Just how easy is it to install outside power and lighting. PART 1

Поделиться
HTML-код
  • Опубликовано: 30 авг 2023
  • Electrician installing outside power and lighting. Shed summerhouse or workshop.
    I’m running the London marathon in 2024 if you’d like to sponsor me please email me at
    Chris@hrservices.uk and I will send you the link.
    This video is for entertainment purposes only please dont try to copy or recreate this video in anyway. Do so at your own peril!!!
  • ХоббиХобби

Комментарии • 106

  • @Cjrelectrical
    @Cjrelectrical  9 месяцев назад +2

    Cable depth is around 20 inches. Only place it isn’t is under patio slabs and on top of a French drain. Just to help with any comments coming in.

    • @TheRCBiker
      @TheRCBiker 9 месяцев назад +10

      5:28 c'mon mate don't take us for fools, that looks barely 20cm never mind 20 inches!

    • @Cjrelectrical
      @Cjrelectrical  9 месяцев назад +1

      Under patio yes I agree as it’s quite pointless. But on the grassed area I can assure you it’s deep enough.

    • @TheRCBiker
      @TheRCBiker 9 месяцев назад

      @@Cjrelectrical 👍

    • @spoon1272
      @spoon1272 9 месяцев назад +2

      lmao... That is nowhere near 20 inch deep on the grassed area. 20cm maybe... and that would be pushing it..

    • @strummer6642
      @strummer6642 8 месяцев назад

      What's the difference between 20 inches and deep enough? About 8 inches.

  • @NBundyElectrical
    @NBundyElectrical 9 месяцев назад +3

    good to have u back bud

  • @robweedall6002
    @robweedall6002 9 месяцев назад

    Lovely stuff! Nice to have you back!
    Personally id have fed the next leg downwards so i don't have to pull the whole length to the next point through the conduit, also its easy to get the bush out if you're struggling!
    But whatever works!
    Looking forward to part 2!

  • @shaun30-3-mg9zs
    @shaun30-3-mg9zs 9 месяцев назад

    Nice work👍

  • @bertbergers9171
    @bertbergers9171 9 месяцев назад

    Hi Chris, good to see some footage of you guys again!
    I wondered how your explaining was talking of following the edge of the lawn and then in execution you made a near straight run through the lawn. Then you talked sense with the underground system being there.
    Running cable in gardens is never easy.
    I once wired a blockcabin in the backyard of my uncle (under tips and tricks of a real electrician). (in the Netherlands) I Located a fuseboard 30 cm off the floor and ran my distribution in conduit in the underfloor insulation, then came up 30 cm to sockets around the cabin and on two spots i ran conduit up 2 meters strait, but i picked spots where i could bend a 90 and leave it unclamped for like a meter. The rest of those runs i kept horizontal on the same woodlayer.
    I made 2 more t's in one of those runs into the sauna (with temp capable cable) and put 2 loops in those drops (for lighting).
    The 3-phase heating element in the sauna was wired underground in conduit from the consumer board (by the electrician himself) which i located on the backwall of the sauna in the adjacent room.
    Why all this: well, because of the cabin company telling us the wood shrinks and grows every season and i didn't want to leave tension on the wiring.
    I am curious if you made a loop inside the consumer board to give the wiring space for growth and shrinkage?
    Also the cable on the outside of the building might get under some tension?
    At least you filmed this in a wet summer so the shed could be not to much on it's lowest point.
    Maybe UK is so wet year round you don't get too much dryness shrinking the building anyhow.

  • @AcheForWake
    @AcheForWake 9 месяцев назад

    Great work! I’ve just build my Dunsterhouse - to use as a home office, require your services to electrify it.

  • @Cjrelectrical
    @Cjrelectrical  9 месяцев назад +1

    New circuit was not an option. Consumer unit is only there to distribute the power easily when garden lighting will be added. Can go on a minor works as not a new circuit or to fit all on could go on an electrical installation certificate. If they required anymore than 13amp a ie for a fridge heater or similar then we would have installed a new circuit.

  • @fatpedro5588
    @fatpedro5588 9 месяцев назад +1

    Quick tip I learnt with feeding cable through conduit. Rub fairy liquid over it. It slides through a lot easy.

  • @piotrlobacz
    @piotrlobacz 9 месяцев назад +2

    I have done a socket ring in my garage with t&e in 20mm conduit. Never again. Rewired it with singles.

    • @tuboid001
      @tuboid001 9 месяцев назад +2

      Yep, 20mm conduit is not suitable for 2.5mm T&E cables, singles all the way.

  • @PaulHeath9
    @PaulHeath9 9 месяцев назад +3

    Log cabins expand and contract mainly in a vertical direction. Can be more than 20mm. Hence the reason the windows and door frames are not attached to the cabin walls. The way you've attached things the tubing will get pulled out of the socket boxes or the top trunking.

    • @Cjrelectrical
      @Cjrelectrical  9 месяцев назад +1

      We shall see 👍

    • @davecowan9466
      @davecowan9466 9 месяцев назад

      What would you suggest @PaulHeath9

    • @PaulHeath9
      @PaulHeath9 9 месяцев назад +1

      ​@@davecowan9466Mount the consumer unit low at the hight of the sockets and make sure everything is only attached to one row of logs.

    • @PaulHeath9
      @PaulHeath9 9 месяцев назад

      Use plug in lamps to light the cabin

    • @alextitov2086
      @alextitov2086 9 месяцев назад

      @@Cjrelectrical From a personal experience - as an owner of a log cabin for twenty years - those vertical plastic tubes (inside and outside) won't stay a few years unfortunately. Uninterrupted trunks (or tubes, or whatever) can run only horizontally. For vertical cables - each log should have a separate trunks or tubes with either a few millimeters gap between them (accepted by regulations), or loosely plugged into each other, so they can move up and down according to contraction and expansion of the wood. The cable is to be loose as well, otherwise it may lead to more serious problems (in the wet condition the wood expands and the conduit connection may become loosen). All together - manually intensive labor, requires time. And might lead to increase in the installation cost.

  • @markharby180
    @markharby180 9 месяцев назад

    'Brute force and ignorance ...' not heard that in a long time ;-)

  • @MHALI-qv9yc
    @MHALI-qv9yc 9 месяцев назад

    how much did you charge for this job? by the way you have done a nice job of it.

  • @no_short_circuit
    @no_short_circuit 9 месяцев назад +5

    Hi Chris, thanks for the video. As a trainee can I ask why (at 6.24) the banjo is on the outside of the Wiska box. I understand that the continuity of the SWA must be maintained but would having the banjo outside mean you need to drill through the IP66 box to connect to earth and by doing that are you not compromising the IP rating?

    • @baz5329
      @baz5329 9 месяцев назад

      Reason why earth locknuts are used

    • @no_short_circuit
      @no_short_circuit 9 месяцев назад

      @@baz5329 Thanks for that - I understand the earth locknut is inside the box so what function does the banjo have when it's outside the box and not connected to anything?

    • @baz5329
      @baz5329 9 месяцев назад +3

      @@no_short_circuitit’s in contact with the gland, which keeps the sheath earthed

  • @Blenkinsop999
    @Blenkinsop999 9 месяцев назад

    That manhole cover at 0:51 sends my OCD into overdrive.

  • @calvinhale9913
    @calvinhale9913 9 месяцев назад +1

    Personally would've gone for singles or 25mm conduit. and would've buried that cable around the outskirts of the lawn and chucked a few bags of shingle on top. Other than that it's a shed ! :)

    • @Cjrelectrical
      @Cjrelectrical  9 месяцев назад

      Exactly. Only reason went across is due to a French drain around the outskirts.

    • @calvinhale9913
      @calvinhale9913 9 месяцев назад

      @Cjrelectrical oh yes you did mention that 👍🏻

  • @123mikeyd321
    @123mikeyd321 9 месяцев назад +1

    Great stuff. Can I ask as a non electrician, why the fuse board in there? Wouldn't a fused spur for the lights, and the sockets off the incoming supply be just as good? Is it just for room to terminate the cables in?

    • @Cjrelectrical
      @Cjrelectrical  9 месяцев назад +8

      Yes absolutely but down the line the client is adding outside lighting etc so it’s easier to distribute the power with a small consumer unit.

    • @colinpenfold2971
      @colinpenfold2971 9 месяцев назад

      DP isolation should be installed at a separate structure (as you have done) Using the above method suggested does not give you that (as often is the case)

    • @thedarkweeally
      @thedarkweeally 9 месяцев назад

      ​@@colinpenfold2971Didn't Chris say the incoming supply would taken from a double pole fused switch located inside the home mate?
      I'm sure he did.

    • @colinpenfold2971
      @colinpenfold2971 9 месяцев назад

      @@thedarkweeally Probably did. My point was in answer to 123mikeyd321 comment i.e. DP isolation required at a separate building, which he has done with the DB in the outbuilding. If the supply is from a SFCU (DP 13A) in the main property, then there is a selectivity issue by putting a 16A mcb downstream.

    • @bertbergers9171
      @bertbergers9171 9 месяцев назад

      @@colinpenfold2971 there is no issue, the fused spur will allways go first.
      The 16A breakers are not for safety but for distribution.
      Maybe Chris could have exhausted safety by putting a sticker on the fuseboard to tell users not to load the board over 13A total. But that is a bit much in my opinion, client asked for the fused spur option, so imho it's their responsibility to remember somehow that they can't overload the shed.
      Also their responsibility to notify future owners/users of the house about the 13A max load.

  • @203MPH
    @203MPH 9 месяцев назад +1

    Just wondering, is there no minimum cable depth in the UK?
    In the Netherlands cables should be at 500mm minimum.

    • @Cjrelectrical
      @Cjrelectrical  9 месяцев назад +1

      450mm this was buried at 20 inches where possible.

    • @203MPH
      @203MPH 9 месяцев назад

      @Cjrelectrical thanks for the reply.

  • @user-qb9tc8fo8x
    @user-qb9tc8fo8x 9 месяцев назад

    Any techincal reason to run trunking inside rather than conduit on the exterior and back entry all the sockets?

    • @Cjrelectrical
      @Cjrelectrical  9 месяцев назад +2

      Yeah the outside has overlapping wood and didn’t want to drill the timbers.

  • @tuboid001
    @tuboid001 9 месяцев назад

    Daft trying to ram 2.5mm T&E cables down 20mm conduit, that's what singles are for!

  • @cjkokay
    @cjkokay 9 месяцев назад +1

    Safety glasses

  • @jasonmart1081
    @jasonmart1081 9 месяцев назад +6

    Sparkies always come up with excuses for never going to the advisable 500mm depth with buried cables 🙄😅 Why didn't you make your life easy and use singles in the conduit (I suppose most domestic sparks don't carry/use singles that often)?

    • @613klj
      @613klj 9 месяцев назад +2

      I had an electrician install electrics in my shed a year ago. I was told to dig the trench to 450mm. I hope I never have to dig a trench again.

    • @steve11211
      @steve11211 9 месяцев назад +2

      @@613klj Yep 450mm is the minimum with tape laid around 150mm above the cable. I totally agree with him though it is pointless putting tape over it when its only like 100mm below the ground, cause if you dig you will hit the cable straight away rather than finding the tap... Absolutely shocking... Bet he won the job cause he was much cheaper than the other guy that would actually bury the cable to the correct depth..

    • @Cjrelectrical
      @Cjrelectrical  9 месяцев назад

      We did bury the cable at around 20 inches where possible.

    • @steve11211
      @steve11211 9 месяцев назад

      @@Cjrelectrical Really? I have dug trenches that are at least 450mm, its surprising just how deep that is.. Its almost half a meter, I tend to go 500mm so I can lay 50mm of sand to lay the cable on... Maybe its the camera but it looks like its about 100 - 150mm.. Apologies if it is actually 20 inches which is 50cm or half a meter. When I stand in a trench that is 50cm deep the ground level is above my knees.

    • @Cjrelectrical
      @Cjrelectrical  9 месяцев назад +3

      Yeah a standard spade head is 10 inches long and I went double so around 20 inches. I will be sure to stick a tape measure in on the next one to help with any confusion.

  • @edglue6138
    @edglue6138 8 месяцев назад

    Why isn’t James using drill with chisel bit to get concrete up?

  • @Tom-2221
    @Tom-2221 9 месяцев назад

    Nice to see common sense applied with the depth of the cable. Customer is aware of it and will know not to go digging there.
    Great install, I'd be happy if I were the customer.

    • @swifty5783
      @swifty5783 8 месяцев назад

      Thats not the point surely? You wouldn't use that reasoning to run a cable chase diagonally outside of zones - customer is aware of it and won't go drilling there. The homeowner may move house in the future and the new owner may not know where the cable goes or how deep it is. It needs to be deeper than a few inches with proper protection and warning tape to future-proof its safety

    • @martin-davidson
      @martin-davidson 28 дней назад

      Just do a risk assessment 👍

  • @mickuljatheseagull
    @mickuljatheseagull 9 месяцев назад +1

    Ah Chris, "a tiny mil", is that the opposite to "a good metre"?

  • @RB-xg2vz
    @RB-xg2vz 9 месяцев назад

    Hope the assault on James by the metal level went in the accident book??? 😅

  • @brettuk
    @brettuk 9 месяцев назад +1

    have you lost your rods? :)

  • @doomain6769
    @doomain6769 9 месяцев назад +1

    When your level hit james on head... Should have said " might help you think straight"

  • @Daniells1982
    @Daniells1982 9 месяцев назад +1

    The consumer unit via a switched fused connection unit was an odd way of doing it mind and I dont think that complies.
    I'd have either ran a new circuit in if u want to put a small CU in there, or spur off the ring as you have done with a 13A switched fused connection unit and just wire the sockets as a radial and a switched fused connection unit derated to 3A for the lights.
    How would u even fill out the test cert for a CU installed off a ring final circuit? Are they new circuits or an alteration to an existing?
    Not having a go mate just didn't get this one and not your normal way of approaching a job.

    • @tobysherring1369
      @tobysherring1369 9 месяцев назад +2

      It's a spur and can be tested as such. Adding a CU doesn't make it a new circuit. But I agree with others a 5a spur for lights would be simpler, and could feed future extra lighting.

  • @steveb1856
    @steveb1856 9 месяцев назад +9

    Mini fuse board with 16A radial coming off a supply from a 13A fcu spur from the house. Why as discrimination is backwards?

    • @adamdavis2788
      @adamdavis2788 9 месяцев назад +1

      What would you do in this situation then?

    • @steveb1856
      @steveb1856 9 месяцев назад +5

      Armour to Wiska then 2.5 T&E radial (already fused at 13A in house) to sockets with a FCU fused down to 5A, load side for the lights wired in 1mm T&E.

    • @Cjrelectrical
      @Cjrelectrical  9 месяцев назад +2

      @@steveb1856consumer unit just gives ease of adding garden lighting etc down the line.

    • @martinbateman2467
      @martinbateman2467 9 месяцев назад

      Did something similar myself for garden & pool lights and a shed

    • @Mainly_Electrical
      @Mainly_Electrical 9 месяцев назад +1

      Should be a 10 amp in the board

  • @jan-dr1xl
    @jan-dr1xl 9 месяцев назад +3

    I thought an earth rod was required if the supply was TNC-S so your not extending the supply earth outside the equipotential zone due to the possibility of a potential difference between the earth your standing on and the supply earth.,And im sure the trench depths supposed to be 450mm not 45mm.

    • @lissa020609
      @lissa020609 9 месяцев назад

      I think your correct but at the same time you need to be around 10m away from any metal pipeing in the ground ect witch isn't rely possible in most domestic settings due to other houses other wize it's not rely on a tt because of the bonding to the pipes in the house that go underground ud be just putting a extra earth rod into the pme system or that's my understanding of it

    • @Cjrelectrical
      @Cjrelectrical  9 месяцев назад +1

      It’s a shed mate only need its own earthing system if made from metal.

    • @jan-dr1xl
      @jan-dr1xl 9 месяцев назад

      Tents aint made of metal but were still required to use a rod for supplies on campsites if the incomer is TNC-S

    • @Cjrelectrical
      @Cjrelectrical  9 месяцев назад

      @jan-dr1xl applies to caravans and motor homes.

    • @tuboid001
      @tuboid001 9 месяцев назад +1

      This only applies if you have metallic water/gas services also going to the shed/cabin.

  • @calitos55
    @calitos55 8 месяцев назад

    pea gravel - tape - sand

  • @stevespoor6567
    @stevespoor6567 9 месяцев назад +1

    I was told, your not allowed to install a consumer unit to a ring circuit? (NICEIC)

    • @Cjrelectrical
      @Cjrelectrical  9 месяцев назад +2

      It’s not being fed from a ring circuit. It’s off a 13amp connection unit. The consumer unit is for ease of switching and adding additions later on.

    • @Mainly_Electrical
      @Mainly_Electrical 9 месяцев назад

      No you shouldn't . The spur will melt

    • @Cjrelectrical
      @Cjrelectrical  9 месяцев назад +1

      🤣

    • @Mainly_Electrical
      @Mainly_Electrical 9 месяцев назад

      @@Cjrelectrical 🔥remove the board and fuse the lights down . Basic stuff kiddo

    • @Cjrelectrical
      @Cjrelectrical  9 месяцев назад

      Ok little sausage.

  • @Kikz-1v1pinginit
    @Kikz-1v1pinginit 7 месяцев назад +1

    I prefer to run all the conduit work on the exterior down low and come up to a junction box to drill into the cabin for the power and come up high from the rear of the cabin for the lights. That conduit and ducting inside the cabin is a eye sore, no one wants to see conduit work, looks horrible

  • @mikebashford8198
    @mikebashford8198 9 месяцев назад +2

    All that electrical training, and then you have to dig trenches ...

  • @andysims4906
    @andysims4906 9 месяцев назад +2

    It amuses me people do unsatisfactory work then advertise the fact they have done a inferior job on here.
    There is no way you can make excuses for not burying that cable it the correct depth . Oh it’s RCD protected. RCDs can fail. In the very rare case I can’t get a section to the correct depth. I sleeve or run the whole section in heavy duty plastic pipe.
    I also recommend the customer gets someone else to dig it if they can to save on my labour cost.

    • @Cjrelectrical
      @Cjrelectrical  9 месяцев назад +4

      There is no correct depth unless you are burying cables on a camp site for obvious reasons. Please use your common sense Andy.

    • @andysims4906
      @andysims4906 9 месяцев назад +4

      @@Cjrelectrical common sense tells me this is not acceptable. Just imagine could have kids want to put a tent up in the back garden . Or a swing ball . Even a free standing bird feeder .the list goes on .

    • @jamieisbadiof6106
      @jamieisbadiof6106 9 месяцев назад

      @@andysims4906 have you been abused or are you just mentally unstable ? get a grip ffs

    • @speedbird300
      @speedbird300 9 месяцев назад +1

      I’d agree it’s unlikely someone would dig in the lawn but a spike or hollow core.aerator wouldn’t be unusual

    • @1A9lis
      @1A9lis 9 месяцев назад +2

      Hi sir I new you would come in for some grief over the armer cable depth , and also the 13 amp fuse supply . But as you rightly said your are limited to 13 amp fuse which in reality would react as designed in an overload situation , and as for the cable in the ground as electrical contractors we have to make common sense decisions every day of our working lives . And this is exactly what you did , obviously we have to be sensible but as a well retired contractor I can say you work is always well above board . A statement that I could not say about many in the industry , were I spent a lot of my time rectifying work that had me wonder how the individuals concerned slept at night . Also in many cases were not talking about single phase supplies , no the stuff that if you come a cropper you don’t get up and walk away from . But I will give you and everyone a tip for an old lag . We found if you leave the sockets off and then push the two cables down the conduit first, even before fixing the saddles in place . So you have your cables coming out of the trunking and you then slide the conduit up , and because you can angle the conduit it makes life a lot easier and who’s not for an easy life 😂. Best wishes and kind regards. 😀👍👍👍