Sir ya Jo ap discharge battery bta rhy hain is k kia mtlb hai? Mean hmra jitna load hai like hmra load 2.5kw hai to battery ki discharge setting kitni rakhain gy? Guide me plz
Aoa, Rameen bhai nitrox 2022 black wale model main battery values % ki bjae volts main hain . kaise calculate ho gi or osaka 1800 4 batteries ko hum 70% drain tk ki kya values dain ge . or kya hum smartload ko completely off kr sakte hai. pls is pr bhi video bna dain aik. thx
AOA, I have GRID charge enabled, The WAPDA is available, but still it show Off-grid, and it's not charging, in-fact running load from battery backup? What can be the issue? Inverext nitrox 6kw
Also higher Amp can do this, so I set my amp 28 to charge the battery. Also make sure the Time of use is unchecked and the GRID charge in grid settings/ or in battery setting is checked. (if you know this)
Sir yeh tu batain capacity battery ki AH kia rakhen ge aik ki rakhen ge yani agar 185 ah ki tublar battery hai to 185x4=740 AH Capacity rakhen ge inverter nitrox main
Aoa Sir, Manay recently Inverex Nitrox 8kv with (4) Inverex 220ah Batteries install ki hn .First day pe manay battery test kia tha battery ko full 100% charge kr k almost load under (800-600) watt thaa or isny mashallah sy 12 hours ka backup diaa phir subha solar sy battery charge hogayi thi full again raat ko battery sahi chalri thii lekin jesy hi below 40% pe ayi F56 ka error ana shuru hogaya ??? Please iska koi solution bataein
mere pas nitrox 5 kw watt hai, 4 batteries phonex tuballar 230 ki lgi hen, charging amp 20 a p hai wapda p charge amp 15 hai, ab msla ye hai ke batteries se pani overflow ho rha hai or batteries ke ander carban jma horha hai, batteries or inverter new 4 mah phle lgaya hai, ye overflow q ker rha hai?
Well done brother ... mara sat nitrox 12 kW wala inverter ha . Ham na heavy load batteries pa 5 % rahka ha or 95 % light load rahka ha lakin jab night ma bijli jati ha to heavy load around 4 kW hota ha 2 min bad AC ka sat pora inverter off ho ka beep start kar data jab sab off kar data han tab batteries load utha data ha... error F 56
Nice Sir Khadim Hussain apke shagird ki truf se ustad ji ko salam
Nice information Sir
Sir Very nice infomation for batrey charging.
All doubts clear. Thank you.
zbardast....very well explanation
So far nitrox inverter and their ios team unmatchable 👍
Sir iss me ye b btaye k diffrent time k hisaab se kesy grid se battery charge kr skty hy this is incomplete battery info .
Sir ya Jo ap discharge battery bta rhy hain is k kia mtlb hai? Mean hmra jitna load hai like hmra load 2.5kw hai to battery ki discharge setting kitni rakhain gy? Guide me plz
Best explanation Sir
What if we want to turn off grid charge? Meaning I don't want my bettaries to be charged on grid but only on solar. Should I turn off Grid Charge?
Very informative
Aoa, Rameen bhai nitrox 2022 black wale model main battery values % ki bjae volts main hain . kaise calculate ho gi or osaka 1800 4 batteries ko hum 70% drain tk ki kya values dain ge . or kya hum smartload ko completely off kr sakte hai. pls is pr bhi video bna dain aik. thx
Zabardast bro
kia just wapada dey setting pa click ker dakh saktein hn ya pv ya battery lagni zaroori hy
Good information sir . Sir it means nitrox has very good system for batteries Management. BMS. And battery equalization. System
Aoa sir kiaa hum nitrox main din ka time wapda automatic off kar sakta hain jo sham ko jaisa solar off ho wapda on ho jaya
Do you have in stock hybrid inverter of inverex nitrox 8kw ip65 ? Need in Lahore price and availablity please waiting thanks
Salam
Sir can you tell me nitrox 5k Working with single source . I mean if there is no grid power and if there is no battery, then can we run on solar .
NITROX MUST NEED BATTERIES FOR GRID OR SOLAR
MEANS solar use karna hou ya wapda batteries must attached karni hain
AOA, I have GRID charge enabled, The WAPDA is available, but still it show Off-grid, and it's not charging, in-fact running load from battery backup? What can be the issue?
Inverext nitrox 6kw
did u find a fix ?
@@QwertyQq-uh3ec The voltage or frequency was low.
So for voltage I used low 170 and high 264
And frequency 47 to 53
Same for reconnect after
Also higher Amp can do this, so I set my amp 28 to charge the battery. Also make sure the Time of use is unchecked and the GRID charge in grid settings/ or in battery setting is checked. (if you know this)
Very nice information but very poor camera work
Nice
is me 100 ah ki 4 battaries laga skte hain?
Please explain equalization hours for dry batteries, why you left zero hours?
Sir yeh tu batain capacity battery ki AH kia rakhen ge aik ki rakhen ge yani agar 185 ah ki tublar battery hai to 185x4=740 AH Capacity rakhen ge inverter nitrox main
Pylon tech battery connection to this inverters specially communication cable how to connect
Sir f56 nitrox ka common error hai junkay batteries bi new kindly guide krain
Mere sath b same issue araha hai app guide karen main 20 din pehle system install kia h with 6 kw nitrox tublar battries hain 185 AH ki
Aoa Sir, Manay recently Inverex Nitrox 8kv with (4) Inverex 220ah Batteries install ki hn .First day pe manay battery test kia tha battery ko full 100% charge kr k almost load under (800-600) watt thaa or isny mashallah sy 12 hours ka backup diaa phir subha solar sy battery charge hogayi thi full again raat ko battery sahi chalri thii lekin jesy hi below 40% pe ayi F56 ka error ana shuru hogaya ??? Please iska koi solution bataein
When attaching 16 tubular batteries of 245 ah . What battery capacity should i insert into inverter bat capacity section . Kindly inform .
ruclips.net/channel/UC_-oYLT7K2jE0nO3fN8mtjg
Plzzz mery channel ko subscribe kr do
245Ah
Sir Nitrox 3kw ki bi seting bi bata do plz
Sir ham isko ye kese btyege k 1400 tx tubler bettery h to kese btye k kitne ampair krne h
mere pas nitrox 5 kw watt hai, 4 batteries phonex tuballar 230 ki lgi hen, charging amp 20 a p hai wapda p charge amp 15 hai, ab msla ye hai ke batteries se pani overflow ho rha hai or batteries ke ander carban jma horha hai, batteries or inverter new 4 mah phle lgaya hai, ye overflow q ker rha hai?
Can you explain activate battery function in battery settings.
ruclips.net/channel/UC_-oYLT7K2jE0nO3fN8mtjg
Plzzz mery channel ko subscribe kr do
Sir battery capacity setting kasa kara mara battery tx 2500 ho phonex ke hai
bhai agar 3400mah ki 4 tubular batteries hon to battery capacity mai kya figure likhain?
Sir battry 200Ah ki hen pr 4 batries hen.. phir battry setting me Battry capacity 200Ah rakhain ya 800Ah?
200Ah.
Well done brother ... mara sat nitrox 12 kW wala inverter ha . Ham na heavy load batteries pa 5 % rahka ha or 95 % light load rahka ha lakin jab night ma bijli jati ha to heavy load around 4 kW hota ha 2 min bad AC ka sat pora inverter off ho ka beep start kar data jab sab off kar data han tab batteries load utha data ha... error F 56
Facing similar error. Koi solution mila aapko?
Koi solution mila ?
Voltage fluctuations ki waja sae rast mae batries consume ho rahi haen is ka kia solution hae
ایک بیٹری بینک سے دو انورٹرز کنیکٹ کر سکتے ہیں ؟
پلیز راہنمائی فرمائیں شکریہ
Can anyone here tell how to charge battery using grid power? Mene yehi setting ki hai battery charge nhn horhi.
Price kia ha Nitrox Ki
Plz reply
Bakwas