Can Capacitor reduce our electricity bill ? Power saver device Real or fake
HTML-код
- Опубликовано: 6 ноя 2022
- Can Capacitor reduce our electricity bill ? | Capacitor Connection in our Home
In this video, I have explained about what will happen if we connect a capacitor with the main power supply ? Can electricity bill reduce by connecting power factor capacitor with power supply ?
Thank You
Arun Gupta
Electricaltechnician02@gmail.com
══════⊹⊱≼≽⊰⊹═════════⊹⊱≼≽⊰⊹══════
TELEGRAM :
telegram.dog/ElectricalTechnic...
FACEBOOK : @electricaltechnical
/ electricaltechnical
INSTAGRAM : @electricaltechnician02
/ electricaltechnician02
2nd Channel @Electrical Wiring School
/ electricalwiringschool
Electrical Technician English Channel @The electrical guy
/ @theelectricalguy
Shorts Video @Electrical technician Shorts
/ @electricaltechnician02
══════⊹⊱≼≽⊰⊹═════════⊹⊱≼≽⊰⊹══════
My gadgets for RUclips 📺
Camera 📸 For video Recording
amzn.to/3z3W9XM
Mic 🎤 For Sound Recording
amzn.to/3kpUyaK
Tripod Stand
amzn.to/3BajZmn
Overhead Stand For Recording
amzn.to/3z1rzhm
══════⊹⊱≼≽⊰⊹═════════⊹⊱≼≽⊰⊹══════
Electrical Device For your Home which you Should Have
Wi-Fi Control Smart Plug top
amzn.to/3dAZrJA
amzn.to/3hcO6Sr
Multimeter for electrician
best - amzn.to/3w7Vbry
Low Price - amzn.to/3wfF1MC
Water Level Controller
Single Tank - amzn.to/3xdcrwY
Double Tank - amzn.to/2UnvJAX
Motor Starter
2 HP Motor Starter - amzn.to/366AlhL
2 HP Motor Starter - amzn.to/3xhVtxw
Toolkit For Electrician
amzn.to/3AmK1T5
══════⊹⊱≼≽⊰⊹═════════⊹⊱≼≽⊰⊹══════
Related video for you
P.F Capacitor Connection
• Why Resistor Block is ...
How to check capacitor Value by multimeter
• Capacitor को कैसे Mult...
Submersible pump Starter
• Capacitor को कैसे Mult...
Capacitor Size for Motor
• Single phase motor Sta...
#saveelectricity #capacitor #electrical #electricalengineering
आपने कैपेसिटर के बारे मे बहुत अच्छे से समझाया कि इससे बिजली बिल कम नहीं होता। धन्यवाद
Very nice good explanation
Thank you very much
Bahut achhi jankari di hai aapne ....Good information 😍😍😍😍👌🏻👌🏻👌🏻👌🏻
Excellent, very informative and practical video session, keep it up and all the best...
धन्यवाद सर,बहुत ही अच्छे तरीके से समझाया है
Salam
Mind blowing behtareen procedure k Sath brief Kya I appreciate your efforts
Very nice video. Video of the Decade👍💗💗💗❤️❤️
This is the exact science that many electrical engineers don't even try to understand.
Thank you dear.
Well define and well explain.great job
Useful🇮🇳 information TQ🙏🇮🇳
Very nice sir....pura acha samaj me aaya thank you
Nice explanation but everybody can not understand this electrical theory. But they must understand and try this method. My branch is electrical and I am using this since 1994.
Sir, what is value of the capacitor being used in this video?
Good knowledgeable good explain sir
Good information thank you🙏
sir aap plc programing or connection par ek video banaye aap ki video se bahut jankari millti hai
thanks for informative videos 👍
Hi , I like your video. Thank
Osm ❤️❤️ way that you explain 👍👍
यह तो वही बात हो गई गंगाधर ही शक्तिमान है 😂👍
😂😂😂😂
Hahahaha
Jab PF 0.9 ho jay to per current malom karky Power dobara malom karlo per pata chaly ga.... second step teek nahi hai
Its right, will you details herein who much & whats specification of capacitor is required against kilowatt load of circuit, will appreciate you thanks.
13 MFD FOR MOVING PF 0.75 TO 0.99 FOR LOAD OF 1500 W @ 50HZ
Yes, you are correct. Capacitor only increase the PF value, it doesn't mean that it save the electricity bill. 💡
Reducing Current ( ie improving power factor) will reduce the copper loss. So there must be some reduction in power consumption.
If you fix the capacitor it will improve the power factor and it will increase some of power consumption. Because the capacitor will take power for working .
Very nicely explained for novice students.
Effort praise worthy..
Domestic bills are based on KWH not KWAH so capacitor only increase power factor without reducing bill.
Roght bro.
Ok ,thaks to video, Good job
Soft starter control warning ka video banaye sir ji
Thanks for information.
I liked ur idea sir.
Thanku sir 🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏
Thanks we also working nd making videos on electrical devices thanks
Real power can not be changed only reactive power changed . So there will be no significant change of KWH measure if we connect capacitor or not, only KVARH changed. When pf improved or approaches 1 then current decreases and when pf decreases then current increases . So power remains same.
In the modern era, capacitors have already been installed in all electricity devices
Nice information
Sir bhut achha jankari
Excellent...
Good job....
Resistive load ka PF 1 hi rehta he,
Induction load jaise motor pump mixi etc laga ne se PF 0.6-0.8 Tak variation ho jata he. Us waqt Capacitor ka use hota he
Kitna m f ka capacitor lagaye
@@crazyfun4870 Depends upon your load
Agr 5 km ka load ho to
💞💞🙏sirji fan me use hota h🙏💞💞
Very good sir ji
Very good explanation sir ji…. Good job 👍🏻
Ya theory to Shunt Capacitor k h ,jismai reactive power ko load side mai badhane k liya use kiya jata h aur from power system hum load ko inductive nature aur reactive power consuming k hi manta iska liya humlog substation m Static Voltage regulator (SVC) jo Combination h Capacitor and inductor with thyristor switching k use karte h na ki shunt capacitor k kuki Shunt capacitor use reactive power ko badhane k liya hota h par kabhi kabhi reactive power ko ghatana bhi par h kuki Summer aur Winter k load alag alag hota h , isliya iska use na kare.
Now a days there is hardly any inductive load except for ceiling fans. These too are being changing these days with use of BLDC motors.
and what would u say about the submergesible pumps for water tank refilling in our house? How can u change that inductive load 😅😅
Tq
Sir kitni value ka capacitor lgana hai gar k lye?
👍
All home appliances are run on 230v but when you supply more than or less than the energy meter will run fast or Slow Because energy Meter base Voltage is 230v.
So either install Stabilizer or right value mfd capacitor.
Voltage at the Energy Meter potential terminals that matters not the voltage at load point., Current flowing through current terminals and power factor between current and voltage vectors at metering terminals matters. Installation of stabiliser after meter affects voltage at load , meter measures the input power of the stabiliser.
I appreciate your effort for making the video but just want to clear one thing here (I hope you would be aware of that sometimes we mistook between two, so its fine) that you switched between the 2 i. e. Leading power factor is the one in which current leads the voltage(not the voltage leads the current as you said in the video) and vice versa.
Hope the viewers would not be confused.
Yes you are right
@@asadrafik7547
Yes you are crt
@@ashishbarde1380 yh6k6kh y
@@asadrafik7547 .m k
Nice video 😍😍😍😍❤❤❤❤❤❤❤
good
13 MFD FOR MOVING PF 0.75 TO 0.99 FOR LOAD OF 1500 W @ 50HZ WITH PROPER FUSE IN SERIES
Singal fase me kitne ka capcitor lagaye
Sir, ghar ki liye kitna mfd ka capacitor lagega
13 MFD FOR MOVING PF 0.75 TO 0.99 FOR LOAD OF 1500 W @ 50HZ
Nice explanation, so konsa device hai bill kam ayegi please reply karo humara bill jyada ata hai.... Please reply I m waiting
👍👌❤️
Nice video
Ketna lod par ketneka capacitor lagega?formula keya hyay?
Sir electric bill how to consume please reply
The summery of this video starts from 09:05
❣️
What type of capacitor will weneed
What type of Capacitor do we have to buy?
How many Power copociter use and what load telling me about it
👍👍👍👍👍
I inters this work
Sir capacitor ko series me connect karenge ya parrellal me
Agar current kam hoga to kya device chal payega jitna jarurat hoga
Inductive load me to voltage आगे रहता है उसके बाद करंट रहता है
कैपेसिटर लोड में करंट आगे रहता है और वोल्टेज पीछे रहता है
If we directly connect capacitor one side to Phase and one side to neutral (means if we directly connect it to the socket), will it blast or not. People says do not connect capacitor more than few seconds other wise it will blast. Please reply.
Capacitor is connected between phase supply and neutral supply always it will not blast
But if the capacitor is faulty it will surely
Capacitor should be of more mfd compared to connected load... If connected load will increase it obviously will blast
Sir voltage current se aage hai to lagging power Factor hoga and current voltage se aage hai to leading power Factor hoga
Mera ek saval hai ki kitna maykro fared ka capacitor lagana padega
Meter me How much metro favorite capacity uf is used in the meter?
How much MFD capacitor need connect with singal phge ,pl.
what value of capacitor should be used for this.......
13 MFD FOR MOVING PF 0.75 TO 0.99 FOR LOAD OF 1500 W @ 50HZ
Kon sa capacitor use Karu,uf aur vol bataiye
For 2 bhk apartment flat what rating capacitor is connected
Sir ji capaciter value calculation??
But when you trouble shoot your line .wait until capacitor fully discharged.
Which Capacitor nead Sir
If you are right , need to know what will be capacity of capacitor as in 3 phase we calculate 2.5 hp need 1 KVAR capacitor.
How to calculate for 1 phase.
13 MFD FOR MOVING PF 0.75 TO 0.99 FOR LOAD OF 1500 W @ 50HZ
Stebilizer ko meter se pahle or baad me connect kare
How much micro farad capacitor use
No . Capacitor can't reduce electrycity Bill. In every electrical equipments there are capacitor. If it is dose the electricity bill reduce automatically.
If iam using 4000watt in one hour then which one capacitor can work .
Sir ji kya fayda jab minimum fixed unit abse 120unit hi ayega.aap 120 unit se Kom jalanese v 120 unit to ayega Jo minimum 600 to ho hi jayga
6:30 agar watt ki value pahele wala equation se dal doge to
Kwh(unit) to end me same hi ayega🙄
Bro ghr ki liya kitna ki capister ki lagya jis sa bijle ki bill kise kam hia
Capecotor motor fan iski speed ka kaam karte hai.
Power kam nahi karte
Power factor electricity aate wakt theek ana chahiye . Ab uske liye hame penalty bharne ki kya jarurat
Sir aap sidhye hi bataye ki capactor lagane se voltage kam hota hai ya nhi ...
Kiya jo pan mein lagata hai ohi. Laga sakta hai kiya
ghar par p. f. 0.8 se upar hota hai ji
What will be the value of capacitor for household connection?
A nai pata hai inko live karke bato a nai batayenge ghar jalane ka naya and anokha method hai a
There will be no change in of electricity consumtion
Ek Ghar mein jahan 25 empier use ho rahe hain. Vahan kitni takat ka capacitor lagega?
Which capacitors need to use
Pf cap
Good bhae ok
Lagging leading concept aapne glt bataya h sir please correct @electrical technician
Super bro nnage kannada videos beku
सर मोटारसायकल C C me ओर ट्रॅक्टर HP मे नापा जाता है तो उनमे अंतर क्या होता हे
उदाहरण 150cc मोटारसायकल ओर
21hp का ट्रॅक्टर उनके इंजिन की ताकत मे
कितना अंतर होगा जवाब जरूर देना
मे वेट कार रहा हुं
Capasitor kitna number laganahe . capacitor 2.5
Many Atta chakki me 30HP ke motor lgai jo 30 amp laay rahi the or boht ziada heat ho rahi the phir many capacitor install kia to amp 20 ho gya or motor ab heat bhe ni hoti or load b ziada uthati hai
Capasiter value?