  • This method is only for emergencies, it is not recommended to be used forever, immediately replace one set of thermistors.
    If the thermostas cables are combined directly and the result is that the electricity supply to the outdoor unit is sometimes lost. So so that electricity from the indoor unit is sent to the outdoor unit continuously, the thermostat cables are combined using resistance.
    all these methods are only temporary, because the function of the temperature setting that is set from the remote does not work anymore.
    Hopefully meaningless
    greetings ainin jes

Комментарии • 401

  • @bergola7867
    @bergola7867 Год назад +7

    Mantab pak, sesuai dgn kendala ac sy, langsung praktek dan berhasil. Terimakasih konten yang sangat membantu 🥰

    • @segaladikerjakan
      @segaladikerjakan  Год назад

      Sama-sama 👍

    • @rizalelzuhdi7587
      @rizalelzuhdi7587 Год назад +1

      @@segaladikerjakan pak mau tanya ,saat termistor rusak itu kan katanya listrik tidak terkirim ke oudor? itu brati saat cek tespen di outdoor lampu tespen gak nyala ya? ini saya ada masalah. outdor mati tapi kabel yg dari indor tetep ada powernya. itu masalah dimana?

    • @segaladikerjakan
      @segaladikerjakan  Год назад

      @@rizalelzuhdi7587 tergantung power suply yg masuk ke indoor,jika terbalik bisa saja di outdoor unit jika di tespen listrik semua.

  • @rafaelgalih1469
    @rafaelgalih1469 Год назад +1

    Ini benar² bwt pemula..
    Utk yg udh ngertiii (Teknisi²)..
    SABAARR ya dengerin nya )Nyimaknyaaaa....

    • @segaladikerjakan
      @segaladikerjakan  Год назад +1

      bahkan kalau benar2 tnisi mah udah ga perlu nonton lagi gan,udah pada paham.

  • @sonikappa4120
    @sonikappa4120 2 года назад

    assalamualaikum bang Ainin Jes, makasih dah mau berbagi ilmunya, sangat manfaat buat yg nonton videonya moga berkah,ia moga sukses usahanya dan sehat slalu ya bang Ainin J amiiiiin 🙏.

  • @Satari-ih5wy
    @Satari-ih5wy 3 года назад +2

    Terima kasih suhu ilmunya semoga berkah. Aamiin

  • @dennydermawan8035
    @dennydermawan8035 3 месяца назад

    Ilmu bermanfaat.. trm ksh kang 🙏 sukses slalu

  • @wepaircomp
    @wepaircomp 10 месяцев назад +1

    Alhamdulillah berhasil di ac saya .

  • @herisupriatna2401
    @herisupriatna2401 Год назад +1

    Terimakasih tayangan videonya....👍

  • @benktyo
    @benktyo Год назад +1

    Mantap, mas. Working. Makasih. Tutorialnya. 🤗🙏

  • @tedisetiyanto4375
    @tedisetiyanto4375 3 месяца назад +1

    mksh ilmu'y pak guru

  • @pemanasair941
    @pemanasair941 2 года назад

    mantul q praktekan langsung greng hidup outdornya untuk sementara besok q beli thermistornya

  • @EdySutrikanto-gf6jr
    @EdySutrikanto-gf6jr 11 месяцев назад

    Mantap maaf pak kabel yg di sambungkan kurang jelas kemana sambung kanya pak trims pelajarannya 🙏

  • @dandre23ay
    @dandre23ay 2 года назад

    Oke.. bro.. mantap benar termistornyq putus gak taunya kabelnya

  • @ombob50
    @ombob50 2 года назад +1

    Makasih bang atas ilmunya 🙏🙏🙏
    Semangat terus bang 💪

  • @suwandasuwanda5108
    @suwandasuwanda5108 2 месяца назад

    Mantabbbbb

  • @mawarbodas1225
    @mawarbodas1225 4 года назад +1

    Siap terimakasih infonya

  • @gierschannel5858
    @gierschannel5858 Год назад +1

    Tq master berkongsi ilmu yang bermanfaat

  • @odexpuzzle5244
    @odexpuzzle5244 8 месяцев назад +1

    MNtap sekali

  • @bindershop7257
    @bindershop7257 3 года назад +3

    Terus terang kalau saya pribadi setiap berkunjung ke chenel siapapun selalu mengunjungi atau melihat dulu atau membaca dulu pettama deskripsi channel, kedua deskripsi konten, nah ternyata dari kedua deskripsi tersebut sata dapat informasi tambahan, sehingga saya tak lagi bertanya jika di kedua deskripsi tetsebut sudah di sampaikannya, terima kasih om admin atas semua yg di sampaikannya, semoga channel om ini membawa berkah baik untuk pengubjungnya maupun unrtuk adminnya. Aamiin

  • @modionsudi1649
    @modionsudi1649 2 года назад

    Tips yg sangat membantu.. 👍

  • @ketutsudirman2208
    @ketutsudirman2208 2 года назад

    bagus keterangannya murah ilmu....bravo ....sehingga saya like and Sabkaraib

  • @suryadisurya2411
    @suryadisurya2411 3 года назад +1

    Terimakasih banyak Pak

  • @bambangerucakra4605
    @bambangerucakra4605 2 года назад +1

    Assalamualaikum,
    Mantap bro... penjelasannya mudah dipahami dan dapat membantu permasalahan AC yang saya alami.
    terima kasih.

  • @ras2campboim628
    @ras2campboim628 4 года назад +2

    Bos tolong di kasih tahu cara mencari tahanannya ..dg multi tester..karena di video TDK kelihatan biar kita jelas.

    • @segaladikerjakan
      @segaladikerjakan  4 года назад

      kadang nilai tahan untuk memodif sementara tidak sama gan nilainya,lebih baik agan lakukan pengukuran thermistor ac punya agan berapa nilainya,nah nilai tersebut samakan dgn nilai tahan yg mau dibeli gan.

  • @cinolismika937
    @cinolismika937 4 года назад +2

    Joss tap mantap

  • @willdansholihin9624
    @willdansholihin9624 5 месяцев назад

    Kalau termis pipa yang rusak, apakah juga menyebabkan tidak ada suplai listrik ke outdoor??

  • @kukuhsuprihyatno6640
    @kukuhsuprihyatno6640 10 месяцев назад

    Malam bang. Aku punya ac panasonik. Autdor tidak mau hidup. Udah di ganti termis tidak mau hidup juga. Arus ke autdor kabel yala dua-duanya. Kalau kabel di lepas di indor, indor ngga mau hidup. Tapi kalau di pasang lagi kabel. Indor hidup tapi arus ya dua-duanya. Mohon petunjuknya. Makasih

  • @sontakong8404
    @sontakong8404 3 года назад

    Jelas. Gbu

  • @adejulistyo5542
    @adejulistyo5542 Год назад +1

    kang kalo ac midea yang termis dan termostat nya terpisah saya sambung langsung termostat udaranya indoor gak nyala malah muncul kode error E4. akhirnya saya sambung kembali termo udaranya dan indoor bisa nyala kembali. apakah ada cara untuk mengakali agar outdoor bisa nyala kembali?

  • @ludiromarlan4066
    @ludiromarlan4066 3 года назад +1

    Trimakasi pak..🙏

  • @cecepsupriatna12299
    @cecepsupriatna12299 10 месяцев назад

    Mau tanya Pak.. AC dirumah saya kondisinya sama persis seperti ini.. apakah untuk tipe LG inverter bisa dilakukan metode seperti ini, mohon pencerahannya 🙏

  • @deddyromadhon8331
    @deddyromadhon8331 11 месяцев назад

    trima kasih

  • @MRizky-bj5me
    @MRizky-bj5me 3 года назад

    Terimakasih atas ilmunya

  • @andisiswandaru2633
    @andisiswandaru2633 Год назад

    Ya Allah ...saya persis seperti ini kasus karna kabeln thermistor dimakan tikus pak...

  • @luckyer1995
    @luckyer1995 5 месяцев назад

    kalau termostat/termis rusak, berarti dia ga akan ada arus ke outdoor ya ?,soalnya saya cek di pin kabel outdoor yang di indoornya, ga ada arus.
    Klau cek termostat itu bisa dicek ga jika rusak atau tidak

  • @conquistadortl9892
    @conquistadortl9892 4 месяца назад +1

    Bang Ainin,setelah saya gabung kedua kabel thermostat acnya indoor nya ga mau nyala,kalo saya pisahkan baru nyala,tapi outdoor masih tetap ga mau nyala, mohon pencerahan please, makasih

    • @segaladikerjakan
      @segaladikerjakan  4 месяца назад

      kalau digabung langsung ga bakalan hidup gan,tapi harus dikasih resistor yg nilainya sama atau lebih-lebih dikit ga masalah dgn nilai thermostat tersebut ,lahi pula cara seperti itu tak disarankan tuk selamanya ,itu hanya untuk urgent ketika mau beli thermostat belum ready.

  • @megafoncell938
    @megafoncell938 4 месяца назад +1

    pak outdoor saya mati dan saya copot kabel nya cek testpen ada api fase nya. dan saya pasang kembali hidupin ac indoor tapi di outdoor ac nya gak hidup dan testpen kabel fase nya mati gk ada api. dan ac indoor nyala normal gak dingin.

    • @segaladikerjakan
      @segaladikerjakan  4 месяца назад

      iya itu artinya system indoor tidak bekerja,sehingga phase tidak terkirim ke outdoor unit saat indoor dihidupkan .ada beberapa hal yg bisa menimbulkan hal itu,termasuk themistor seperti dlm video,selain itu bisa juga relay di modul pcb indoor.

  • @mhdfajar6807
    @mhdfajar6807 Год назад +1

    Klw punya saya merek daikin pak.. Blower out door ngk hidup klw set tempratur 20 keatas
    Tapi klw set mentok 16 derajat out door nya hidup pak.. Kira kira apa nya nya yg oerlu di cek
    Terjadi masalah itu setelah pencucian out door pak.. Mohon bantuan nya pak

  • @vhalemetallecha
    @vhalemetallecha 10 месяцев назад

    Kalo daikin inverter siang tidak dingin dan tidak ngangkat kompresornya kenapa ya. Tapi kalo siram air outdoornya mau dingin lagi.

  • @ahmadanoval
    @ahmadanoval 2 года назад

    Outdoor tdk ada arus nya. Merk general. Apa yak takutnya kabelnya yg putus. Cara cek kabel putusnya gimana ya...

  • @onkchanel3482
    @onkchanel3482 4 года назад +1

    Mkasih mas

  • @u.s.a3063
    @u.s.a3063 Год назад +1

    Bng mau taya out dor puya ku d turunin k bawah trus sm aku pke kabel ac lalu d sambungin k pln ad suara denging kecil kipas g jln kompresor g jln biadanya apany outdor merk panasonic

    • @segaladikerjakan
      @segaladikerjakan  Год назад

      ac non inverterkah?....non inverter jika ada suara dengung seperti mesin susah star lalu hilang dengungnya setelah ada suara cetik,itu capasitornya gan,bisa jadi model capasitornya yg 1 set dgn capasitor mesin dan capasitor fan ,dua duanya rusak.

  • @yunkakapkaup-vb8zw
    @yunkakapkaup-vb8zw Год назад +1

    Pagi...bang mau tanya kalau AC Samsung indoor tidak mau konek ke outdoor penyebabnya apa ? Jadi operan ke outdoor tidak keluar strumnya.

    • @segaladikerjakan
      @segaladikerjakan  Год назад +1

      ada beberapa hal yg bisa terjadi, 1.kabel menuju outdoor putus karena terlalu kecil atau kalau ada sambungan putus disambungan, 2.bisa set thermistor, 3.bisa Relay di modul ,4.bisa daya menuju relay dimodul tidak masuk/lemah.

  • @dekawo4139
    @dekawo4139 2 года назад

    Mantap bang

  • @dedyprasetiyo6635
    @dedyprasetiyo6635 Год назад +1

    Om punya saya AC changhong udah ganti termistor dan really indoor tapi out kok masih belum nyala tapi di konekkan kabel pada outdoor 1 dan 2 nya ada api listriknya, gmn solusinya?makasih

    • @segaladikerjakan
      @segaladikerjakan  Год назад

      gan,itu indoor atau modul posisi lagi hidup cek arus yg masuk ke coil relay apakah sesuai dgn kebutuhan volt coil tersebut,jika kurang bahkan tidak ada ya coil relay tidak akan ngonec

  • @raffaelanakbetawi7684
    @raffaelanakbetawi7684 4 года назад +3

    Klo di outdoornya ada power tapi gk hidup juga out doornya itu gimana ya ak?
    Outdoornya bunyi ngontek tapi blower outdoor gk mau hidup..mohon sarannya? Makasih

    • @segaladikerjakan
      @segaladikerjakan  4 года назад +2

      maaf saya balik tanya dulu ya mas,apakah sama sekali fan blower di outdoor tersebut tidak mau berputar ?.........dan hanya kedengaran ada suara cetek saja?..........terus merek acnya apa mas?........dan sudah pemakaina berapa tahun kira2?........

    • @raffaelanakbetawi7684
      @raffaelanakbetawi7684 4 года назад +1

      Iy pak,fan blowernya gk nyala ,ada bunyi cetek di outdoor...
      Panasonik...
      Timernya kedip merah pak?

    • @segaladikerjakan
      @segaladikerjakan  4 года назад +1

      @@raffaelanakbetawi7684 siap mas,untuk ac panasonic yg sudah freon R32 body unit outdoor warna abu2 tua,permasalahan tersebut berada di capasitornya yg rusak baik capasitor compresornya maupun copasitor fan blowernya ,jadi untuk jenis ac seperti itu capasitor compresor dgn capasitor fan blower jadi satu barang ,cuman beda penempatan jek scoketnya saja .

    • @segaladikerjakan
      @segaladikerjakan  4 года назад +2

      @@raffaelanakbetawi7684 untuk beli capasitor baru samakan ukuran UF nya dgn capasitor yg rusak tersebut sebagai contoh.

    • @raffaelanakbetawi7684
      @raffaelanakbetawi7684 4 года назад +1

      Baik pak,coba sya beli kapasitornya ,
      Maksih banyak pak,atas jawabannya..
      Sukses selalu pak..
      Kontennya bagus..
      Saya akan subcribe chanel you tube nya...👍🙏

  • @caturlifelive
    @caturlifelive Год назад +1

    ijin tanya om, saya punya ac tcl 09cs/zl jadul. Ac baru saya servis bulan desember kemarin (meliputi perbaikan kebocoran, pengisian freon, dan pembersihan). Dari desember sampai januari, ac hanya sy gunakan 6-7 kali alias jarang sy gunakan
    Saat ini Outdoor ac sy mati di menit 2-3 setelah ac dinyalakan. Ketika outdoor nyala, ac dingin. Tapi karna outdoor keburu mati, ruangan jd tidak dingin. Karna teknisi yang kemarin servis ac sy tidak ada kabar, sy nekat coba benerin sendiri. Menurut video2 d youtube, sy disarankan ganti thermistor. Akhirnya sy ganti thermistor sesuai tipe ac saya, tapi stelah sy pasang, outdoor tetap hanya menyala 2-3 menit saja. Mohon sarannya om,
    Sebelumnya maaf jika kepanjangan dan trima kasih

    • @segaladikerjakan
      @segaladikerjakan  Год назад +1

      Set thermistor khan ada 2, yg satu sebagai deteksi suhu ruangan/thetmostat dan satunya lagi sebagai deteksi suhu pipa/thermis , bisa jadi yg sebagai deteksi suhu pipa/thermis , pipanya tidak begitu dingin, coba pindahkan penempatan thermis ke pipa paling dingin yaitu pipa di pangkal pipa yg baru datang di evap.

    • @segaladikerjakan
      @segaladikerjakan  Год назад +1

      Di ikat biar nempel itu thermis di pipa yg pertama paling dingin.

    • @caturlifelive
      @caturlifelive Год назад

      @@segaladikerjakan thermis yang berbentuk cilinder berwarna tembaga barusan sy cb taruh d pipa utama yg sy rasa dingin, tapi outdor ttap mati d menit 3 om. Ada saran om?
      Sebelumnya trima kasih nggih

    • @segaladikerjakan
      @segaladikerjakan  Год назад +1

      @@caturlifelive apa yakin di menit pertama outdoor terdengar bisa star itu kompresornya?.....

    • @segaladikerjakan
      @segaladikerjakan  Год назад +1

      @@caturlifelive kalau sudah yakin di menit pertama outdoor mesin compresor sempat star lalau set thermistor sudah baru,lalu permasalahannya tetap sama saja,hanya tinggal satu bossku, sepertinya dimodul arus yg ke rilay drop kurang dari capasitas yg terteran di rilay tersebut,contohnya di riley tertera 12 volt DC saat awal star normal 12volt,tetapi sekian menit kedepan drop menjadi contohnya hanya 6volt ,maka si riley akan off mengirim arus ke outdoor unit.ini semua harus cek modul,ukur volt yg menuju ke riley.

  • @dullchanel5974
    @dullchanel5974 Год назад

    Itu berlaku juga untuk AC Mitsubishi inverter g om?? Mohon di jawab

  • @ayclotv8592
    @ayclotv8592 9 месяцев назад

    Pak apakah AC samsung saya juga bisa pak ?
    Krna problem nya sama .. 😢
    Misal hari ini hidup sampai pagi saya matikan , malamnya udah ga bisa .. besoknya bisa lagi .. apa bisa dilakukan sprti ini pak ?

  • @dikaramadhan3620
    @dikaramadhan3620 10 месяцев назад

    Klok di indor ada apinya tapi di outdor ny gk ada
    Apa masalah ny pak ..(untuk kasus autdor mati dan kipasnya)

  • @septedianadiana1178
    @septedianadiana1178 2 года назад

    Pak saya punya ac merk mitsubishi klu dinyalahin setelah konek keoutdor indornya pasti mati kanapa yh?

  • @ardiswg2517
    @ardiswg2517 2 года назад

    Mau tanya Pak...AC sy akari turbo cool 1/2 PK kompresor nggak nyala tp kipas nyala, outdoor hanya hembusan angin. Sdh ganti thermistor, kapasitor & overloud. Mohon pencerahannya 🙏🙏

    • @segaladikerjakan
      @segaladikerjakan  2 года назад

      kalau itu mesin compresor sudah di ganti kapasitornya dan tetap terdengar kompresor susah star ,itu masalahnya sudah di kpmpresor gan,kompresor macet.

  • @foxerxgaming8306
    @foxerxgaming8306 Год назад

    TQ mas ilmunya....Minta halal ya ilmunya

  • @saktimas7719
    @saktimas7719 Год назад +1

    Om kl ac panasonic ecotough indoor dinyalain tp kompresor sama fan lama hidup skitar 3 mnt stelah indoor nyala,kapasitor baru ganti tp merk NC bukan original,kira2 knp ya?
    Makasih

    • @segaladikerjakan
      @segaladikerjakan  Год назад

      Untuk awal di beri power listrik itu ac khan emang sekitar 2 hingga 3 menit indoor bisa memberikan listrik ke outdoor unit, tapi nanti setelah pemakaian, on off nya dari remot, indoor unit hanya hitungan detik baru mengirim listrik ke outdoor unit.

    • @saktimas7719
      @saktimas7719 Год назад

      Oh gt..sipp om thx ya

  • @jafarsidiq1883
    @jafarsidiq1883 2 года назад

    Saya punya kasus AC merk Daikin Thailand 1pk, indor nyala normal. Tapi outdoor nya mati. Setelah di ganti kapasitor nyala sebentar lalu mati total dua dua nya indor dan outdoor. Kira kira apa yg harus di cek pak?

  • @hilmanmuttaqien
    @hilmanmuttaqien 3 года назад +2

    Kang masalah ac sya jga sama kya bgtu, ac samsung outdoor nya tidak mutar, kata tehnisi sih harus ganti modul pcb nya ,

  • @hobirumahan85
    @hobirumahan85 Год назад

    Tidak terkirim totaly di tespen tidak ada api atau nyala dua dua kabel pak de

  • @riyangokil3960
    @riyangokil3960 Год назад

    Bang sama kasus seperti itu outdoor gk mau nyala², tapi kalo on dari manual mau nyala itu kenapa ya?

  • @jaemishel7634
    @jaemishel7634 4 года назад +2

    Suhu mau tanya AC sy kondisinya seperti itu persis merk Midea , mau coba jumper pake termostat lain. Karena nyari di online susah untuk merk Midea, pertanyaan sy apakah thermistornya bisa diganti sama yg universal? Atau misalkan pake merk lain yg cocok merek apa ?

    • @segaladikerjakan
      @segaladikerjakan  4 года назад +1

      mas bos berhubung saya belum pernah ngalami permasalahan thermostat di ac merek midea ,jadi saya ga bisa menyimpulkan bisa tau tdaknya dgn merek lain biasanya hanya beda di soketnya saja,cuman solusinya coba mas bos itu thermostat ac midea di ukur dgn avometer digital menunjukan berapa ohm,maka dgn merek lain juga samakan saja itu nilai ohm nya,yg penting nilai ohm yg media dgn yg pengantinya jgn lebih rendah nilainya.

    • @jaemishel7634
      @jaemishel7634 4 года назад +2

      @@segaladikerjakan setelah saya cek termostatnya ternyata berair , saya panasin pake korek terus saya bungkus kepalanya pake selang aerator, Alhamdulillah outdor langsung nyaut,,, tapi lg saya pantau' kembali EC lg apa sehat lg AC saya, kalo EC lg baru sy ganti itu termostat. Tapi belum Nemu toko online Midea/offlinenya 😁
      Makasih suhu penjelasannya detail, ilmunya bermanfaat bgt

    • @segaladikerjakan
      @segaladikerjakan  4 года назад

      biasanya kerusakan thermostat itu tidak langsung putus tetapi saat di kasih arus listrik dari modul nilai ohm jadi sangat rendah sehinnga tidak mampu memberikan sinyal ke komponen yg lainya di modul tersebut ,jadi thermostat kalau kita ukur dgn avometer posisi dilepas dari modul nilai ohm itulah yg harus sama nilainya dgn penggantinya lebih2 dikit tidak apa2 yg penting jgn lebih rendah itu penggantinya.

    • @segaladikerjakan
      @segaladikerjakan  4 года назад

      oke mas bos, perhatikan itu penyimpenan thermostat kepala thermostat jgn sampai menyentuh evapolator harus renggang dari evapolator.

    • @jaemishel7634
      @jaemishel7634 4 года назад

      @@segaladikerjakan maaf suhu bukan teknisi sy jadi gakpunya alat" buat ngeceknya hehe..

  • @juariajja763
    @juariajja763 4 месяца назад

    Bang warna tahanannya apa, yg nilainya 13,2.🙏

  • @haikalchennel2775
    @haikalchennel2775 Год назад +1

    Bng apa tremostat itu ada tipe atau merek2nya

    • @segaladikerjakan
      @segaladikerjakan  Год назад

      disesuaikan saja dgn merk ac nya saja boss, contoh ac merk panasonic ya tinggal bilang saja beli thermostat untuk ac panasonic ,hanya saja ada soket besar dan soket kecil

  • @BYPRODUCTIONBusmuria
    @BYPRODUCTIONBusmuria 3 года назад

    Klau kapasitor nya mati trus gmn ..apakah bisa d cek seperti ni

  • @carelcarolus
    @carelcarolus Год назад

    Outdoor ac lg dualinverter sy mati hidup mati hidup
    Knp yah? Tq

  • @abut5620
    @abut5620 2 года назад +1

    Kasus sama Daikin 1/2 pk R410. Sudah Thermis nya sudah ujung nya di bakar -> Sudah di ganti pake Thermis baru -> hasilnya Outdor kipas & Kompresor menyala cuman sebentar terus mati 😭

    • @nurfitriyadi4469
      @nurfitriyadi4469 Год назад

      Trs apanya bang permasalahnnya

    • @abut5620
      @abut5620 Год назад

      @@nurfitriyadi4469 bocor Evaporator kak. Bocornya di ujung jadi harus ganti, saran saya lebih baik di Potong seluruh u-bend nya kak lebih awet 👍👍👍

    • @nurfitriyadi4469
      @nurfitriyadi4469 Год назад

      @@abut5620 mf sblmnya ini..apa hbngnya kk dgn bocor..kn kasusnya bru d hidupin trs sbntr mati..kl.setau saya kl freon bocor ac kurang dingin..aplgi itu bocorny hlus..

    • @abut5620
      @abut5620 Год назад

      @@nurfitriyadi4469 saya udah ganti Overload & termis masih aja kak 🤦, coba saya cek outdoor yg nyala aja di bypass langsung ke listrik, kalo nyala Terus sampai 15-30 menit berarti outdoor normal kak.

    • @abut5620
      @abut5620 Год назад

      @@nurfitriyadi4469 lebih pastinya sih kak liat indoor apakah ada oli keluar di sela2 evaporator. Berarti problemnya di evap bocor kak. Selama sistem kelistrikan AC masih berfungsi normal itu yang saya tau kak pengalaman saya maklum saya bukan teknisi cuman sharing pengalaman aja kak

  • @wirasatria9728
    @wirasatria9728 11 месяцев назад

    Kalau di konekin langsung Outdornya menyala, tapi kalau dari Indor di cek ada listrik pakai tespen tapi tidak mau juga menyala
    Solusinya gimana bang ?

    • @segaladikerjakan
      @segaladikerjakan  11 месяцев назад

      iya betul itu permasalahannya ada di system modul indoor, bisa dari 1 set thermistor,bisa juga relaynya ,bisa juga volt yg menuju ke relay yg bermasalah.

  • @agusirwanto7483
    @agusirwanto7483 Год назад

    Kl ac inverter bisa dibuat kayak gitu bang?

  • @SocratesDionisius
    @SocratesDionisius 6 месяцев назад

    Kalau thermostat baik, tp msh blm nyala knp pak?

  • @arissutaat4947
    @arissutaat4947 2 года назад

    Sy ada problem pak,.
    Ac nasional outdor mati,.saat ac di nyalakn, selang 5 mnitan ada suara cetek pda relay ,lalu ac restart(mati hidup lgi)
    Apkah ciri" tersebut krusakan di termostart?

  • @agsmstudio
    @agsmstudio 3 года назад +1

    kl punya saya kasusnya kl di nyalakan pakai remote indor hidup,outdor gk mau hidup...
    kl di nyalakan manual dr tombol indor hidup,outdor hidup TAPI kl saya nyalakan remot,nya outdor langsung mati.....itu apanya yg rusak gan?
    mohon jawabanya.....

    • @segaladikerjakan
      @segaladikerjakan  3 года назад +1

      ac standar apa ac inverter gan?....

    • @agsmstudio
      @agsmstudio 3 года назад

      @@segaladikerjakan
      kayaknya standar gan...
      merk LG baru kemarin kl di nyalakan dr remote outdor gk mau nyala.....

    • @segaladikerjakan
      @segaladikerjakan  3 года назад

      @@agsmstudio oke gan kau setingan remote udah merasa benar, yaitu di posisi cool dan temperatur di seting paling rendah dulu ,langkah berikutnya agan ganti batu baterai dgn yg baru, atau kalau punya remote ac LG yg lain bisa test dgn remote yg lain dulu.

    • @agsmstudio
      @agsmstudio 3 года назад

      @@segaladikerjakan
      siapp.....besok di coba ganti batre baru gan...kl utk settingan di remote sudah benar gan....terimakasih utk balasanya gan,semoga sukses dan berkah.....

    • @agsmstudio
      @agsmstudio 3 года назад

      @@segaladikerjakan
      sudah di coba ganti batre remot gk bisa jg gan...
      ini kl di nyalakan manual bisa nyala indor dan outdornya,tp ntr mati sendiri indor dan outdornya

  • @cecepdedihidayatj8125
    @cecepdedihidayatj8125 3 года назад +1

    Out door ada arus tapi saat di koneksikan langsung nol,apa penyebabnya ya guru,tolong bantuan arahannya

    • @segaladikerjakan
      @segaladikerjakan  3 года назад

      gan kalau tidak terbalik itu power L dan N nya di indoor unit ,maka L yg menuju outdoor unit itu tergantung dari system di indoor unit.coba pastikan dulu power yg masuk ke indoor unit jgn terbalik.

  • @kangmasrahmad191
    @kangmasrahmad191 4 года назад +1

    Ac saya merk panasonic 1pk, setelah termis sudah diganti baru hanya bertahan minggu. Solusinya gimana ya bro??

    • @segaladikerjakan
      @segaladikerjakan  4 года назад

      jadi hanya sempat normal seminggu saja kang bos?.....sekarang outdoor unit kembali lagi tidak dapat arus listrik dari indoor unit?.....coba cek volt DC yg masuk ke rilay kang bos.

    • @kangmasrahmad191
      @kangmasrahmad191 4 года назад

      Siap....

  • @sandyelzandraa
    @sandyelzandraa 3 года назад +1

    Mau nnya pak. Thermisnya sudah sy cek normal pak. Tapi outdoornya tetap tidak mau hidup sama sekali.
    Pada saat AC sy nyalakan. Kabel netral sy tespen malah nyala pak. Tapi ke outdoor tidak nyala tespennya.
    N-1-N-L
    Hasil tespen : N(hidup)-1(mati)-N(hidup)-L(mati)
    Kalau seperti ini kenapa ya pak?

    • @segaladikerjakan
      @segaladikerjakan  3 года назад

      udah ketemu belum permasalahannya gan?....saya baru baca selengkapnya komen agan,itu dari power saja sudah terbalik gan,coba ikutin power N pasang untuk netral dan L pasang untuk arus listrik. jika merasa thermistor di anggap normal.

    • @dp4939
      @dp4939 2 года назад

      @@segaladikerjakan bang kalo arus yg normal nya itu gimana misal L N 1 2 jadi L (mati apa hidup) N(mati apa hidup) 1(mati apa hidup) 2(mati spa hidup)

    • @segaladikerjakan
      @segaladikerjakan  2 года назад

      @@dp4939 yg komen diatas itu karna power supply masuk indoornya terbalik gan ,dan ngetesnya hanya memakai tespen ,maka dari itu ikutin L arus listrik in to indoor( harus nyala )jika ditespen ,N netral in to indoor, maka hasilnya saat ac di hidupkan angka 1 itu adalah listrik out to outdoor (harus nyala} dan angka 2 adalah Netral out to outdoor.

    • @dp4939
      @dp4939 2 года назад

      @@segaladikerjakan jadi Netral yg out in to outdor nya harus nyala gak kalo d tespen

    • @segaladikerjakan
      @segaladikerjakan  2 года назад

      @@dp4939 semua yg namanya netral di tes pakai tespen tidak nyala

  • @jayaGani
    @jayaGani Год назад

    bang kalo kita diatur suhu 25 apa arus listrik putus ngak ke unit outdor atau unit outdor hidup trus....?

  • @thomsrhj8594
    @thomsrhj8594 Год назад +1

    Kalo ac saya kompresor idup tapi kipas mati yg outdoor gmn ya.apakah ganti termistor?atau kapasitor luar yg harus ganti?

    • @segaladikerjakan
      @segaladikerjakan  Год назад

      cek kapasitor fan

    • @thomsrhj8594
      @thomsrhj8594 Год назад

      @@segaladikerjakan itu soket ada 4 biji yg 2 gak tersambung soket apa bisa hanya di ganti ke sebelahnya bang?atau ganti baru?

    • @segaladikerjakan
      @segaladikerjakan  Год назад

      @@thomsrhj8594 oke,di fan outdoor unit itu model kapasitor yg satu paket dgn kapasitor kompresor beli baru saja ,dan samakan model/ukuran uf nya ,jika sampean baru pertama mau mengganti supaya pemasangan kabelnya tidak salah pasang,dipoto dulu sebelum dilepas ,dan pastikan arus listrik powernya di lepas dulu demi keamanan.

    • @thomsrhj8594
      @thomsrhj8594 Год назад

      @@segaladikerjakan siap matur suwun infone mas

    • @thomsrhj8594
      @thomsrhj8594 Год назад

      @@segaladikerjakan oiya mase kalo misal ac d nyalakan sinyal indoor memberi sinyal ke outdoor supaya kipas di luar sama kompresor tapi telat kadang gak hidup itu sebenernya kapasitor fan apa kapasitor yg kaya tabung itu yg d ganti mas?

  • @starunboxing7052
    @starunboxing7052 3 года назад +2

    Saya uda ganti relay seperti itu.. tapi ga lama kemudian sekitar 15menit mati lagi, dan sampe seterus'a bgtu jdi outdoor'a ga nyala lagi, jdi itu penyebab'a knp ya mas?

    • @segaladikerjakan
      @segaladikerjakan  3 года назад +1

      kalau yg di video itu bukan relay gan,apa udah di ganti thermisnya gan?....

    • @starunboxing7052
      @starunboxing7052 3 года назад

      @@segaladikerjakan uda di ganti gan..

    • @segaladikerjakan
      @segaladikerjakan  3 года назад

      @@starunboxing7052 pindahkan saja gan posisi peletakan thermistor sensor pipa ke pipa yg paling dingin gan,ikat gunakan kabel tis,pipa yg paling dingin itu pipa pangkal evap gan. nah di ikatkan saja sensor pipa disitu.

    • @segaladikerjakan
      @segaladikerjakan  3 года назад

      @@starunboxing7052 jangan lupa cek tekanan gas freonnya gan,bisa jadi di bawah standar itu takanannya cuman belum sampai jadi es.

    • @starunboxing7052
      @starunboxing7052 3 года назад

      @@segaladikerjakan ok gan, nnti akan saya coba.
      Thanks..

  • @wijayamukti5000
    @wijayamukti5000 3 года назад

    Manteppp

  • @mfebriharizal1705
    @mfebriharizal1705 Год назад

    Malam pak, mau nanya, ac samsung 1 pk, indor hidur namun arus listrik ke outfor tidak ada, boleh kasih saran pak apa yg harusbdi cek pak?

    • @segaladikerjakan
      @segaladikerjakan  Год назад

      yg apaling mudah dulu pertama cek mode di remote harus di posisi cool atau simbul pendinginan,lalu suhu di remote test dulu di posisi angka paling rendah, jika masih tetap cek set thermistor jika langsung diganti juga sangat-sangat murah, nah disini harus yg sediki paham elektro jika masih tetap juga cek dimodul arus yg menuju riley apakah normal ada DC 12volt atau ada juga yg memakai 24volt ,jika ada dan normal berati riley rusak .

  • @ekonur1302
    @ekonur1302 3 года назад

    ac saya masalah seperti itu. sudah tak coba ganti thermistor blm bsa juga. sampai tak hantu relay, capasitor masih tetap bsa. cak coba pakai tespen disoket kabel N, 1 dan 2 ada arus listrik. kira kira itu masalahnya dimana ya om. 🙏

    • @segaladikerjakan
      @segaladikerjakan  3 года назад

      iya gan,jika yg disampaian sudah di ganti masih tetap ga bisa ,perlu mendasar lagi untuk pmeriksaan komponen yg lainya terutama di bagian IC progam,yg kami sampaikan di video tersebut itu part yg sering mengalami masalah ketimbang komponen2 yg lainnya gan. kalau boleh tahu ac apa yg agan miliki?.....

  • @mohammadazri4048
    @mohammadazri4048 2 года назад

    Tahanan itu gimana gak ngerti gw... Ngak pham pake apa tahanan nya pakkk

  • @maralkimi7853
    @maralkimi7853 3 года назад

    Mau tanya pak, Ac saya samsung inverter indoor hidup outdoor mati, kipas tdk berputar, suara kompresor tdk ada sm sekali. Tapi sy cek arus listrik.pakai tespen si outdorrnya ad pak. Itu kondisi ac di nyalain. Tp ketika ac di matiin arus listrik di outdor tdk ada. Mohon informasinya terimakasih

  • @ZahirKhan-fh6iu
    @ZahirKhan-fh6iu 3 года назад +1

    Bang AC shap r22,,tekanan 60 psi Amper 1,8, operlod baru,capasitor baru,awal nya nyala,dan normal tapi stlah dimati kan,dan di hidup kan lagi komprsor terkunci Amper 5 berulang brkali2 spti itu,kenapa bisa sprti itu bang?

    • @segaladikerjakan
      @segaladikerjakan  3 года назад

      berapa PK gan?....

    • @ZahirKhan-fh6iu
      @ZahirKhan-fh6iu 3 года назад

      Setengah PK bang

    • @ZahirKhan-fh6iu
      @ZahirKhan-fh6iu 3 года назад

      Di bodi tertulis 1,9A

    • @segaladikerjakan
      @segaladikerjakan  3 года назад

      @@ZahirKhan-fh6iu standar kenormalan tekanan freon 22 itu 70 hingga 80 gan,berarti itu kalau di normalkan tekanannya pasti amper naik,nah sekarang pastikan dulu gan indoor maupun outdoor dlm keadaan bersih kadang ac sudah lama di pakai nampak depan kelihatan bersih padahal di dalam masih numpuk kotor,kalau perlu di cuci service besar gan bongkar turunkan.

    • @segaladikerjakan
      @segaladikerjakan  3 года назад

      lalu pastikan juga listrik di rumah itu voltnya tidak kurang dari 200volt gan.

  • @ahmadanoval
    @ahmadanoval 2 года назад

    Ac outdoor sy. Saat awal start remote berapa menit msh ada arusnya ke outdoor namun tetap mati total si outdoor tsb. Setelah berapa menit arus dari indoor ke outdoor tsb hilang. Apa itu yg rusak ya..apa itu thermostate ya yg rusak..

    • @segaladikerjakan
      @segaladikerjakan  2 года назад

      saat awal di off pakai remote kali ya gan?.....ac jenis apa gan.standar apa inverter?.......

  • @cakagusarmo
    @cakagusarmo 2 года назад

    indoor dan outdoor tidak ada hembusan angin saat AC posisi ON,dan tdk dingin.padahal power di outdoor ada di dua kabel L N(pakai tespen).dan indikator timer blingking terus.kira" apanya mas yg bermasalah?

    • @segaladikerjakan
      @segaladikerjakan  2 года назад

      cek dalaman dinamo fan,biasanya sensor dalam dinamo ada kotor yg dibawa sembut bahkan banyak semut yg pd mati

  • @alexandreberek7168
    @alexandreberek7168 3 года назад +3

    Om bisa ngak minta no wa supaya nanti ad permasalahan ac bisa minta masukan

  • @fikryrafi5074
    @fikryrafi5074 Год назад

    Makasih,jk AC seharian out dor mati ,tp pas malamnya normal nyala LG Brrti kenapa ya om

  • @pemanasair941
    @pemanasair941 4 года назад +1

    Deskripsi akunnya oke juga tuh

  • @littleboyel5345
    @littleboyel5345 3 года назад

    Bosque mau tanya ..AC sy sharp noninventer ...indoor nyala outdor mati tdk ada arus listrik ke outdoor, apakah ada hubungannya sama riley dan pcb modulnya ,Ac br 2thn , krn tehnisinya g bisa benerin secara memuaskan dan minta ganti pcb modulnya ..mohon penjelasan

    • @segaladikerjakan
      @segaladikerjakan  3 года назад

      ada bungan dgn rriley tapi belum tentu riley pak,yg paling mudah itu ganti dulu 1 set thermistor murah banget ko dari pada riley

    • @segaladikerjakan
      @segaladikerjakan  3 года назад

      sedangkan riley bisa di ukur dulu untuk memastikan rusak tidaknya dgn avometer ,dgn posisi riley di lepas dari pcb

    • @littleboyel5345
      @littleboyel5345 3 года назад

      Trus yg punya abang ini cm termistornya yg di ganti y .. riley dan pcb tak ada masalahkah?

  • @roberthvictorimmanuelsireg5059
    @roberthvictorimmanuelsireg5059 2 года назад

    termostart yang di maksud, termis suhu ya..,,

  • @SocratesDionisius
    @SocratesDionisius 6 месяцев назад

    Kalau indoornya TDK hidup knp ya pak?

  • @chaeronsyah
    @chaeronsyah Год назад

    Tp, di ac2 baru, akan terbaca eror thermis

  • @raka663
    @raka663 3 года назад

    Bang mau tanya. Ac split
    Indor 3/4
    Out door 1 pk
    Kondisi ac dingin. Ruangan dingin. Tp kompresor ga mau putus. Udah ganti termis. Ganti overload. Bahkan pcb sdh diganti juga. Mohon pencerahan nya

    • @segaladikerjakan
      @segaladikerjakan  3 года назад

      Udah di coba setel remot di 25 atau 26 apa masih tetap ga mau berhenti itu outdoor unit

    • @raka663
      @raka663 3 года назад

      @@segaladikerjakan tetap ga mau mati juga

    • @segaladikerjakan
      @segaladikerjakan  3 года назад +1

      @@raka663 kalau sekedar tes thermostat efektif tidaknya coba baikan lagi pelan pelan 27 hingga paling tinggi

    • @raka663
      @raka663 3 года назад

      @@segaladikerjakan ok sy coba. Tks arahan nya

  • @ckddaun1067
    @ckddaun1067 2 года назад

    Kang kabel 1 dan2 kalau dilihat pake tespen arusnya dua duany nyala atau satu aja

    • @segaladikerjakan
      @segaladikerjakan  2 года назад

      Satu lah kang boss itupun ketika indoor unit sudah mulai di on

  • @vermiehans
    @vermiehans 2 года назад

    AC Daikin saya juga ga nyala outdoor nya.. mana nyari outdoor 2nd yg 1/2 pk susah bgt karena katanya sudah jarang yg pake 1/2pk.. banyakan yg 1pk & 2pk.. itu kalau outdoor nya ga nyala ga bisa dibenerin kah??.. harus ganti outdoor baru??..

    • @segaladikerjakan
      @segaladikerjakan  2 года назад

      Dari hasil pemeriksaan itu outdoor unit rusak di bagian apa?

    • @vermiehans
      @vermiehans 2 года назад

      @@segaladikerjakan kompresor nya katanya..

  • @rickykristian7240
    @rickykristian7240 3 года назад

    Gree inverter error e6..tidak menyala outdoor nya gmn ya pak

  • @anjasmorohadiwibowo1609
    @anjasmorohadiwibowo1609 2 года назад

    Izin mas .. indor saya hidup outdorsaya kompresornya hidup tapi kipas outdornya gamenyala

    • @segaladikerjakan
      @segaladikerjakan  2 года назад

      Biasanya yg sering terjadi capasitor fan outdoor rusak.

  • @egadavinnovianto3884
    @egadavinnovianto3884 2 года назад

    Misi om klo arus listrik ada (tespen) jika kabel indoor tidak dihubungkan ke outdoor tpi jika dihubungkan ke outdoor saya tes di tempat sambungan kabelnya ke outdoornya kok ga ada arus listrik ya ? Kenapa ya om ? Soalnya outdoornya tidak mau nyala karna tidak ada aliran listrik om ke outdoornya jika disambungkan , terimkaasih om
    Oh iya om permasalahanya indoor nyala berfungsi normal tapi outdoor mati total (sudah ganti kapasitor outdoor dan thermistornya)

    • @segaladikerjakan
      @segaladikerjakan  2 года назад

      Klau hanya menggunakan tespen tidak maksimal, coba gunakan avometer di posisi volt dan nyalakan indoor, apa 220volt ada keluar dari indoor

  • @tahyadicahyadi3195
    @tahyadicahyadi3195 3 года назад

    Bang AC panasonic ecotoc suplay listrik yg ke audtdor hidup mati hidup mati.termis dan relay udah di ganti parion normal suhu di posisi cool 16 derajat.apa pnyeb nya bang.atau kh modul indor yg rusak

    • @segaladikerjakan
      @segaladikerjakan  3 года назад

      itu yg di ganti thermis pipa apathermis udara?...

    • @tahyadicahyadi3195
      @tahyadicahyadi3195 3 года назад

      @@segaladikerjakan yg di ganti ke dua nya mas.termis panasonic.

  • @nismarawiwo8968
    @nismarawiwo8968 3 года назад

    Kang punten ikut bertanya.
    Ac sy sharp r32 indoor hidup,tapi outdoornya mati,baik kompresor maupun fannya.
    Udh cb ganti kapasitornya masih tetap mati.
    Oia,ada arus d kedua kabel N(1) dan 2 outdoornya.
    Kira2 apanya y kang.
    Nuhun pisan.

    • @segaladikerjakan
      @segaladikerjakan  3 года назад +1

      itu artinya indoor unit sama sekali ga mamapu memberikan arus listrik yg normal,pertama ganti yg mudah dan murah dulu yaitu satu set thermistor,jika thermistor sudah diganti masih ga mau hidup jiga ,ganti relaynya kang boss

    • @nismarawiwo8968
      @nismarawiwo8968 3 года назад

      @@segaladikerjakan ok siap kang nanti d coba.nuhun pisan sudah d respon.
      Sy subkreb.hehe

  • @januardisihombing3477
    @januardisihombing3477 2 года назад

    Bang,, mau tanya kalau ac inventer panasonik 2 PK,, indoor nya menyala dan lampu timer menyala,, Outdoornya ga menyala sama sekali... apanya tuh bang?

    • @segaladikerjakan
      @segaladikerjakan  2 года назад

      bagaimana sudah teratasikah?.....pertama power supply dilepas dulu gan tunggu sesaat lalu pasang kembali coba hidupkan kalau masih tetap ga bisa ,test dgn menganti thermistor gan.

  • @raihanardo8997
    @raihanardo8997 3 года назад

    AC Uchida saya, kabel termostat t sambung jadi satu AC malah tidak nyala,saya kembalikan k semula in door nyala tapi out door tetep tidak nyala,kira2 permasalahan d mana ya gan?

    • @segaladikerjakan
      @segaladikerjakan  3 года назад

      pertama pastan seluruh unit ac bersih dari debu2 yg menempel,lalu tetap ganti saja itu thermostatnya gan,lagi pula kalau bisa di akalin jga sipatnya sementara.

  • @anggafachriza8635
    @anggafachriza8635 2 года назад

    Mass saya mau nanya...AC DAIKIN saya Outdoor tiba2 mati, tapi Indoor nyaa aktif/nyala dan terasa dingin...dgn suhu 27 .... penyebab nyaa apa... apakah Outdoor nyaa rusak...Tks.

    • @segaladikerjakan
      @segaladikerjakan  2 года назад +1

      itu normal bossku,outdoor unit akan mati dan hidup secara otomatis menyesuaikan suhu yg sudah tercapai di ruangan tersebut

    • @anggafachriza8635
      @anggafachriza8635 2 года назад

      @@segaladikerjakan Ooo gitu...okee deh makasih yaa masss infonya...👍💪🙏🙏