Earthing for Net metering & for Lightning Arrestors / IEC NORM Commissioning 03453540734

Поделиться
HTML-код
  • Опубликовано: 28 авг 2024
  • Earthing for Net metering & for Lightning Arrestors / IEC NORM Commissioning 03453540734
    IEC NORM Commissioning for Lightning Arrestors / Grounding / Earthing for 40 Kilowatts solar energy Project
    Material list.

Комментарии • 48

  • @zeeshanshahid2020
    @zeeshanshahid2020 4 года назад +3

    What a quality of work......

    • @HibaTradingSMCPVTLtd
      @HibaTradingSMCPVTLtd  4 года назад +1

      Thank you Sir,
      Still.we're trying to improve ourselves

    • @quincyaugustus2506
      @quincyaugustus2506 3 года назад

      I dont mean to be so offtopic but does anybody know a method to log back into an instagram account?
      I was stupid forgot my login password. I would love any tips you can give me.

    • @williamryder4094
      @williamryder4094 3 года назад

      @Quincy Augustus Instablaster =)

    • @quincyaugustus2506
      @quincyaugustus2506 3 года назад

      @William Ryder thanks so much for your reply. I got to the site thru google and im waiting for the hacking stuff now.
      Takes a while so I will get back to you later with my results.

    • @quincyaugustus2506
      @quincyaugustus2506 3 года назад

      @William Ryder It did the trick and I actually got access to my account again. I am so happy:D
      Thanks so much, you saved my ass :D

  • @mahmoodahmad5326
    @mahmoodahmad5326 Месяц назад

    بہت اچھا کام کیا ھے آپ نے ۔۔۔اگر کاپر راڈ کے بعد کاپر وائر پر پی وی سی پائپ چڑھا لیا جائے تو کاپر وائر زیادہ محفوظ نہیں ھو جائے گی Oxidized ھونے سے؟؟؟؟

  • @abdulbaseer3910
    @abdulbaseer3910 4 года назад +1

    MsahAllah Bht Axha Kam Hai Apka.

  • @muhammadabrar6296
    @muhammadabrar6296 4 года назад +1

    I am big fan of your videos brother

  • @abdulbaseer3910
    @abdulbaseer3910 4 года назад +1

    Asalamualikum Bro, MashAllah Bro Keep It up.

  • @abdullahahmed6054
    @abdullahahmed6054 4 года назад +1

    Masha Allah

  • @skoto.power.systems
    @skoto.power.systems 4 года назад +2

    Good job

  • @NIRANJANKUMAR-sf4ww
    @NIRANJANKUMAR-sf4ww 2 месяца назад

    20 kilo watt lod के लिए कौन सा earthing कराना चाहिए

  • @wilbanwilliamwilban3013
    @wilbanwilliamwilban3013 3 года назад +1

    Supper earthing

  • @abdulbaseer3910
    @abdulbaseer3910 4 года назад +1

    Bhai Jaan Battery Bus Bar py Total 10 + or 10 - Wire connect hain or ap khe rahy hai k total 12 banks hain.

    • @HibaTradingSMCPVTLtd
      @HibaTradingSMCPVTLtd  4 года назад +2

      Abdul Baseer sb.. Really thanks for watching,
      And special thanks for raising a question.
      Actually hum logo ne battery bank ki bus bar per busbar ki back se and front pe lugs connect kiye howe hein

  • @abdulbaseer3910
    @abdulbaseer3910 4 года назад +1

    Or bhai jaan pv connection k bary main b bta dain kitny panels hain or kitni strings banai hain

  • @abdulbaseer3910
    @abdulbaseer3910 4 года назад +1

    thora sa bta dain bettery bus bar k bary main detail main

  • @muhammadrayyan5936
    @muhammadrayyan5936 6 месяцев назад

    It is mandatory to install 3 separate earthings for AC, DC and Lightning Arrestor

  • @legaldirectoratemepcomulta7965
    @legaldirectoratemepcomulta7965 11 месяцев назад +1

    Earthing par kharcha kitna ata hai

    • @HibaTradingSMCPVTLtd
      @HibaTradingSMCPVTLtd  11 месяцев назад

      Sir it depends on hardware, the hardware chosen in above VDO would've cost around 130k each

  • @gmtechomc5304
    @gmtechomc5304 3 года назад

    5 fit pe sand a rahe mai bor 20 fit tak le k gya lekin 90ohm resistance mil rahe

    • @HibaTradingSMCPVTLtd
      @HibaTradingSMCPVTLtd  3 года назад

      Apne copper rod k sath copper cable kese connect ki Howe hai?
      03113360019
      03453540734

  • @True_Muslim_Momin
    @True_Muslim_Momin 2 года назад

    Isko oxidization se kaise bachana hai??

    • @HibaTradingSMCPVTLtd
      @HibaTradingSMCPVTLtd  2 года назад +1

      NAHI BACHANA... as 1inch dia copper rod which is almost 10 ft in lenght will take tens of years to desolve in acid like lime and salt which we usually use while earthing procedure

    • @True_Muslim_Momin
      @True_Muslim_Momin 2 года назад +1

      @@HibaTradingSMCPVTLtd oxidization se iski effectiveness kum nhi ho jayegi? Jub copper k oper green layer ban jayegi

    • @HibaTradingSMCPVTLtd
      @HibaTradingSMCPVTLtd  2 года назад

      Oxidation is one form of metallic corrosion, which is a reaction that occurs during an ionic chemical reaction when oxygen is present on the metal’s surface. During this process, electrons move from the metal to the oxygen molecules. Thereafter there is a generation of negative oxygen ions in the metal, thus leading to the creation of a surface laden with oxide. In the case of copper, this oxidation occurs as a result of the exposure of copper to air, although salt water, acidic compounds and heat can also induce corrosion.

    • @True_Muslim_Momin
      @True_Muslim_Momin 2 года назад +1

      @@HibaTradingSMCPVTLtd yes, I am talking about the lightning arrestor part which is in the Air. After oxidation, is it as effective in attracting the lightning bolt as compared to no oxidation? I am trying to understand why lightning arrestors are not tin or nickel coated?

    • @HibaTradingSMCPVTLtd
      @HibaTradingSMCPVTLtd  2 года назад

      the only thing which we can do to stop oxidization is to use cathodic protection procure which is widely used in ships and bridges iskey ilawa pakistan mein SSGC apni pipe line ko oxidization se bachane k liye use karti hai

  • @zeeshan2182
    @zeeshan2182 Год назад +1

    Bht acha kam kya he bhai ap ne ap ka number chhaye

  • @DieselGeneratortraining
    @DieselGeneratortraining 2 года назад

    Jis jis bhai nay diesel generator ki training videos dekhni hai wo power learning channel per aa kar subscribe karlay free offer hain 😄 😀😀😀😀😀