INTEX SPA E90 ISSUE RESOVLED UNDER 10 MINUTES!!!!

Поделиться
HTML-код
  • Опубликовано: 6 дек 2018
  • If your having a code E90 appear on your spa control panel here's how i fixed it and i was having this problem first time trying to use it now it's been running better than ever !!!

Комментарии • 135

  • @kellygottsponer4056
    @kellygottsponer4056 3 года назад +4

    THANK YOU!! This simple fix saved me HUNDREDS of dollars in buying a replacement motor or spa! I’m a 52 yr old woman who found the instructions clear & easy to follow. Definitely saving your channel as a resource for future repairs 👍🏻

  • @willcool24
    @willcool24 4 года назад +5

    Fixed my hot tub.i was sure getting madd before I saw your video. Now I'm happy drinking a beer.cheers my brother 💪

  • @sparkyswearsalot
    @sparkyswearsalot 3 года назад +4

    Nicely done video! Thanks for being so clear with the camera work and descriptions.

  • @scottporter6609
    @scottporter6609 4 года назад +6

    This was exactly my problem!! Thank you. After two seasons this was necessary.

  • @theunkownmr.562
    @theunkownmr.562 4 года назад +7

    Thanks for the tips!
    Also, do something about that nasty green water. Add chlorine and some kind of coagulant to get all the nasty suspended solids put of the water.

  • @5Flaash
    @5Flaash 2 года назад +1

    Thanks for the clear instructions. I could feel good flow and was scratching my head for sure. Appreciate you taking the time to share your knowledge.

  • @alainpnz4096
    @alainpnz4096 2 года назад

    Good morning ! Your solution to remove the E90 code is EXCELLENT !!
    Finally, someone has found the solution.
    Big thanks !!
    Alain from FRANCE.

  • @mollyborum7973
    @mollyborum7973 4 года назад +2

    This fixed my tub!!!!!!
    Thank you so much!

  • @thomasreto2997
    @thomasreto2997 4 года назад +3

    Just had one of those come up today....first time....after trying unplug and plug....it came back (with erratic temp reads on screen.....)I will give it a shot tomorrow...thanks for the share😃

  • @vlad1357
    @vlad1357 5 лет назад +3

    Thank you so much, the copper sensor was all full of oxidation. Cleaned out with sandpaper and now working!!!!

    • @letzrepairit5492
      @letzrepairit5492  5 лет назад +1

      Glad that helped you out. I will be doing a video on mine once again soon. Also don't use powdered chlorine.. only liquid chlorine. I have found this messes with the impeller shaft. So I will be doing a video on the motor next. Thanks for watching like & subscribe!

    • @laurieadam6543
      @laurieadam6543 4 года назад

      LETZREPAIRIT so the chlorine granules are no good to use? Had mine for two weeks and keep getting the code e90. Thanks

  • @tgirard123
    @tgirard123 4 года назад +6

    There are two of these sensors. they are 10k passive sensors. Unfortunately this really doesn't fix the majority of the issues with the sensors. They really just wear out. What We need is a replacement sensor (Preferably Stainless steel) that can be adapted into the system. I have seen a few possibilities but haven't found the right one yet. For now, I have one sensor working and rigged a potentiometer for the other one.

  • @deafscotty6246
    @deafscotty6246 4 года назад +1

    This fixed my hot tub!! Only if I empty water out then f
    Refill. E90 showed.. then I did what this RUclips showed. It worked everytime.

  • @DMNBK
    @DMNBK 4 года назад +3

    Worked! Thanks man!!

  • @nickp5321
    @nickp5321 4 года назад +1

    Thanks so much! Out of the box had this issue. This fixed it.

    • @smom3484
      @smom3484 4 года назад

      Me too. We just purchased one, set it up and its having this issue. Sucks.

  • @SimonenaEuropa
    @SimonenaEuropa 3 года назад

    It really works...It was full of limestone. I just cleaned and start again to work. Thank you so much.

  • @tylerlienau7548
    @tylerlienau7548 4 года назад +2

    Great video. I got them to send me a new motor because it had a code. Forgot what code but this might have fixed it! Wish I would have seen this before!

  • @paddyboom122
    @paddyboom122 4 года назад

    I found that those of us that use well water have alot of minerals,so it makes perfect sense that the sensors might corrode. This is the only vid mentioning anything about a sensor..thankyou letz..Dont forget that the pump is the weak point of the entex system..airlock,rotor,leaks..etc...

  • @toddybueno4076
    @toddybueno4076 2 года назад

    this actually worked for me thank you kind sir

  • @hawkevideo
    @hawkevideo 4 года назад +3

    Thank you. I’ll have to try this. Replacing the filters did not work this time.

  • @ZuperZocker
    @ZuperZocker 3 года назад +1

    Mine wasn't dirty, but just the act of taking it all apart either loosened some debris or jostled it just right. Thank you!

  • @ralphrey2442
    @ralphrey2442 4 года назад

    thank so much it fix my problem, after allthis time callin the company is wrok jus tliek you said
    thank you so much

  • @oddsandwindsocks5905
    @oddsandwindsocks5905 Год назад

    Nicely done

  • @bridgettekirk2604
    @bridgettekirk2604 5 лет назад

    Thank you. I just read something that says the system goes bad on 3 to 6 months. And that its $40 to re place the pump over n over. Unless you know how you openit in do something else. But this shows the simple cleaning solution So thank you. I'll be doing this and will post back

  • @Professor_Silva
    @Professor_Silva 4 года назад +9

    This Intex Spa has such a complicated maintenance. It gives me more work than pleasure. What a regret!

  • @JustADream1111
    @JustADream1111 4 года назад +1

    What size is that white nut wrench to take the top lid off ? I misplaced mine may have to order it or think of something else

  • @otkmob
    @otkmob 4 года назад +2

    Dam that’s some cold water 🥶

  • @aldavis2641
    @aldavis2641 3 года назад

    Got in under the warranty and got a new pump, installed but still got the E 90 when the filters were on. Going to proceed with the sensor cleaning and get back with the results. I replaced the impeller shaft of the old pump, with no results as the pump made a lot of noise before it went out. I suspect this will be the final cure.

  • @JGibson512
    @JGibson512 5 лет назад +7

    Had to make sure the unit was filled with water so once we cleaned the sensors (they were clean), we took the filter off by the pump unit and let it run without the filter on it so the water would flow through, and then put the filter on (which was new but wouldn't work by just changing it). You have to make sure all of the air is out of the lines. Back in biz!

  • @marinak8132
    @marinak8132 Год назад

    Thank you. Super👏👏👏

  • @runin1wild
    @runin1wild 3 года назад

    Step by step I think I taken my intex apart 4 or 5 times now doing the pump, had to replace the impeller once already, I know I heard everyone seems to have problems with the shaft breaking, but I’ve had the same shaft since 2015 ( must been a fluke on that part) the magnets and casing crumbled in to piece after 2 years of purchase so I had to buy a new pump but of course not the same as the newer model but still good for parts but expensive. But I seen so many videos and a few have some links to replace the impeller or shaft. Also them temp sensors to. So I guess cleaning them first to see if I can get the code to go away would be my last step! 🤞🏼 And also de-scaling the heating unit it self . But will have to do that manual by hooking up a pump to it with hot water and was going to try de-scaler for coffee makers first!

  • @williamsrmonroe8406
    @williamsrmonroe8406 2 года назад

    Am I correct in assuming there are nuts that fall out when removing the bolts in the housing.

  • @danielocs4259
    @danielocs4259 5 лет назад

    This worked fine! I only removed and reput the two sensors and it started working again.

  • @ramrack6301
    @ramrack6301 Год назад

    Cleaned the sensor and replaced the filters and the pump works. I think my filters may have looked ok but were impeding flow.

  • @juniorkawai6131
    @juniorkawai6131 2 года назад

    Came for the video...stayed for the music.

  • @birgithransom7055
    @birgithransom7055 4 года назад +2

    My unit looks different. I found something that looked like it, but wasn't able to move it at all :-(

  • @ScareHollow
    @ScareHollow 5 лет назад +5

    the other issue with e90 is that your impeller rod inside the pump is broken.. replace it with a brass rod and you'll not get the error either. those things you cleaned are the temp sensors for the heater.. and cause the e95 and e96 errors...

    • @letzrepairit5492
      @letzrepairit5492  5 лет назад +1

      thank you for replying with that input. I did that first changed out the carbon rod. I put in a copper rod that did not do it .. I do know that those are temperature sensor but I believe taking out, all three and cleaning has worked.. strange. The rod i replaced is going out.. We run our spa 24/7 next video i will be pulling out the copper one. any suggestions?

    • @letzrepairit5492
      @letzrepairit5492  5 лет назад

      sorry brass was used.

    • @wilmabarnett1438
      @wilmabarnett1438 4 года назад

      @@letzrepairit5492 Are those temperature sensors or another type of sensor? We took them out and cleaned, both were pretty corroded. The main one cleaned fine, but it still only ran for a very brief before getting the error code again. The second one appeared to have the casing break off of the end while cleaning (with polishing sandpaper). The end now looks like black plastic material. I am guessing that means it's is done for. I have looked for the replacement and can't find it. It runs without the error code while running water through the garden hose into the bottom C port. Also, do you have a video for replacing the impeller rod inside the pump? Thank you so much sharing your wisdom!!!

  • @redstripe6539
    @redstripe6539 4 года назад

    Just took my sensor off and it is black! I am assuming that is very bad. How should I clean it, just with sandpaper? Or is there something else I should be using to clean it?

  • @bastienscenner4631
    @bastienscenner4631 2 года назад

    Merci pour l'information good

  • @wilmabarnett1438
    @wilmabarnett1438 4 года назад +2

    Is that a temperature sensor?

  • @anamariarubiomoreno9848
    @anamariarubiomoreno9848 3 года назад

    What happens if it is continuing to show's E96, and you do not stop de spa ruined?

  • @lorymoniz3802
    @lorymoniz3802 2 года назад

    When I pulled out sensor water starting x coming out. Place it back in but leaking no matter how I try and tighten it. Any advice?

  • @tylerlienau7548
    @tylerlienau7548 4 года назад

    Your welcome for watching. These hot tubes are fucking awesome!!!!!

  • @tomlawson3157
    @tomlawson3157 3 года назад

    Any help on a SimpleSpa SB-B10 E96 error code (2020 model with NO stalk" and if able, what does the E96 mean.

  • @blaze556922
    @blaze556922 4 года назад +3

    Great video but why would you need the caps in the first place?

    • @iconicgirl649
      @iconicgirl649 3 года назад

      To keep the water in the tub when disconnecting

  • @cosmickatamari
    @cosmickatamari 3 года назад

    So you never had to deal with this again?

  • @franck1806
    @franck1806 2 года назад

    hello, you spoke at 2 mn 09 sec about something you show us, but I don't undersdand what it is, could you explain me ? Thanks a lot

  • @elixis2847
    @elixis2847 3 года назад

    If you have a newer model the e90 is a water flow blockage and not pipe. Please don't do this on the purespa PLUS models. This is fixed in the newer ones.

  • @maxreviews3418
    @maxreviews3418 4 года назад +2

    So my filters could just be dirty

  • @tedmartin4882
    @tedmartin4882 4 года назад

    I had E90 code. Pump motor shaft broke after 8 months. Replaced with brass shaft only lasted 10 days

    • @letzrepairit5492
      @letzrepairit5492  4 года назад

      Are you using liquid?... Powered form eats everything!

  • @radekw708
    @radekw708 3 года назад +1

    I think my pump went out, so basically died 1 week after I had it for a year, hehe smart design. Not sure what it is though for sure, when I plug it in and turn on the pump nothing happens, there is a pause and then e90

  • @drdeliciousful
    @drdeliciousful 2 года назад

    Unfortunately the inside of mine does not look like that-no sensor to remove and clean

  • @kingdrako7910
    @kingdrako7910 4 года назад

    What if it doesn't have a sensor

  • @KCEEANDOLIVEAROX
    @KCEEANDOLIVEAROX 4 года назад

    Where did you get the inlet/outlet covers? I can’t seem to find them online...

    • @nopro5433
      @nopro5433 4 года назад +1

      Kasey Mae Taylor they come with the kit when you get it with the hose and all the other little Gizzy’s that come with the tub.

  • @nopro5433
    @nopro5433 4 года назад

    Great video I’m going on two years with mine and actually got a pump replaced warranty or year ago lately the E 90 came on only when I run the heat I cleaned the filters plugged it back in and turned it on it’s fine with filters running as soon as I turn on the heat I will get the E 90 think this could fix the problem or Im thinking my heater is probably fried usually always run the pump on this unit indoors and keep it at 101 then when I want to use it I’ll turn it up a couple hours ahead of time to 104 I have noticed it has been heating quicker than usual lately?

    • @letzrepairit5492
      @letzrepairit5492  4 года назад +1

      I have found using powder chlorine is causing most of these issues. Hope this help's

    • @foxymartin2689
      @foxymartin2689 4 года назад

      Hi i'm having trouble with my hot tub and it's coming on as soon as i put the heat on it goes off in about 5 second with the E90 flashing iv put new filter in it and iv clean the heat sensor wot else can I do to fix it any one with any I dears let me know soon as please thanks

    • @nopro5433
      @nopro5433 4 года назад

      Chris Hall Mine lasted about two years then heater went out as well ended up giving it to a buddy and he used it as a pool I purchased another one about 3 months now I was having this issue as well on my new one and motor seems a little louder on the pump but is working good What I did is loosen the filters to where they’re almost all the way off where you screw them into the tub and that gives a little more airflow that seemed to work recently replaced them and did same thing so I noticed by hitting the breaker on the plug-in cord that resets it and have not had a problem since. I make sure your water is filled to the max line as well I do you believe these last a good two years did replace the pump warranty after one year and that’s probably it for the price can’t really beat it found the best price on eBay through VM distributors. Had in my watchlist for 379 got an offer from seller for 239 after a month being in my watchlist so could not pass that up. I have found best way to keep it chlorinated is the 1 inch tabs one about every two weeks in the little floaty that is included with the kit I really do nothing else Hope this helps 🇺🇸🍻👍

    • @jakedouglas5836
      @jakedouglas5836 2 года назад

      Mine had the safe issue, I found a tip online and swapped the heat sensor that trips out if the black heating element gets too hot, frites it for me

  • @IFollowYeshua
    @IFollowYeshua 4 года назад

    The company changed the design of the sensor and it has an interior thread. The plastic piece comes out but not the sensor. Any thoughts?

    • @letzrepairit5492
      @letzrepairit5492  4 года назад

      Can you send me a picture?

    • @johngamel91
      @johngamel91 4 года назад

      Did you get an answer to this? If not just pull gently on the cord and the sensor will come right out. I have the same as you.

  • @leodanryan966
    @leodanryan966 4 года назад

    It seems pretty cut and dry. We're going to give it a try immediately. Let you know what happens with it. Thanks
    Update: This didn't work for me, I still get e90 error. New filters as well.

    • @pauldukovac6306
      @pauldukovac6306 3 года назад

      Its the pump more specifically the rod inside the propeller inside the pump.

    • @robertleach6339
      @robertleach6339 Год назад

      Need to start using liquid chlorine

  • @tracybreddy8450
    @tracybreddy8450 4 года назад +9

    Just replace the filter no need to do this

    • @leodanryan966
      @leodanryan966 4 года назад +1

      I have brand new filters. I'm trying this. I'm also on my 3rd intex purespa. The heaters always go out, and right now you can't even find a new one to purchase.

    • @randylee6674
      @randylee6674 4 года назад +1

      I also have new filters, still having issue

    • @richardallan455
      @richardallan455 3 года назад

      Me too,the filters seem to have a tough job and cleanining them isn.t easy,hosepipe blast doesn.t work,putting it in the dish washer worries me too much grease and so u need to put it in sepearately,seen one guy drilling into the top of a new filter and refitting it,but unsure what he was trying to achieve.

    • @milothechihuahuabrunetandmommy
      @milothechihuahuabrunetandmommy 3 года назад

      @@leodanryan966 just back wash your pump like you do a pool it will work promise I will have to do a video when I get mine next year

  • @growtiger
    @growtiger 4 года назад

    Where can I get a new sensor? One of the two is completely corroded and inside is exposed.

    • @letzrepairit5492
      @letzrepairit5492  4 года назад

      www.intexdevelopment.com/support/12025/productdetail try this

  • @Chelsealulu100
    @Chelsealulu100 3 года назад

    Did I hear that right? replace the S1 filters after every use? This has to be wrong. Also, my sensors were spotless. This video does not address all the E90 issues.

    • @pauldukovac6306
      @pauldukovac6306 3 года назад

      probably your pump more specifically the rod inside the propeller inside your pump. New pump cost $50 but they are flawed and will have to most likely replace again.

  • @DonBradway
    @DonBradway 3 года назад

    Good news, the sensor's clean. Bad news, the sensor's clean. Looks like a new pump is coming up. Did you encounter any resistance when you replaced the cover? I've got the black wire out of the way and found the channels to the right side, got the piping in line and still have some resistance in getting the cover all of the way down so I can install the screws. Your thoughts?

    • @Chelsealulu100
      @Chelsealulu100 3 года назад

      Did you make sure the channels are lined up in the front of plastic housing? I had resistance too until I noticed the housing wasn't completely straight.

  • @kimberlykerr7370
    @kimberlykerr7370 4 года назад

    Hi,I'm having trouble with the heating button I can turn the hot tub down but cannot turn it up please what do I do.

    • @letzrepairit5492
      @letzrepairit5492  4 года назад

      The control panel is bad . Try and find one online.

  • @jomccormick6880
    @jomccormick6880 3 года назад +1

    When I took sensor out water pour out!

  • @floridachickstinyadventures
    @floridachickstinyadventures 2 года назад

    Unfortunately this did not solve my E-90 error

  • @fernandomre
    @fernandomre 4 года назад

    Don’t you need a GFCI outlet ???

    • @weeral1
      @weeral1 4 года назад

      Not really. A gfci is built into the spas plug. It doesn't hurt to have more safety (well.. One more thing to go wrong i suppose).

  • @peterdurkin3556
    @peterdurkin3556 4 года назад +1

    I have tried everything in the video and still get the E90 code. I cleaned that one sensor really good and even cleaned it with peroxide. I just tried running the hose at max for 5 min and still get the code after turning on in less than a minute. Someone said something about a second sensor. Where might that be? TIA

    • @darebear53711
      @darebear53711 4 года назад

      You might need to take the pump case apart, there is a nylon impellar shaft, and I replaced it with a brass one (can't be magnetic) and it fixed it...

    • @tedmartin4882
      @tedmartin4882 4 года назад

      I had broken pump motor shaft, replaced with brass shaft but that only lasted 10 days.

    • @pauldukovac6306
      @pauldukovac6306 3 года назад

      Same thing happened to me. Have replaced rod 4 times now.

  • @timmytson1
    @timmytson1 2 года назад

    Mine just beeps the whole time

  • @dillonsmom58
    @dillonsmom58 5 лет назад

    Do you keep your filter running 24/7? Or does it shut off automatically?

    • @letzrepairit5492
      @letzrepairit5492  5 лет назад

      I run with a clean filter at all times. The e 90 code might come on hit the reset button turn it on again. You might have to do this once or twice. This works for me . Thx for watching

    • @letzrepairit5492
      @letzrepairit5492  5 лет назад

      I do run mine 24/7 .

    • @richardallan455
      @richardallan455 3 года назад

      @@letzrepairit5492 Thank you but which button is the reset button?

  • @Noxious922
    @Noxious922 4 года назад +1

    As soon as I took the sensor out water came gushing out all over everything

    • @MsSaudm
      @MsSaudm 4 года назад +1

      Yes me too it made a big mess and he does not ever mention that you have to drain it first !!!!!

    • @samuchevres6781
      @samuchevres6781 4 года назад +1

      you are not covering all the gaps

    • @stevejensen1512
      @stevejensen1512 4 года назад +1

      Make sure to remove the filters and put the black rubber caps over the “C” holes. This will stop the water from leaking out when you remove the sensors.

  • @cassiesutherland215
    @cassiesutherland215 4 года назад

    Anyone have a problem with the sensor then leaking after screwing it back in? Not from round the bolt but from the hole where the cord goes through? Going to drain the tub & try again but any advice would be great

    • @johngamel91
      @johngamel91 4 года назад

      Need to make sure the little o-ring seal is in good shape and or still there.

  • @chrisakachuck
    @chrisakachuck 4 года назад +1

    Does this e90 stop it heating up ?

  • @karensedenka5307
    @karensedenka5307 4 года назад

    I unplugged mine, plugged it back in and ran the bubbles for 5 minutes. Then I turned the bubbles off and the pump on. No more error code.

    • @aliceb1690
      @aliceb1690 4 года назад

      This worked for me also. Thanks

    • @15chrispowell
      @15chrispowell 4 года назад

      I seen another video to do this and it worked for me two times, this time iv'e tried it twice and never worked, I've left it off for 5 mins and tried reset again seems ok for now

  • @radekw708
    @radekw708 3 года назад

    My sensors were super clean, e90 when you plug it in, pump doesn't even start, only bubbles

    • @cnewkirk7171
      @cnewkirk7171 3 года назад

      Impeller shaft is broken. You can find the fix, as I just did, also on RUclips. Good luck.

    • @radekw708
      @radekw708 3 года назад

      @@cnewkirk7171 yep they sent me a new unit.. I tried brass shaft lasted 1 month. Ceramic 7.3cm shaft best way to go

  • @devilduck7977
    @devilduck7977 3 года назад +1

    Don’t purchase an inter spa they don’t work. I’ve tried everything to repair mine and it’s a total waste of time.

  • @FocusedontheRoad
    @FocusedontheRoad 5 лет назад

    Pulled both of the sensors.. still gave me the E90. 😩

    • @letzrepairit5492
      @letzrepairit5492  5 лет назад

      Try sending water through the inlet one at s time. Is the pump quite or making a grinding sound?

    • @FocusedontheRoad
      @FocusedontheRoad 5 лет назад

      Its silent.. I turn on the filter and it hesitates for about 10 seconds and then gives me the error code. I took off the filters and tried it, disassembled the pump and cleaned it all out.. it’s all super clean. I think I just need a new pump??

    • @FocusedontheRoad
      @FocusedontheRoad 5 лет назад +1

      I’ll try replacing the carbon rod with a brass rod... then maybe replace the pump assembly

    • @letzrepairit5492
      @letzrepairit5492  5 лет назад

      @@FocusedontheRoad let me know if i can help

  • @georgephilips3528
    @georgephilips3528 4 года назад

    Did not work

    • @georgephilips3528
      @georgephilips3528 4 года назад

      It was the pump! had an extra on hand from an old system. Swapped the pumps and it works now. only took 10 min.

  • @guichardnadine3951
    @guichardnadine3951 Год назад

    En français

  • @12jazon
    @12jazon 5 лет назад +1

    That's some dirty water...yuck!

  • @wadeey1
    @wadeey1 4 года назад +1

    Your definately not changing your filters after each use (as you recommend) cause that water was NASTY!!

  • @davidsnellen6853
    @davidsnellen6853 4 года назад

    Go figure. Mine does not have that sensor. There is no sensor in that location.

    • @tomcherry9757
      @tomcherry9757 3 года назад

      neither on mine. must be a different model, So the problem has to be with a bad impeller.