    The common Turbidity Meters use incandescent lamps as light sources, which emit a broad spectrum. The wide range of wavelengths can cause colorimetric interference in turbidity readings. Also, incandescent lamp output tends to reduce over time. Due to this frequent replacement of lamp & calibration is required.
    Model NT 4000 uses a narrow band monochromatic light source ( I R LED ). It has a long life & very less wavelength interference.
    Spectralab Model NT 4000 Turbidity Meter is benchtop turbidity meter and is the most advanced portable microcontroller based Turbidity Meter. It is based on nephelometric and ratiometric principles of turbidity measurement. It uses LED & meets EPA 180.1 and ISO 7027 as well as an infrared ratio ( IR ratio ) mode that gives results in accordance with EPA GLI method 2. It has a memory to store 40 results. The data can be transferred to PC & then printouts can be taken in a document format with the report number, data & time.

Комментарии • 38

  • @mltknowledge4534
    @mltknowledge4534 4 года назад +1

    Knowledgeable

  • @moonharjai
    @moonharjai 3 года назад

    Very nice and informative ..👍🏻 Keep uploading more videos ..

  • @mohitsingh4603
    @mohitsingh4603 3 года назад +2

    That was good. Could you please tell about the principle behind the working of this instrument.?

    • @AnalyticalTech
      @AnalyticalTech  3 года назад +2

      Turbidity is an optical property of water based on the amount of light scattered and absorped by collodial and suspended

  • @nappoleanyoung9517
    @nappoleanyoung9517 2 года назад +2

    Can someone tell me or send a link to where I can find a table or any info on a reference standard of the acceptable level of turbidity in drinking water?

    • @AnalyticalTech
      @AnalyticalTech  2 года назад

      www.indiawaterportal.org/articles/indian-standard-drinking-water-bis-specifications-10500-1991

    • @nappoleanyoung9517
      @nappoleanyoung9517 2 года назад

      @@AnalyticalTech thank you

  • @darshandarshi2563
    @darshandarshi2563 3 года назад +1

    Thank you 👍👍

  • @javiermaximoignacioapaza2603
    @javiermaximoignacioapaza2603 8 месяцев назад

    Good morning, I am writing to you from Peru, I would like to know if the calibration cuvettes can also be used for the Turbiquant 1100 T turbidimeter?...Thank you

  • @Kushal.895
    @Kushal.895 2 года назад

    Very good

  • @prakashpawar9154
    @prakashpawar9154 3 года назад

    nice sir thanks for video🙂🙂

  • @gracefulheart7910
    @gracefulheart7910 4 месяца назад +1

    Background music is quiet disturbing

  • @anshkhobragade6440
    @anshkhobragade6440 8 месяцев назад +1

    name of song please

  • @karenclaireluzon5470
    @karenclaireluzon5470 3 года назад

    Sir where did you buy the water solution for calibration?

    • @AnalyticalTech
      @AnalyticalTech  2 года назад

      It's come with instrument. For preparation in laboratory by hydrazine sulphate solution.

  • @UmeshKumar-dh8wr
    @UmeshKumar-dh8wr Год назад

    Sir calibration error show karta hai ka kare

  • @ramesingh570
    @ramesingh570 3 года назад

    sir, please tell me the cost of the instrument.

    • @AnalyticalTech
      @AnalyticalTech  3 года назад

      Not too much. Price is varried. Please go through to company website.

  • @aroy914
    @aroy914 Год назад

    How much samples has taken ???

  • @siddheshtaware6345
    @siddheshtaware6345 2 года назад

    Can you send me terbidity calculation formula

    • @AnalyticalTech
      @AnalyticalTech  2 года назад

      No formula in turbidity parameter. It's experiment value

  • @Kushal.895
    @Kushal.895 2 года назад

    Hindi ma

  • @crazyexpriementknig543
    @crazyexpriementknig543 Год назад

    Hindi me translate Karo please Sir.

    • @AnalyticalTech
      @AnalyticalTech  9 месяцев назад

      ok i will make a hindi video version on it.

  • @user-rn1gk6cs5t
    @user-rn1gk6cs5t 2 года назад

    Sir please tell me Hindi language sir