Redundancy of Valves- It is impossible to identify voting of the valves without checking Fail Action

Поделиться
HTML-код
  • Опубликовано: 27 авг 2024
  • Redundancy of Valves- It is impossible to identify voting of the valves without checking Fail Action
    The same configuration may become 1oo2 or 2oo2 depending on Failure Action of the Valve.
    There can be different Configurations:
    A. Fail Close and Normally Open Valves:
    a) 1oo2: Better Safety
    b) 2oo2: Better Availability
    Combination of these two configuration provides both better Safety and Better Availability.
    B. Fail Open and Normally Close Valves:
    a) 1oo2: Better Availability
    b) 2oo2: Better Safety
    Combination of these two configuration provides both better Safety and Better Availability.
    Choose your preferred option based on process condition.