Steel Calculation for Two way slab simple technique | BBS for two way slab in Tamil | TCT

Поделиться
HTML-код
  • Опубликовано: 27 авг 2024
  • whats app - wa.me/91701055...
    Telegram link - t.me/joinchat/...
    Estimation of steel for one way slab simple technique BBS for one way slab
    • Estimation of steel fo...
    Two way Slab & One way Slab - Difference | Load distribution from Slab to Beam in Tamil
    • Two way Slab & One way...

Комментарии • 63

  • @funnycrabs1940
    @funnycrabs1940 8 месяцев назад

    Good explanation bro keep it and we need more information for BBS Calculation

  • @g.g.construction
    @g.g.construction 4 года назад +4

    Useful information bro

  • @sutheesh0534
    @sutheesh0534 3 года назад +1

    Excellent information brother. Thank you so much.

  • @smartsakthi5199
    @smartsakthi5199 4 года назад +4

    4.38 minitus la...... Slab oda Crank Height ah calculate pannum bothu cover 15mm thana minus pannaum.... Beam ku thana 25 mm cover varum bro 😉

    • @manisivan964
      @manisivan964 Год назад

      Ipo elam beam ku 30 mm cover & slab 25 mm cover kudukuraga @125 mm thickness slab size ku... For slum board building 🏢

  • @aravindhpandiyan8683
    @aravindhpandiyan8683 4 года назад +2

    Sir Vaasthu pathi oru video podunga..

  • @Civillivic
    @Civillivic 4 года назад +2

    Vera level bro 😎

  • @the_shadow000
    @the_shadow000 4 года назад +3

    main bar ku span 6000mm eduthom , cutting length ku span 4000mm edukurom, why?
    Distribution bar ku span 4000 edukurom , cutting length span ku 6000 edukurom, why? can u explain

  • @vinothgovindaraj5405
    @vinothgovindaraj5405 4 года назад +2

    10:59 minutes laa no of bars double la poodurikika ( = 7 + 7 ) in top bar. Athu yen konjam puriyala konjam sonna Nalla irukum brother....

  • @ArunKumar-tu5jb
    @ArunKumar-tu5jb 2 года назад

    Hi . Really good... Can you put a video for U bar slab please

  • @siva4456
    @siva4456 3 года назад

    Distribution barod crank height H find pannum pothu main bar minus paitu then distribution bar oda half dia thaana edukanum?

  • @dnk.sbt25
    @dnk.sbt25 3 года назад

    Easy for understanding bro..🔥

  • @abushalihahamedmydeen2244
    @abushalihahamedmydeen2244 Год назад

    Nice

  • @aravinds8164
    @aravinds8164 3 года назад +1

    Anna extra bar na curtailment aah??

  • @d.nataraj6812
    @d.nataraj6812 2 года назад

    Two way slab ku shorter span la mattum crank pannanum neenga eppadi longer span la eppadi crank panna soldringa

  • @ajithkumarsm8457
    @ajithkumarsm8457 3 года назад +1

    Top extra bar length L/4 thane varum

  • @nareshrao7399
    @nareshrao7399 4 года назад +1

    bro while we are adding 1d for 45 degree crank ... why we are multiplying 1d along with 2?

  • @rdsbuilders1283
    @rdsbuilders1283 3 года назад

    inches use panunaa practicalaa apply panna inum easyaa irukum bro...

  • @Kiruthi26.
    @Kiruthi26. 3 года назад

    Thanks brother 😁

  • @nihalnih6187
    @nihalnih6187 3 года назад

    Thank u so much bro ❤️

  • @user-qd6oo8tq4i
    @user-qd6oo8tq4i 2 года назад

    top extra distribution ok,but top extra main bar is not given sir,anyway information is very usefull sir..thank you...

  • @civilkarthik97
    @civilkarthik97 3 года назад

    super sir 👌

  • @NaveenKumar-do9rk
    @NaveenKumar-do9rk 4 года назад

    Bar bending schedule for footing and coloumn podunga bro

  • @selvamm4101
    @selvamm4101 4 года назад

    Sir, why we are taken larger value of span as ly and smaller value of span lx....

  • @elavarasanambedkar8805
    @elavarasanambedkar8805 3 года назад

    Super bro

  • @panneerselvam4161
    @panneerselvam4161 4 года назад +1

    Sir corner la beam end iruku. Ippo development length 40d solringa. Athavathu 40*12-480mm. Examble corner beam size width 300mm iruku na epdi 40d formula use agum? My tout sir. Atha mathiri centre la beam 300mm iruku.so appavum 40d vacha beam thandi atutha slab area ku pogum la.pls tell me

    • @tctassociates
      @tctassociates  3 года назад +1

      development length beam mudium bodhu bend panni column kulla dha viduvom next slab ku pogadhu

    • @ayyappans3026
      @ayyappans3026 2 года назад

      You are correct. Why should we calculate Dia here? Need only developmental length. It should be 40 * 2

  • @dineshrk9415
    @dineshrk9415 4 года назад +2

    In two way slab no distribution bars .all are called main bar

    • @tctassociates
      @tctassociates  4 года назад +2

      Yes you are right. Thanks for giving feedback. yes, Technically both are main bars. to differentiate the direction i used the term distribution

  • @muralidharan2972
    @muralidharan2972 3 года назад

    Sir footing and column distance calculation yappadi sir analysis pannuruthu sir,please solluga sir

  • @ranjith.n8334
    @ranjith.n8334 4 года назад

    Bro H find pandrathuku 25mm 25mm cover minus pandringa OK but half Dia half Dia ethuku epadi nu puriyala so please could you explain

  • @muthusamypandi9660
    @muthusamypandi9660 4 года назад

    Where main bars need to place, bottom or top. How to place extra top bar.

  • @dhanraj.s7003
    @dhanraj.s7003 2 года назад

    Bro extra bar details explain pannuga doubt ah iruku

  • @mohamedrashid5859
    @mohamedrashid5859 2 года назад

    Top extra bar la
    no.of bar ~no.of main bar nu one way slab la sonninga bt itula vera formula use panringa
    Rendukum orei formula va illa vera vera formulas use pannanuma
    Plz reply me brother

  • @senthilnathan3040
    @senthilnathan3040 3 года назад

    Why we are adding +1 to find no of bars??

  • @bharathi.r3183
    @bharathi.r3183 2 года назад

    Anna oru house plan pottu tharanglaa

  • @prakashsahana9614
    @prakashsahana9614 4 года назад

    Nice video bro... 🥰😍

  • @Mr.Engineer-m6s
    @Mr.Engineer-m6s 4 года назад

    Doing good job

  • @prabuchinna4767
    @prabuchinna4767 3 года назад

    Super information bro...
    1 doubt ...?
    Cutting length formula'la develoing volue (40) consdant'a....?
    And +(0.42 H) idhula 0.42 consdant volue'va....
    Pls explain this doubt .....?
    Thanks...

    • @mrcool8368
      @mrcool8368 2 года назад

      Indian Standard value 0.42xD
      D=height

  • @manimaran.muthumari7085
    @manimaran.muthumari7085 2 года назад

    Bro for 2 way slab 2(0.42H) illaya bro because 2 side Crank irukumlaaa bro

  • @lovleysuren2671
    @lovleysuren2671 4 года назад +1

    Bro two way slab ku excel sheet upload panuga bro......

  • @DANIELA-pu2no
    @DANIELA-pu2no 3 года назад

    Bro two way slab ku mattum than bar bending varuma one way slab ku varatha

    • @tctassociates
      @tctassociates  3 года назад

      need to do for all steel work in all members

  • @wiselychristober9540
    @wiselychristober9540 2 года назад

    Two way slab la enna main, distributor , long short ellam ? Two way la rendumae main bars than.

    • @tctassociates
      @tctassociates  2 года назад

      Thank you for your valuable feedback

  • @puneithjain6815
    @puneithjain6815 2 года назад

    Crank length =1.42*H

  • @vinothvino5862
    @vinothvino5862 2 года назад

    Romba long explain pandra. Short a explain pannunga

  • @abdulkhayum9065
    @abdulkhayum9065 2 года назад

    subtitle please

  • @HEYDAYBUILDZ
    @HEYDAYBUILDZ 4 года назад

    Nice