HVAC - Direct Fired Make Up Air Unit

Поделиться
HTML-код
  • Опубликовано: 8 янв 2025

Комментарии •

  • @buildingmanager-marymother499
    @buildingmanager-marymother499 2 года назад

    Thank you for actually showing each component and explaining in detail. I've seen videos similar to this with no in-depth explanation.

  • @RagingOatmeal
    @RagingOatmeal 5 лет назад +1

    Ehh. I spend a full day changing filters on those exact units. Them things are crazy cool. Can’t wait to learn more about them

  • @dougshakell8003
    @dougshakell8003 4 года назад +1

    Code in Canada states filters are to be metal frame. If the cardboard gets wet or plugged they can be sucked into burner and set fire.

  • @johntaylor3043
    @johntaylor3043 7 месяцев назад

    To the point and informative, no fluff. Right on brother.

  • @anilksingh650
    @anilksingh650 3 года назад

    Thank you for making best info video then rest, I have similar one in my facility and today, it got flame failure error and I resetted twice, so I have to open Burner door and clean flame rod after that fire it again and it's worked after since, can you please make a video how to change damper actuator, please and thankyou, keep up the great work bro.

  • @herbertbaum6899
    @herbertbaum6899 Год назад

    Thank you for the video! Question: when and if the flame stops, is it whenbit reaches the set temp. Inside?

  • @logancalgaryriverbug2815
    @logancalgaryriverbug2815 5 лет назад +2

    Hello Just a brief suggestion it is possible you air pressure differential switches are no set up correctlly unless you had the low jumped out.
    The reason I say this is normally the flame should drop out on low differential if the door is that wide open.
    Good video

    • @HVACKnowItAll
      @HVACKnowItAll  5 лет назад

      Thank you, the door was actually only open a few inches at the top just to stick the camera in. But yeah you are 100% correct.

  • @JuanTodoli
    @JuanTodoli 5 лет назад +2

    Cristal clear explanation Gary. Thanks for posting.

  • @marcusmitchell95695
    @marcusmitchell95695 5 лет назад +2

    Dope video brotha thank you 🙏

  • @ultimatecarguy
    @ultimatecarguy 5 лет назад +1

    great video I had a very basic understanding about how these units work. This was straight to the point and very informative.

  • @yetanotheaverageguy
    @yetanotheaverageguy 5 лет назад +1

    How many BTUs does that burner make and what's the combined CFM of the exhaust fans? Looks like a clean burning flame for so much turbulence.

    • @HVACKnowItAll
      @HVACKnowItAll  5 лет назад

      Sorry, I don't actually have the cfm info, we didn't design or install the equipment. I can't recall the btu rating on that lol, sorry not much help am I.

  • @fredmeebley
    @fredmeebley 5 лет назад +1

    Good video, thanks for sharing.

  • @khaleel588
    @khaleel588 5 лет назад

    This roof look so much similar to my previous work place. It this site in Mississauga?

  • @vacuumboy6.0
    @vacuumboy6.0 2 года назад +1

    Very simple and robust design. Alot of this equipment is very simple if you are mechanicaly and electrically inclined 👍😀

    • @HVACKnowItAll
      @HVACKnowItAll  2 года назад

      Yes for sure, thanks for the comment

  • @azhvacr2332
    @azhvacr2332 5 лет назад

    Great video!👍🏼🤘🏼✌🏼

  • @texture6
    @texture6 5 лет назад +1

    At 00:38 it’s not an Economizers and at 01:15 the vertical filter position provide better static pressure since it’s in a vertical position and is more rigid.

    • @HVACKnowItAll
      @HVACKnowItAll  5 лет назад +2

      Who said it was an economizer?? The filters definitely have better structure in vertical position, what do you mean by "better" static pressure? If you mean lower, I haven't seen any evidence to support that even with a magnehelic attached.

    • @ronpowdrell6608
      @ronpowdrell6608 5 лет назад +1

      Texture6. On a make up air unit we don’t worry about static pressure cause there is very little duct work attached. Economizers are attached to a package unit to provide free cooling. It’s controlled by temperature/empathy control.

    • @texture6
      @texture6 5 лет назад

      Ron...Thank you I appreciate

  • @keepthinking2666
    @keepthinking2666 2 года назад

    Old school dfnp-20 nice

  • @scottvanruin6481
    @scottvanruin6481 5 лет назад +3

    Those burner eye windows are useless in those places, yes you can see flame sometimes but you can't see the full length of the burner, especially for setting low fire. Captiveaire does this, 👍, Engair junk does not amongst others.

    • @jonminnella4157
      @jonminnella4157 4 года назад

      I know such a piss off thy should make a better system

  • @michaelmead5880
    @michaelmead5880 5 лет назад +1

    Awesome video! I myself am a Contractor who works In Ontario, Canada. Where are you located and are you self employed? Good explaination of how everything works!

    • @HVACKnowItAll
      @HVACKnowItAll  5 лет назад

      Hey Michael, not self employed, most of my work is out of Mississauga

    • @michaelmead5880
      @michaelmead5880 5 лет назад +1

      @@HVACKnowItAll Right on! Good to see another competent Tech around. Are you mainly commercial service?

    • @HVACKnowItAll
      @HVACKnowItAll  5 лет назад

      @@michaelmead5880 yes pretty much

  • @ryanwilson3049
    @ryanwilson3049 4 года назад

    Thanks!

  • @totaltech8246
    @totaltech8246 5 лет назад +1

    #Dopeness

  • @MrAniven
    @MrAniven 3 года назад

    Hipster music

  • @jyphc1679
    @jyphc1679 5 лет назад +2

    I can’t ur voice because Background music

    • @HVACKnowItAll
      @HVACKnowItAll  5 лет назад +3

      I can hear my voice just fine...There a couple times when the wind is strong but that's life in HVAC