  • @stevehendrickson3425
    @stevehendrickson3425 Год назад

    Please get a mic. I can't hear you

  • @WogChilli
    @WogChilli 4 года назад +1

    Resistance = (rho x length)/sectional area.
    Copper rho = 1.7x10^-8 ohm meter.

  • @artemike
    @artemike 2 года назад +1

    Can you terminate alligator/crocodile clips on them?

    • @Endless_Skyway_Adventures
      @Endless_Skyway_Adventures  2 года назад

      Only for short term applications when you are watching them in my opinion. Ring terminals or bussbars of adequate size are the only things I would recommend.

  • @Endless_Skyway_Adventures
    @Endless_Skyway_Adventures  Год назад

    Thank you, not sure why you can’t hear it, I can hear it just fine. But I appreciate your input and I will look into it.

  • @grosjarvis8061
    @grosjarvis8061 Год назад

    The 2000w inverter example is questionable as the stated load doesn't include inverter losses (efficiency)or voltage drop from source. Example given will probably interrupt 175amp fuse if inverter is operated at or near full load for more than a few minutes

    • @Endless_Skyway_Adventures
      @Endless_Skyway_Adventures  Год назад

      Four years, 25,000 miles, same fuse, you assume that I run it at 2000 watts, I don’t. 1500 regularly though.

  • @bayview63
    @bayview63 5 лет назад +1

    I purchased I 2000 watt reliable inverter. Why would they give you 6 gauge wires for the connection to the battery

    • @Endless_Skyway_Adventures
      @Endless_Skyway_Adventures  5 лет назад

      I cant answer for someone else, but my guess is cost. please be careful to check not only wire size but temperature rating and fuse the wire under the amp rating for the wire regardless of your inverter rating. The fuse belongs as close to the battery as possible. If you cant determine the rating, replace the cables. Good cables cost about 90 bucks. It isn't worth dying for 90 bucks. I cant stress enough that the fuse must be the weakest link in the circuit. If your inverter san deliver 200 amps, and you fuse is rated at 190 amps, and your cables are rated for 100 amps, guess which one melts? The cable.

    • @bayview63
      @bayview63 5 лет назад

      Your RV Freedom thanks for your help. I’m at the ‘what the hell did I get myself into’ stage of my solar install. So much conflicting info for the diy guys. Inverter manuals are useless.

    • @Endless_Skyway_Adventures
      @Endless_Skyway_Adventures  5 лет назад +1

      @@bayview63 it's alot to take in. Will Prowse has a lot of good video info and he is knowledgeable.

    • @bayview63
      @bayview63 5 лет назад +2

      Your RV Freedom your right. It is a lot to take in but thanks to guys like you, I can eliminate stupid and expensive mistakes before they happen. I really want to do this right and I am confident I can do that now. Thx for your help.

    • @grosjarvis8061
      @grosjarvis8061 Год назад

      6awg for a 2000w inverter is grossly undersized (assuming 12vdc) should be 2/0 at a minimum depending on cable length

  • @Ojeramup12
    @Ojeramup12 6 лет назад

    Thanks for the video. I will check into the wires that I want to purchase for a 1000 watt inverter.

    • @Endless_Skyway_Adventures
      @Endless_Skyway_Adventures  6 лет назад

      www.ebay.com/itm/2-AWG-Gauge-Copper-Battery-Cable-Power-Wire-Car-Marine-Inverter-RV-Solar/132076737409?hash=item1ec0631381:m:mFuaAsElijaA3N3ljd1MtGw&var=431429431921

  • @jonbinnie
    @jonbinnie 4 года назад +1

    Fantastic thank you! My inverter is 2000W, and it say it can briefly peak to 4000W for a few seconds under load. Am I ok using 1/0 cabling? Else I should go up to support around 333 amps! Also my batteries are all far apart, and I can't move them, so my cables may need to be up to 2 to 3 metres long. So thicker may be safer. Let me know your thoughts thank you!

    • @Endless_Skyway_Adventures
      @Endless_Skyway_Adventures  4 года назад +1

      Jon Binnie length is a factor, longer requires heavier gauge. Short term peaks are usually ok but if they are too frequent they can still heat the wire. Cable quality matters, I would opt for cable that has ratings for both amps and temperature. In your case you might want to go up a gauge. Remember to fuse under the wire gauge.

    • @jonbinnie
      @jonbinnie 4 года назад

      @@Endless_Skyway_Adventures Thank you! Do you have any suggestions on tempertures?

    • @jonbinnie
      @jonbinnie 4 года назад

      Oh and I love that you are a musician too! Two hobbies in common!

    • @Endless_Skyway_Adventures
      @Endless_Skyway_Adventures  4 года назад +1

      Jon Binnie gauge wire and cable on eBay +105Celcius 2/0 is rated for 330 amps