Crown Xavier 5.6kW: Solar Install Guide (Longi 580W) || Crown inverter Setting to Reduce Bill
HTML-код
- Опубликовано: 21 окт 2024
- Slash your electricity bills! This comprehensive video guides you through the ENTIRE installation process of the Crown Xavier 5.6kW Hybrid Inverter, including setting it up for maximum solar energy utilization. Learn how to:
Install PV Array: We'll walk you step-by-step through installing your Longi LR5-72HTH-580M solar panels (or similar models).
Unlock Hidden Features: Discover how to enable and configure the latest dual output option for ultimate control.
Optimize Settings: We'll show you the best settings for maximizing solar power generation and reducing your dependence on the grid.
User Battery Setup: Master user battery configuration for efficient energy storage.
Prioritize Solar First: Learn how to prioritize solar power usage before relying on the grid.
Ditch Manual Grid Switching: Eliminate the need for manual grid switching (On/Off Wapda).
Set DC Cut-Off Voltage: Ensure the safety of your system with proper DC cut-off voltage settings.
Maximize Panel Efficiency: Unlock the full potential of your solar panels with optimized configurations.
This video is perfect for homeowners and installers looking to:
Install and configure the Crown Xavier 5.6kW Hybrid Inverter
Maximize solar energy production
Reduce electricity bills
Gain in-depth knowledge of advanced settings
Don't waste money on your electricity bill! Watch now and start saving with solar power!
#Tags: Crown Xavier 5.6kw, Solar Inverter Installation, Longi Solar Panels, Dual Output Inverter, Maximize Solar Power, Reduce Electricity Bill, Hybrid Inverter Settings, Grid-Tie Solar System, DIY Solar Power, Solar Energy for Home
Related Keywords: Crown Xavier Inverter, Solar Panel Installation, Off-Grid Solar System, Battery Backup System, Solar Power for Beginners, Renewable Energy, Sustainable Living .
Welcome to the comprehensive guide on setting up your Crown Xavier 5.6kW Hybrid Inverter for optimal solar energy utilization and reduced utility bills! In this detailed video, we delve into every aspect of installation, settings, and key points to ensure you harness the full potential of your solar system.
Key Points Covered:
Step-by-step installation process, including PV array setup with Longi LR5-72HTH-580M 580W panels.
Detailed explanation of the Crown Xavier 5.6kW Hybrid Inverter's features and settings, including dual output options for maximum efficiency.
How to access and utilize the owner's manual for seamless setup and configuration.
Enabling and setting up dual output functionality, the latest innovation in hybrid inverters.
Optimizing battery usage with user-defined settings and maximizing solar panel utilization.
Setting solar priority to minimize reliance on the grid and reduce utility bills.
Manual override for switching between solar and grid power as needed.
Adjusting DC cutoff voltage for battery protection and longevity.
By following these instructions, you'll unlock the full potential of your Crown Xavier 5.6kW Hybrid Inverter, ensuring maximum efficiency and savings on your utility bills. Don't miss out on this essential guide to solar energy optimization!
#CrownXavier #HybridInverter #SolarEnergy #InstallationGuide #SolarPanelSetup #UtilityBillSavings #DualOutputInverter #SolarPriority #BatteryOptimization #RenewableEnergy #LongiLR572HTH580M #SolarPowerTutorial #GreenEnergy #OffGridLiving #EnergyEfficiency
8 plates ke sath maximum kitne Ampere generate kr rha ye bcz mera 17 se above nhi jata
Sir abee inveter chexk kia same version sir e ju batteries ka percentage show hu rahy haii Ye full haii Kunka Hamna 6 months 0ehly lagaya tha Aby tak Band nahii hua tha day and night in tha Kal band hua tha es liya ...Sir e batteries Kia reading dety haii 100 75 50 25 e reading correct hai
Without battery kn c setting bhtr hai SUB ya SBU?
@@awaisnaz6439 SUB
Time base py ap ny guide nhi kia L2 ka
Plz wo bata dy
Agar wapda pa shering ki gi tu wapda ka bill ata ha
Wiring ka thora guide kr dy k jo high load hy L2 us k liye alag se wire dalni pary gii jo jo high load ham ny chlana or dono wires phase or netrul ???ya netral l1 or l2 comen kr dy just phase wire dal ly ?
Ager aap ny high load chlna Ac. Ic ky lia koi extra wire dalny ki zarut nhi hai jo normal conecctions ic pee chl jae ga
sir es ka grid feed standard kaisae set krae?
Sir mery inveter me L2 lode on hony se system off ho jata ha Low lode b sath
We are going to install the same system
Ots dual output system you can use backup and to feed extra energy to WAPDA at the same time.
Wapda shearing kaha Sy off hota Hy ?
Assalamualaikum Bhai
Plz reply koi asi setting hai ka agar over load hoke inverter trip Kara TU wo khud hi restart hogaya. Aur hamara "crown Xavier II 3.6kw" inverter 30% solar aur 70% k electric use karta hai TU yeh ratio change kar sakta Hain ya asi koi setting hai ka wo phela solar jitna w de sakta hai de aur bad me k electric sa bhijli la
#23 overload bypass enable kerdin.
23 no setting mian.
#16 main OSO ya CSO kerdin. .
#02 main meximum charging current 60A kedin.
#11 main utility charging current 10A ya issa b kam krdin.
Without batteries SUB mode chalta ha ya ni i sir
yes...! but with limitation of *vm3 modle* .see this video to understand completely . ruclips.net/video/eISLReNdZaU/видео.html
Hamara same model ha crown5.6kw
Lakin SUB mode par bi wo wadpa sa share la raha ha or Ghar ka load sirf 3fans and 3 lights Hain or hamara panels longi 580W 10 panels hain
L2 py load 0 ho jata hai fix 4:50pm py.. AC off ho jaty hai
Is m. Koi timing hoti hai kia?
Same what is the problem
Sir mery pas highi lode per inveter off ho jata ha kya problem ho sakta ha plz guide kry
@@MuhammadIntizar-gz3ln bro booklet m setting hai waha sy inverter ki setting kry..
Meri prob solve ho gye hai
L2 ka time ksy change kry gy? Plz guide 🙏
60 no and 61
Iska software kaisay update krein... Meray inverter ka firmware version 11 hai... Apki video me 12 hai
Information about updating the firmware for a Crown Xavier 5.6 kW inverter isn't readily available online. Here are some steps you can take to find the official instructions:
1. **Check the Crown Website:** Visit the Crown website ([crownmicroglobal.com/](crownmicroglobal.com/)) and navigate to the support section. Look for a downloads page specifically for the Xavier 5.6 kW inverter. If there's a firmware update available, it might be listed there along with instructions.
2. **Contact Crown Support:** Since the information isn't easily found online, contacting Crown's support directly is your best option. Look for a contact form or phone number on their website and inquire about firmware updates for the Xavier 5.6 kW inverter.
**Important Safety Precautions:**
* **Manufacturer's Instructions:** Before attempting any firmware update, prioritize following the official instructions provided by Crown. Modifying firmware without proper guidance can cause malfunctions or damage your inverter.
* **Qualified Personnel:** If the update process seems complex or requires specific tools, consider consulting a qualified solar technician to perform the update for you.
I hope this helps!
Crown Xavier
63 ku 51 pa rakha hy
60 ku 50 pa rakha hy
38 = Net metering on hy .
Pehly jb light chali jati thi rat k time tu fridge or ac off hujati thi ab nhe hutay . Rat ku ot ker off kerna muskhel huta hy
Is model me net metering hai?
@@MUHAMMADYOUSAF-br8nt yes xavier ma hy
Can this system work without batteries
Yes
Okk thanks AC chalaina ka liya din din mae kitni minimum kitni plates required hain
@@fahadjamil5332 dc inverter ac ha to 4 pannels lagga lain. 1200-1500 watt tak maximum consume kerta but you have to put 4 pannels to full fill losess during conversation.
Bhai battery sarif solar charge karye wapda nahi karye aaysi koi setting ha???
#16 select "OSO"
@@moonelectrician1992 ❣️❣️❣️❣️
Bhai may battey kitny amp per charge karo 5.6kw crown ki marye pass or may nay 150mp ki battery lagyi hui ha AGS ki 4 danye kindly reply me
Kindly me reply me
Bhai may battey kitny amp per charge karo 5.6kw crown ki marye pass or may nay 150mp ki battery lagyi hui ha AGS ki 4 danye kindly reply me
How to stop its beeps in the morning and evening
In program #22
Set value to "AOf"
Beep while primary source is intrupted .
Ic beep ko off nhi kare goood things hai
Bhai isko 6000w per ek hi sting banaa sakte hain Koi masala To Nahin Haif
No problem
Bhai with out battery kesa work krta hy
allready answered . see the comments
Bhai wifi module ki setting details ma btaden ku k mane install kya h lkin app ma proper values show ni ho rahi hain
Contact no deden take issue share karun apko
Same system install kya hua ha mane one year pehle se bill kafi kam hua h low load maximum cuttoff h mera utility se. Isme mane out1 pe heavy load or out2 pe low load roha hua h kya ye thek ha ya change karun?
Reply
Ager apka havey load pahla off hotta to ok ha. !
Meny gr lgya ye system pehly ups ki wiring b ni huwi ab smart load or high load ko kesy manage kro alag se wire dalo ??or single ya double means phaseor netrul b ye kindly bta dy
Single wire ki wiring kerlain. Two ki kerskta hain to zadda better ha.
Ups ki wiring light load pa set kerlin baqi havey load pa.
Or agger AC wagara or moter hevey load DP main ayee ha to usko join kerka havey load bnaa lain baqqi sab light load
@@moonelectrician1992 ac lga huwa hy pehly normal wiring huwi ups ki b wiring ki huwi ab yehi samj ni a rha k alag se wiring kro to netrul ki b kro wo khercha boht huga fosra open hugii bori lgy gii agr single wire se kr lo system chly ga or havy l liye mehngii wire ki jaga light load k liye choti wire kr lo wo thk hy?
@@moonelectrician1992 ac lga huwa hy pehly normal wiring huwi ups ki b wiring ki huwi ab yehi samj ni a rha k alag se wiring kro to netrul ki b kro wo khercha boht huga fosra open hugii bori lgy gii agr single wire se kr lo system chly ga or havy l liye mehngii wire ki jaga light load k liye choti wire kr lo wo thk hy?
@@toseefhaider985 chalaga single wire s
@@moonelectrician1992 single wire dalni pary gii alag se ???....or is se k elwa koi hal hu ?
Apne bataya nahi k Solar charging kitni Ampare rakni hy ? Aur utility se minimum kitni charging rakni hy
Solar charging maximum rakh lain. Kunka jitna pannel hain utni hi ayegi. Or utility 20,30amp rakhin.
Yrr ye inverter bekar h wapda on ho to solar ko chor kr wapda use krna shru kr dyta h. SUB Mode select h
Sath joint box Lago wapda off kardo day time . . Night time WAPDA on krdo.
@moonelectrician1992 Bro aysa he kr rhy hain aj kal to. 1 bandy ki duty lgae hue h ky subha wapda ka breaker off krna h aur sham ko on krna h. Aur jb tang aaa jaty hain tb SBU mode with 24.5v back to utility.
Asa koi inverter btaeen jo real time sharing kry.
App is proble ko solve kerskta hoo.
#01 main SBU select krro.
Or
#16 main "OSO"
Istrah sa solve kerskta hoo.
Sir mene solar lgwaya hai ye wala lekin bar bar trip ker raha hai , kindly apna mobile no send kran
Kia fault code aa raha ha. Uski setting main masla hoga.
Same hear bro hamary sath bhi yahi problm hy
+923034581608
Boss g apka mobile numbr mill saktaa hy
For installation , online setting and visiting contact on number giving in description.
Charge's will be apply.
Kindly reply me
Yes brother. Tell me how can i help you. ?
@@moonelectrician1992 bhai SBU theek ya SUB is may kon sa therk ha 5.6kw
SBU main apko charging breaker on off ki tension khatam hojygi butt apka incase of light off bacup kam milaga . Light kam off hotti ha to ya setting thik ha.
Other wise SUB kerdin . Or day time wapda charging off kerdia krdin raat ko on kerdi.
Load Kay double neutral installed ki ha ?
Ok
@@moonelectrician1992 Kiya ok ?
Apka kia pocha dmaj ni ayee. Double neutral means what?
Sir mery inveter me L2 lode on hony se system off ho jata ha Low lode b sath
Contact ill be solve online. But paid.