This is the best graphic explanation on how single phase power work and how is distributed from the mains power post to the house power board thank you .
Excelent sir very clear explation 🥰❤️all world people must and should watch this video.... Mind blowing teaching sir❤️❤️❤️❤️❤️god bless you sir💞💞💞💞leave live Long Long day's sir🧡🧡🧡🧡🧡
i think it's different things between neutral busbar and ground busbar, neutral busbar is a condition when we want to install the electrical component, while the ground busbar for carry leakage current to the earth/ground.
Why is the ceiling fan the one connected to the ground? Or all of the other appliances connected to the same SP MCB are already connected to the ground since the ceiling fan is? If so, are the only ones connected to the ground are the appliances connected to that particular SP MCB? Or the other SP MCBs are also connected as well as all the other appliances with it?
Please can you explain why both the two supply cables from the pole have the same direction for power supply. I thought the direction of the return cable would be backwards
Quick question, If i have 1 × 30A stove circuit breaker 1 × 40A circuit breaker for the inverter inlet 2 × 15A circuit breakers foe the plugs 2 × 5A circuit breaker for the lights, what should be the current rating for my Main circuit Breaker, will i be fine with a double pole 63A MCB?
MCBs are effectively used to prevent any damage to the circuit or the electrical appliance during a sudden electrical surge. An RCCB circuit breaker, on the other hand, is meant primarily for the safety of human beings.
MCB allows only certain level of current to flow and it breaks the circuit when current more than limiting current flows at the time of shortcircuit Or overload. RCCB is also for safety but it works in completely different principle. It always compare the current in live wire and neutral wire and breaks the circuit when they are not same(for normal condition, currents in both wire should be same). Eg. U get electric shocked when current frm live wire flows through u to the ground (earth) without flowing back to neutral wire. Here, RCCB detects unequal current and gets itself into action. PS: answering for other viewers too in case they get same question.
@@rewardk me cleared about Rccb mcb. But electrical shop man told if there is no good earthing it will be difficult getting line power because rccb shutoff. Even a small leakage it will detect.
May l ask someting When you set up newtonlight You don t take newtonlight Come to batbar grow befor and then can you take onemore newtonlightlight from batbargrow come to (n) newtonlight under brecker main
Im looking for advice. If someone can please help me. Im renting a unit in a complex. The landlord gives me utility bills that have ridiculous amounts. And it jus goes up. In 3 months the consumption went from 584 to 1047. I asked for him to send me photos of the readings. I dont even know what im paying for. I hardly used electricity as im not at home 80% of the time. Hes taking chances because im a woman and know i dont know. Pls can someone explain. Its a whatt hour meter its says on bottom single phase 2 wire . It has 5 digits and a red counter just next to it. The meter boxes of all the units are installed further down the complex. Pls can someone tell me how would i make sure that im not being taken advantage of. And what should i look out for. This stuff is greek for me
Thanks for Watching.❤👍
Please Subscribe the Channel.
This is the best graphic explanation on how single phase power work and how is distributed from the mains power post to the house power board thank you .
অনেক ভালো লাগলো এরকম আরো ভিডিও চাই কিছু শিখতে পারলাম
Wah Bhai jaan must video Aapka btane k trika bahut must h 👍
Most perfect guide for single phase.
very nice👍👍👍👍👍 need more please about wiring
Thanks for watching..❤👍👍
Excelent sir very clear explation 🥰❤️all world people must and should watch this video.... Mind blowing teaching sir❤️❤️❤️❤️❤️god bless you sir💞💞💞💞leave live Long Long day's sir🧡🧡🧡🧡🧡
Thank you♥️
ખૂબ ઉપયોગી માહિતી આપો સો ભાઈ
ખૂબ ખૂબ આભાર 🙏🙏🙏
Q : Why dont connect between neutral busbar and ground busbar ? Thank you
i think it's different things between neutral busbar and ground busbar, neutral busbar is a condition when we want to install the electrical component, while the ground busbar for carry leakage current to the earth/ground.
Definitely requires an MEN link between neutral and earth busbars.
هناك طريقتين للتاريض
هو استعمل الاسلوب الذي الارضي غير متصل مع المحايد وهذا صحيح
وحتى لو كانا متصلان يكون ذلك خارج البيت
@@Yazmanyazmanyazman
not understand😅
Very nice .
Thank you Sir
thank you very much ;bien expliqué;merci......./
Very nice Explanation thanks.keep it up 🙏🙏
👍❤👍
Very easy to understand. Thanks
👍❤👍
very easy and best method
Very clear lesson. Very useful. Thank you so much.
Thanks for watching❤👍
V 😂😂 Ff ff zfzfzzzzzxq Ff z fZzf f. Fit asex CD d
Our miss recommend this must watch🎉🎉🎉🎉🎉🎉
I truly love this video❤❤❤
❤👍❤
Nice information
Why is the ceiling fan the one connected to the ground? Or all of the other appliances connected to the same SP MCB are already connected to the ground since the ceiling fan is? If so, are the only ones connected to the ground are the appliances connected to that particular SP MCB? Or the other SP MCBs are also connected as well as all the other appliances with it?
In the mountine like that line 1hot line2 ground
Super bro loved it
Thanks bro
Thanks for sharing
WOW SO CLEAR THANK YOU SO MUCH
Very nice thanks for teaching
❤👍
Thanks, for the demonstration, please if you can , prepare for us also 3 phase wiring for 3 strorey hotel, thanks
Good joob👍🏻
Show de bola 👏👏👏👍👍👍👍
👌👌♥️ supered brother💪
Thanks brother❤❤👍👍
Please can you explain why both the two supply cables from the pole have the same direction for power supply. I thought the direction of the return cable would be backwards
Supiri mybro
Thanks bro❤
what application can draw like that??? thank you SL Engineering Academy for sharing idea.
Quick question, If i have
1 × 30A stove circuit breaker
1 × 40A circuit breaker for the inverter inlet
2 × 15A circuit breakers foe the plugs
2 × 5A circuit breaker for the lights, what should be the current rating for my Main circuit Breaker, will i be fine with a double pole 63A MCB?
63A is quite anough
Nice bro !
Thanks bro.❤
great
NICE 1
Please what's the difference between MCB and RCCB.
Thanks
MCBs are effectively used to prevent any damage to the circuit or the electrical appliance during a sudden electrical surge. An RCCB circuit breaker, on the other hand, is meant primarily for the safety of human beings.
MCB allows only certain level of current to flow and it breaks the circuit when current more than limiting current flows at the time of shortcircuit Or overload. RCCB is also for safety but it works in completely different principle. It always compare the current in live wire and neutral wire and breaks the circuit when they are not same(for normal condition, currents in both wire should be same). Eg. U get electric shocked when current frm live wire flows through u to the ground (earth) without flowing back to neutral wire. Here, RCCB detects unequal current and gets itself into action.
PS: answering for other viewers too in case they get same question.
@@rewardk me cleared about Rccb mcb. But electrical shop man told if there is no good earthing it will be difficult getting line power because rccb shutoff.
Even a small leakage it will detect.
❤❤❤
Thank you so much 🤟
Nice viveo
Please tell me which software you used to do this ?
Kinemaster
great illustrations
❤👍❤
same for stove? Just thicker wires?
Superb
Thank you.👍
May l ask someting
When you set up newtonlight
You don t take newtonlight
Come to batbar grow befor
and then can you take
onemore newtonlightlight
from batbargrow
come to (n) newtonlight under
brecker main
Sir Where did the green wire connected is it connected to grounding Rod? And where is Neutral connected too?
Yes. Green wire should be connected to grounding rod. Neutral connection also come from electric pole as well as live connection.
Super ❤ 2024
Good thx
Some videos show how to connect the main wire at the top. But here you show how to connect the bottom. Is there a difference? Explain a little
Which software did you use tp draw this???
Thanks you
state of art
Shouldn't the ground and neutral bars be bonded together?
Akash babu is the best💯
Good
جيد شكرا
The MEN rule says that at the main switchboard the earth shall be connected to neutral
1 sp mcb support how many socket/lamp??
1 each if possible
Supper
Nice
❤where's your earth goes?😊
To ground through the earth electrode.
Thanks for watching ❤👍
Kitna kitna apere ka mcb use kiya batao bhai
in which software u make this
Greta simulation
Thank you..❤👍
where is the ground for light? in Romania the standard is al consumtion must have ground . exxept switch
Please, software you used to create this ?
Im looking for advice. If someone can please help me. Im renting a unit in a complex. The landlord gives me utility bills that have ridiculous amounts. And it jus goes up. In 3 months the consumption went from 584 to 1047. I asked for him to send me photos of the readings. I dont even know what im paying for.
I hardly used electricity as im not at home 80% of the time.
Hes taking chances because im a woman and know i dont know.
Pls can someone explain. Its a whatt hour meter its says on bottom single phase 2 wire . It has 5 digits and a red counter just next to it.
The meter boxes of all the units are installed further down the complex.
Pls can someone tell me how would i make sure that im not being taken advantage of. And what should i look out for. This stuff is greek for me
Bagus
How to making this video please tell me??
how to adjust the speed variator brand vieche 2.2kw
c'est bien
In what software can I draw a colored electrical diagram with components that I can add to the diagram
Have you get the software brother
@@sahalshire9307 לא הבנתי. מה השם של התוכנה?
If you can, please send/post/ ppt notes.since it helps to read as a manual
MCB rating used?
very depressing music but great video.
What safety fuse they used?
We need reasons why bulb is connected in parallel
what is the software ur using to do this video?
Have you get the software name
It remain how to connect it to the distribution board
This is misleading and downright WRONG standards enter a MCB at the top and exit at the bottom
Can you please elaborate?
Nothing wrong. I did usually
Anything is possible as long as there is no earth wire and no electrical voltage 😢
mcb rcbc can you show us.
No no why is yr connection starting from the bottom and not from the top with bussbar . 2nd comment is real very misleading very very dangerous.
Exactly what I was thinking, scared zero knowledge people will refer this 100% without knowing function of busbar
Why fan needs earth wire?
Name of the simulator
Je suis intéressée par ça
In all videos I could see amps are not clear than how to select MCB and do wiring .
Right question
Why fan link earth?
ড্রয়িং গুলা কি সফটওয়্যার দিয়া করব
Where is cut out and neutral link?
Lights aren't on an rcd though so sure the neutral is on the main neutral bar and the sockets are on a different neutral??
fused?
আমি কাজটা শিখতে চাই
ap ne change over nahi lagaya
Where is the fuse before electric meter.
It's job is to measure any current passing through it and charge money according to it. Why does it need fuse 😃
15
Fan me netrul nai he
yanlış bağlantının üstden olması lazımdı
SOFTWARE NAME PLEASE
বিদ্যুৎ আউট হবে নিচ দিয়ে
আপনি দেছেন উপর দিয়ে
fan no need erth
For safety we can.
Maggie
রিপ্লাই দিবেন ফোন নাম্বার দিবেন
Wrong