WIC Evaporator cleaning because of a water leak
YT308
0:00 Intro
0:08 Why Clean it?
0:33 Fan Cover Fasteners
1:00 Large Trash Can on a rolling cart
1:30 How to properly use a Backup Wrench
2:49 Some Pans swing down
3:04 Not this one though
3:39 The Drain Fitting Removed
3:56 Evaporator Washed, blades and covers removed
4:22 Washing the dirty blades
4:41 Washing the dirty covers
5:28 Trick for reinstalling the blue covers
6:53. Finished
Просмотров: 478

Видео

Programing Abnormalities E2 Controller
Просмотров 242Месяц назад
YT306
Fixing Randall's Frozen Food Section down
Просмотров 863Месяц назад
YT305
Deli Case Top Shelf Is Warm
Просмотров 676Месяц назад
YT304 Deli Case F6 Hussmann M5X-12EP B962-0848 Called out for the deli Case F6 the is stocked with Soups, reported as not cooling products on the top shelf. On arrival, I removed the Soups from the bottom shelf, and removed the 2 covers and bottom supports for the left evaporator of this 12' Case. I then found that the fan on the right side was not running, because the electrical plug for the m...
Reach In Freezer(RIF) In Supermarket Meat Dept Doesn't Freeze well
Просмотров 1,4 тыс.Месяц назад
YT303. On this service call, I break down from start to finish the entire call. From first walking up to it, to diagnosing the problem, I analyze how this small refrigerant circuit, having a charge that is unknown to be under or overcharged, reacts in real time to refrigerant adjustments to reveal that it was actually overcharged to begin with. I also discuss how to utilize the Traulsen IntelaT...
Wireless Module On The Wrong Case
Просмотров 2452 месяца назад
YT302 I received the work order for Self Contained Reach In Cooler 4 alarming for high temperature. I noticed that both of the sensors on Wireless Module #4 are reading 71 degrees-equivalent to room temperature. Because of this, I walked the store and located one reach in cooler that's labeled as S/C RI 7 by the manager's desk and pickup area unplugged, with a Wireless Module Mounted on the top...
Troubleshooting a Rooftop Condenser Unit with a Tripped Breaker and Fried Motor
Просмотров 7042 месяца назад
YT301 Called out for the Beer Aisle Front half on RTU 2 reported as not cooling. I found the RTU Not running. One of the 2 breakers for the condenser fan motors tripped. Upon resetting the breaker and pushing the manual HPS, a short popped off from one of the motors and tripped the breaker again. Found that Fan # 3 is fried completely. Windings totally burned. Unwired it, reset the breaker, and...
A Ridiculous CO2 Leak
Просмотров 1,1 тыс.2 месяца назад
YT300 This is such a preventable leak if the installers would've just done their Job right. We won't get paid for this one.
Troubleshooting A Short with Ohms
Просмотров 1,6 тыс.3 месяца назад
YT299 In this video, I wanted to learn more about motor winding resistance, using it to find a short circuit get caused a tripped breaker, and i veered off onto how multiple motors in parallel affected the ohms reading.
Filthy McNasty Coil Gets Deep Cleaned
Просмотров 1,2 тыс.3 месяца назад
YT298
Old, Crumbling Evaporator Coil gets washed
Просмотров 4043 месяца назад
YT 297 I returned tonight to wash the evaporator coil. I used hot water only and with very little pressure rinsed most of the mud that had formed on the coil off. This was because any more pressure would have destroyed the coil. The coil is very old and brittle, and actually, the coating of hard mud that covers the coil is holding it more together than the coil coil be without it. So now, the c...
Melted Wiring on E2 Controlling 3 Racks
Просмотров 8563 месяца назад
YT296 I returned today, after stopping by Grainger and picking up a 3 phase High Voltage Terminal Block, and informed the manager that I would be replacing the terminal block and to not be alarmed when the racks all go down for a short period. I then proceeded and had to trace the wiring back to the breaker panel to locate the breaker. Powered it off and quickly replaced the Terminal Block for ...
Bad Sensor Causes Frozen Evaporator Island Case
Просмотров 2,2 тыс.4 месяца назад
YT295 MODEL - FN-12 I recieved the work order for The Coffin case in front of the Service MeatCase, not holding temp. I found the Case frozen, and that the controller had not gone into a defrost in the last 2 days, which i found to be caused by a faulty discharge temperature sensor. I forced a manual defrost and removed the ice. I picked up a new danfoss sensor from another technician nearby, a...
Frozen Food Case Alarming High Temperature
Просмотров 3,3 тыс.4 месяца назад
YT294
Dangerous Mold in Duct System
Просмотров 7264 месяца назад
Dangerous Mold in Duct System
Emerson Wireless Module Swapout
Просмотров 2294 месяца назад
Emerson Wireless Module Swapout
Customers who don't want to pay! (The short Version)
Просмотров 5294 месяца назад
Customers who don't want to pay! (The short Version)
Channel Update!
Просмотров 5494 месяца назад
Channel Update!
Gas Station Walk In Cooler 72 Degrees!
Просмотров 2 тыс.4 месяца назад
Gas Station Walk In Cooler 72 Degrees!
Washing Condenser Checking Subcool/Superheat and Shocked my Pool
Просмотров 8954 месяца назад
Washing Condenser Checking Subcool/Superheat and Shocked my Pool
Removing 3D Compressor From Rack
Просмотров 1,2 тыс.4 месяца назад
Removing 3D Compressor From Rack
Replacing the Condenser Fans on the Frozen Food Rack
Просмотров 1,2 тыс.4 месяца назад
Replacing the Condenser Fans on the Frozen Food Rack
Supermarket Vacuum Drain System Repair
Просмотров 2 тыс.4 месяца назад
Supermarket Vacuum Drain System Repair
Organic Produce Case Stopped Working
Просмотров 6 тыс.4 месяца назад
Organic Produce Case Stopped Working
Solenoid Valve Rebuild
Просмотров 6374 месяца назад
Solenoid Valve Rebuild
460V Variable Speed Condenser Fan Failed
Просмотров 1,7 тыс.4 месяца назад
460V Variable Speed Condenser Fan Failed
What's Wrong With This Rack?
Просмотров 3,4 тыс.4 месяца назад
What's Wrong With This Rack?
Defrost Heater Replacement 5 Door Tyler Frozen Case
Просмотров 1,8 тыс.5 месяцев назад
Defrost Heater Replacement 5 Door Tyler Frozen Case
Frozen Food Rack Went Down
Просмотров 122 тыс.5 месяцев назад
Frozen Food Rack Went Down
Replacing An Embraco Compressor in a Kool-It Self Contained
Просмотров 3,1 тыс.5 месяцев назад
Replacing An Embraco Compressor in a Kool-It Self Contained

Комментарии

  • @colejc
    @colejc 4 дня назад

    appreciate the attention to details and the edits my brother! referenced this prior to my install tonight ill let you know how it goes!!!

  • @mannyknoxville247
    @mannyknoxville247 5 дней назад

    I really hate how they put the exhaust right under the transmission, I don’t know a thing about cars, but I noticed that right away in your video. It’s like they want our transmission to overheat

    • @HVACRServiceTech
      @HVACRServiceTech 4 дня назад

      Thats a really good point, and one I hadn't thought of. I think that the engineers and designers at GM, took this well into consideration, and surely also did some lab testing to get a full understanding of the effects of the exhaust temperature on the transmission fluid. There's probably actually no way that they overlooked it. With that being what likely happened, it probably helps warm up the transmission fluid during a cold start up, because, well if we relied on the torque converter and friction alone to heat the fluid, and also I guess the coolant tank of the radiator. These as well as the exhaust pipe, fresh out of the Cat, each affect the transmissions ability to regulate a certain temp. This exhaust pipe, also had to be tested for the reduction in size that it has there by the pan, and lab testing had to be done to make sure it was not too much of a restriction. As long as our transmissions remain full of fluid they will be ok. Cool observation tho!

  • @YANGNIMOG
    @YANGNIMOG 6 дней назад

    Great video.

  • @MakeItGreatAgain55
    @MakeItGreatAgain55 8 дней назад

    Do you have to reprogram the TEHCM if you unplug it after you remove it from the tranny for cleaning? Or can you unplug it, clean it and plug it back in to put it all back together, and take it for a test drive?

    • @HVACRServiceTech
      @HVACRServiceTech 8 дней назад

      @MakeItGreatAgain55 good question. It would seem to me, and I could be wrong, NO. The only time that the TEHCM would need to be reset to learn again, would be if new clutch packs were installed, or if anything in the Hydraulic Circuit was disrupted such as the oil pump area, pumping vanes, etc... If you are cleaning the TEHCM and also replacing the Pressure Switches, I would be more concerned that YES, it would be smart to probably reprogram it. But just to remove and clean it like during partial fluid change(drain the pan and replace the measured lost oil with new fluid), I would feel fine with just a reassemble and test drive.

    • @MakeItGreatAgain55
      @MakeItGreatAgain55 8 дней назад

      @HVACRServiceTech Thanks for the fast reply! I just did a filter change on a used GMC Denali XL with the 6L80. Check engine light said the 1 and 3 selonids are stuck open, causing shift problems. Simply changing the fluid with a new filter made a world of difference. It is very smooth shifting during the test drive, but now (3 days later), it read that all the selonoids are stuck open while driving the 10 miles into town. We pulled over and parked it for about two hours. When we went to pick it up, it started and drove perfectly and didn't need to trailer it home. Drove it today and it still seems fine but had a little hesitation going from 2 to 3rd. As a precaution, I'm going to change out the fluid and filter once more and clean the valve body and TEHCM as you did in the video before deciding if I need to do a complete rebuild on the tranny. Again, thanks for you time and great video, it helped me out!

    • @HVACRServiceTech
      @HVACRServiceTech 8 дней назад

      @MakeItGreatAgain55 no problem. Did you see my video on replacing the pressure switch films? I think that you should try to change them. I believe in the video that I uploaded, I included footage of me cleaning the actual switch contacts, under the Orange Films. If you haven't had any metal shavings appear on the magnet of the pan, I would wait a little bit before doing the overhaul and rebuild-unless you want to for the experience and it's worth it for you to. But if you're trying to avoid a rebuild, buy the kit off Amazon and change the 4 films, clean the contacts, when you do that cleaning. I'll find the right kit on Amazon and reply here with the link for you. And if the films are old anyways and still sealing, they're gonna fail soon anyways Better to change them now for many reason and the chance that it will fix your issue

    • @HVACRServiceTech
      @HVACRServiceTech 8 дней назад

      @@MakeItGreatAgain55 a.co/d/f5P6Kvx

    • @HVACRServiceTech
      @HVACRServiceTech 8 дней назад

      @@MakeItGreatAgain55 ruclips.net/video/xmoV38EVKgk/видео.htmlsi=EOnyow8kyn59dv_M

  • @billydead1342
    @billydead1342 10 дней назад

    The notorious electro fin coil what a nightmare. 4:58 that’s a vendor issue

  • @Curtis1984
    @Curtis1984 17 дней назад

    4L60E.. had a bad solenoid, replaced it.. removed the pan did the filter/gasket/seal maintenance.. I had no idea I needed to reset the adaptations until reading on many forums.. so I went on eBay and picked up this tool.. is there anything you need to do after the reset.. or only drive it..? Obviously I'll be taking it easy.

    • @Curtis1984
      @Curtis1984 17 дней назад

      Worked out great. I did find the option to reset the adaptations. Shifts so much better. We'll see if it stays that way. My original issue was WOT would shift really late, and under easy driving it would almost skip 3rd and go right into OD.. the person before me must have drive this thing slow all the time. I would've reset anyway after a fluid change, but especially after testing the lock up solenoid was way below recommended OHM reading I decided to replace the part. Only $20 part. I'm very happy with the Foxwell tool. Same one in this video. I would do this reset before having a shop mess with it.. but atleast change the fluid/filter/seal/gasket.. as it says in the tool procedure before reset.. you must have changed some components. Take care y'all.

  • @Syedbadusha143
    @Syedbadusha143 24 дня назад

    Supermarket refrigeration system eckelmann controller LDS software priority 1 password did you know?

  • @dustinthomlinson3859
    @dustinthomlinson3859 25 дней назад

    Looks like you did what i did to my exhaust! Screw those rusty bolts!

  • @aycaramba-1912
    @aycaramba-1912 28 дней назад

    wtf you want to loose mroe time to stay at work? calor is better for win time for charge. you are recovering but why make it slow? no way to do that for me

  • @boneal4342
    @boneal4342 Месяц назад

    Im comenting for help i have a 2007 yukon xl 4x4 and the transmission went out and i have a spare 2008 chevy Silverado 4x4 both 4l60e can i make a clean swap? Theres a few wiring issues noticble immediately will this matter. They are only on the transfer case side of things can i jist swap transfer cases from one to the other

    • @HVACRServiceTech
      @HVACRServiceTech 29 дней назад

      I worked on a 4l60 once, but I did much more in-depth research on the 6L80. You should educate yourself on the sticker code and how they apply to the GM family. And that info will help you better understand if this can work. Seems the chances are good that they will because of the close year range and the fact that they would not have a TEHCM.

  • @jesss5588
    @jesss5588 Месяц назад

    Just wanted to drop in and say HAPPY NEW YEAR! To one of my favorite creators! Love your content keep it coming!

  • @Jason-ys4ck
    @Jason-ys4ck Месяц назад

    ❤❤❤

  • @chesstime356
    @chesstime356 Месяц назад

    Nice work done

  • @Straight_White_Fatherly_Figure
    @Straight_White_Fatherly_Figure Месяц назад

    Mine has 4 wheel drive. Not sure how much more work it is

  • @czechmate6916
    @czechmate6916 Месяц назад

    Great job and video as always. Merry Christmas to you and your family. 💪💪🇺🇸🇺🇸

  • @jesss5588
    @jesss5588 Месяц назад

    When there’s product in the way? And you need to diagnose do you move it? I’m curious because I’m in the same line of work wondering how you handle that

    • @HVACRServiceTech
      @HVACRServiceTech Месяц назад

      @@jesss5588 I usually do move it because I just don't feel like waiting on them to move it so I end up moving it myself and it's faster. But that is only because I want to. It is their job and their responsibility to move it

  • @alejandrozometa1951
    @alejandrozometa1951 Месяц назад

    Yeah you would have to re assign board and points on that sheesh that’s a mess

  • @hiramgonzalez3316
    @hiramgonzalez3316 Месяц назад

    Good Job 👏🏾

  • @adamdnewman
    @adamdnewman Месяц назад

    Frozen ain't frozen ❄ ♥

  • @TimmyTurner5-l5z
    @TimmyTurner5-l5z Месяц назад

    WOW! Wonderful explanation. Great job and thank you. God bless you!!!!

  • @GunnerSentinel
    @GunnerSentinel Месяц назад

    Irritates me how long you spend feeling product in different cases, if you see 2 different circuits are warm go straight to the rack instead of wasting so much time. Check suction pressure then breakers then safeties. I know Albertsons/Randall’s will sell that product anyway but any other store would have to toss it so time is of the essence

    • @HVACRServiceTech
      @HVACRServiceTech Месяц назад

      @@GunnerSentinel does it now? Lol. That's just the way I would do it. You're irritated by literally about 90 seconds worth of time, so much so that you felt you needed to post a comment to let me know. It was a 55 min drive, and when I got the call, I didn't leave for about 20 mins. I made it within the required 2 hr time frame. The 90 seconds is worth my time. You can keep going it your way, it won't irritate me. But that's how i do it and will continue

  • @czechmate6916
    @czechmate6916 Месяц назад

    💪💪👍👍

  • @donny8212
    @donny8212 Месяц назад

    nice vid bro

  • @kyleholmbeck6052
    @kyleholmbeck6052 Месяц назад

    Love your videos man

  • @BLUE_COLLAR_REFER
    @BLUE_COLLAR_REFER Месяц назад

    Tip for those units. When you don’t have a sensor, you can use the discharge line sensor temporarily. All three sensors are the same.

    • @HVACRServiceTech
      @HVACRServiceTech Месяц назад

      @@BLUE_COLLAR_REFER oh yea absolutely. Just have to splice them in because the plugs are different good each one.

  • @SombraLocs
    @SombraLocs Месяц назад

    Refrigeration is a different beast. You have to have a lot of patience.

  • @I_Lucid_Dreamer
    @I_Lucid_Dreamer Месяц назад

    I’ve used metal strapping and screwed it down to the front of the case and the top of the evaporator fan shroud not a permanent fix but it helps until you get new ones

    • @HVACRServiceTech
      @HVACRServiceTech Месяц назад

      @I_Lucid_Dreamer aye. Yea that's the call you sent me last night. Oh hey. , I just heard back. I got the offer letter just now

  • @KenDeltano
    @KenDeltano Месяц назад

    Been doing this for 30 years am now retired, every time I open one of these Hussman impact cases, the useless plastic panels are cracked and broken. Why is everything made out of plastic?

    • @HVACRServiceTech
      @HVACRServiceTech Месяц назад

      @KenDeltano I'm sure there is a good reason, to make them out of plastic. But I don't know what that reason is. I work in the service department of Hussmann, so idk what goes on at the Manufacturing side of it. You know something crazy?... I have to order Hussmann parts from United Refrigeration. Lol.

  • @thesilentonevictor
    @thesilentonevictor Месяц назад

    Good MacGyver

  • @pedrojardim325
    @pedrojardim325 Месяц назад

    😅

  • @radicalgamingnerd986
    @radicalgamingnerd986 Месяц назад

    Gota love easy fixes. Man that store neglects that cooler. The worn out racks and trays. The mass amounts of rust water and snot looking substance at the bottom. It definitely wouldn’t hurt them to clean it every so often and show it some love.

  • @shaboomhabaaz8660
    @shaboomhabaaz8660 Месяц назад

    If you ever have a bad evaporator (EL) thermistor, on those older red InteliTrauls, and don't have one. You can unplug it and it'll do time INT time TERM defrost forever. The new blue ones will do that for 72 hours then lockout defrost until reset or you replace the probe

  • @stevengilber1153
    @stevengilber1153 Месяц назад

    Nice work!!! I agree with Nate Peterson, get a steamer it's much faster.

  • @natepeterson7145
    @natepeterson7145 Месяц назад

    I hope that's customer price on that sensor. Geeze I need to switch to commercial appliances.

    • @HVACRServiceTech
      @HVACRServiceTech Месяц назад

      That's just the price advertised by my supplier when looked up online by anyone. When logged in the price cuts by 50%

    • @brandoncorrea511
      @brandoncorrea511 Месяц назад

      @@HVACRServiceTechwhat app? I do resi not commercial…

    • @HVACRServiceTech
      @HVACRServiceTech Месяц назад

      @@brandoncorrea511 that is the United Refrigeration Website. Www.uri.com

  • @natepeterson7145
    @natepeterson7145 Месяц назад

    Use a steamer. Get the $99 Wagner automotive steamer. Takes 9 minutes to preheat.

    • @harbosonius
      @harbosonius Месяц назад

      Dude I swear by the steam gun for fridge /freezer evaps like this. Goes so much faster!! I learned it about ten years ago from an old timer and I never looked back. A hair dryer just pisses me off nowadays.😂😂😂😂

    • @maintenanceproreviews
      @maintenanceproreviews Месяц назад

      Totally agree you can get a bissel at Walmart for 39$ or Harbor Freight has a Bauer 39$ very portable.

    • @natepeterson7145
      @natepeterson7145 Месяц назад

      @@harbosonius I use the Wagner for sxs 's as a backup while using the Bissell and it cuts down on time. I had to cobble a Dc fan to clear all the steam so I can see. Especially if I can't get the evap fan to stay on in diagnostics mode.

  • @hb3537
    @hb3537 2 месяца назад

    Where do I get a copy of the manual? I work in Colorado and that's all they have at Costco

  • @HighVybeTribe
    @HighVybeTribe 2 месяца назад

    1st 💪

  • @juniorbucio1058
    @juniorbucio1058 2 месяца назад

    You were good at first but towards the end TRASHHHHH.

  • @PigeonTheory
    @PigeonTheory 2 месяца назад

    underpaid hvac tech crashes out attending grocery store outage

  • @Shawn_RHVAC
    @Shawn_RHVAC 2 месяца назад

    You should carry the EC5411E motor.

  • @dashcamandy2242
    @dashcamandy2242 2 месяца назад

    1:08 - Nelly's "Hot in Herre" playing while you're investigating a high temperature alarm... 🤣

  • @anactualpilot
    @anactualpilot 2 месяца назад

    yoooo brotha

  • @WswRefrigeration
    @WswRefrigeration 2 месяца назад

    MAGA

  • @refer_insight
    @refer_insight 2 месяца назад

    There’s no floor drains? Crazy

  • @davejohnsonnola1536
    @davejohnsonnola1536 2 месяца назад

    Beer man gotta make his quota too!

  • @I_Lucid_Dreamer
    @I_Lucid_Dreamer 2 месяца назад

    Hey, in case you didn’t know, that site has those check valves in place so if you ever have to isolate the cases you can do so safely without the risk of a rupture. The check valves are piped in parallel to the ball valve you allow the built up pressure to return to the system side without risking a blowout or rupture. Another site has special ball valves that look like they are just a ball valve but they have an internal check valve. Pretty neat stuff!

    • @natepeterson7145
      @natepeterson7145 2 месяца назад

      Why does co2 rupture when low side is closed? Don't work with co2 but have a certification to work on it and never seen this or heard of this.

    • @I_Lucid_Dreamer
      @I_Lucid_Dreamer 2 месяца назад

      @ the pressure build up in the case will rise because of the ambient temp. The type K copper will burst if the pressure is not released in time. The only instance we have had that i have heard of is a reach-in frozen food case that burst because the case was pumped down and isolated. This case was also divided from the adjacent cases and the case temp rose high enough to allow the trapped refrigerant to build up high enough to reach the burst point of the copper. The case temp most likely reached above 65 degree

  • @johnstrh1
    @johnstrh1 2 месяца назад

    Hey man, love the videos. I currently work on kitchen refer. How much more work is doing supermarket stuff? I wanna make the switch and stop working on prep tables and crap but I also wanna see my wife lol

    • @HVACRServiceTech
      @HVACRServiceTech 2 месяца назад

      @johnstrh1 it can be alot more at times. Depends on if you work for a major company or not. The big ones can be busy 24/7 so when you're on call it's brutal.

  • @czechmate6916
    @czechmate6916 2 месяца назад

    Another day saved 👍👍

  • @ValDominator
    @ValDominator 2 месяца назад

    i think you should go back to master technician mindset

    • @HVACRServiceTech
      @HVACRServiceTech 2 месяца назад

      @@ValDominator plz, do explain why you think that...

  • @czechmate6916
    @czechmate6916 2 месяца назад

    Now we’re getting into uncharted territory for me. I retired when this was starting to come into play. Maybe you can teach an old dog new tricks. Lol I will watch and learn from the experts thanks brother 💪💪🇺🇸🇨🇱🙏✝️