    This is a demonstration that I created for the Bacharach H10 Pro Refrigerant Leak Detector. First part of the video is a demonstration I created in my garage. Second part of the video is the H10 being used in the field. I forgot to mention price of this in the video, but I paid 560 dollars for mine and it was worth every dime. I have found so many leaks with this thing I would highly recommend.
    leak detector refrigerant
    leak detector hvac
    leak detector ac
    leak detector gas
    leak detector machine
    leak detector freon
    leak detector sensor
    leak detector tool
    refrigerant leak detector
    refrigerant leak detection methods
    refrigerant leak detection
    refrigerant leak detector types
    refrigerant leak detector hvac
    h10 leak detector
    h10 leak detector reviews
    h10 pro leak detector
    h10 pro battery
    h10 pro calibration
    Bacharach h10 leak detector
    Bacharach h10 pro leak detector
    how to use gas detector
    how to use ac leak detector
    how to use refrigerant leak detector
    how to use freon leak detector
    how to use Bacharach H10 Pro Leak Detector
  • ХоббиХобби

Комментарии • 6

  • @itsmisterchris
    @itsmisterchris 2 месяца назад

    Why did it keep beeping after you pulled the wand away?

  • @peterdarlington4117
    @peterdarlington4117 3 месяца назад

    My calibration bottle has been sitting without the sticker cap on it for a year now in my hot ass truck and is still 3/4 full that is a .006 oz per year leak and the H-10 picks it up! None of my field piece leak detectors will trigger on the bottle! I have them all heated diode and infrared nothing even comes close to this thing it’s by far the best leak detector on the market!

  • @suprtl01
    @suprtl01 Год назад

    You can tuck the lid under and snap it so you can use the shoulder strap

  • @tylersaccount
    @tylersaccount 2 года назад +2

    Nice. So you think the auto mode is not sensitive enough in practice? Is there a scenario where you’d use that instead of manual?

    • @mikeyshvac3568
      @mikeyshvac3568  2 года назад +1

      Auto doesn't have to be calibrated like Manual does. I do use auto sometimes like if I see that the evaporator coil for example is very rusty and likely to be leaking there, I will use auto. If it's a newer unit or I suspect the Leak to be small I will use manual. Thanks for the feedback and watching!

  • @chiller-on
    @chiller-on 8 месяцев назад