  • @manishkumarpandey8321
    @manishkumarpandey8321 2 года назад +2

    A big mistake i observed in this design is that calculation of bearing strength of bolts was done when t=10mm. But summation of thickness of cover plates is coming to be 8mm. So Σt=4+4= 8mm and this should be used in calculation of bearing strength of bolts and bolt value will be 58KN and so we require 5 bolts.

    • @manishkumarpandey8321
      @manishkumarpandey8321 2 года назад

      Else provide splices of 5mm thickness each. Which is minimum criteria

    • @kishlayjha1561
      @kishlayjha1561 Год назад

      Thickness of the splice plate is calculated at the latter stage 10 mm is absolutely correct.

  • @sachinkarmankar6753
    @sachinkarmankar6753 3 года назад +1

    Thank you sir

  • @hasanshirazi9535
    @hasanshirazi9535 7 лет назад +4

    @ 24:00 Plan drawing is not correct, it does not show splice plates.

  • @ChandanKumar-uf5yd
    @ChandanKumar-uf5yd 3 года назад

    Sir ,
    Happy New to you first.
    Sir I have a question.
    I am constructing a steel frame structure in which 4 ISMB 250 column is there with 3.47 m height each.Total dead load is 120KN. But main issue is contractor cut all four column of 3.3 m height .What will i have to do??
    Contractor welded 170 mm ISMB 250 mm peice with cover plate on both flanges and web and that is too welded,and kept all joint below the roof level.
    Is it enough to resist load??

  • @shimish
    @shimish 4 года назад

    Thank you so much sir.

  • @dilkhushmeena534
    @dilkhushmeena534 6 лет назад

    thank uh sir

  • @hasanshirazi9535
    @hasanshirazi9535 7 лет назад

    Splices in Tension Members
    Course website: nptel.ac.in/courses/105105162/

  • @singhdurgesh660
    @singhdurgesh660 5 лет назад +1

    Fu=410