Bosch Paviro PVA-4R24 Can Bus Connection Problem

Поделиться
HTML-код
  • Опубликовано: 5 окт 2024
  • Bosch Paviro PVA-4R24 Can Bus Connection Problem
  • НаукаНаука

Комментарии • 7

  • @haukefilm
    @haukefilm 7 лет назад +1

    Waht is your can bus setting? factory default or did you run at a higher rate?

    • @teknikkz4233
      @teknikkz4233  7 лет назад

      Factory default , We already send this Router on Bosch .

    • @yinkamatt
      @yinkamatt 6 лет назад

      Your CAN bus address is on 00 u need to change to 1. When on 00 the router is on standalone and cannot be discovered by the controller for firmware update.

  • @jarihamalainen9616
    @jarihamalainen9616 7 лет назад

    It's broken. RMA and factory repair will help. I have broken many Paviro shitboxes when volume override 24VDC gets into speaker line... It takes only one callout and router or controller is broken. There is no protectrion for this.

    • @haukefilm
      @haukefilm 7 лет назад

      Why do you send 24V DC into speakerline?

    • @jarihamalainen9616
      @jarihamalainen9616 6 лет назад

      Installation error in speaker lines. 24V volume override is connected to speakerlines and it will kill something inside paviro. Plena and praesideo can handle this type of installation error but Paviro will die. Let's see how the newcomer Praesensa will handle these kind of human errors.

    • @avinashsalaskar2118
      @avinashsalaskar2118 6 лет назад

      Hw V2.0 Routerboards on the PAVIRO Sys are more resistive to these errors.