Top 50 Questions of Electric Locomotive/Conventional Loco/three phase loco/Quiz

Поделиться
HTML-код
  • Опубликовано: 5 ноя 2022
  • Overcharging cycle of BP (5.4kg/Cm2) in WAG9 Loco is for what time ?
    280 Seconds
    180 Seconds
    120 Second
    160 Second
    2. Axle load of WAG9 Loco is ?
    19.8 T
    20.5T
    18.8T
    22.0T
    3. In DC series TM, Starting Torque will be
    Square of Armature current.
    Proportional to Armature current.
    Proportional of Field current
    None of these
    4. Type of Bogie used in WAG-7 Loco is ?
    Cast Steel Bogie
    Fabricated
    Fully suspended
    None of these
    5. Earth fault relay QOP-2 pick up at
    50Volt
    50Amp
    5Volt
    5Amp
    6. Gear ratio of WAP-7 Loco is ?
    21:107
    21:58
    20:72
    15:77
    7. RPS is connected
    in series of TM field winding
    in parallel of TM field winding
    in series of TM armature winding
    In parallel of TM armature winding
    8. QLM setting of WAG-7 Loco is ?
    6Amp
    9Amp
    6.5Amp
    None
    9. In WAG9 Loco maximum braking pressure to brake cylinder by A9?
    3.5Kg/Cm2
    2.5Kg/Cm2
    3.0Kg/Cm2
    4.0Kg/Cm2
    10. How many Pantographs are installed in both units of WAG12 Loco?
    2 Nos.
    4 Nos.
    3 Nos
    None
    11. In DC series TM, when speed is high then Torque will be
    Low
    High
    Can't say
    None
    12. Rating of Transformer used in WAP-9with hotel load is ?
    6531KVA
    5670KVA
    7475KVA
    4170KVA
    13. Rating of Megger used to measure IR of Loco TFP 25KV primary winding is ?
    1KV
    2KV
    2.5KV
    500V
    14. Which type Bogie is used in WAG7 Loco ?
    Co-Co
    Bo-Bo
    High Adhesion
    Cast
    15. In WAG9 Loco BP is over-charged up to
    2.5Kg/Cm2
    4.0 Kg/Cm2
    5.0Kg/Cm2
    5.4Kg/Cm2
    16. Auxiliary winding KV rating of three phase Loco is?
    1000V
    333V
    500V
    750V
    17. Setting of maximum current relay in three phase Loco WAP7 is ?
    5.0Amp
    6.0 Amp
    3.3Amp
    3.5Amp
    18. In WAG7 which relay is used for auto regression of Notches?
    Q51
    Q52
    Q50
    Q30
    19. QLM relay is a ?
    Current Relay
    Voltage Relay
    Pressure Relay
    Impedance Relay
    20. When one wheel of conventional loco slipping due to rains then which relay will act for sanding ?
    Q20
    QD
    Q48
    Q44
    21. Range of frequency of Drive Convertor is in WAG-9 Loco is ?
    80-160 Hz
    65-132 Hz
    65-130 Hz
    80-140 Hz
    22. In WAG9 Loco second letter shows?
    Type of Traction
    Series of Electric Loco
    Gauge of Electric Loco
    Type of Services
    23. DC link voltage of WAG-9 Loco is ?
    1800V DC
    1800V AC
    2800V AC
    2800 V DC
    24. Additional C2 Relay valve of conventional loco used to
    Control BP
    Control MR
    Control FP
    None
    25. IGBT is a ?
    Current controlled device
    Voltage controlled device
    Power controlled device
    None
    26. Diameter of condemned wheel in conventional electric loco is less than?
    1092mm
    1097mm
    1016mm
    1025mm
    27. Tan Delta Test is done to ensure ?
    Resistance
    Insulation Resistance
    Capacitance
    Inductance
    28. QD-2 is provided between TMs
    1&2
    2&3
    3&4
    4&5
    29. In Arno convertor W-Phase winding has how much more turns compared to other phase U and V winding ?
    30%
    20%
    10%
    25%
    30. In Three phase Electric loco when maximum rated voltage to TM is over then high speed running can be achieved by
    Increasing frequency proportionately
    By increasing frequency in square
    By decreasing rotor current in square
    Decreasing rotor current proportionately
    31. Class of Insulation used in Auxiliary machines of conventional loco is
    H- Class
    C-Class
    F-Class
    B-Class
    32. Rated Maximum voltage of TM used in WAP-7 Loco is ?
    2180V
    2000V
    750V
    890V
    33. Value of RHOBA in WAG7 Loco is ?
    200 Ohm
    180 Ohm
    210 Ohm
    175 Ohm
    34. Twin beam Head light works on
    110V DC
    230V AC
    24V AC
    24V DC
    35. Crawbar protection in three phase loco is used to control ?
    Input voltage of PWM Convertor
    Output voltage of VVVF Invertor
    Input voltage of VVVF Invertor
    None
    36. Value of RPGR in Conventional Loco is ?
    100K-ohm
    200K-ohm
    300K-ohm
    50K-ohm
    37. During the regenerative braking when OHE is non- recieptive then generated energy ?
    goes to OHE
    wasted in resistance.
    consumed by TM
    consumed by DC Link
    38. Which type bearings are used in Axle Box of wheel sets?
    Ball Bearings
    Cylindrical Roller Bearing
    Tapered Roller Bearing
    Spherical Roller Bearing
    39. Rating of SI Unit is used in conventional loco ?
    180V
    180KVA
    180Amp
    150V
    40. If Harmonic filter by passed during the running of Loco then ?
    Speed will reduce to 40Kmph
    Speed will reduce to 50Kmph
    Speed will reduced to 30Kmph
    Speed will reduced to 25Kmph
    41. No of teeths in the gear of WAP-9 Loco are ?
    58
    72
    65
    107
    42. Which liquid is used for cooling of IGBT convertor
    Water
    Water +Glycol
    Glycol
    43. Filter winding KVA Rating of WAG9 ?
    250
    400
    600
    300
    44. Road Guage of WAG7 Loco is ?
    1596+3/-1mm
    1096mm
    1096+/-3mm
    1097mm
    45. QCON relay is provided for ?
    Output voltage of SI
    Output voltage of Arno
    46. In three phase Loco Air gap flux maintained constant by which method ?
    None
    47. In 3Phase Loco Series resonant circuit installed with DC link to supress ?
    5th Harmonic
    7th Harmonic
    48. Tap changer run time for all 32 Notches is ?
    10-12 Second
    10-25 Second
    8-12 Second
    11-13 Second
    49. How many total Battaries are used in WAP7 Loco
    26 Nos
    24 Nos
    20 Nos
    13 Nos