  • Find out how to wire RCDs in split consumer unit. More electrical tips and diagrams www.aboutelectricity.co.uk
    Like, subscribe and don't skip the ads :)
    Shopping list :
    ►Garage,shed consumer unit amzn.to/2onFD0K
    ►Split load consumer unit amzn.to/2pgGm7Z
    ►Schneider Electric MCB's amzn.to/2osH4tQ
    ►Schneider Electric RCD's amzn.to/2pgLFV1
    ►Schneider Electric RCBO's amzn.to/2o4iowy
    Disclaimer:
    I can't under any circumstances be held liable for any possible personal injury or material damage resulting from the use of this example.
  • НаукаНаука

Комментарии • 37

  • @AboutElectricity
    @AboutElectricity  6 лет назад +5

    Hi ! As always I am looking forward for any comments. Your feedback is important to me.

    • @msangwan7
      @msangwan7 6 лет назад +1

      AboutElectricity Thanks man really appreciate your work. Thanks again. I am based in London, Acton and now days working as plant engineer, you around?

    • @AboutElectricity
      @AboutElectricity  6 лет назад

      Nothing is guaranteed but I will think about it :). Are you talking about industrial machinery or other applications ?Send me some links with examples.

    • @AboutElectricity
      @AboutElectricity  6 лет назад

      I have some videos already ruclips.net/video/J0nCeEC-sCE/видео.html - simple motor starter, ruclips.net/video/UH_Yj7Arh4M/видео.html - motor forward-reverse. It's just how to write a program but it might be helpfull.

    • @smartcars_intelligentworld5469
      @smartcars_intelligentworld5469 5 лет назад

      AboutElectricity Hi why are the neutral bars (1and 2) separated from common neutral bar. why don't you use one common neutral bar for RCD1,2 N bar

    • @m101ist
      @m101ist 3 года назад

      @@smartcars_intelligentworld5469 No, they must be in order, don't mix the neutral wires. 🙄

  • @PJANGELES30
    @PJANGELES30 7 месяцев назад +2

    excellent, first class clarity

  • @agbekoakakpo8897
    @agbekoakakpo8897 6 лет назад +4

    great job man, the best video ever showing into details how to wire consumer units

  • @rakselectric7390
    @rakselectric7390 6 лет назад +2

    This video shows very clearly how to wire a consumer unit good job and keep posting

  • @Rodzina
    @Rodzina 4 года назад +2

    Well done ! I was looking for that kind of video instruction. Step by step with comment -thanks for your time and presentation.

  • @carpgirls
    @carpgirls 4 года назад +2

    How about doing one with only one RCD and the variations you may discovery at jobs where there could by MCBs and RCBOs and RCD mixed on a board?
    Great video, clear simple and concise to follow 👍

  • @jamesgraham6947
    @jamesgraham6947 6 лет назад +1

    Excellent video. Very impressed. Just subscribed to your channel. My lad is an apprentice electrician and would find these videos very informative.

  • @swanthorn
    @swanthorn 3 года назад +1

    great lesson! thank you!

  • @zvonimirruzicic1944
    @zvonimirruzicic1944 3 года назад

    Great lesson :) Thank you.

  • @kc8130
    @kc8130 Год назад +1

    Clear and precise explanation 👌

  • @quocly4573
    @quocly4573 5 лет назад +2

    Hi, It is very nice and clear Video, Thanks. But please consider if you want to do it yourself cos there are more factors which affect like: cable size, capacity of the circuit. We can not afford to make mistake on a RCD.

  • @AntKardano
    @AntKardano 5 лет назад +2

    Hi, thank you for making this! Really helpful. One question tho.
    Does it matter which way you connect the input line to the MCB? I was always taught to connect the input line only from the top, but can you also do it like you did and connect the phase input from the bottom?
    Thanks

    • @AboutElectricity
      @AboutElectricity  5 лет назад

      jamir do you mean busbars at the bottom of the mcb's?

    • @AntKardano
      @AntKardano 5 лет назад

      yes, thanks for your reply.

    • @AboutElectricity
      @AboutElectricity  5 лет назад +1

      jamir there is no other option because live wire is going to the top of the RCD and then of the bottom it is linked with MCB's by busbar.Anyway,makes no odds to the MCB if its feed from top or bottom, it will still works.

  • @engzkurd
    @engzkurd 2 года назад

    Hi, Great video
    Could you please tell me witch drawing software you have used?

  • @1mannik
    @1mannik 5 лет назад +1

    Thank u

  • @taurusalmighty3071
    @taurusalmighty3071 4 года назад

    Nice illustration. Could the two 2P RCDs be replaced with a single 4P RCD?

    • @AboutElectricity
      @AboutElectricity  4 года назад +1

      Let me quote some regs "Regulation 531.3.2 is another ‘new’ regulation that is intended to aid designers make better design decisions. This supports the principles of Regulation 314.1 (17th and 18th editions) which requires every installation to be divided into the number of circuits required to avoid danger and hazards caused by unwanted tripping of RCDs - a single fault should not cause the loss of power to groups of circuits".

    • @taurusalmighty3071
      @taurusalmighty3071 4 года назад

      @@AboutElectricity Thanks

    • @m101ist
      @m101ist 3 года назад

      @@AboutElectricity That's a good idea, the split circuit,I like it. 🙄

  • @math-with-afshin
    @math-with-afshin 5 лет назад

    Hello Sir , initially really I'm very thankful of you for your very helpful video series , could you please answer these questions , about RCD and RCBO , it seems that RCBO is better than RCD because RCBO does somehow operation and in this way "save life of people" and also protect the devices such as TV and washing machines and so on , yes ?? So what is the difference between RCD and RCBO?? which one of them for home is better and most suitable ? each ones RCBO for TV and washing machine is needed separately ? each one should has which specifications/ amperage ? each RCBO can cover how many devices ? sorry a lot of questions !! I am contacting from Kiev in Ukraine and by answering my questions you will solve a lot of problems for me and at the same time it is a very big favor, Your fan , your supporter , Afshin Heydari

    • @AboutElectricity
      @AboutElectricity  5 лет назад +3

      Well RCBO is like RCD + MCCB. The problem with RCBO is when it trips you do not know if it is because of current leakage or short circuit.When using separate RCD and Mccb you know it straight away.

    • @math-with-afshin
      @math-with-afshin 5 лет назад

      @@AboutElectricity thanks a lot for your kind attention.

    • @alanmainwaring1830
      @alanmainwaring1830 9 месяцев назад

      RCBO's are great but they are very expensive. Easy to check overload switch off all power and measure resistance between active and neutral. Use definition of resistance to derive current. Or use a clamp current meter with power on.

  • @alanmainwaring1830
    @alanmainwaring1830 9 месяцев назад

    I am puzzled in the final step surely the main neutral bar needs a link to Earth or does it??

    • @AboutElectricity
      @AboutElectricity  9 месяцев назад

      No, you don't link neutral to he earth bar.

    • @alanmainwaring1830
      @alanmainwaring1830 9 месяцев назад +1

      Yes I realized that you guys in Britain have the outer sheaf of the incoming supply cable bonded to the main neutral
      of the supply which then goes to a local ground rod as well. This is not done in Australia the main neutral from suppy has to go to main neutral bar then is linked to Earth bar. I really like your diagram it is nice and clear.
      @@AboutElectricity

  • @claudiub2904
    @claudiub2904 6 лет назад

    Hi. Where is the important part, MEN?

  • @detrich9386
    @detrich9386 5 лет назад

    Only an idiot could switch the main neutral...

    • @AboutElectricity
      @AboutElectricity  5 лет назад +1

      Yes,we are all idiots