Transmission Lines | Stringing
HTML-код
- Опубликовано: 7 сен 2024
- Stringing- Paying out
More on:
Foundation- • Transmission Lines | F...
Rock Anchor Foundation - • Transmission Lines | R...
Erection- • Transmission Lines | T...
Under Ground Cable- • UNDERGROUND CABLE | La...
OPGW- • UNDERGROUND CABLE | La...
Pile Load Test- • Pile Load Test
Scaffolding- • Scaffolding
Erection- • Transmission Lines I T...
Stringing- • Transmission Lines | S...
Conductor Sagging- • Transmission Lines | C...
Tower Testing- • Transmission Lines | T...
GIS Termination- • UNDERGROUND CABLE | GI...
Shotcrete- • Shotcrete | Gunite | S...
Monopole Erection (Suspension)- • Video
Monopole Erection (Tension)- • Monopole Erection | Te...
Cable Installation- • Underground Cable
Subscribe:
/ pritamsingharoy
Enjoy Watching!
Link for other Transmission Line Work
Foundation- ruclips.net/video/W5G2TwDWSnU/видео.html
Erection- ruclips.net/video/vrDC-Dfnnhw/видео.html
Under Ground Cable- ruclips.net/video/armLWFEi8tk/видео.html
OPGW- ruclips.net/video/armLWFEi8tk/видео.html
Pile Load Test- ruclips.net/video/trnrUBUCXGo/видео.html
Scaffolding- ruclips.net/video/5wLxlq6JE40/видео.html
Erection- ruclips.net/video/C-QhkGbxryQ/видео.html
Conductor Sagging- ruclips.net/video/UsmXO7KNBlc/видео.html
Tower Testing- ruclips.net/video/m0LtgEh5JIc/видео.html
Hi thanks
hi pritam. love your videos. i'm kinda of noob in power line works :D. could you please explain to me how to determine maximum length of a pulling machine can handle based on pulling force capacity of the machine? thanks
I guess im asking the wrong place but does any of you know of a trick to log back into an instagram account..?
I was stupid forgot the account password. I love any help you can offer me
@Ibrahim Malcolm Instablaster :)
@Kristopher Nicolas I really appreciate your reply. I got to the site thru google and Im waiting for the hacking stuff atm.
Takes a while so I will reply here later with my results.
Hardworking Indian brothers 👏👏🤗💕
It couldn't be better explained. Thanks for sharing.
thanks for ur valuable feedback
Thanks for uploading this video. It is very helpful as it explains nearly whole process in details. It cleared all my doubts. Thank You once again🙏
You are most welcome
Good & Helpful for people working in Transmission Sector
Asalaam aliakum. Hey everyone thank you for the video and for detailing your video with instructions so others can learn from you. You are much appreciated!! And I especially loved how you added special editing features in your video!! You are so wonderful and awesome!! It made me feel love today so thank you very much!! May Almighty God bless, protect, forgive, and continue unconditionally loving you, your families, and all your loves ones, and us all!! (Bismill Allah).. have a blessed, safe, and loving day and thank you again..
Asalaam ✌️ peace
Loves you all!!
Using cut resistance gloves make much safer in cable pulling and sleeving
Very nice and good job informative Video.
Ram Yadav An Electrical Engineer
Ram Yadav ji I mush interested in this field please note my no 7507048097
I'm very glad I saw this video.
Thank you
Welcome
There are lots of video on Foundation, Erection, Stringing, OPGW, UG Cable.
Visit my page to grab more and pls share if you liked it
Foundation- ruclips.net/video/W5G2TwDWSnU/видео.html
Erection- ruclips.net/video/vrDC-Dfnnhw/видео.html
Under Ground Cable- ruclips.net/video/armLWFEi8tk/видео.html
OPGW- ruclips.net/video/armLWFEi8tk/видео.html
Pile Load Test- ruclips.net/video/trnrUBUCXGo/видео.html
Scaffolding- ruclips.net/video/5wLxlq6JE40/видео.html
Erection- ruclips.net/video/C-QhkGbxryQ/видео.html
Stringing- ruclips.net/video/4Lje07848bE/видео.html
Conductor Sagging- ruclips.net/video/UsmXO7KNBlc/видео.html
Tower Testing- ruclips.net/video/m0LtgEh5JIc/видео.html
good video. please share the videos of soil resisitivity measurement, TFR measurement, resistance of Midspan joint measurement.
Hard job and keep safety
Make sure a marking before aluminum tube lying (for both end of the conductor is equal jointing)
Great work
Though job salute to tata power
Good information
Good job my friend 👍
awesome knowledgeable vdo
Add More videos on Transmission line Towers I.e Type of Tower, Its erection etc
Sure.....
Nice video
good job
Thanks for your sharing 👍
Why the music?
EXCELLENT VIDEO
Very factual video...... Nice Keep it up... Put some more videos ......
There are lots of video on Foundation, Erection, Stringing, OPGW, UG Cable.
Visit my page to grab more and pls share if you liked it
Foundation- ruclips.net/video/W5G2TwDWSnU/видео.html
Erection- ruclips.net/video/vrDC-Dfnnhw/видео.html
Under Ground Cable- ruclips.net/video/armLWFEi8tk/видео.html
OPGW- ruclips.net/video/armLWFEi8tk/видео.html
Pile Load Test- ruclips.net/video/trnrUBUCXGo/видео.html
Scaffolding- ruclips.net/video/5wLxlq6JE40/видео.html
Erection- ruclips.net/video/C-QhkGbxryQ/видео.html
Stringing- ruclips.net/video/4Lje07848bE/видео.html
Conductor Sagging- ruclips.net/video/UsmXO7KNBlc/видео.html
Tower Testing- ruclips.net/video/m0LtgEh5JIc/видео.html
Very nice !
អរគុណ👏
keep it up
Không tra mỡ bảo dưỡng lõi thép và mỡ tiếp xúc lõi nhôm hả
Nice video
But sir plz name the stand which support the cable drum
Drum Lifting Jack- Spindle is more strong than ordinary one
good and informative
veda akula Thanks
Any jsa available please share with me myself email tahirhse.fatima@gmail.com
e-mailed
Proud to be an engineer
Wonderful
Knowledgeable
Ima blackman I tell you Indians are goodlinemen too
Yup
Great video
Slute to those workers, really hard job to do
WOW!
Darun bhai...
Thanks
Safety First
Great
Would have been better without the music and ridiculous visual effects
Hard job for all linemen
Thank you boss
Welcome
Informative
I think Bariq~Muhail 132kv line
Thanks for like
220 kv
Awesome
different work like the video
I need 11kv cable jointing technician. Can you provide??
ya I can send the place where u need it
Nice
Good
How much Compression force is applied to make steel and aluminium mid span and dead end joints
800 to 1000bar
What is the price for the hydraulic cable compressor?
Are not you using a metal mesh for getting the induction?
What's metal mesh please explain me about this?
The worst thing in this job is the heat of the sky🌞. The worse is only -15 ° C🌨 and frostbitten hands. 🔌👲👍⚡
Exactly
How heavy is the spool at 0:58 ?
Sem equipamentos de proteção. Cade a segurança?
Kuch chijo ko sequence
Me dena chahiye
Where is the safety gloves :/
Send me TL procedures
👍👍👍👍
how to know that line is 33kv, 66kv, 132kv. Please help me
Hie....
The answer to ur query
There are several guiding factor which determine the rating of T/L
1. Insulator- Generally each disc of Insulator comes with rating of 11kV
So, Line voltage can be assumed= No. Of disc * 11*1.73
This formula hold good above 132kV
Below 132kV= No. Of Insulator*11
Now a days, various different rating insulator are coming. Example- long rod Insulator In that u have to check the bundling of conductor also
2. No. Of bundle- generally twin bundling is used below 220kV. Above 220kV quad, hexa etc used
I bet it takes years to put them up completely
MassiveKilla93xx ha ha
Fortunately the video is completed within 7 days.
good work.... ye kon c company hai.... India me hai keya...?
One of the renowned company of India
Sir I am ITI electrician pass
No gloves got my eyes
What is the size of the conductor?
In the video it is 28.11 mm
Panther or zeberg
Its ACSR/AW Drake
स्टोर कहां है सर
Tell your worker to use cotton gloves
Sir mujhe foundation drawing ka sara videos chahiye
Bhai mujhe bataye opg kaya hota hai
Sumit das
Watch the video on OPGW in below link.
ruclips.net/video/y6rll-kGdZ0/видео.html
Feel free if you have any queries afterward
Hi
Are not you using rolling grounding?
Justo Benjamín Ágreda Tejera Ground roller is used. It is shown in video
Yes Sr. I saw it. but we use other kind of ground roller, they are closer to the machines. And we use equipotential mesh under the machines too. I can see that your way to work is very diferent. Great video¡, thanks¡
Justo Benjamín Ágreda Tejera Actually it varies from region to region. Also vary with client requirement
Which video.
Location kahan ki hai sir
Saudi Arabia
Contact Mail ?
Transmission line ke tar itne thick Kyu hai.
Q ki ye EHV line hai or ye moose conductor 400kv overhead transmission line me use hota hai.
Technically it depends on no. of factor. Major factor which determine the dia of conductor is current carrying capacity, however the dia is also limited by skin and proximity effect.
Eg
Way too slow, there are so many things require improvement
Feedback/recommendation on the observed deficit are highly appreciated.
Safety System much poor..
Feedback/recommendation on the observed deficit are highly appreciated.
Not safe no gloves no proper training were is your safety engineer soppose to be he should responsible for this video. Remember it's a risky working on high voltage of electric safety first before you posted in you tube just saying only cause work also on the same category but not like this no safety gloves
I understand ur concern and appreciate for putting ur valuable comments. Pls be noted that construction is under progress and the line is not energized so no high voltage gloves are require. Only general gloves can be worn to avoid any small cuts.
@@PritamSingharoy yup. Right
Great work
Good
Good