#3 SW4048 settings Schneider

Поделиться
HTML-код
  • Опубликовано: 14 дек 2024

Комментарии • 41

  • @norbertrivera
    @norbertrivera 2 года назад +1

    I have the Schneider 4048 is new but the output voltage is very high instead of 220/120 Vac is reading 257/128 Vac.

    • @camosolarinc7697
      @camosolarinc7697 2 года назад +1

      I would check grounding and than call teck suport

  • @tommyvvirs1731
    @tommyvvirs1731 3 года назад

    Where do you connect your generator feed wire to the system? As well my generator is a Generac 13kw is there any special settings that need to be set? Thanks

    • @camosolarinc7697
      @camosolarinc7697 2 года назад +1

      There is good wire diagrams with the manual of your system as to the AC input

  • @ericlemnitzer9800
    @ericlemnitzer9800 3 года назад

    When my generator kicks in to support the inverter and batteries, my power kicks off for split second, I loose all power for a second or so. Everything has to reboot. I have A SW4048, 48 volt setup, AGS, and solar panels, and Conex Combox to make any changes.
    Is there a setting I need to focus on?
    Appreciate any help in this area!

    • @camosolarinc7697
      @camosolarinc7697 3 года назад

      Good morning Eric I have worked on a lot of sw Inverters and have seen this problem a few times , there is a few things it can be , what size of genset are you using ? what is the voltage and HZ settings that you programed in the SW ?
      I have seen that if the AC settings are open to big 90 to 138 volts 54 to 70 HZ it can be a problem try 100 to 138 55 to 65 hz maybe that will help ,

  • @reneroman1421
    @reneroman1421 2 года назад

    Hi...I have 2 mppt Schneider with a 6848 pro, both with 9 PV 330W
    ...they are configured primary and slave, but I have noticed that they
    do not both produce the same...the primary is always lower in production
    that the slave....do you know what my problem is?...thanks

    • @camosolarinc7697
      @camosolarinc7697 2 года назад

      well 1st i would cheak if all solar panels wires ,mc4,breakers,are good than check settings how much dif is there

  • @bigbad6994
    @bigbad6994 Год назад

    My 4048 resets whenever it runs a load over 2,000 watts. The cooling fan kicks on after 10 minutes, but it causes the system to shut off for a couple seconds, which cause all my electrical appliances to turn off, and then turn on after about 5 seconds.

  • @bambino3162
    @bambino3162 2 года назад

    Two questions. How is the Batt capacity determined? I have 8 12 v 200 AH Lithium batteries which will replace 8 12 v 200 Ah gel batteries. Whta is the voltage on this context 4048 , is it 24 or 48 volts?

    • @camosolarinc7697
      @camosolarinc7697 2 года назад

      1st question Battery Amp hour is battery is 200Ahr times voltage of the string or system so 200ahr times bat voltage of 48 volts is 9600 watts or 9.6kwh
      Or another way is 200 amphour at 48 volts.

    • @camosolarinc7697
      @camosolarinc7697 2 года назад

      the Sw4048 means 4000 watts and 48 volts dc

  • @TAGUPNBLUE
    @TAGUPNBLUE 2 года назад

    bulk charge 50 volts float at 58 cut off at 63 V lead acid batteries can handle that charge rate at 50 amps

  • @SpencerLAPower
    @SpencerLAPower 4 года назад

    Can you Bond your neutral and grounds in your breaker box

    • @camosolarinc7697
      @camosolarinc7697 2 года назад

      there is different Code laws on this please check your area

  • @ofeliavargas-w4t
    @ofeliavargas-w4t Год назад

    How to reset the fault F47 DC Under voltage CSW 4948 00

  • @plojm123
    @plojm123 4 года назад

    Hi can you explain ac support feature I want to use enphase inverters in an ac couple scenario and only use my sw as a grid backup outage scenario and rest of the time have it push out to the grid

    • @cbisolar1996
      @cbisolar1996  4 года назад

      Hi plojm123, Thank you for the comment! If you would like, give our shop a call at (403)358-7762 and one of our professionals can assist you with this.

    • @plojm123
      @plojm123 4 года назад

      @@cbisolar1996 how much?

  • @TAGUPNBLUE
    @TAGUPNBLUE 2 года назад

    You need a two pole 50 amp breaker that ties into the inverter well if you need a Schneider AGS controller and yes there are special settings for it there's exercise time runtime voltage high voltage low crank time for the generator limit output for generator if you don't use that you'll roast a generator and a GS controller will tie into the Generac start circuit diesel generator glow plug delay hand crank using the remote software package is in it where you at lot easier to go figure out all of this runs on their canbus

    • @camosolarinc7697
      @camosolarinc7697 2 года назад

      Good Day Guy im not understanding all what you are doing

    • @busboy3943
      @busboy3943 2 года назад

      Talk about a "run-on sentence"!!! Try using punctuation!! Senseless comment.

  • @neomatrix2722
    @neomatrix2722 3 года назад

    Can I add a second sw4048 to increase my power to 7000 Watts?

    • @rumsolar3728
      @rumsolar3728 3 года назад

      Thay had a lot of problems with adding a 2nd sw inverter so you can't add no more

    • @camosolarinc7697
      @camosolarinc7697 2 года назад

      NO the sw4048 and all the sw inverters had many problems with 2 hooked up most or all of them made bad smoke

  • @bambino3162
    @bambino3162 2 года назад

    As I said before , I have 8 12v 200 ah batteries. I only want to fill go 95% as its full charge (56.8v). How do I set that up on my Context sx Schneider 4048 inverter? I also don't want it to go below 52.6 which would roughly be a 50%. How to I set this up. Go easy on me I am truly a rookie in this.
    Thanks

    • @camosolarinc7697
      @camosolarinc7697 2 года назад

      you can set the Bulk and the ABS to only charge to 56.8 and set the Low Battery Cut Off LBCO on the inverter to 52.6 From Camo Solar Inc

  • @earthenergyhex
    @earthenergyhex 2 года назад

    I would like to see how the generator is connected

    • @camosolarinc7697
      @camosolarinc7697 2 года назад +1

      Good day Sir i have wired a few of the SW invertert systems what are you looking for ? Do you mean the AC wires or the AGS ?

    • @earthenergyhex
      @earthenergyhex 2 года назад

      @@camosolarinc7697 yes both

    • @earthenergyhex
      @earthenergyhex 2 года назад

      @@camosolarinc7697 for load shaving the 4024 manual says to set it to 10A instead of the default setting of 24A, why is that?

    • @camosolarinc7697
      @camosolarinc7697 2 года назад +1

      @@earthenergyhex Well i need to Reply kinda carefully because the SW inverter has a few problems and that is the
      AC support
      Load Shave
      and SOC
      this you can learn on your own but if you live off grid i set them all to DISABLED .

    • @earthenergyhex
      @earthenergyhex 2 года назад

      @@camosolarinc7697 disabled them all? what sort of problems do they present when enabled?

  • @gilbertobocachica3638
    @gilbertobocachica3638 5 лет назад

    Hello
    Nice video, I whould like to know what whould happen if I change the configuration of the stage inverter to 2 stages without flooding, I saw another video and recommended this configuration for better performance in the inverter, the change will be only in the inverter ,what do you think?
    Best regard
    Gilberto

    • @camosolarinc7697
      @camosolarinc7697 5 лет назад +1

      Yes you could change to a three stage setting. As the genset is / should be used as backup for when you have low solar energy. Using the genset to float would be a waste of fuel

    • @cbisolar1996
      @cbisolar1996  4 года назад

      Thank you, Gilberto! For more info on this setup, please give our shop a call at (403)-358-7762 or email at sales@cbisolar.com, one of our professionals would be happy to assist you!

  • @bambino3162
    @bambino3162 2 года назад

    I am getting a LOW VOLTAGE WARNING . I have 8 RENOGY 12v 200 ah gel batteries which I checked and are better that ok. I got AN OUTBACK FLEX 80. When I turn off the inverter the voltage come back up, but if it ON BUT STILL NOT USED voltage goes down. Can anyone please help_

    • @camosolarinc7697
      @camosolarinc7697 2 года назад

      yes please check your batterys thay sound low or junk

  • @TAGUPNBLUE
    @TAGUPNBLUE 4 года назад

    How do you chew on your fingernails thumb first finger and middle finger or middle finger first finger and thumb

  • @theblueboyworld4884
    @theblueboyworld4884 3 года назад +1

    El peor inversor que se pueda comprar en un mes ya llevo tres veces que viene el técnico a programar ☠️, si no le pones el módulo de internet tendrás problemas con la sincronización de la bateria. Compre otras marcas me lo agradecerán 🙏