fernandocadena_ 3 года назад

    Great video!

  • @tarik.b1400
    @tarik.b1400 3 года назад

    wonderfull job thank you

    • @electricalautomation
      @electricalautomation  3 года назад

      Thanks! This is one of the play lists I am proud of. thanks for watching!

  • @ahmedatef5563
    @ahmedatef5563 2 года назад

    Amazing topics

  • @logitronicengineering3240
    @logitronicengineering3240 4 месяца назад

    Thanks!

  • @sotanluy2240
    @sotanluy2240 Год назад

    thanks your so much, video very interesting :>.

  • @industrialautomationkotttu8841
    @industrialautomationkotttu8841 3 года назад

    Keep going

    • @electricalautomation
      @electricalautomation  2 года назад

      Thanks! will do! I am working on some videos about DC Motor positioning control by using S7-1200. They will be launched soon.

  • @abujafor7915
    @abujafor7915 3 года назад

    Thanks

  • @user-rw1pp3nh9e
    @user-rw1pp3nh9e Год назад +1

    Your videos are very informative and thorough. Well Done!!! Question? I am trying to replace an S5 Rack of IP246 Positioning modules,
    I want to use an S7-1500 -1PN with TM2 Posinput modules and analog output modules (Drive Analog Setpoints) to control positioning axes with an SSI encoder feedback. Would that be the most efficient way to go?

    • @electricalautomation
      @electricalautomation  Год назад

      If you migrate your system from S5->STEP7->TIA Portal, then you could use the way you wrote. using TM+SSI encoder and analog out can build up a position closed loop control in S7-1500 and basically your migrated program will have a very minimum change. Another way is that using a servo motor and servo drive and using the 2nd encoder channel from the servo drive (e.g. S120 DRIVE-CLiQ module) for measuring your load side position feedback. Is this application come from Iron and Steel RH air O2 gun application?

    • @user-rw1pp3nh9e
      @user-rw1pp3nh9e Год назад

      @@electricalautomation No We are using it for automatic Size format change in the medical film industry. The IP246 module already has most criteria defined I imagine I can use things like incremental speed, software limits, Forward and Reverse Accel /Decel, etc. I am trying to upgrade incrementally so I am thinking of using FDL(open Comm) to communicate between the S5-135U and S7-1500 to transfer target values and other data.

  • @rahulravi4424
    @rahulravi4424 3 года назад

    I would suggest you to have another Playlist relating SIMIT....it doen't have good resource except the manuals from siemens

  • @tznalcn
    @tznalcn 3 года назад +1

    Isnt tia portal basic enough for s7 1200 plcs with servo drive? For 1 axis robots for example. Great videos btw

    • @electricalautomation
      @electricalautomation  3 года назад +1

      Yes, S7-1214 or higher can support 4 axis (single axis) control. You can use stepper motors or Siemens SINAMICS S210 servo motor as drive.

    • @tznalcn
      @tznalcn 3 года назад

      @@electricalautomation Is it not possible for example with 1211C DC/DC/DC + V90 + Siemens Servo? If not how could we make it happen? Maybe with ET200? Thanks for the answer

    • @electricalautomation
      @electricalautomation  3 года назад +1

      @@tznalcn Yes, it is possible. V90 is a good choice. some area cannot sale or buy SINAMIC V90. If you can buy V90, it is cost effective servo system, it also support profinet with s7-1200.

    • @tznalcn
      @tznalcn 3 года назад +2

      @@electricalautomation Hey thanks for the information. By the way as I said before great videos. If you are looking for a topic for videos, TIA Selection Tool examples for motion control would be a great choice! Have a nice day!

  • @koffikoudjra2362
    @koffikoudjra2362 2 года назад

    Hi
    thank you for sharing this with us,
    may you help me with the "sizer, TIA Selection Tool Online/Offline" links, please ?

    • @electricalautomation
      @electricalautomation  2 года назад

      Please find the link for TIA selection tool new.siemens.com/global/en/products/automation/topic-areas/tia/tia-selection-tool.html

    • @koffikoudjra2362
      @koffikoudjra2362 2 года назад

      Thank you very much!

  • @braincrackz
    @braincrackz 3 года назад

    Hello can you share about alarm trigger and handling in siemens s7 300 cpus. If thats okay for you. Thanks

    • @electricalautomation
      @electricalautomation  3 года назад

      Hello, do you mean using Siemens HMI to show the alarm, and the PLC is S7-300? It would be coming month but not recent. I am working on the motion control and communication series these months. Thanks for watching!

    • @braincrackz
      @braincrackz 3 года назад

      @@electricalautomation not really in the HMI because i am not that yet but the logic i made in DBs can be use in HMI for future use. I only focus on the logic i made a logic for alarm trigger using bools and the problem is i want to make a reset that is in MOVE because i cannot afford to use so TONS of Reset Bit. Using 300 cpu. The idea is splicing the word command into bit in 300 its not possible.anyhow i love watching your videos its more advance

    • @electricalautomation
      @electricalautomation  3 года назад +1

      I roughly see what you talked about. From my programming style, using the bits from a word from individual alarm, then compare this "word=0" for alarm summary.

  • @housamfraunhofer4473
    @housamfraunhofer4473 2 года назад

    ich habe Siemens S120 , power module 27A,600vdc, and Double motor Module 600 vdc , 3Ac 400v 3A:
    is it suitable to connect with motor 400vac , 6,7A ?

  • @kalegamingtv2200
    @kalegamingtv2200 5 месяцев назад

    from this video, i know, i bought wrong device for synchronize position

    • @electricalautomation
      @electricalautomation  5 месяцев назад

      Hopefully the video could be helpful. Would you pls let me know which drive and PLC you bought, and which kind of application you want to do