Amana Communicating system

Поделиться
HTML-код
  • Опубликовано: 18 окт 2024
  • How to wire an Amana communicating low voltage system. Step by Step very easy,
    Thanks for watching!
    David
    David@DavidJonesAC.com
    Follow me on Facebook: / david-jones-ac-1010702...

Комментарии • 51

  • @alhoodhoud6909
    @alhoodhoud6909 4 года назад +1

    Thanks David you’re awesome. I’m from Middle East and I’m working here in Texas . I learned a lot from you. Thanks brother so much.

  • @mcallentxramirez3628
    @mcallentxramirez3628 4 года назад

    im an apprentice ...and going to install one after xmas 2019 ..after watching this video i feel more confident ..thanks for the video

  • @larryturner9833
    @larryturner9833 5 лет назад +2

    You made my job a lot easier today....thanks

  • @danielzamora3625
    @danielzamora3625 11 лет назад

    Hello David great vid name is Daniel I'm a Hvac contractor in Southwest Texas Area we are Amana dealers show your vids to my tech all the time keep up the awesome JOB.

  • @nikeij13
    @nikeij13 3 года назад

    Thank You David! this should help. I've been stuck with this 18 seer system for the past 2 days. Going to tackle it again on thursday

  • @jonesacnaples
    @jonesacnaples  11 лет назад

    Those extra wires have come in handy many times. Thanks Rob

  • @AIRCONDITIONINGSCHOOLING
    @AIRCONDITIONINGSCHOOLING Год назад

    Wow David !!!! I appreciate you very much dude!! I am learning about this communication

  • @jonesacnaples
    @jonesacnaples  11 лет назад +1

    Thank you Daniel for watching I really hoe all of these videos help, I just want to help our industry grow with good folks that love the trade as much as I do. I am here to help. Have a great day my friend.

  • @jonesacnaples
    @jonesacnaples  11 лет назад

    Thank you for the comment, I watch your videos you do a great job, keep up the good work. Stay in touch my friend.

  • @noj3167
    @noj3167 2 года назад

    Very helpful video sir! Thank you for sharing

  • @jeffreybricks2687
    @jeffreybricks2687 Год назад

    Thankyou for this video dude, I am starting to understand these a lot more. Question if anyone on here is please willing to help. Why do you have your normal o, g, y1, y2 w1, w2 terminals when all you need is the Datta 1,2, and 24vac R and c ? Are the normal y1, y2, g, w1, w2 just optionable for non communication normal hvac system?

  • @BublysTube
    @BublysTube 4 года назад

    I just ordered the ComfortNet CTK04AE thermostat after using a nest for years, I felt it wasn't as efficient. I have a Goodman AVPTC60D14AD and a Goodman DSXC160601. Will I need to use the transformer when installing the thermostat? I see in the manual where it says
    ADDITIONAL TRANSFORMER
    IS NOT REQUIRED FOR
    INVERTER/VARIABLE SPEED
    OUTDOOR COMMUNICATING
    UNITS.
    ADDITIONAL TRANSFORMER
    IS REQUIRED FOR 2-STAGE
    OUTDOOR COMMUNICATING
    UNITS.
    Any help is appreciated and your video is very imformative. Thank you.

  • @richard5981
    @richard5981 2 года назад +1

    Let me rephrase my question I happen to have the same brand AC with the same thermostat and I have the thermostat has lost communication with the network what is the most probable cause and how much am I looking to pay for repairs

  • @sukhdevbraich4335
    @sukhdevbraich4335 2 года назад

    Really good video

  • @jonesacnaples
    @jonesacnaples  11 лет назад

    I will do it today. Thanks for asking.

  • @krishuntzeroable
    @krishuntzeroable Год назад

    You’re great thanks!

  • @jonesacnaples
    @jonesacnaples  11 лет назад

    You are welcome, hope it helps take the mystery out of wiring in the controls. Take care.

  • @scottminton1999
    @scottminton1999 3 года назад

    I have the variable speed Amana 3 ton unit. When they installed, they used my existing thermostat, which is designed for one or two stage units but not for variable speed. The Amana website says that it's built in "smart" ComfortBridge will allow it to operate efficiently even without the ComfortNet Communicating thermostat. But I'm curious if the communicating thermostat will be more efficient and/or allow more variablity in speed control? Is this thermostat actually better than a standard smart (1 or 2 stage) thermostat? I hate to spend this much money if there's no difference in real life. Thanks for the educational video!

    • @nightone9720
      @nightone9720 2 года назад

      Hey, if you have a communicating air handler with a communicating condensing unit you should absolutely make use of a communicating thermostat. It will absolutely be more efficient. That's the whole purpose of a communicating system. To achieve a higher level of comfort by utilizing a higher level of equipment control.

  • @2purplemartin1
    @2purplemartin1 10 месяцев назад

    What did you do? Did you go from conventional to communicating?

  • @Atsa-x7i
    @Atsa-x7i 7 месяцев назад

    Great thanks!

  • @dannyp3652
    @dannyp3652 3 года назад

    Is this a heat pump system or straight cool?

  • @robertcherry4971
    @robertcherry4971 Год назад

    Dave how about changing a communicating system to a non- communicating system?

  • @EddieLeverich
    @EddieLeverich 11 лет назад

    Nice job!

  • @RobHVAC
    @RobHVAC 11 лет назад

    Nice video Dave.

  • @joelmdn
    @joelmdn 7 лет назад

    Nice Video, How would you wire with a single stage condenser? i have the comfortnet with a modulating furnace. Thanks

  • @boneyfreak9197
    @boneyfreak9197 5 лет назад

    i like the ComfortNet system. Especially when the existing tstat cable is lacking enough conductors.

  • @mcnum92
    @mcnum92 8 месяцев назад

    Can you install a smart thermostat with this system????

  • @flashlitestriker4028
    @flashlitestriker4028 3 года назад

    What about the Amana HVAC units that is an individual-per-room units (like in hotels, under the windows, & the thermostat wire in it? I found out where the "black" end goes to, but not the "white" end.

  • @ulricoizaguirre9523
    @ulricoizaguirre9523 6 лет назад

    Hi - we moved into this house and it already had this thermostat. I have everything (security code, manuals etc) EXCEPT the MAC address and the CRC address for the unit. It is not on the back of the wall plate or the face plate either. How do i find these two vital pieces of information?

  • @jonesacnaples
    @jonesacnaples  11 лет назад

    Thank you I hope it helps.

  • @seanmathews1826
    @seanmathews1826 3 года назад

    Does it have as many problems and issues as the Carrier Infinity and Bryant Evolution?

  • @jerryees
    @jerryees 10 дней назад

    Is this the same wiring method for an amana 2 stage heating and cooling system?

    • @jerryees
      @jerryees 10 дней назад

      And what exactly does the step-down transformer do?

  • @LaCosaRica-m4z
    @LaCosaRica-m4z 11 лет назад

    Good vid. David.!!!!!.thanks.!

  • @rajmohanpm8189
    @rajmohanpm8189 4 года назад +1

    Hello David, is there is any way i can use a new nest thermostat insted of this thermostat?

    • @rajmohanpm8189
      @rajmohanpm8189 4 года назад

      I did changed and using a nest thermostat now.

  • @jonesacnaples
    @jonesacnaples  11 лет назад

    Hope it helps, I tried to explain how easy it is. I am here to help. Thanks for watching my friend.

  • @Comfortclimateservice
    @Comfortclimateservice 11 лет назад

    What a good video!!

  • @danielzamora3625
    @danielzamora3625 11 лет назад

    Want to see if you would make a vid on programming dip switches on high efficiency air handler for Amana . Thanks

  • @michaelgarcia4697
    @michaelgarcia4697 6 лет назад

    Do the goodman communicating systems require dip switch adjustments or does the thermostat do it automatically

    • @omarispence408
      @omarispence408 5 лет назад

      No. Dip switch is for non communicating thermstat

  • @Eddie7Padilla
    @Eddie7Padilla 3 года назад

    How would wire a nest thermostat with that wiring configuration?

  • @jonesacnaples
    @jonesacnaples  11 лет назад

    Thanks, I hope it is helpful.

  • @randybearden4809
    @randybearden4809 9 лет назад

    how would you wire a electrostatic filter to this 4 wire system. my old system it was wired to fan at air handler

  • @UltraHydrophobiccoat
    @UltraHydrophobiccoat 2 года назад

    So, no.1 and 2 are DC ?

  • @acechoice45
    @acechoice45 11 лет назад

    Thank You !!

  • @_Bnieto_
    @_Bnieto_ 6 лет назад +2

    I need help . Just installed an Amana inverter series 3 ton heat pump and want to know how to do the t-stat start up

  • @MF-tm4qu
    @MF-tm4qu Год назад

    Don't forget to ground your transformer with your low voltage common.

  • @clawtoris
    @clawtoris 3 года назад

    but, WHAT ARE 1 AND 2 MEANS?

  • @mrkattm
    @mrkattm 5 лет назад

    Do you know what you are doing? Just give the signal names not the wire colors.