Resided does well! As a manufacturer of home products in the market, education or product training is very important for gaining more market share! When you have the customers in you mind, you customers will have in their mind.
Nomaly open normaly closed acutvate systom chilled water supey line opn retan is out re culashioned ar colde syom supply is oped ned th cnrolled pwer brown and blue N guve open closed brown and black cosed
Thanks so much , very helpful. After refitting a new synchron notor the valve is not full closing through the spring pressure so CH is now on a bit when HW on. Was it necessary to slide the manual lever to open when refitting the motor , I think I did that but can’t be sure? What do I need to do re resetting valve to fully close. Happy to remove motor and refit, it’s as if the valve needs to be reset fully open or shut the motor back in. Right now manual lever slack until last 1cm of travel to manually open. Oh and my Synchron motor did not come with new machine screws, the originals are slot head brass and super fiddly to refit, most motors come with cross head machine screws.. what size are they? ( this is an older Honeywell head that cannot be replaced without a drain down) Would be so grateful for help here. Regard Mike
Why doesn't, anyone actually show the position the spigot should be in to replace the new actuator head? if it was removed a while prior to the new replacement?
Brilliant. I had issue when in winter I wanst getting heating on downstairs but upstairs was fine. Then engineer came n changed heating 2port zone valve, still no heating downstairs then flushed whole system, still no heating downstairs then changed the thermostat n it's main signal box. Slowly started getting heating everywhere. But now I'm getting heating on when I turn water on and getting water on when I turn heating on. I can't get anyone to sort this. As it was winter I never turned water on as I was getting boiling water with heating. But now its summer when I turn water on I'm getting heating and I just need both water and heating to work independently. Last year thermostat for timer has also been replaced as thot that may b the issue. Some one pls pls help and advice me. Ppl are saying the 2port zone valve replaced is faulty?
Great video well explained good man
Resided does well! As a manufacturer of home products in the market, education or product training is very important for gaining more market share! When you have the customers in you mind, you customers will have in their mind.
Good video nicely explained and easy to see.👍
Nomaly open normaly closed acutvate systom chilled water supey line opn retan is out re culashioned ar colde syom supply is oped ned th cnrolled pwer brown and blue N guve open closed brown and black cosed
Thanks so much , very helpful.
After refitting a new synchron notor the valve is not full closing through the spring pressure so CH is now on a bit when HW on.
Was it necessary to slide the manual lever to open when refitting the motor , I think I did that but can’t be sure?
What do I need to do re resetting valve to fully close. Happy to remove motor and refit, it’s as if the valve needs to be reset fully open or shut the motor back in.
Right now manual lever slack until last 1cm of travel to manually open.
Oh and my Synchron motor did not come with new machine screws, the originals are slot head brass and super fiddly to refit, most motors come with cross head machine screws.. what size are they? ( this is an older Honeywell head that cannot be replaced without a drain down)
Would be so grateful for help here.
Regard
Mike
Is that brass or copper the zvalve
Why doesn't, anyone actually show the position the spigot should be in to replace the new actuator head? if it was removed a while prior to the new replacement?
Brilliant. I had issue when in winter I wanst getting heating on downstairs but upstairs was fine. Then engineer came n changed heating 2port zone valve, still no heating downstairs then flushed whole system, still no heating downstairs then changed the thermostat n it's main signal box. Slowly started getting heating everywhere. But now I'm getting heating on when I turn water on and getting water on when I turn heating on. I can't get anyone to sort this. As it was winter I never turned water on as I was getting boiling water with heating. But now its summer when I turn water on I'm getting heating and I just need both water and heating to work independently. Last year thermostat for timer has also been replaced as thot that may b the issue. Some one pls pls help and advice me. Ppl are saying the 2port zone valve replaced is faulty?
Im is this everything works well valve just is warm all the time, is it supposed to be like that ?
Stop commenting in English please.
Most of the civilised world does old chap, or should I say? "P*icKerlot"@@philmerlot9074
Appreciate ,
More about faults finding and wiring diagram