Walk in cooler not cooling

Поделиться
HTML-код
  • Опубликовано: 24 ноя 2024

Комментарии • 86

  • @jeramymann5397
    @jeramymann5397 4 года назад +1

    Ty for showing the mistake. These types of days are the worst. Appreciate you.

  • @WackyWRZ
    @WackyWRZ 4 года назад +5

    Woot another curious HVAC video!! I really enjoy watching these! Thank you!

  • @bigclivedotcom
    @bigclivedotcom 4 года назад +8

    I hate those days when lots of little time-consuming things happen. It feels like time flies by with no results.
    Good targeted advertising - I got an ice-machine advert on your video.

  • @RayRay-nb7tn
    @RayRay-nb7tn 4 года назад +1

    Good video on a common mistake everyone makes on a daily basis. We all make them in way or another. When you restock your van put 2 of each evap fans on your truck one to put in one for stock. Each rotation. Looked at on of these low profile unit the other day I couldn't believe how clean the evap coil was. Unit it 3 yrs old out in a common area for customers to walk in. Basically a room with to low profile units. Nice video thank you. Be safe be good.

  • @KALZONE850
    @KALZONE850 4 года назад +2

    I like that you included the the wrong motor rotation installation part. Most would have left that out. great vid keep em comin

  • @HVACRSurvival
    @HVACRSurvival 4 года назад +6

    And here I thought I was the only one that had things like this happened to me. I wish I didn't get upset like you LOL.

  • @terrytugwood7848
    @terrytugwood7848 4 года назад +4

    Really like watching your videos, they’re interesting, informative and when you make a mistake you don’t hide it. Great work 👍👍

  • @adamlee3810
    @adamlee3810 4 года назад +1

    Always one thing after another. Glad you got time to put out another video. Really enjoy watching these.

  • @twistedcandlecompany
    @twistedcandlecompany 4 года назад +1

    Happy to see you posting videos again. Thanks for sharing

  • @throttlebottle5906
    @throttlebottle5906 4 года назад +2

    barse ackwards rotation LOL.
    we all have those days, if it can be done wrong the first time it will! some of us sometimes insists on doing things thrice before it's right. it's always easier from the chair watching ;)

  • @EverythingHVACR
    @EverythingHVACR 4 года назад +2

    Great video, nothing is ever easy! One thing after the other, welcome to commercial refrigeration 🤣😂

  • @shine-cg9uf
    @shine-cg9uf 4 года назад +1

    Great video. I worked on a low profile but I had another guy with me. Much respect on solo mission. Can b a pain but all good. U the man!!

  • @winkhvac62
    @winkhvac62 4 года назад +1

    Good targeted advertising AGREE 100%

  • @sterlingarcher46
    @sterlingarcher46 4 года назад +1

    I've got the exact same old school thermometer , mate , the ol' reliable trusty cooper .
    Great minds my friend 👍

  • @curntischavis7788
    @curntischavis7788 4 года назад +1

    Man your a great teacher really enjoyed the video the steps you showed us where amazing!!

  • @epsteinvelho6566
    @epsteinvelho6566 4 года назад +2

    Pls tune up for uploading more vedios

  • @alessichris07
    @alessichris07 4 года назад +2

    I started stocking the ecm version its reversible and covers a wide range of watts
    They are more expensive for the customers but more convenient for me
    P.s. love your videos

  • @jonnymac31
    @jonnymac31 4 года назад +1

    Sweet man. Those cooper atkins meters are nice.

  • @FlyEaglesFly19111
    @FlyEaglesFly19111 4 года назад +2

    Thanks for sharing.. stay curious my friend.

  • @shawns6135
    @shawns6135 3 года назад +1

    I’ve done the same thing with a fan motor, more times then I’d like to admit. I’m at the point now where it’s the first thing I do is check the rotation.

  • @stephenhunter70
    @stephenhunter70 4 года назад +3

    And naturally if their ever asked all the clients staff say "it wasn't me".

  • @analogmoz
    @analogmoz 4 года назад +5

    It really seems like that box WANTED to stay at 50. Stat resets, fan motor dies out, etc.
    You have violated the will of the cooler, Bill. There will be consequences.

  • @Ted_E_Bear
    @Ted_E_Bear 4 года назад +4

    Be careful, Curiosity killed the cat !

  • @kcomfortsystemshvac7060
    @kcomfortsystemshvac7060 4 года назад +1

    Bill ,,,,,great. Video,,,,,,how is you thing going,,,,? Best regards,,,lorenzo,,,,,👍👍👍

  • @andymaurer7972
    @andymaurer7972 4 года назад +1

    Sometimes a job never goes easy you can get a call for a easy fix and i turns out to be a mess sometimes it gets really bad when its very old. But you can only do so much

  • @ronaldclark8187
    @ronaldclark8187 4 года назад

    Good call.

  • @reyrodriguez1005
    @reyrodriguez1005 4 года назад +1

    If you made more videos you’d have way more subscribers. Always dig your content, Dude 🤙🏽

    • @curioushvacguy6876
      @curioushvacguy6876  4 года назад +1

      Your right, the last few months I havent had much of anything good enough to video- as soon as I get something good though itll be on here

  • @jrh86
    @jrh86 Год назад

    Thank you

  • @gregbowman3598
    @gregbowman3598 4 года назад +1

    Good one Bill

  • @rocker8692
    @rocker8692 2 года назад

    I'm going make some stickers for me,good idea.

  • @minigunnathaniel
    @minigunnathaniel 4 года назад +1

    Like what HVAC videos says always look at the big picture

  • @randytorboli
    @randytorboli 4 года назад +1

    Great video bill

  • @larryproffitt4729
    @larryproffitt4729 3 года назад +1

    A little to late for that fan direction tip as I have already learned the hard way. LOL

  • @airconditioningrefrigerati5837
    @airconditioningrefrigerati5837 4 года назад +1

    Good work 👍👍👍👍

  • @harrydickson4575
    @harrydickson4575 4 года назад +2

    👍👍👍

  • @eddieg780
    @eddieg780 4 года назад +3

    So the thermostat was switching at the box temp. Could you have moved the wire from the yellow terminal to the blue? Was the thermostat just replaced before you got there by someone else?

    • @throttlebottle5906
      @throttlebottle5906 4 года назад +3

      it likely had burnt contacts inside, the blue terminal opens on temperature rise, while yellow closes, red is common of the spdt switch. Johnson Controls (A19ABC-74C) if I had to guess. but may have been fixed differential model :)

  • @johnnysaltyaircrabcake8030
    @johnnysaltyaircrabcake8030 4 года назад +1

    Duck Dynasty Refrigeration Company

  • @Mr.Schitzengigglez
    @Mr.Schitzengigglez 2 года назад

    If I'm not mistaken, reversing the polarity on that fan motor, would have reversed the fan direction, and gotten you your desired results.

  • @RJMaker
    @RJMaker 4 года назад +1

    SPDT.... It matters.. :-)

  • @HughesManHVAC
    @HughesManHVAC 4 года назад +1

    Nice video 👍

  • @lwilton
    @lwilton 4 года назад +9

    I thought when you were fiddling with it that the old thermostat turned on when you turned it up above 50 and turned back off when you turned it back down. I was wondering if someone had been playing games and reversed the wiring on that SPDT switch on the thermostat.

    • @brainndamage
      @brainndamage 4 года назад +8

      the wires on the thermostat were on wrong, set up for heating instead of cooling. It either never worked right or someone just replaced it

    • @bigclivedotcom
      @bigclivedotcom 4 года назад +3

      That was going through my mind too. Maybe a previous effort by a dabbler.

    • @Froggability
      @Froggability 4 года назад +2

      So, most likely nothing wrong with the old thermostat, just miswired. Can't have been long ago

    • @bigclivedotcom
      @bigclivedotcom 4 года назад +3

      @@Froggability Sometimes it throws you when you come across stuff that has been interfered with by other people before you arrived. Especially when you don't know they've "modified" it.

    • @raygale4198
      @raygale4198 4 года назад +1

      @@bigclivedotcom I do a bit or repair work for Vietnamese restaurants, I love the food. Covers mysteriously lose screws, adjustments move, parts even change but nooooo one has touched it, no sir noooo one.
      The standard MO seems to be they call you, you give them a quote they then call a local 'handyman' who says I can do that for half the price, using your quote as a diagnostic tool. He then cobbles in second hand miss matched parts and vanishes in a puff of cigarette smoke as soon as he has cash in hand. 2 Weeks later you are back with an even bigger quote and a very unhappy customer, but they keep using unlicensed handymen.

  • @ranjitchahal3084
    @ranjitchahal3084 Год назад

    Nice video

  • @KG-yn9qi
    @KG-yn9qi 4 года назад +1

    Poltergeist.....

  • @stevenhughes6548
    @stevenhughes6548 4 года назад +4

    Wire was on wrong terminal, should have been on blue not red.

    • @joehead1294
      @joehead1294 4 года назад

      www.grainger.com/ec/pdf/Johnson-Controls-A19-Series-Remote-Bulb-Control-Data-Sheet.PDF

  • @clintglasgow5633
    @clintglasgow5633 4 года назад +1

    👍

  • @steveblake8766
    @steveblake8766 4 года назад +1

    #203 thumbs uP

  • @publicmail2
    @publicmail2 4 года назад +1

    Whats the reason for a pump down, I realize its to keep liquid from the compressor, but is it for less parts and simplicity able to short cycle too?

    • @Froggability
      @Froggability 4 года назад +1

      Avoid the liquid component chilling down too much during off-cycle, which could harm the compressor

    • @curioushvacguy6876
      @curioushvacguy6876  4 года назад

      It helps with refrigerant migration and allows the compressor to reach its normal running compression ratios much faster

  • @pepsicolachao4537
    @pepsicolachao4537 3 года назад +1

    You thought you were done with the repair... nope! One of the fan motor on the evaporative coil failed!
    As per usual, one thing leads to another

  • @andreeriner811
    @andreeriner811 Год назад +1

    You have days like I have l9l

  • @KG-yn9qi
    @KG-yn9qi 4 года назад +1

    I know why your back bad when not so long ago, you he manned everything... now you pay the price.... I had the hardest time trying to tell young guys to think use equipment to aid them.. let the winches etc. Do the lifting ( oil rig work, I was the driller/ tool pusher). They tought they were tough up to when they would hurt themselves.. of course I would reply Told ya!!!

  • @matthewross4567
    @matthewross4567 4 года назад +1

    Those thermostats are JUNK get a ranco etc

  • @nilborne1
    @nilborne1 3 года назад +1

    want to hit like but you have 665 likes so...