How to set up a VEGAPULS radar sensor with PACTware | Tutorial

Поделиться
HTML-код
  • Опубликовано: 23 авг 2024
  • Users can accomplish an in-depth set up of their VEGAPULS radar sensor using a laptop with the PACTware setup software installed. This tutorial walks users through the steps needed to get their level measurement radar sensor up and running in just a few minutes. To download the free PACTware software, visit: www.vega.com/e...

Комментарии • 6

  • @Emaaduddin28
    @Emaaduddin28 2 года назад +4

    You should go into False signal suppression in future videos. Many customers usually have doubts about how to do False Signal Suppression.

  • @sambasivamR-gh5ig
    @sambasivamR-gh5ig 4 месяца назад +1

    What will be the reason for sudden spike in output to reach maximum and come back normal and also is these radar detect all the objects and human interference.

    • @VEGA_Level_Pressure
      @VEGA_Level_Pressure  4 месяца назад

      Hello, Thanks for your question. There can be different reasons for jumps to a higher level, for examples false signals from filling stream, build up or similar things. To determine where exactly the jumps are coming from the echo curve and the installation has to be checked. For further help please contact your local subsidiary: www.vega.com/en/company/vega-worldwide

  • @blue-ribbon-sparkler
    @blue-ribbon-sparkler 4 года назад

    Cool!

  • @garyverth4887
    @garyverth4887 3 года назад

    So failure high of 21mA will indicate 100% or more on the DCS?

    • @VEGA_Level_Pressure
      @VEGA_Level_Pressure  3 года назад

      Hello, thanks for your question. Upon a sensor failure (i.e. Loss of level signal) the current output can be set to fail high, which will send 21 mA creating a 100% full level indication at the PLC. The sensor can also be set to fail low, sending 3.6 mA indicating 0% at the PLC. The sensor can also be set to hold last known value. The output failure should be selected as needed for the application. If the output is digital, a failure message can be sent to the controller indicating there is a problem, since current output is not effected on the digital loops. Feel free to contact us directly if you have further questions: www.vega.com/en/company/vega-worldwide