  • @matthewjohnson3408
    @matthewjohnson3408 2 года назад +18

    “Please can someone send me greenline laser!!!”……….Alternatively, you could go and purchase one like the rest of us have to do! Don’t mind me, I’m just jealous! Great video guys!!

    • @anthonybragg
      @anthonybragg 2 года назад +2

      1 OF 200 Meger testers
      will be given out to the RUclipsrs for free no chance of the rest of us getting one.

  • @Vwfan
    @Vwfan 2 года назад +3

    Great teamwork. Competence and experience prevails. Well done lads. Jordan will be so proud of you. ❤️👍🏼

  • @tcpnetworks
    @tcpnetworks 2 года назад +3

    Lee and Luke smashing out good stuff again...

  • @Gobbbbb
    @Gobbbbb Год назад

    6:25 - Absolute genius

  • @dannyte83
    @dannyte83 2 года назад +4

    Off the top of my head isn’t 4mm rated at 30amp for ref method B ? 🤫
    Nevertheless, love that tester 😉

  • @paulerasmus8917
    @paulerasmus8917 2 года назад +1

    Been looking for the 1741+ in black but never managed to find one. Great looking bit of kit

  • @andyclark1426
    @andyclark1426 2 года назад

    Love the black megger

  • @Davidhughes9467
    @Davidhughes9467 Год назад

    Just out of interest do you allow a day labour for that job? Great job looks nice.

  • @tom4kills28
    @tom4kills28 2 года назад +6

    Did you fix the hot tub in the end?

    • @michaels8336
      @michaels8336 2 года назад +3

      This, why is the video cut short, we have seen a million charger installs, it would have been good to see the troubleshooting of the hot tub issue.

    • @mb-electricalservices
      @mb-electricalservices 2 года назад +1

      @@michaels8336 We couldn't have these "perfect installs" interrupted by a problem now could we......:D

  • @tc6907
    @tc6907 2 года назад

    Great video guys!
    Could you do a short video on your set up of the testing bag?

  • @CurtainFlapper
    @CurtainFlapper 2 года назад +4

    I found the background music a little loud on this video, when I set the volume of the music to a nice level Lee was quiet and I couldn't understand what he was saying. Please lower music next video. Great content though guys

  • @willhurd7777
    @willhurd7777 2 года назад

    Well done lads great vid and great work

  • @bradleyswainson9319
    @bradleyswainson9319 2 года назад +1

    I've got a question about the SPD iso you're using, what's the spec? I could see Hager but if I get asked to do a retro fit in the future it would be useful to know👍😃

  • @niallmacneill5525
    @niallmacneill5525 2 года назад

    I’m only a phase 3 apprentice and I’d love one of them testers

  • @JensenPGATourDriven
    @JensenPGATourDriven 2 года назад

    Great work guys & l like new black tester , Lee ⚡️👊

  • @robed1984carly
    @robed1984carly 2 года назад

    Genuine question
    Can I ask the purpose of putting it on an RCD at the board. I thought you didn’t need one on a Zappi?, and cable is all surface mounted. Is it because you couldn’t re-config the board to make a way not on the RCD?
    Thanks

  • @Cablesmith
    @Cablesmith 2 года назад +2

    Awesome tester 😎

  • @benjurqunov
    @benjurqunov 2 года назад

    In US. using a ’Megger is pretty much unheard of.
    Said that, I use mine frequently checking out motors.

  • @krtelectricalservices
    @krtelectricalservices 2 года назад

    Were the two Wiska boxes connected together with another or just butted up?

  • @hreadbackup
    @hreadbackup 2 года назад

    Hey guys, where abouts did you get your fleece jackets from if you dont mind me asking?

  • @lblake586
    @lblake586 2 года назад +3

    Wagos on data cable ?

  • @JNET_Reloaded
    @JNET_Reloaded 2 года назад

    the cable will be a different lengh so might aswel fit it and then test it after you fit it!

  • @clivelong383
    @clivelong383 2 года назад

    Hi Lee what make is the meter

  • @anthonygregory9290
    @anthonygregory9290 2 года назад +4

    How did you connect the isolator without pulling the main fuse? :P

  • @calvinmcmahon2714
    @calvinmcmahon2714 2 года назад

    I see you haven't installed separate double pole rcbo protection so if the zappi does require immediate isolation or under fault conditions your also isolating every other circuit protected by the rcd you have installed in the existing c/u

  • @whytejavoy5028
    @whytejavoy5028 2 года назад

    Good work

  • @nicolasoraison8288
    @nicolasoraison8288 2 года назад

    Can you get 3 phase power in a general domestic house in the uk ?

    • @samjburns07
      @samjburns07 2 года назад

      If you pay ~£10k yes, very rarely they're installed in new builds

  • @conorcampbell7639
    @conorcampbell7639 2 года назад

    Can you do video on good budget brands and tools help apprentices cause some are so expensive to get

  • @chrisgoodwin3617
    @chrisgoodwin3617 2 года назад

    I want my consumer unit changed. Only Artisan will do for me. Jordan, is Northampton too far out of your area?

    • @artisanelectrics
      @artisanelectrics  2 года назад

      Hey Chris, if you fill in an enquiry form on our website we’ll take a look into this for you 👍🏻

  • @MrSJT
    @MrSJT 2 года назад

    I had a chance to buy one 2 years ago, didn't know they only made 200, I ended up getting a Metrel 3152

    • @Waynesworldofgaming
      @Waynesworldofgaming 2 года назад

      I’d rather the metrel myself anyway mate 👌🏻

    • @MrSJT
      @MrSJT 2 года назад +1

      @@Waynesworldofgaming I like that Metrel can test type F and B+ RCDs but Megger can't, but I do like Meggers build quality though

    • @artisanelectrics
      @artisanelectrics  2 года назад +1

      We have tried both and the Megger definitely wins

    • @Waynesworldofgaming
      @Waynesworldofgaming 2 года назад

      @@artisanelectrics yes a lot of people tell me that tbf, but I’m happy with my metrel so I’ll probably keep it until it dies on me 🤣

    • @MrSJT
      @MrSJT 2 года назад

      @@artisanelectrics I used to use Megger, I guess whichever suits your needs the most wins

  • @AGRElectrics
    @AGRElectrics 2 года назад

    Luke... She won't be doing it again now 🤣 wp though 👍

  • @malcolmone1
    @malcolmone1 2 года назад

    could have a faulty hot tub

  • @Beariam24
    @Beariam24 2 года назад

    Got mine on day of release, mine dose not look shiny like that anymore 😭😭😭😭😭

  • @whytejavoy5028
    @whytejavoy5028 2 года назад

    I from Jamaica

  • @ForTheBirbs
    @ForTheBirbs 2 года назад

    Just curious - this video seemed rushed as it's a lot shorter than in the past. Will this be the normal?

    • @artisanelectrics
      @artisanelectrics  2 года назад +2

      Hey Jim, we are trying out mixing up the content with a few shorter vids here and there but don't worry, there's plenty more full length content on the way!

    • @ForTheBirbs
      @ForTheBirbs 2 года назад

      @@artisanelectrics thank you! Fantastic

  • @TheRealCrAzYShOTTAHD
    @TheRealCrAzYShOTTAHD 2 года назад

    Just realised Lee has a tattoo of a burd with tig ol bitties on his arm

  • @Spark101.
    @Spark101. 2 года назад

    4mm twin and earth, installed using installation reference method B has a rating of 30 amps. Why have you installed a 32 amp MCB for this circuit? Sorry lads, but thats a Code 2 on the next EICR! !! Potentially Dangerous !!
    Nice job overall lads, but these details are more important than looking pretty on camera with pretty looking test equipment, and fancy expensive battery tools. Good working knowledge of the wiring regulations outweighs all of that……and ultimately leads to a safer installation.
    I’d go back ASAP and either upgrade the cable or change the installation method. I don’t suppose this was cheap for the customer. 2 of you at more than £90 per hour + VAT. (EACH!). To be fair…..This install shouldn’t be paid for until it is installed in accordance with BS7671.

  • @ASour1170
    @ASour1170 2 года назад

    Although it's nice, I'd still rather Lee's van than the Megger

  • @Yorkshiretrebor
    @Yorkshiretrebor 2 года назад

    Thanks for watching another video, I'll just stab my screwdriver into the hot tub cover. 🙄

  • @brianhewitt8618
    @brianhewitt8618 2 года назад

    48v ?

  • @waynenrich
    @waynenrich 2 года назад +1

    No he’s married to the job

  • @carforumwanker
    @carforumwanker 2 года назад

    So megger reps need to be asked "Why are you giving so much away for free just to get good reviews"

  • @Caducus40K
    @Caducus40K 2 года назад +1

    Not only pulling the main fuse but removing meter seals and connecting into the smart meter.. I think qualified electricians should be able to remove main fuses however we are not permitted and certainly not permitted to cut into meter companies seals / meters. As a professional company it seems pretty poor that you have done this.

    • @rollthetape88
      @rollthetape88 2 года назад

      what other option did they have?

  • @cj-rb8fz
    @cj-rb8fz 2 года назад

    No fire clips in trunking 🙄🙄 cable run in cavity 🙄 insulation test carried out with out load connected 🤔 and fitting isolator on dno equipment 😮

    • @stupot_64
      @stupot_64 2 года назад

      Isolator was fitted after the meter.

    • @cj-rb8fz
      @cj-rb8fz 2 года назад

      @@stupot_64 yes but you’ve still had to cut the seals on main fuse and pull that or do it live , by the looks of it was done live as smart meters normally send signal it’s been switched off and they send meter fitter out and charge you for visit

  • @MariaMartin-q8d
    @MariaMartin-q8d Месяц назад

    Williams Margaret White Jeffrey Garcia Thomas

  • @KTWElectrical
    @KTWElectrical 2 года назад

    Not another EV install 😩

  • @garethfraser5211
    @garethfraser5211 2 года назад

    Meggers are terrible, had one it went faulty on no trip two wire test, sent back then it happened again. Not worth the money.

  • @robbmerrett5561
    @robbmerrett5561 2 года назад

    Another 11 minute video….
    Rip artisan the videos aren’t what they used to be!

  • @ZeldaMaster500
    @ZeldaMaster500 2 года назад

    why are those voltage testers so massive? lol looks like its 100 years old

    • @Matt-td9wx
      @Matt-td9wx 2 года назад +2

      You on about the megger ? Because it tests way more stuff than voltage that’s why 😂

    • @lewis94uk
      @lewis94uk 2 года назад +3

      @@Matt-td9wx probably American where the only testing they do is a bang test

    • @Matt-td9wx
      @Matt-td9wx 2 года назад

      @@lewis94uk 😂😂😂😂

    • @ZeldaMaster500
      @ZeldaMaster500 2 года назад

      @@Matt-td9wx mine does everything that does, yet can fit in my tool bag, that thing has an archaic design

    • @ZeldaMaster500
      @ZeldaMaster500 2 года назад

      @@lewis94uk go back to crimping your communication lines, leave the big boy stuff that powers your entire society to me