Комментарии •

  • @serlalonde8420
    @serlalonde8420 2 месяца назад +2

    Nice job young man. Im a 44 yr old fellow whose been doing HVAC for 26 years now and its very promising to see that at least some of the next generation is knowledgeable and not afraid to put in the extra effort to do a quality install. Unfortunately around my parts that is the exception and not the rule. wish i could have one like you on our install crew.

  • @pmichaelhayes
    @pmichaelhayes 2 месяца назад +2

    Great job! Great attention to details and documentation!

  • @chgo007
    @chgo007 Месяц назад +1

    Great install 👍🏽

    • @DCHVAC
      @DCHVAC Месяц назад

      Thanks 👍

  • @HVAC1116
    @HVAC1116 2 месяца назад +3

    Looks good! Would recommend putting the scale on the ground when charging, restricting airflow on the condenser will raise subcooling

  • @kens.3729
    @kens.3729 2 месяца назад +6

    Thanks for Posting again. Nice Install for you and Peter. 👍🙏

    • @DCHVAC
      @DCHVAC 2 месяца назад

      Thanks 👍

  • @petersmart1999
    @petersmart1999 2 месяца назад +4

    I have said for years,that min 7 wire t-stat wire should be code ! Just finished a job ,that ony had 3 wires,so had to fish new ones. Also should not be allowed to cross stud bays! Thx for the video

  • @Ryansroga-wm6pj
    @Ryansroga-wm6pj 2 месяца назад +2

    That house call pro is sweet thanks for sharing nice job happy to see you’re posting again

  • @scottmaz4063
    @scottmaz4063 2 месяца назад +5

    Great video job well done as always.

    • @DCHVAC
      @DCHVAC 2 месяца назад +2

      Thanks again!

  • @dkinfishing
    @dkinfishing 2 месяца назад +2

    That was some clean brazing Daniel 🔥 nice to see some videos coming from ya

  • @Richard-zz2cb
    @Richard-zz2cb 2 месяца назад +1

    Nice job! Love the channel my guy!! Glad to see another person opening the liquid line first, I like to do the liquid line first because that’s how refrigerant flows and I want to avoid damaging things like the txv. I always pressurize a system through the liquid line slowly. Manuals state to open the liquid line first. You’re awesome man!!

    • @DCHVAC
      @DCHVAC 2 месяца назад +2

      It’s a heat pump system so refrigerant flows in either direction.

  • @pat750
    @pat750 2 месяца назад +1

    Been watching your videos and I'm impressed with your level of knowledge and skill at such a young age. Also your commitment to excellence is going to serve you well in your career. How did you get your training?

  • @Howyoudoing98765
    @Howyoudoing98765 2 месяца назад +1

    Great video. I'm installing my first Bosch system saturated. Keep it up. Thanks.

  • @utahockey
    @utahockey 2 месяца назад +1

    Subscribed!!! You are going to have a prosperous career, keep it up man

  • @pat750
    @pat750 2 месяца назад +1

    Love your video. Very thorough and your work looks great! FYI, the Bosch IDS systems (and all heat pumps and ACs) still have compressors. The inverter is a device which changes DC (not you) power to AC. The inverter supplies the power to the compressor (thus an inverter-driven compressor).

  • @richardmeissner147
    @richardmeissner147 2 месяца назад +2

    Great job!! clean, professional work.

  • @Ricardo-m7n
    @Ricardo-m7n 2 месяца назад +1

    Nice install guys 💪
    Keep up the good work 👏
    Miss doing residential
    Now doing commercial and industrial hvacr

  • @utahockey
    @utahockey 2 месяца назад +2

    Love that vacuum technology. Does it save every successful vacuum you make to upload to each job file? Is that a field piece product?

  • @frankgall6
    @frankgall6 2 месяца назад +1

    Good job boys

  • @chuckq54
    @chuckq54 2 месяца назад +1

    Cannot possibly fathom how you can do anything better than this Daniel 🏆🏆. Fantastic work, brazing too. And good job Peter also 👍
    BTW, you’re missing some hair on your upper lip 😂

  • @mattl643
    @mattl643 2 месяца назад +1

    Another good install as always.

  • @daffron101
    @daffron101 2 месяца назад +2

    wifi thermastat is expensive but works great in situations where its hard to re run wire! also no vent after ptrap? it will drain hard and build up algae over time! good video

    • @DCHVAC
      @DCHVAC 2 месяца назад +1

      Great point!

  • @FB-111A
    @FB-111A 2 месяца назад +1

    Very nice install.

    • @DCHVAC
      @DCHVAC 2 месяца назад

      Thanks!

  • @serlalonde8420
    @serlalonde8420 2 месяца назад +1

    Your bossman Mikey Pipes seems an arrogant ass sometimes but if he taught you than i guess hats off to him. Did a hell of a job with you guys

  • @bigcat.mattyahoo
    @bigcat.mattyahoo 2 месяца назад +2

    Hey Daniel, when you screw through the pan, do you have to caulk that I’m assuming with a thermistor wire drilling a hole big cat matt soft an alarm for quiet storm large and in charge big and beautiful 2 pounds of gold, Mikey

    • @DCHVAC
      @DCHVAC 2 месяца назад +2

      The pan is the pan for vertical installation, so it plays no factor whether it’s sealed or not.

    • @bigcat.mattyahoo
      @bigcat.mattyahoo 2 месяца назад

      @@DCHVAC oh, OK dan sorry I didn’t realize that I feel like an idiot now

  • @carrieresammy
    @carrieresammy 2 месяца назад +2

    i ended up swapping from my trublu valve core removal tools back to appion. they just offer better access to rebuilding them.

    • @DCHVAC
      @DCHVAC 2 месяца назад

      Yea I think I’m gonna try the new NAVAC. I don’t like the appion because they leak

  • @scottvolage1752
    @scottvolage1752 2 месяца назад +1

    Good Job Daniel, Keep up the good work. Smash that Like button for Daniel and Peter. Smash it!!! Hay Scott M.

  • @goaski474
    @goaski474 2 месяца назад +3

    Ever have solder spit? SAFETY GLASSES ALWAYS!!!

    • @DCHVAC
      @DCHVAC 2 месяца назад

      @@goaski474 safety squints

  • @GoogleMe-en9sg
    @GoogleMe-en9sg 2 месяца назад +3

    What about just changing the A coil since that was leaking?

    • @PipeDoctor
      @PipeDoctor 2 месяца назад +1

      compressor was sounding like shit lately, not worth the risk - plus we are 1/2 way towards a heat pump house for MASSIVE electrification rebates

  • @mrlegendary9298
    @mrlegendary9298 2 месяца назад +1

    Just curious, why are you brazing and using 15 here when you have been using Stabrite8 on the MP vids ?

    • @DCHVAC
      @DCHVAC 2 месяца назад

      We use braze rod now. Have been for over a year. Check any of mikes recent videos.

    • @mrlegendary9298
      @mrlegendary9298 2 месяца назад

      @@DCHVAC , Did you have issues with SB8 or why the change ?

    • @DCHVAC
      @DCHVAC 2 месяца назад

      @@mrlegendary9298 yes

    • @Bryan-Hensley
      @Bryan-Hensley 2 месяца назад

      ​@@DCHVACI think Mikey blocked my comments because I was trying to tell him about that stuff a long time ago.

  • @elone1748
    @elone1748 2 месяца назад +1

    Housecall Pro is great!

  • @utahockey
    @utahockey 2 месяца назад +5

    Dan & Peter will be starting their own business one day!

  • @mattt8668
    @mattt8668 2 месяца назад +1

    Good job

    • @DCHVAC
      @DCHVAC 2 месяца назад

      Thanks

  • @tatran7169
    @tatran7169 2 месяца назад

    Do housecallpro require for contractors license my friend?

    • @DCHVAC
      @DCHVAC 2 месяца назад

      @@tatran7169 No

  • @PipeDoctor
    @PipeDoctor 2 месяца назад +1

    182 thumbs up

  • @christucker7425
    @christucker7425 2 месяца назад

    What's that nitrogen regulator? I'm in need of a quality regulator. I bought off amazon that was 60$ and it, and it's following replacement failed.

    • @DCHVAC
      @DCHVAC 2 месяца назад

      Victor edge series 2.0 is the best

    • @christucker7425
      @christucker7425 2 месяца назад

      @@DCHVAC Upon your recommendation I bought it (I'm poor and it was really expensive so it was a big leap) was delivered yesterday. BRO. I did a system today and where the hell was this thing all my life lol. It's amazing!

  • @juicepark8785
    @juicepark8785 2 месяца назад +1

    Try to weld with b tank homie

  • @Dicofol1
    @Dicofol1 2 месяца назад +1

    You could make a fake customer using the shop address to show more features in housecall Pro...

  • @user-ln7of9gs4s
    @user-ln7of9gs4s 2 месяца назад +1

    I’d rather have a mini split style condensing unit with this type of air handler set up.

  • @greekcs
    @greekcs 2 месяца назад +4

    Does the price of $16550 include installation?

  • @Justin-qz9rs
    @Justin-qz9rs 2 месяца назад +3

    Getting navien vibes from these bosch boards, no way those last? Doesn’t look like it would survive a drop of water

    • @Bryan-Hensley
      @Bryan-Hensley 2 месяца назад +1

      Many brands are going to that, including Goodman, York, carrier, Trane. I work on Goodman more than anything and I hate those boards. They are making me want to quit, however it will end most of the fly by the night companies and diy repairs.

  • @scottmaz4063
    @scottmaz4063 2 месяца назад +3

    #1🎉😂

  • @kens.3729
    @kens.3729 2 месяца назад +7

    If you have a Million Plus Dollar house, 20+ lbs. of Refrigerant is Chump Change. 😬👍

    • @tjlovesrachel
      @tjlovesrachel 2 месяца назад

      Yeahhhhh but that’s deff not what they paid for that… like that’s not a million dollar anything in my world …. But I get it

    • @chrisguillen1495
      @chrisguillen1495 2 месяца назад

      You’d be surprised how tight all these millionaires are.

  • @rossalaimo3156
    @rossalaimo3156 2 месяца назад +2

    You guys get nervous when your with mike. Looks like you know what to do

    • @Bryan-Hensley
      @Bryan-Hensley 2 месяца назад

      I think Daniel has more intelligence. When you have more intelligence than your boss, it can make an uncomfortable environment.

  • @osvaldomcs1213
    @osvaldomcs1213 2 месяца назад +3

    Wow you don't flush the old line set.

    • @PipeDoctor
      @PipeDoctor 2 месяца назад +1

      no, why? UV dye?

    • @osvaldomcs1213
      @osvaldomcs1213 2 месяца назад

      @@PipeDoctor it's always best practice to flush line set. It will get out all contaminants. How is flushing or should a pig through it and never had a problem yet. Once didn't clean the line set and had many issues.

    • @Bryan-Hensley
      @Bryan-Hensley 2 месяца назад

      ​@@osvaldomcs1213how do you flush out the flush? I'm being serious. I can't get all the fluid out afterwards. You'd need an air supply with at least a 7/8 inside diameter hose.

  • @gtpforever
    @gtpforever 2 месяца назад +2

    RUclips unsubscribed me 🤬

  • @liveanddirect789
    @liveanddirect789 2 месяца назад +1

    I’m so glad I don’t do residential

  • @joshr2828
    @joshr2828 2 месяца назад

    Never mention how many times you add charge. According to the law once you know there’s a leak, leak needs to be repaired. If there’s an inspector watching this, you could get reported. Good work on the install!!

    • @DCHVAC
      @DCHVAC 2 месяца назад +3

      @@joshr2828 only in the case of an appliance with a total charge of 50lbs or more is it necessary to fix the leak.

    • @DCHVAC
      @DCHVAC 2 месяца назад +1

      40 CFR Part 82, Subpart F under section 608 of the clean air act

  • @shaboomhabaaz8660
    @shaboomhabaaz8660 2 месяца назад +1

    Technology must not ALWAYS be embraced due to circumstance. It should be, through mutual respect with design and application in-mind. Abhorrent technology exists, ten fold now as compared to a couple decades ago...
    Technology is often added with little regard to end users, using coin phrases like efficiency, or adaptability. In the end, most tech is E waste. End users shovel money hand over fist when it fails. More-so they bend over with the availability times for such tech parts. PSC and shaded-pole motors are still tech, but are environmentally friendlier (Not considering power usage mind you). They are also readily available.
    The IDS is a neat machine. However... How readily available are all its parts?
    We must not forget that all technology shouldn't be inherently cherished or good. Do you want to wait in the heat or cold for esoteric, proprietary tech parts? Do you want to pay for a machine that may be discontinued, or obsolete at the drop of someone else's hat? Things to consider in full prior to pledging allegiance to random tech pushed by someone else

    • @DCHVAC
      @DCHVAC 2 месяца назад

      Parts are available everywhere for these where I live

    • @shaboomhabaaz8660
      @shaboomhabaaz8660 2 месяца назад +1

      @@DCHVAC Near me the CFM was 2 weeks out. SWFL. Customer was upset but I didn't sell them the R2D2 system.

  • @Ivansgarage
    @Ivansgarage 2 месяца назад +1

    Wow looks like pure BS, Bosch, all the crap, electronics, I am lost for words.... why people have turned something so simple in to a nightmare....

    • @DCHVAC
      @DCHVAC 2 месяца назад

      Not a nightmare if you know what you’re looking at.

  • @osvaldomcs1213
    @osvaldomcs1213 2 месяца назад +2

    How lazy not to run a new thermostat wire. Easy up the outside wall.

  • @osvaldomcs1213
    @osvaldomcs1213 2 месяца назад +1

    If you install Bosch it's trash. You're better off with a Goodman lol. If you really want to screw your client. 😂😂😂

    • @PipeDoctor
      @PipeDoctor 2 месяца назад

      you are trash! #LoveBosch

  • @Mustangg16
    @Mustangg16 2 месяца назад

    First video of yours I watched, honestly you are very boring with the video

    • @DCHVAC
      @DCHVAC 2 месяца назад +5

      @@Mustangg16 then don’t watch

  • @timrob0420
    @timrob0420 2 месяца назад +1

    I prefer IDS 1.0 just because has Mitsubishi compressor

    • @DCHVAC
      @DCHVAC 2 месяца назад +1

      @@timrob0420 that would be an exact reason I wouldn’t want one