complete distribution db box connection 12 way db connection
HTML-код
- Опубликовано: 11 янв 2024
- A distribution board DB is where the electrical supply is distributed from within the building home. The main supply cable comes into the board and is then distributed to the breakers and from there to all the circuits lights fan plugs etc. various sizes of distribution boards are available.
Miniature Circuit Breaker (MCB) automatically switches off electrical circuit during an abnormal condition of the network. means in overload condition as well as faulty condition. nowadays we use an MCB in low voltage electrical network instead of a fuse MCB is much more sensitive to over current than fuse.
Residual Current Breaker (RCB) works on the assumption that the current going to the electronics device must come out from the neutral wire if there is no other way for current flow. In simple words RCB measures the current going inside the connected device and coming out from the device.
Thanks for watching.......
• 12 way MCB Box connection।।AC Circuit... house wiring DB box installation
complete distribution db box connection • complete distribution ...
• How To Make Simple Pencil Welding Mac... Pencil Welding Machine
• Science project car easy How to make ... Science project car easy How to make a car
• How to Make an Extension Box One Sock... simple Extension board ?
• single phase DOL starter Connection. ... single phase DOL starter Connection?
• simple 3 phase contactor connection /... simple 3 phase contactor connection?
• How to calculate eb bill ? How to sav... How to calculate EB bill ?
• Video extension box || 4Socket+4Switch box wiring || Extension box wiring?
• godown wiring | two way switch connec... godown wiring | two way switch connection?
• Tunnel wiring connection diagram || T... Tunnel wiring connection diagram ||?
• Tunnel Wiring Connection with Diagram... Tunnel wiring?
• Video two way switch connection?
• two way switch Connection | 1bulb and... two way switch?
• two way switch connection two way switch connection?
• two way switch Connection | 1bulb and...
school practical
ITI practical
EEE practical
Very nicely explained , Thanks.
Nalla understand anathu anna
Nalla irukku❤
Super anna,,,,
Nice work bro🎉
Suppar anna ❤
Very good work bro
Thanks
God job pro 👌
Superb
Super Bro
Neengal Main rccb breaker input il outgoingum output il incoming koduthullirgal idu correcta
Nega yepadi kuduthalum athoda working function correct ah irukum
Neenga ups vangi matura varaikum ups points eppadi work agum
EB line kuduthu vachirpan MCB kizha
UPS Vaganathum antha MCB kizha kudutha EB line ah yeduthutu ups power kuduthuduvan
Db thalaikeezha vechrukinga & db dressing very worst
Phase Line thickness romba kamiya eruke ! pothuma entha thickness ?
4 sq mm
Bro earth link illa how can slove the problem
Link llana motha wire hum looping panni tap adichiduga oru wire matum db body la mudikiduga
Main phase and neutral wire mm?
4sq mm
Cable lugs vendama?
Your choice
You must install a main breaker for the house before the RCD breaker. In this way, the house is not safe