Garage and Garden Electrics

Поделиться
HTML-код
  • Опубликовано: 18 окт 2024
  • ХоббиХобби

Комментарии • 96

  • @colinfenton
    @colinfenton 6 лет назад +10

    With outdoor sockets I use plumbers mate putty around the screws that hold the socket back to the wall, as you tighten the screws up the putty will force around the screws sealing the hole. Plumbers mate doesn't dry up so will always seal, I know it sounds daft to use plumbers mate but it's just putty. Quality job as always, keep them coming. Col.

  • @GSHElectrical
    @GSHElectrical 6 лет назад +3

    A must watch channel keep up the great work Gaz

    • @MyTrustedElectrician
      @MyTrustedElectrician  6 лет назад +1

      Thanks Gaz. I was just watching your R2 testing for lighting circuits. I've never in my life done any R2 testing. I feel like I've been robbed 😅 if I was to carry out R2 is there another way to prove polarity?

  • @Cjrelectrical
    @Cjrelectrical 6 лет назад +11

    Nice one breakfast of champions.

    • @MyTrustedElectrician
      @MyTrustedElectrician  6 лет назад +4

      It is indeed. Although I do spend the rest of the day farting like a gooden 😅

    • @Cjrelectrical
      @Cjrelectrical 6 лет назад +2

      My Trusted Electrician - Carshalton, Wallington and Coulsdon HaHa 😂 second that.

    • @PCH456469871278
      @PCH456469871278 5 лет назад

      @@MyTrustedElectrician can you record these too? im training

  • @craigdowns5247
    @craigdowns5247 6 лет назад +2

    Really great video love the instructional nature of your videos please keep them coming

  • @PlymouthSparky
    @PlymouthSparky 6 лет назад +10

    Breakfast sorted, winters here time to get the work trousers out fella😀✌️. Good educational, entertaining video, love it. Cheers Luke.. p.s leave the sweeping up to the chippies.

  • @Rosscoff2000
    @Rosscoff2000 5 лет назад +4

    My solution for lights on pebble dash is to use mouse mat material - the 5mm thick some neoprene sort. It's waterproof and takes up the uneven gap.

  • @sparky9282
    @sparky9282 6 лет назад +2

    From one electrician to another, great work!

  • @jamesdaly4040
    @jamesdaly4040 6 лет назад +1

    I have it on good authority that it's in case of condensation that they recommend drain holes, great job as usual good for apprentice to see a proper tradesman at work

    • @stevenskillern1477
      @stevenskillern1477 6 лет назад

      You do indeed have it on good authority regulation 522.3.2

  • @peterg.8245
    @peterg.8245 5 лет назад

    Love seeing family in videos it really humanizes you

  • @faridjoshan2823
    @faridjoshan2823 2 года назад

    Nice video and nice work your work is very important in network section

  • @DanSeaber-Shinn
    @DanSeaber-Shinn 6 лет назад +2

    Nice way to join the IP Socket and Spur mate!! Top video as always! 🙌🏻🙌🏻

    • @MyTrustedElectrician
      @MyTrustedElectrician  6 лет назад

      Thanks mate. I've had a few comments questioning why I earth the galv nipple between the boxes. Is it that weird? I'd feel wrong to not earth something metallic I've run cable through 🤔

    • @DanSeaber-Shinn
      @DanSeaber-Shinn 6 лет назад +1

      I’d be the same as you mate, earth everything! 😂

  • @AX12CON
    @AX12CON 6 лет назад +22

    When drilling outside from inside, take it off hammer, yes it takes longer, but hammer most of the way until the last 10 percent, then take it off, you'll never have a blowout

    • @rudyalec3346
      @rudyalec3346 3 года назад

      Sorry to be off topic but does anybody know of a way to get back into an Instagram account..?
      I stupidly forgot the login password. I would love any assistance you can give me.

    • @dakotastephen5273
      @dakotastephen5273 3 года назад

      @Rudy Alec Instablaster =)

    • @rudyalec3346
      @rudyalec3346 3 года назад

      @Dakota Stephen thanks so much for your reply. I found the site through google and Im trying it out now.
      Looks like it's gonna take quite some time so I will get back to you later with my results.

    • @rudyalec3346
      @rudyalec3346 3 года назад

      @Dakota Stephen it worked and I now got access to my account again. I am so happy:D
      Thank you so much you saved my ass!

    • @dakotastephen5273
      @dakotastephen5273 3 года назад

      @Rudy Alec happy to help xD

  • @paulteasdale7112
    @paulteasdale7112 6 лет назад +7

    Great video as always. Just one thing, you can get black ip67 glands for Flexi conduit, much neater looking! Top work though mate.

    • @MyTrustedElectrician
      @MyTrustedElectrician  6 лет назад +3

      You can indeed sir. You may be referring to the white 20mm stuffing gland I used for the water feature. It was all I had on the van and I hadn't planned on there even being a water feature on site. It was supposed to be something the customer was thinking of getting in the future.

  • @curtisj2165
    @curtisj2165 6 лет назад +1

    Those lights on the side of the garage looks nice

    • @MyTrustedElectrician
      @MyTrustedElectrician  6 лет назад

      The customer supplied them. They're LED. Not a bad light to install.

  • @heliman85
    @heliman85 6 лет назад +1

    Nice video and nice work. I have just subscribed mate. Also I have been saying the same thing for a while about the Wiska boxes. I even sent them a message about this. They have finally released one with a rear entry! It's the Wiska 407 combi box, dimensions are 95mm x 95mm x 60mm, so it is only slightly larger than the 308 box that you have used in this video. The 407 box has two rear entries at the top corners, this allows you to still use the mounting bracket, as that requires the middle part to lock into and so it couldn't be centre entry at the rear if you know what I mean, it also has a 25mm threaded entry unlike the 308 box which only has 20mm threaded entries.

  • @no_short_circuit
    @no_short_circuit 6 лет назад +4

    Thanks again for a great video. As an electrician's mate I'm interested in the tests, continuity, IR, Zs etc.....any chance of a bit more of that?

  • @chrisgodden30
    @chrisgodden30 5 лет назад

    "Toilet tubes" 😂😂 that's what I'm getting on the front of my house ... now I will forever think of them as toilet tubes haha cheers. Love the breakfast gonna try that tomorrow morning 😀

  • @stevenskillern1477
    @stevenskillern1477 6 лет назад +1

    Great idea spacing the accessories off of the wall definitely helps to comply with regulation 522.9 which a lot of people don't generally considered.

  • @donnierobertson3088
    @donnierobertson3088 5 лет назад +1

    Nice job

  • @Oldgamingfart
    @Oldgamingfart 6 лет назад +1

    I have outside garage/ porch lights but they are all controlled by a single Dusk-to-Dawn Sensor (photocell), so they only come on from, well..dusk to dawn!
    On saying that, I do like the Timeguard units as I have the exact same one to get the towel radiator nice 'n' toasty before shower time! :D

    • @MyTrustedElectrician
      @MyTrustedElectrician  6 лет назад +2

      I actually prefer a little of both but as you can imagine it's expensive to install a timer and photocell for 1 circuit.
      It's actually what I install a lot of for commercial properties. The photocell will turn lights on when it's dark, but the timer will ensure that they're not running all night. This will increase the life span of the lights/lamps and save money on the electric bill.

    • @sinista6536
      @sinista6536 5 лет назад

      My Trusted Electrician - Carshalton, Wallington and Coulsdon www.wickes.co.uk/Masterplug-Weatherproof-Dusk-to-Dawn-Timer-Switch---Grey/p/117864 These are fantastic for controlling outdoor lighting circuits. I mounted one on the back of the garage for all the garden lighting and one on the front of the house for the soffit lighting. Two dials on the inside, one for light sensitivity and the other one for the timer (2hr, 4hr, 6hr, 8hr or dusk TIL dawn)

  • @chrishill2185
    @chrishill2185 4 года назад

    What a legend, keep up the brilliant videos matey and the banter :-)

  • @Webbster77
    @Webbster77 5 лет назад +2

    Did you not have the end for the copex instead of that white gland pal? You know what I mean don’t you?

  • @kangtheconqueror
    @kangtheconqueror 6 лет назад +1

    Thanks for the video Buddy. Nice job.

  • @joeeaton5486
    @joeeaton5486 6 лет назад +1

    Great video 👍 keep them coming!

  • @DaddyBear3000
    @DaddyBear3000 6 лет назад +1

    Quality jobs, nicely done buddy. Will definitely be giving the hash browns butty a crack lol.

  • @tomballinger8984
    @tomballinger8984 4 года назад

    Random one... and probably quite a stupid DIYer question - how are the boxes jointed together - screw thread or some fancy way of setting it up!? I normally run a short length of conduit between them, resulting in a 50mm gap - but butting them up looks much much better - ta!

  • @shilks8773
    @shilks8773 5 лет назад +1

    Have you completed the Electricians Broom handling course and completed a risk assessment for Broom related injuries (I guess mostly physiological).

  • @doctorelectric470
    @doctorelectric470 6 лет назад +4

    can you run through that bit at the end with the big wooden thing? Haven't worked it out yet!

    • @MyTrustedElectrician
      @MyTrustedElectrician  6 лет назад +1

      Sure which wooden thing? The garage?

    • @doctorelectric470
      @doctorelectric470 6 лет назад +3

      @@MyTrustedElectrician that big thing with the bristles on the end, what is that?

    • @MyTrustedElectrician
      @MyTrustedElectrician  6 лет назад +2

      @@doctorelectric470Oh that is a new contraption that's still in the early testing stages. It's not been released yet for purchase. It's supposed to help clean floors but I don't think it'll take off personally.

  • @JayTheSparky
    @JayTheSparky 6 лет назад +1

    Qualify video mate, the hash brown in the McMuffin is the only way to go!
    What I like about your videos and other electricians vlogs I follow are it’s all the real life situations such as not having a Whiska box on the van 🙄🤦🏻‍♂️ Happens all the time and it’s a dash to find a local wholesaler!
    I love that fact it’s not just our wholesaler who gives you the wrong gear and you don’t realise until you get to site!🤬
    The Whiska back entry thing is so true! Would make like so much easier like you say every outside flood light or future outside light feed we run we have to do the same, spin a hole out the back and then fill with CT1 to maintain the IP rating.
    The customer doing their own lights and bang💥🤣 Bread and butter work to a spark that. Keep up the good videos mate, quality work 👍🏻

  • @Hiccup77
    @Hiccup77 6 лет назад +1

    8:39 A stuffing gland, ran out of kopex glands on the van bud. It's great to see the additional thought of fitting spacers to the back boxes. I know the circuit is already protected by an RCD, but can you also fit an RCD switched socket outlet for the outside? Hopefully? Under fault conditions you will achieve discrimination and not trip the RCBO in the ccu?

    • @stevenskillern1477
      @stevenskillern1477 6 лет назад +2

      Hi Hiccupp77, you wouldn't put 2x RCDS like you said for discrimination reason (selectivity under the 18th 536.4.1.4) we wouldn't be able to rely on "hopefully" right?

    • @MyTrustedElectrician
      @MyTrustedElectrician  6 лет назад +1

      Haha, I have bloody kopex glands falling out my ears on the van. You get 10 in every bundle and I rarely use them all. It's flex and so I use a stuffing gland. I don't believe kopex is water tight although I may be wrong. Also I need to secure the flex from flying out of the box if somebody was to pull it at the other end 😉

  • @mrthugduck3782
    @mrthugduck3782 6 лет назад +2

    Hi, what glands are you using for the weatherproof boxes? It looks like it saves a lot of time. Thank you

    • @MyTrustedElectrician
      @MyTrustedElectrician  6 лет назад

      I call the glands 'stuffing glands' the wholesaler refers to them as nylon compression glands'. shame I only had a white one aye

  • @braedenbedford9055
    @braedenbedford9055 6 лет назад +1

    Ahahaha I'm a first year and came across this video , thought I was the only one who threw the hash brown on the sandwich 😂 my journeyman always makes fun of me for that lol , good video tho keep it up

  • @johnstancliff7328
    @johnstancliff7328 5 лет назад

    nothing like starting the day with McDonalds!

  • @spiikemaz
    @spiikemaz 6 лет назад

    What’s the wiring arrangement for the spur, single socket, light and timer in the garage anyone ? Your going from CU on a 20amp radial to the Switched fused spur on the supply side derating to what amp? Then feeding single socket and timer and from the load side? I’m confused, no judgement just trying to vision it in my head? Top video keep um coming !

    • @kamuts7
      @kamuts7 5 лет назад

      Marcus Moore 13A

  • @paullyons4624
    @paullyons4624 6 лет назад +1

    I presume you used wagos to extend one leg of the existing behind the original socket?

  • @charliechimples
    @charliechimples 5 лет назад

    Great vid. Thanks for sharing. 🐵

  • @daron8982
    @daron8982 3 года назад

    You’re not doing any more videos?

  • @mij.londoner
    @mij.londoner 6 лет назад +2

    Quick question
    U had two cables coming down one into the fused spur and one leg in the double socket
    We're both of these flat twin and earth coming from that indoor socket??
    Thanks for the upload

    • @MyTrustedElectrician
      @MyTrustedElectrician  6 лет назад

      Yes, to extend the ring circuit mate. So I could spur oof more then once.

  • @deanmark11
    @deanmark11 6 лет назад +1

    on the loop isnt there supposed to be 2 neutrals also one in and 1 out to next fitting?

    • @MyTrustedElectrician
      @MyTrustedElectrician  6 лет назад +1

      It was the last point mate 👍

    • @deanmark11
      @deanmark11 6 лет назад

      My Trusted Electrician - Carshalton, Wallington and Coulsdon ahh I see thanks mate keep up the good work and videos very informative

  • @neiltrevatt
    @neiltrevatt 4 года назад

    Top entry conduit not good idea how well is that sealed I would bring conduit down to a t box then go either way to socket and spur

  • @brendymalone1
    @brendymalone1 6 лет назад +1

    There is wiska boxes with back entry mate

  • @gazdkw82
    @gazdkw82 6 лет назад +1

    Why did you use the piranha nut? Just to earth the coupler?

    • @MyTrustedElectrician
      @MyTrustedElectrician  6 лет назад

      Yeh, you could argue that it is unaccessible but it's good practice.

    • @gazdkw82
      @gazdkw82 6 лет назад +4

      @@MyTrustedElectrician could you have used a plastic coupler?

    • @AlanLumsden
      @AlanLumsden 6 лет назад

      And expensive!

  • @andrewdnn8253
    @andrewdnn8253 5 лет назад

    Why don't the cable manufacturers insulate the earth wires in your 1.5mm2 & 2.5mm2 Twin & earth? BTW our day to day price for an RCBO is AUD 30ish (GE/Legrand/Hager Schneider is a little more 6kA c curve 6 - 45A)

    • @Adam-vy6nl
      @Adam-vy6nl 5 лет назад

      Andrew @ DNN I know what you mean it’s a pain in the arse

  • @sbmorris2k6
    @sbmorris2k6 6 лет назад +1

    Why us the ring circuit on a type c32 ?

  • @Braadd98
    @Braadd98 5 лет назад

    20m contractors pack would be more suited for that

  • @cprfenom
    @cprfenom 6 лет назад +2

    Why did you decide to use an earth nut instead of a ribbed lock ring? just curious.

    • @MyTrustedElectrician
      @MyTrustedElectrician  6 лет назад

      You could argue that the galv nipple is not accessible but it just feels right to earth it as I have live cables running through it. It's just how I do it.

  • @ericthekingthekingtheking4842
    @ericthekingthekingtheking4842 6 лет назад

    What testing is needed mate After these jobs were completed

    • @MyTrustedElectrician
      @MyTrustedElectrician  6 лет назад +5

      That is a great question!
      So both jobs were alterations/additions to existing circuits and either were in a special location. This means that both can be covered with a simple MWC. However it's worth noting that a MWC does not ask for ring continuity values which I would consider important for work carried out on a ring circuit. I would write these values down in the notes column.

  • @RinkuRR7
    @RinkuRR7 5 лет назад

    good job bro I want this job.plz

  • @johnoreilly7052
    @johnoreilly7052 5 лет назад

    I have been there about 6 times it is a pain

  • @pault4793
    @pault4793 5 лет назад

    if that was a timer spur no need for the extra spur unit

  • @Wikirides20
    @Wikirides20 6 лет назад +1

    Why wouldn’t you just put a cu in the garage ?? With a spare way for the timer ?

  • @handyman8522
    @handyman8522 5 лет назад +3

    I never use plastic sockets or fittings in any out building, garage, shed etc. Two reasons, firstly they are not as tough as metal and secondly and most importantly, if a plastic switch or socket gets covered in condensation you can receive quite a nasty shock from it. This doesn't happen with metal as they're usually earthed and if they get too damp they will knock of the RCD. Of course you can't earth plastic so current can track along the condensation enough to make the socket (or film of condensation) live but not enough to register at the RCD. It drives me mad when I see qualified electricians using plastic in damp out buildings.