Important points to check on RMC Batch Report | For all engineer and supervisor

Поделиться
HTML-код
  • Опубликовано: 4 сен 2020
  • Hello friends,
    In this video I have explained in detail the things that need to be checked after receiving RMC on site on the batch report. From mix proportion to batch size, from moisture correction to admixture dosing this video will clear all your doubts about RMC.
    If you liked this video please share it with your friends and subscribe to my channel for more videos like this.
    Connect with me on Instagram : @furqan.zari
    #RMC #Concrete #CivilEngineering
    what is rmc batch sheet
    how to read rmc batch sheet

Комментарии • 86

  • @hz8200
    @hz8200 3 года назад

    Wow..touched all points well. Thanks for sharing bro...keep posting more.

  • @hakemkhan3165
    @hakemkhan3165 3 года назад

    Omg ..sir mujhe ajtak nahi samjha tha k is me Kya check kiya jata ha...ab mere sare doubt's clear hogyae..thank u sir...❤

  • @litusahu3755
    @litusahu3755 3 года назад

    God bless you and your family 💖

  • @rahidmullas4575
    @rahidmullas4575 3 года назад

    bhai ek number video

  • @badalgallery
    @badalgallery 3 года назад

    Learned new thing..
    Thax

  • @dhanashreesathe4242
    @dhanashreesathe4242 11 месяцев назад

    Good Work

  • @skumar1014
    @skumar1014 3 года назад +4

    Good work. Looking forward to seeing more of your videos. Please ensure that it is not the usual stuff put out by various other youtubers.

    • @EverythingCivil
      @EverythingCivil  3 года назад +1

      Yes sir. that what m here for. To show what others are not showing you can check my other videos. Keep supporting. Thanks 🙏☺️

    • @adrielbode6995
      @adrielbode6995 2 года назад

      I dont mean to be off topic but does anybody know of a tool to get back into an instagram account?
      I somehow forgot the account password. I would love any assistance you can offer me

    • @finleycorbin8596
      @finleycorbin8596 2 года назад

      @Adriel Bode Instablaster :)

    • @adrielbode6995
      @adrielbode6995 2 года назад

      @Finley Corbin Thanks so much for your reply. I found the site through google and im waiting for the hacking stuff atm.
      Takes a while so I will get back to you later with my results.

  • @AdilKhan-zg7jy
    @AdilKhan-zg7jy 3 года назад

    best video sir,

  • @anu_Malhotra_Bathla
    @anu_Malhotra_Bathla 7 месяцев назад

    My god. It's so helpful

  • @shivajipatule8983
    @shivajipatule8983 3 года назад

    Very nice information boss outstanding 👍👍

  • @amolramteke1424
    @amolramteke1424 3 года назад

    Helpful vidio for me

  • @sumangupta1938
    @sumangupta1938 Год назад

    Nice

  • @litusahu3755
    @litusahu3755 3 года назад

    Thanks 👍

  • @umanggupta5333
    @umanggupta5333 3 года назад

    good for civil

  • @AsifKhan-sr4tf
    @AsifKhan-sr4tf 3 года назад

    Thanks

  • @saikatnayak5673
    @saikatnayak5673 Год назад

    Please made a video briefly describe on Batch sheet ..

  • @feedmyego8874
    @feedmyego8874 10 месяцев назад

    hi, is there a maximum limit of using fly ash? my contractor recently bought concrete from RMC for M25 in which cement 224 kgs, msand 824 kgs, aggregate 1090 kgs, fly ash 97 kgs per 1 mcube.. are these numbers fine for M25? thanks.

  • @modassariqbal306
    @modassariqbal306 3 года назад +1

    Its very informative video sir.. thanks...sir 1 video ek RCC slab built-up area ka work order kaise banate hai sir...and most important sir k payment ka stage kaise banate hai contractor ko payment slab by slab and step by step kaise kiya jata hai hai

    • @EverythingCivil
      @EverythingCivil  3 года назад +1

      Yes broo lined up hai ye video bohot jaldi ayegi.

    • @EverythingCivil
      @EverythingCivil  3 года назад +2

      Video agayi apki .
      Labor rate on built up basis
      ruclips.net/video/vML108v5cA0/видео.html
      Builtup area calculation and payment stages
      ruclips.net/video/rKnzi_UMjcs/видео.html

  • @kawtikwarakshaysatishrao5984
    @kawtikwarakshaysatishrao5984 2 года назад

    konsa software hai quantity nikel ne ke liye

  • @aniketmaurya2897
    @aniketmaurya2897 10 месяцев назад

    site pe kya check karate h batch sheet me

  • @onlineodisha9992
    @onlineodisha9992 2 года назад

    Plz described variation formula

  • @SohailShaikh0313
    @SohailShaikh0313 Год назад

    Batch report me cement, aggregate, water aur admixture ka kitna error permissible hota hai

  • @pankajRana-cs8io
    @pankajRana-cs8io 3 года назад

    Awsm sir really awsm. Bada acha laga apka yeh video. Mai chata hu sir aise he aap or videos banake plz share kare batching plant mai joh bhi grade design ko leke fir uske baad batching size. May be sir mai aise samja na pa rha hu kya kehna chata hu. But sir maan lo cement humne 1m3 ke liye 390kg liya as for in lab design . Or yeh pqc ke liye hai. Uske baad maan lo humara batching size hai 90m3 toh sir apki video mai pata chala muje kitna hona chayeh woh. Yahn tak samj aaya muje but internly agr aap or ache se 10mm 20mm 30mm sand admixture ko leke videos agr lambi ban jae no worry but ache se or samja dijeyh plz rqst hai sir apse. har ek ek baat plz share sir rqst hai.
    Thank you sir🙏🙏🙏.
    Pankaj rana🙏

    • @EverythingCivil
      @EverythingCivil  3 года назад +1

      Thanks dear..means a lot. I always make videos for my viewers. Will try this one too.👍

    • @pankajRana-cs8io
      @pankajRana-cs8io 3 года назад

      @@EverythingCivil okay sir but its my honour to see of your making videos more nd more only for the newer students. Thank you so much.
      But sir plz muje material department ko leke kaafi kuch sikhna hai plz help me.
      Thank you sir.
      Pankaj rana.

  • @mridulakrishna2586
    @mridulakrishna2586 Год назад

    Sir ye engineer site pr contractor se le sakte hai kya

  • @chaitanyakulkarni3546
    @chaitanyakulkarni3546 3 года назад +1

    Sir , RMC quality engineer me career income growth acchhi hoti h kya ? Site engineer ke comparison me ??? Plz respond sir

  • @vipulchoudhari9233
    @vipulchoudhari9233 3 года назад

    Sir m25 ka bhi ek banao

  • @amarpc3532
    @amarpc3532 3 года назад

    Bro aap moisture correction ke baare me bata sakte kya barish ke season mai design mix mai kaise change karne ka

    • @EverythingCivil
      @EverythingCivil  3 года назад +1

      Apko uske liye water absorption test perform karna hoga aggregate ke upar.

    • @amarpc3532
      @amarpc3532 3 года назад

      @@EverythingCivil ha sir o hi tumare paas video hai kya aur dusra chija hai clear the concept

    • @EverythingCivil
      @EverythingCivil  3 года назад +1

      Thik hai brother my try karta hu on site ya paper pe apko show karta hu koi vidoe me.

  • @surajkhobragade965
    @surajkhobragade965 3 года назад +1

    Hello sir .
    I have a questions ..
    Why batch a more quantity of materials than required ??
    & what is a limit of it's variation ??

    • @EverythingCivil
      @EverythingCivil  3 года назад +1

      To be on the safer side so that strength is achieved.. variation is usually under 1%

    • @surajkhobragade965
      @surajkhobragade965 3 года назад

      Thanks u sir for your kind information🙏

    • @arunverma7578
      @arunverma7578 2 года назад

      How can it be calculated for whole batch?

  • @pritamrawat7031
    @pritamrawat7031 3 года назад

    kindly update us how to confirm the variations in batch report are in permissible limits .... ASAP

  • @batchingplant5735
    @batchingplant5735 2 года назад

    Sir Schwing Stetter cp-30 ka 0.5 ka plant h uska painal ka video bnaye plz pura contectar ki jankari plz

    • @EverythingCivil
      @EverythingCivil  2 года назад

      Sir Im not working in a plant. Im actually on site.

  • @faizahmad3423
    @faizahmad3423 2 месяца назад

    Concrete retarding time mostly 3 hours hota h na sir ? You are saying 4 hours.??

  • @sankalpconstruction6126
    @sankalpconstruction6126 3 года назад

    PLZ SEND PDF COPY OF THIS BATCH REPORT.....Nice explanation sirji...

    • @EverythingCivil
      @EverythingCivil  3 года назад +1

      Okay sure share ur email

    • @alyssacuray500
      @alyssacuray500 3 года назад

      Good day sir! Can I have a pdf copy of this? Thank you.

  • @virendarprajapati5303
    @virendarprajapati5303 3 года назад

    Sir precentage ka पर्मुला

  • @nirmanconcret2918
    @nirmanconcret2918 2 года назад

    Main bhi RMC Mein 15 Sal se hun

  • @SomnathMondal_
    @SomnathMondal_ 2 года назад

    You are working in ACC LIMITED??
    I AM ALSO WORK IN ACC , PLANT - NS43

  • @2907Prashantyerunkar
    @2907Prashantyerunkar 3 года назад +1

    manufactured sand as per your video 808 x 6 = 4848 but your state says 4703 ??

    • @pavanpgowda6693
      @pavanpgowda6693 2 года назад

      It's completely wrong🙏🏽
      Brother plz don't update these kind of videos

    • @veekshithrai1274
      @veekshithrai1274 Год назад +1

      The mix design will be on SSD (saturated surface dry) condition. The M- sand will have a water aborsbtion of 3-4% which will be considered in the mix design. In the batch sheet shown, the sand is fully dry or 3% of water is required to attain SSD condition. So it will take 3% less sand and in that place it will take water which will be absorbed by sand.
      Note: Water given as 160ltrs is Free water. Whuch will be completely available for cement in concrete.

  • @muzammilmarediya
    @muzammilmarediya 3 года назад

    Slump Ka details rehta he ke nai
    Aur piling me Kitna slump rakhna Chahiye

    • @EverythingCivil
      @EverythingCivil  3 года назад

      You have to adjust the slump by maintaining the admixtures dosage. For piling 150-180mm is sufficient.

    • @muzammilmarediya
      @muzammilmarediya 3 года назад

      @@EverythingCivil we use 180 to 220
      Because concrete get chocked in tremi

    • @EverythingCivil
      @EverythingCivil  3 года назад

      That is also ok

  • @surajsirndikadhara7725
    @surajsirndikadhara7725 Год назад

    tm loading ka software recording send dale

  • @binayaksamanta863
    @binayaksamanta863 3 года назад +1

    Design quant. Of water is 160kg so for 6m^3 it comes 960kg, but it was written 1195kg as required quantity, 😐😐

    • @EverythingCivil
      @EverythingCivil  3 года назад +1

      Yes it's wrong. You caught that error very well. But eventually the batched qty will be 960 kgs only as that 1194 is including the moisture which the system has to know after that it applies percentage and eventually loads water after deducting the extra moisture.

    • @hakemkhan3165
      @hakemkhan3165 3 года назад

      Yes sirji..even I think so..maybe it is including the moisture content.

    • @binayaksamanta863
      @binayaksamanta863 3 года назад

      @@EverythingCivil ok sir got it

  • @kaushikb.suthar6128
    @kaushikb.suthar6128 3 года назад +1

    Sir i want this sheet for sample

  • @enzoken4846
    @enzoken4846 2 года назад +1

    I am getting job in ACC RMC PLANT as a civil Engineer. Is it good?

    • @SomnathMondal_
      @SomnathMondal_ 2 года назад

      Which plant ??

    • @enzoken4846
      @enzoken4846 9 месяцев назад

      ​@@SomnathMondal_ I am in North now it's been a year now ❤

    • @enzoken4846
      @enzoken4846 9 месяцев назад

      ​@@SomnathMondal_you also working in acc ?

  • @kirankumar-ir5ir
    @kirankumar-ir5ir 3 года назад

    Acc company design may be scc

    • @EverythingCivil
      @EverythingCivil  3 года назад

      Yes how u know

    • @kirankumar-ir5ir
      @kirankumar-ir5ir 3 года назад

      @@EverythingCivil acc company has been mentioned on terms and conditions in below design

  • @nirmanconcret2918
    @nirmanconcret2918 2 года назад

    Sewing starter Ka Aisa batch report nahi hota hai

  • @naveensrivastava8229
    @naveensrivastava8229 3 года назад

    Plat wale kuch edit bhi kar deta hai RMC Mai... Mujhe kuch gadbad lagta mere plant pe.

    • @EverythingCivil
      @EverythingCivil  3 года назад

      Ap personally roundup karo..bina bataye tab sab clear ho jayega..apko pura right hai.

    • @naveensrivastava8229
      @naveensrivastava8229 3 года назад

      @@EverythingCivil thnx sir.

  • @mukeshkryadav2485
    @mukeshkryadav2485 3 года назад

    13 minutes hoga bro

  • @prathameshdhumal3659
    @prathameshdhumal3659 Год назад

    WRONG!!
    Bhai galat hei tumhara Water/Moisture Content ka Explaination,
    The moisture content of an aggregate is expressed as: If the moisture content is positive, the aggregate has surface moisture and will contribute water to the Concrete, while if the moisture content is negative the aggregate is air dry to some degree and will absorb Moisture/Water from the Concrete.

  • @nirmanconcret2918
    @nirmanconcret2918 2 года назад

    Duplicate batch report

  • @batchingplant5735
    @batchingplant5735 2 года назад

    Nice