Sir, please keep uploading this types of videos, I'm studying in third year of my BE electrical and I need this type of information a lot. Thank you for improving our knowledge❤️
Sir House wiring me agar ek 1.5Tr ka AC bhi start krte ho jo ki 1500W rated hota hai wo bhi inrush current jab leta hai to LED bulbs bhi kuch milliseconds ke lie din hojate hai kyuki unke driver module ka bhi ek input V range hai and P=IV ki wja se voltage me negative surge jo aata hai usi time LED lights bhi dim hojati hai.
Sir aapne mere kahne par video kab banaiye ga Jis tarah star connection me neutral hota hai thk usi tarah Delta me kya neutral hota hai ya nahi Plz make video in this topic and clear my doubt
I think it's not the voltage, its the power effecting the intensity or speed. When the loads are drawing their rated current, the drop in terminal voltage will reduce power fed to the component thereby effecting the performance of the components. Correct me if I am wrong.
Dhanyawad! aap ke video aur explanation ke liye. Mera ek doubt yeh hain ki gaon may aksar EB say sirf 180/190 volt hi atha hain. Us samay hamari electric meter jo Current consumption ko mapkar bill banathi hain, uskay ke upar kya asar honga? Kya yeh reading 230 volt kay waqt say kam honga ya jyada? Thanks.
sir series connection of load main current minus hona chahiye na.....agr LV 20 amp ka transformer hai...aur two loads connected hai....aur pehla load 18 amp consume kha rha hai...aur dusre ko bhi 18 amp chaiye...to second load ko to remaining 2amp hi milega na bcoz our transformer is having 20 amp capacity?... kindly explain
Hamare area mein low voltage hamesha hi rehta hai bich bich me itna low ho jata hai ki electric meter v on nhi ho pata hai lekin fan itna slow ki usse acha app fan ko band hi kar doge
Sir_Plss Rplyyy..🙏 Mera ek sawal hai >_ Agar water geyser On karne par Power Down ho raha ho to kya uske Liye Direct separately 2mm/2.5mm Wire dene se kuch fark padenga..?? Kya Power Down hona band ho jayenga..?? Ya fir On karte hi Sab Low Voltage par chalne lagengaa..??
Ac voltage have cycle in which polarity changes due to this motor will rotate in both directions to avoid this capacitor is joined to motor when during ac half positive cycle the capacitor charges and during next ac negative half cycle the capacitor discharges and oppose this neagative half cycles
हमारे फार्म में थ्री फेज ट्रान्सफोर्मर से आता है जिसमें न्यूट्रल नहीं है उससे 5 एच पी कुएं पर लगीं है लेकिन न्युट्रल न होने पर ग्रांडीर कटर धीमी गति से चलता है हालांकि अर्थिंग लगाने पर भी । कृपया स्टिंग बढ़ाने का उपाय बताए
Parallel main kaise voltage drop ho raha hai.... wahi toh explain ki hai pure video main, aur V=IR se line drop kya hai woh samjhaya...aur .. Single conductor ka inductance ka value kafi kam hota hai, phir bhi le toh wali bat hai V=I.XL (line drop he horaha )
My geyser takes 13A continuous current then why my LED lamp gets dim for a little time? If reason explained by you is right then LED lamp should get dim as long as my geyser is in ON condition.
Sir muje ek chiz samaj nhi aa rahi ke uska solution kaise kare. Actually pichle 3 saal se humari light ya to dim ho jati hai ya chali jati hai to electricity board me complain ki to pta chala ke humare area ka jo phase hai usme load zyada ho jane ki wja se aisa hota to esa sirf humare ghar me nhi balki or bhi 6-7 ghar hai par humare pas na ac hai na koi esi badi appliances, hm sirf do fan, ek fridge or ek led tv or ek led light use krte hai bs or humare ghar inventer bhi nhi hai to garmiyon me bhot pareshani hoti hai. To hm ye phase change kaise karwaye? Kal rat se hmari light dim hai ya chali jati hai or electricity board pichle 3 saal se ye fix nhi kar pa raha or humara phase same ka same rehta hai jabki baki do phases me light proper ati hai. Baki 6-7 gharo ko frk nhi padta isse kyuki unke ghar inverters hai to Please ap iska hal karde koi?
Company vagaira mein voltage drop kyon nahin hota hai kyunki usmein Kitna ampier ka load Laga rahata hai uske hisab se to voltage bahut kam ho jana chahie Aisa kyon nahin hota Jara bataenge sar
Aapki bhashha saral nahin hai, samanya logon ki samajh we Babar hai. Samjhane ki kala aisi honi chahiye ki anparh v engineer ban jaye, aap medal engineer on ko parhha rage hain, kam baat kijiye par wo dimag mein this jaye, kyonki kam large like log v inhen dekhte gain. Jaise khan sir samjhate hain.
Sir, please keep uploading this types of videos, I'm studying in third year of my BE electrical and I need this type of information a lot. Thank you for improving our knowledge❤️
Sure 😊❤❤
@@NOMORErattamaar parellel load me voltage same and current sabke liye alag alag hota hai.
to dim hone ka karan ye sab nhi hai
@@abhishekkumar-mm6bt apna answer dijiye
You are beyond any IITian......❤️
Good videos. Kindly keep it on. Useful for students
Sir House wiring me agar ek 1.5Tr ka AC bhi start krte ho jo ki 1500W rated hota hai wo bhi inrush current jab leta hai to LED bulbs bhi kuch milliseconds ke lie din hojate hai kyuki unke driver module ka bhi ek input V range hai and P=IV ki wja se voltage me negative surge jo aata hai usi time LED lights bhi dim hojati hai.
Sir very good explanation thanks,,💐💐
Seeing everyday the same but few only knows the exact reason behind it. As usual very informative.
☺️😇❤️❤️❤️
Great concepts sir
Sir bahot badhiya information di apne...please ek vidoe 3 phase motor ka RCCB/ELCB ke connection par ek video banaiye
Lovely 👍👍👍👍👍
Great information....
Thanks for the information bhaiya❤️😊
😇😇❤❤❤
Appreciates your efforts
Nice explanation
Brooo you Are Great
Nice
Voltage drop is natural fenomina
Due to AVR reaponse time
Thanks you sir
Sir , May we please have a dedicated video on the working of AVR (Automatic Voltage Regulator) in Alternator ?
Very useful knowledgeable video , really
Thank you 😊❤
thank you🙏❤❤
Good information
Bahut mazedar tha
😁😁❤
Sir aapne mere kahne par video kab banaiye ga
Jis tarah star connection me neutral hota hai thk usi tarah Delta me kya neutral hota hai ya nahi
Plz make video in this topic and clear my doubt
I think it's not the voltage, its the power effecting the intensity or speed. When the loads are drawing their rated current, the drop in terminal voltage will reduce power fed to the component thereby effecting the performance of the components.
Correct me if I am wrong.
Dhanyawad! aap ke video aur explanation ke liye. Mera ek doubt yeh hain ki gaon may aksar EB say sirf 180/190 volt hi atha hain. Us samay hamari electric meter jo Current consumption ko mapkar bill banathi hain, uskay ke upar kya asar honga? Kya yeh reading 230 volt kay waqt say kam honga ya jyada?
Thanks.
Voltage 180/190 honay par meter billing kamm ho jaeygi, lakin apkay gharon main lagay motors kharab ho saktay hain
Parallel series ke upar ek video banayiyee
Good👍👍
Please make video on Why Generator speed thus frequency decreases with increasing load ???
Thnx guru ji
Sir last me video ke thoda short me sumarise krke btaya kijiye ki ise interview me kaise explain kare... 🙏🙏🙏
Thankyou sir 🥳
Right information
😊❤
Super video
🔝 EEE channel
Aap bahut ache se samjhate ho.. lekin aap bahut teji se bol rahe h
Voltage kaise badaye kya equipment joint karna padya
Tar ka length agar jyada Raha to ous mein bhi voltage drop hoga kya drop hoga to kitna drop hoga ek se do voltage
sir series connection of load main current minus hona chahiye na.....agr LV 20 amp ka transformer hai...aur two loads connected hai....aur pehla load 18 amp consume kha rha hai...aur dusre ko bhi 18 amp chaiye...to second load ko to remaining 2amp hi milega na
bcoz our transformer is having 20 amp capacity?... kindly explain
Aise me Steblizer dene se problem thik hoga kya
Hamare area mein low voltage hamesha hi rehta hai bich bich me itna low ho jata hai ki electric meter v on nhi ho pata hai lekin fan itna slow ki usse acha app fan ko band hi kar doge
Total power is constant in circuit If current draw from circuit is increase voltage will decrease.... is that explanation is true..
No
Thx.
Kuch samay k liye ho to sahi h pr continue time Tak yahi situation rahta h
Very halful video sir 🙏🙏🙏🙏🙏
Sir I want to ask a question when load is switched then drop in line is increased so dimming of light is noticed continuously or small time
Sir_Plss Rplyyy..🙏
Mera ek sawal hai
>_ Agar water geyser On karne par Power Down ho raha ho to kya uske Liye Direct separately 2mm/2.5mm Wire dene se kuch fark padenga..??
Kya Power Down hona band ho jayenga..??
Ya fir On karte hi Sab Low Voltage par chalne lagengaa..??
Bhai mera v same problem hai geyser on krte h ghar p voltage drop hota hai . Solution mili kya
What is the solution in these situation
Capacitor in motor reduces voltage drop?
Ac voltage have cycle in which polarity changes due to this motor will rotate in both directions to avoid this capacitor is joined to motor when during ac half positive cycle the capacitor charges and during next ac negative half cycle the capacitor discharges and oppose this neagative half cycles
So it reduces negative cycles
Sir 5hp ka connection hai 10 hp.motor chalayegay to keya hoga ?
👍🏻
Iska mtlb agr hum load ko lagate jaye to Kx time baad last k load tk to voltage pahuchegi ni or wo kaam ni krega????
हमारे फार्म में थ्री फेज ट्रान्सफोर्मर से आता है जिसमें न्यूट्रल नहीं है उससे 5 एच पी कुएं पर लगीं है लेकिन न्युट्रल न होने पर ग्रांडीर कटर धीमी गति से चलता है हालांकि अर्थिंग लगाने पर भी । कृपया स्टिंग बढ़ाने का उपाय बताए
Jese industry me bahut sara load hota hai iss hisab se to 1 time par sara voltage drop ho jayga aakhiri load tak pahuchte
Thank you sir
Sir mere ghar me inverter pe fan speed se phirta hai but main line pe slow kyu hota hai
👍👍.
Bt we can use v=ir it's not pure resistance for home or parallel me vlg drop kese.. Voto series me hota hai na?
Parallel main kaise voltage drop ho raha hai.... wahi toh explain ki hai pure video main, aur V=IR se line drop kya hai woh samjhaya...aur
.. Single conductor ka inductance ka value kafi kam hota hai, phir bhi le toh wali bat hai V=I.XL (line drop he horaha )
sir ,the problem which you mentioned here whaat is the solutionn of this
Sir motor ki efficiency kab high hoti hai aur kab low hoti hai aur power factor bhi plz sir us per video banao sir plz plz sir🙏☺️
Nice suggestion, sure i will make 😇❤
Sir 2 hp single phase moter chalane pr voltage drop hota hein upto 100 & remains constant , not increasing automatically.What's the solution ?
Sir voltage pe depend krta h ki current pe please
Voltage par depend krta hai, aur voltage current par agar resistance constant hai...V=IR
My geyser takes 13A continuous current then why my LED lamp gets dim for a little time? If reason explained by you is right then LED lamp should get dim as long as my geyser is in ON condition.
Sir why transformer ka rating in kva and motor ka kW why sir .Sir please replay.
Bahut jald video aayegi bhai
Sir muje ek chiz samaj nhi aa rahi ke uska solution kaise kare. Actually pichle 3 saal se humari light ya to dim ho jati hai ya chali jati hai to electricity board me complain ki to pta chala ke humare area ka jo phase hai usme load zyada ho jane ki wja se aisa hota to esa sirf humare ghar me nhi balki or bhi 6-7 ghar hai par humare pas na ac hai na koi esi badi appliances, hm sirf do fan, ek fridge or ek led tv or ek led light use krte hai bs or humare ghar inventer bhi nhi hai to garmiyon me bhot pareshani hoti hai. To hm ye phase change kaise karwaye?
Kal rat se hmari light dim hai ya chali jati hai or electricity board pichle 3 saal se ye fix nhi kar pa raha or humara phase same ka same rehta hai jabki baki do phases me light proper ati hai. Baki 6-7 gharo ko frk nhi padta isse kyuki unke ghar inverters hai to Please ap iska hal karde koi?
Why this effect only on light not another appliances
हेलो सर उसे थीक केसे करे?
Nice explanation but how to solve this problem??
Least resistance wire used
Sir ap ka bat to 100% h but sir voltage to multi meter me voltage 230v dikhata h
Nhi aap check kijiyega, value change hota hua dikhe ga....specially switching ke waqt.
AC and DC
Video acche hai subscriber kam hai share karo bhai
Parallel me toh voltage same hi hota hai toh fir aisa kaiss
Company vagaira mein voltage drop kyon nahin hota hai kyunki usmein Kitna ampier ka load Laga rahata hai uske hisab se to voltage bahut kam ho jana chahie Aisa kyon nahin hota Jara bataenge sar
😍😍😍😍😍
Ye last me train itni fast kyu hogai😂
Bhai ji zoology bsc third
interview language kya bolna h
Ho rha hai bhai yea sala ac start krte hi ho rha hai
Aapki bhashha saral nahin hai, samanya logon ki samajh we Babar hai. Samjhane ki kala aisi honi chahiye ki anparh v engineer ban jaye, aap medal engineer on ko parhha rage hain, kam baat kijiye par wo dimag mein this jaye, kyonki kam large like log v inhen dekhte gain. Jaise khan sir samjhate hain.
Sir mere ghar same problems hai kya wiring change Kar ni chahiye