Это видео недоступно.
Сожалеем об этом.

Mahlkonig Maintenance | E65S GbW and E80S GbW Menu Navigation for Diagnostics

Поделиться
HTML-код
  • Опубликовано: 20 окт 2023
  • In this video, John demonstrates how to navigate the GbW menu for service and diagnostics.

Комментарии • 4

  • @dorschn89
    @dorschn89 Месяц назад

    Can you tell me what the numbers in mm are at the top of the display? Is that something to do with the grind size or the burrs?
    Thanks!

    • @primacoffeeequipment
      @primacoffeeequipment  Месяц назад +1

      It is a reference to help guide you back to the programmed grind setting in case the adjustment collar is moved.

  • @Andrew-sj1fm
    @Andrew-sj1fm 5 месяцев назад

    Hi, I recently changed the burrs on my e65s gbw. Do you know how to reset the burr health? Thanks

    • @primacoffeeequipment
      @primacoffeeequipment  5 месяцев назад

      The procedure requires entering the service password: 9512867, then go to Service ----> Confirm Service Reset Burr Health. This will remove the "Service Required" message that pops up on the main screen. You can go into the statics menu and reset the Kg count as well. This does not require entering the service password.