How to wire a zone to your alarm system - magnetic door switch, passives and beam shown - tutorial

Поделиться
HTML-код
  • Опубликовано: 29 ноя 2024

Комментарии • 58

  • @danieloraseanu
    @danieloraseanu 3 дня назад

    Thank you for your time spent on this and the clear, detailed way you did it!

  • @kenmorton2571
    @kenmorton2571 Год назад +2

    Excellent, Thank you so much for showing this, it was easy to follow and you did not speak to fast !!

  • @tonyfelix8655
    @tonyfelix8655 5 месяцев назад +2

    Thank you very much sir, i was able to connect my alarm system with your excellent explanations, thanks for your sharing

  • @candymancam2390
    @candymancam2390 Год назад +1

    Excellent explanation! Congratulations !

  • @warrenpfo
    @warrenpfo 3 года назад +4

    Fantastic. Your videos just keep getting better keep up the great work. Could you please do a video on how to wire and connect wireless accessories to panel.

  • @koolohinde
    @koolohinde Год назад

    Thank you south africa.

  • @micdev42
    @micdev42 2 года назад +2

    Brilliantly explained. thanks for making the effort.

  • @RajabKasanga
    @RajabKasanga Год назад +1

    Excellent brother like the way you explained thank you

  • @kieranmurphy1091
    @kieranmurphy1091 3 года назад +2

    This subject is very well explained and thanks for that

  • @samuellazarus1107
    @samuellazarus1107 2 года назад +1

    Great video. Answered all my questions.

  • @georgekaloudis170
    @georgekaloudis170 Год назад +1

    Excellent explanation! Nice job. Thank you for this well informing video!

  • @Jay-tr3px
    @Jay-tr3px 2 месяца назад

    Hi. Thanks for the great video. What is the alarm panel that you are using and power supply is needed to operate?
    I need to hook a magnetic switch to this with a horn alarm. thanks again.

  • @brendonmurphy3591
    @brendonmurphy3591 3 года назад +2

    Thanks for the video, it was really informative. I own a IDS X64 alarm with 16 zones, and would like to add an additional keypad as well as another 8 zones. Can you please make a video on how to add an additional keypad, including setting it up. As well as how to add an additional zone expander. My current zone expander plugs straight onto the main board. Keep up the good work.

  • @juliusmbugua6980
    @juliusmbugua6980 Год назад +1

    Very helpful illustration

  • @MelinyanisoMapi
    @MelinyanisoMapi 11 месяцев назад

    Great video guide, you make this seem so easy, question...can i use Xwave 2 wireless indoor Detector with my Ids x64?, if so help would be appreciated on the how?

  • @kaveshmaharaj533
    @kaveshmaharaj533 Год назад

    Thanks for sharing these videos. May I ask, I have an IDS x64 alarm panel. I want to install an outdoor PIR. The one I am keen on is the Takex wired 180 MX-12FAM. Is the Takex compatible with the IDS system. I have not been able to find an answer to this. My logic tells me that there is no reason it won't be compatible. I just need to make sure. Appreciate your advice.

  • @danielburger1116
    @danielburger1116 5 месяцев назад

    Thank you for fantastic tutorial.. I am struggling with door open close that triggers after some time. Why does it do that? The contacts are not moving, they are also in a standard position which worked normally for nine years, now the door triggers after some time every time.

  • @africanhistory
    @africanhistory 2 года назад

    finally the video I beam looking for.

  • @trevorcamm1906
    @trevorcamm1906 2 года назад

    Your video helped me so much to understand and to check if my alarm was connected correctly. One question I have is that my infrared beams are connected as you described. I have three that have been connected to zones 6, 7 and 8 on and they work, but even when they are on, off or triggered they do not show on the keypad. I ask because I know people with the same beams that show on their alarm keypad unlike mine.

    • @stevenweii
      @stevenweii Год назад

      Why don’t you replace your beam with a simple door contact to see if a triggered door sensor cause alarm on the zone, if it does then you have problems wiring the beam, if it doesn’t then you have problems programming your alarm panel.

  • @chchan2733
    @chchan2733 Месяц назад

    Great tutorial.

  • @nicholasamiadamhen2563
    @nicholasamiadamhen2563 3 года назад +1

    Thanks for the video ,,well explained

  • @alaamardawi5962
    @alaamardawi5962 5 дней назад

    clear and useful

  • @juliangordon7567
    @juliangordon7567 2 года назад

    Do you have any videos on connecting the xwave wireless components?

  • @novacaldera6181
    @novacaldera6181 Год назад

    Brilliant video. What happens when you want to add a zone beyond 8?

  • @nosignal3831
    @nosignal3831 3 года назад +1

    Thank you Mr Sir this one is the1

  • @456hihisense3
    @456hihisense3 3 года назад

    How does one connect two pirs/beams in seies or parallel? What is the better option : parallel or series? I was amazed at the above video presentation.

    • @ecologicaltime
      @ecologicaltime  3 года назад

      ill do a video to show. May take some time

    • @456hihisense3
      @456hihisense3 3 года назад

      @@ecologicaltime no problem. I can wait. Thank you.

    • @456hihisense3
      @456hihisense3 3 года назад

      Any luck with the video

    • @456hihisense3
      @456hihisense3 2 года назад

      I'm still awaiting your response.

  • @africanhistory
    @africanhistory 2 года назад +1

    finally got my beams working

  • @UnknownMelodies0
    @UnknownMelodies0 3 года назад +1

    Thanks this was very helpful;)

  • @alvinmari3162
    @alvinmari3162 3 года назад +1

    Do you have one on vibration sensors? Good video.

  • @aliuibrahim638
    @aliuibrahim638 3 года назад +1

    Nice one

  • @crazyethanyeahyeah
    @crazyethanyeahyeah Год назад

    Great video!

  • @alarmr1269
    @alarmr1269 3 года назад +1

    Good video. Subscribed

  • @andyp9131
    @andyp9131 2 года назад

    hi i have 3/8 dor contacts with a veritas v8 alarm panel but can't see no wire in my door or door frame they cant be wireless can they thanks in advance andy

  • @adil391
    @adil391 Год назад

    Could you do one for the texecom premier version

  • @moirakyle4759
    @moirakyle4759 Год назад

    I have a problem with a door sensor. Can i permanently disarm it at the door end rather than at the control box?

  • @nikolaspanagiotousecurity
    @nikolaspanagiotousecurity Год назад

    How you choose the oms of the resistors to use?

  • @Kimdalgomis
    @Kimdalgomis 3 года назад +1

    your amazing

  • @matsuz100
    @matsuz100 3 года назад

    why did you add a resistors? And the resistor what is it's impedance?

  • @danielmeyer677
    @danielmeyer677 2 года назад

    I need help. My pir sensors work but the light doesn't come on indicating that the sensor has detected motion. I have a ids x64 alarm system plz help thanks

  • @vishnugovender1401
    @vishnugovender1401 3 года назад +1

    Top stuff

  • @RajabKasanga
    @RajabKasanga Год назад +1

    Perfect

  • @matsuz100
    @matsuz100 3 года назад +1

    You should explain not all panels require End of line resistors.

    • @xcpointx
      @xcpointx 3 года назад

      The system actually has 3 states : open, closed, fault.
      Closed : resistance of x ohms
      Open: open circuit full resistance
      Fault: Between 0 and x ohms (this can happen if wires partially touch or become abraded and connect )

  • @firos_khan
    @firos_khan Год назад

    please make a video AVS intrusion alarm system

  • @Rayray-ox7ln
    @Rayray-ox7ln 2 года назад

    ids 805
    dont knw how to program. please help. i want to put delay on my zone 1 and 2. change password(pin) and use zone 8 as sensor.
    how to do ?

  • @boneymaunduslim3838
    @boneymaunduslim3838 2 года назад

    thanks

  • @IconicFashionBarbie
    @IconicFashionBarbie 2 месяца назад

    I don’t know how to configure on my dsc pannel

  • @WYCINKA-DRZEW-JUMPER
    @WYCINKA-DRZEW-JUMPER 2 года назад

    remote control of the SP4000 paradox on and off of the RSU-KO1 / S remote control how to connect

  • @Kimdalgomis
    @Kimdalgomis 3 года назад +1

    why we aadd resistors

    • @ecologicaltime
      @ecologicaltime  3 года назад

      alarm panels often use resistors as it allows for more reliable voltage across the sensor. Small change in wire resistance does not impact the alarm.