EASUN 8kw inverter - outputting even though it is off
Просмотров 8713 года назад
another attempt to troubleshoot the grid sync issues
EASUN SMW 8kw inverter - grid sync/ frequency issues
Просмотров 1 тыс.3 года назад
With only a neutral line connected, it detects the voltage on the input - which should not be the case. It senses its own output voltage.
EASUN iSolar SMW 8kW inverter - MPPT tracking not working properly
Просмотров 3,4 тыс.3 года назад
I had installed the EASUN iSolar SMW 8kW inverter recently and just testing it out. Besides the grid sync issue I posted in earlier video, this one shows another issue: MPPT tracking not working correctly, potentially causing lot of electricity losses due to not utilising the PV panels when the day is not fully bright. I hope EASUN resolves the issue over Firmware update.
EASUN iSolar SMV 8kW - frequency/grid issues
Просмотров 3,7 тыс.3 года назад
My brand new EASUN iSolar SMV 8kW inverter misbehaves while grid power is out. If the wiring is there, but grid is not actually connected, it drops the frequency to 40Hz on output and still detects the input - even though the grid is off. It starts "clicking" some relay, and chops the output power every couple of seconds. Like if some internal relay is not disconnected and it tries to sync with...
Tronxy X5SA-400 reboot problem
Просмотров 1,5 тыс.4 года назад
I have purhcased a new Tronxy X5Sa-400 coreXY printer from Aliexpress seller, and printer looks great prints great - when it prints. Most of the files it doesn't want to print at all, as ti reboots as soon as it comes to printing position. Smaller models do print, however. Problem was reported to Tronxy and at the moment I am awaiting for their response (reported today, 31.10.2020). Edit: Link ...
HNK Radnički Mece - Baranja Belje prednatjecatelji 31.10
Просмотров 3884 года назад
HNK Radnički Mece - Baranja Belje prednatjecatelji 31.10 - 1 : 0 0:00 Zagrijavanja 1:58 Početak utakmice 6:32 Goool - Mece 1:0 19:50 Kraj prvog poluvremena 23:59 Početak drugog poluvremena 44:16 Kraj utakmice

Комментарии

  • @marcossanchez336
    @marcossanchez336 6 месяцев назад

    With an Easun 4.2 Kw I have the same problem, I have solved it practically, with a 20 - 30A relay -> low intensity coil, a resistance of 2 - 10Kohms (depending on the relay consumption) and a 1N4007 protection diode. Every morning when the sun rises and the voltage rises from 150-160 Vdc the relay closes (the relay is connected directly to the solar PV voltage and up to 250 Vdc a resistance of 10-15 Watts is Ok), and allows voltage to arrive. to the inverter of the solar panels, at night when the voltage drops the relay opens and the input of the solar panels remains at 0V. With this you forget about the issue, because every time the relay closes and the instantaneous voltage reaches the inverter, the MPPT is positioned correctly and no longer fails throughout the day.

  • @antoniocasarotti4172
    @antoniocasarotti4172 Год назад

    Molto interessante sapere questo, visto che lo appena acquistato. Spero che abbiano risolto il problema aggiornando il firmware, controllerò. Grazie

    • @IgyBoyCRO
      @IgyBoyCRO Год назад

      Let us know if your inverter works as it should, or it has the same issue. From couple other purchases that were done by my friends, it seems they still suffer from the same issue - unless something changes in the last month-two.

  • @k.delectronics3966
    @k.delectronics3966 Год назад

    Did you try to cut also the newtral when you cut the phase?

    • @IgyBoyCRO
      @IgyBoyCRO Год назад

      Yes, once you do that - it works properly. :) So, for full offgrid it would be OK.

    • @NoiseSHome
      @NoiseSHome Год назад

      @@IgyBoyCROyou need a 2P or 1P+N breaker on grid input, this is “normal”. Well, “Easun normal” 😂😂😂

  • @gdab0107
    @gdab0107 2 года назад

    I also had the same issue with some Easun inverters, also many other persons complaint about this, is easy, this is a software bug and they don't have the expertise to fix it. Don't buy Easun/powland, it's crap. no support and you're stuck with your faulty inverter. Money back? forget it !!!

  • @gdab0107
    @gdab0107 2 года назад

    dont buy easun/powland, its crap, copied hardware with crap software, mppt issues, etc.... most of them have this problem as IgyBoyCRO is saying ... no support, no return of money

  • @justmeme942
    @justmeme942 2 года назад

    I have 2 firmwares from easun. 91.04 and 92.14, i update the 91.04 but the mppt let the voltage up only when have minimum 2A. What firmware do u have from easun?

    • @marcossanchez336
      @marcossanchez336 6 месяцев назад

      Where do you download the firmware? Thanks.

  • @rOSScOGITANS
    @rOSScOGITANS 2 года назад

    hi, just a question, the 500Volt pv maximum array input is for each mppt channel (500 + 500) or is for the whole inverter? is not clear in user manual because i see an example (in the manual) of 12+12 panels with 37v VOC, almost 450Volts for each imput!

    • @IgyBoyCRO
      @IgyBoyCRO 2 года назад

      Hi, each input is for its own. So, each can handle 500V.

  • @allanstrand638
    @allanstrand638 2 года назад

    Hi, is this fixed, firmware?

  • @allanstrand638
    @allanstrand638 2 года назад

    Hi, is this fixed ?

    • @IgyBoyCRO
      @IgyBoyCRO 2 года назад

      Haven't got time to play with it. There is obviously some firmware being released by Voltronic that fixed "some" of the flaws on the inverter but I don't know which ones. Winter is coming so I might give it a try in a month-two

  • @otdel330
    @otdel330 2 года назад

    Hello do you have some experience with the wifi monitoring app for that inverter?

    • @IgyBoyCRO
      @IgyBoyCRO 2 года назад

      Hi, yes and no. I have installed it and use it here and there to adjust parameters on inverter.

  • @denski5642
    @denski5642 2 года назад

    Could you please share with us your grid or D.U. input, is it L & N or L1 & L2?i mean is it LINE TO LINE or LINE TO NUETRAL?

  • @bengrimmett1239
    @bengrimmett1239 2 года назад

    Same problem here, tracking gets stuck at 90v until you cycle the breaker then it'll continue tracking. We have a high voltage string here, 470voc so it isn't related to your lower voltage string.

    • @IgyBoyCRO
      @IgyBoyCRO 2 года назад

      Tnx for sharing. Yes, it was confirmed with Chinese that the algorithm used here is the same one use in low voltage versions - which means it is not optimized for the wider range voltage and can easily "loose" the MP point. :/

    • @bengrimmett1239
      @bengrimmett1239 2 года назад

      ​ @IgyBoyCRO Easun finally emailed me the new firmware updated called 'mppt optimisation update'. Not sure I can post links here.

    • @IgyBoyCRO
      @IgyBoyCRO 2 года назад

      @@bengrimmett1239 Would be excellent if you have link to it. I believe you can post it without issues. There are more than few people reporting the same issue. I can (possibly)update the description in video to post the link to it.

    • @bengrimmett1239
      @bengrimmett1239 2 года назад

      @@IgyBoyCRO looks like youtube has removed the link, or its possibly pending approval from you

    • @IgyBoyCRO
      @IgyBoyCRO 2 года назад

      @@bengrimmett1239 Hi Ben, have you had any luck with the new firmware? Try uploading it to gdrive and send the link to that. Maybe the hosting site is blacklisted by RUclips, not allowing the link...

  • @radoslavtasky8805
    @radoslavtasky8805 2 года назад

    First few things to do: - Remove any RCD on input if any - joint null and ground of input and output too. - Do not connect any photovoltaic pannels with possible leaking currents - Disconnect monitoring - Ensure that battery management is not powered from battery nor via switched power supply, ensure galvanic insulation. - Disconnect whole house appliances - Connect just something with galvanic insulation (transformer) - Try it

    • @IgyBoyCRO
      @IgyBoyCRO 2 года назад

      Hi! Tnx for the reply, but all those have already been tried and none works. I have spent hours on troubleshooting the thing. What is more important - I believed that only my unit has this issue, so I foolishly went on and purchased couple more units for my clients and guess what - all of them had the same or similar issues. So, my advice - stay away from this inverter. 5.5kw versions had none of those issues and work perfectly fine. If I simply drop in a 5.5kW inverter on the place of this one - it works without a blink.

    • @radoslavtasky8805
      @radoslavtasky8805 2 года назад

      @@IgyBoyCRO I have two units, friend of mine too and there are no troubles like you described.

    • @IgyBoyCRO
      @IgyBoyCRO 2 года назад

      @@radoslavtasky8805 What can I say. You are lucky then. :)

  • @justmeme942
    @justmeme942 2 года назад

    how u solve the problem? works after update?

    • @IgyBoyCRO
      @IgyBoyCRO 2 года назад

      Unfortunately, no. I just gave up on having this inverter connected to grid. I just use it in full off-grid mode. It still has same MPP problem, can't be properly turned off, but Easun was unable to provide solution to any of my problems so far.

    • @uweuksik5323
      @uweuksik5323 2 года назад

      @IgyBoyCRO What version firmware you have? I have a plan to buy this inverter but in case of MPPT issue it's preferred not to buy this one.

  • @justmeme942
    @justmeme942 2 года назад

    Have u solved the issue ?

    • @IgyBoyCRO
      @IgyBoyCRO 2 года назад

      Haven't got time to play with it. There is obviously some firmware being released by Voltronic that fixed "some" of the flaws on the inverter but I don't know which ones. Winter is coming so I might give it a try in a month-two.

  • @nakataharizanov
    @nakataharizanov 2 года назад

    Hello ! Like you, I have such an inverter. I have a request to you to check if it is the same with you. When I measure with a multimeter between the plus or minus cable that comes from the panels and ground, I have a voltage of 220V. I checked with a test lamp (ice) and it lights up. It looks abnormal to me. I dare not hang on a large load so as not to damage the inverter.Thanks in advance!

    • @IgyBoyCRO
      @IgyBoyCRO 2 года назад

      Hi, the voltage of the panels is not related to the ground, so it "floats" in relation to the ground and is not a problem. You can safely go and use it like that.

    • @nakataharizanov
      @nakataharizanov 2 года назад

      I think this is some kind of leak from the inverter itself. It is not normal for cables with DC to have and AC power. Therefore, if you have the opportunity, please check if it is the same with you.

  • @joedim3296
    @joedim3296 2 года назад

    Hi I have a question the install to the inverter is it in series from grid to house. meaning the grid wiring from meter come straight into the inverter and the output of the inverter goes to the house power. And I think your video issue when you kill the live only your still partially connected to the grid by the neutral Correct me if I'm wrong

    • @IgyBoyCRO
      @IgyBoyCRO 2 года назад

      Negative wire being connected to the grid should not be an issue. If it doesn't have the live wire, it can't sync with the grid. The issue here is that, obviously the inverter can't work if the input neutral and output neutral are on the same line - which works perfectly with other inverters and is definitely a flaw either by design, or somewhere in the firmware.

    • @kostaskostopoulos2913
      @kostaskostopoulos2913 2 года назад

      @@IgyBoyCRO Hello, I asked EaSun about this issue and they told me that the N input and N output cannot be connected together. Did you try another connection?

  • @MrSolunac
    @MrSolunac 2 года назад

    why you didnt ask to sent you firmware update?

    • @IgyBoyCRO
      @IgyBoyCRO 2 года назад

      It doesn't go like that with Chinese. First they stall you and bomb you with requests to do this and that and video record everything, send logs and data and whatnot only to stop responding. Somewhere in between I have requested that they deliver a new firmware, and I mentioned it a couple of times, but they just ignored it. The reason might be that they don't have a fix for this yet - which would explain why they needed the logs and data from the inverter. Other reasons: they just don't care and stall you untill you give up on pinging them.

    • @MrSolunac
      @MrSolunac 2 года назад

      alo drugar odakle si ti ?

    • @IgyBoyCRO
      @IgyBoyCRO 2 года назад

      @@MrSolunac Pozdrav. Hrvatska, Baranja. Ti?

    • @MrSolunac
      @MrSolunac 2 года назад

      am distributer of EASUN samo mi kazista ti treba i sta se desava ,nema problerma

    • @IgyBoyCRO
      @IgyBoyCRO 2 года назад

      @@MrSolunac Što je žalosno: i ja sam im bio distributer - do ovog i još dva druga slučaja kada nisu htjeli pružiti podršku za dva invertera. Prodao sam na desetke 5kW i 5.5kW njihovih (EASUN,Powland) invertera i onda zapnem na tri reklamacije. Strašno. Dok ide, ide...Kad zapne, nema pomoći od njih.

  • @rOSScOGITANS
    @rOSScOGITANS 2 года назад

    hi! do you think i will have problem using it off-grid? i will connect 14kw lifepo4 battery (16 280a cells)

    • @IgyBoyCRO
      @IgyBoyCRO 2 года назад

      Hi, while it is offgrid it works OK. The only issue to be aware of is the one with MPPT not working properly on cloudy and semi-cloudy days. As for the reliability - so far it is OK. In this half a year I use it it was powering all sorts of loads: 2x 4kW air conditions for heating (15hrs a day), charging a car regularly, workshop tools, compressors,drills, water pump, and sensitive electronics - 3D printers, servers etc...everything in a house without glitch.

  • @kostaskostopoulos2913
    @kostaskostopoulos2913 3 года назад

    Hello, did you find out why you have all these issues with this inverter?

    • @IgyBoyCRO
      @IgyBoyCRO 3 года назад

      Unfortunately, no. EAsun has not been able to resolve the issue, and they are now not responding for more than a month. They asked for all sorts of videos and data, but none helped. I guess the board is faulty, or the firmware is doing something wrong. Anyhow, I am managing to use it to power the house - without grid connection(the other inverter I showed is doing the battery charging from grid). MPP tracking sucks, as the algorithm is badly implemented, and needs an firmware update, but I am not sure if I will get it from EAsun. The power off and power on is not bothering me at this point, but is just adding to frustrations over the inverter. Best part is: I have sold dozens of EAsun inverters(5.5kW versions) and their customer still ignores me. Now imagine if you only buy one single inverter. Getting the help from them in that case is close to impossible, as they will simply ignore you.

    • @kostaskostopoulos2913
      @kostaskostopoulos2913 3 года назад

      @@IgyBoyCRO thank you for your kind reply. So, you think you've got a faulty device?

    • @IgyBoyCRO
      @IgyBoyCRO 3 года назад

      @@kostaskostopoulos2913 I do not know. It could be a design flaw, or firmware error. Part of the issues are definitely due to the firmware bug(MPP tracking issue), other part of the issues could be both: faulty board or bad firmware. Unfortunately, I do not have high hopes that EASun is competent in resolving the issue, so I will probably need to disassemble it myself and check the board and possibly do reverse engineering of firmware to find the solution. But this is not ideal, and will cost a lot of time to do.

    • @kostaskostopoulos2913
      @kostaskostopoulos2913 3 года назад

      @@IgyBoyCRO I hope you will find the solution. I have ordered the same for a friend. I hope to receive it within next days. If you think I could help you, by coping the soft, if possible, or what else, please, just ask. 😀

    • @IgyBoyCRO
      @IgyBoyCRO 3 года назад

      @@kostaskostopoulos2913 thank you for the offer. I hope yours works properly. I will be dealing with mine probably in a month, as I am busy with other stuff at the moment, and I still hope Easun will reply(naive, I know). :) Good luck!

  • @kostaskostopoulos2913
    @kostaskostopoulos2913 3 года назад

    Hello, I did not understood, how did you resolve the issue later? Just with the breaker on/off?

    • @IgyBoyCRO
      @IgyBoyCRO 3 года назад

      Yes. Fully disconnect the PV array is what works every time - you just need to remember to do it. If you are not at home...no luck, you will just loose that electricity. :/ Other inverters (even other, cheap solar inverters from China) are on occasions "probing" the array for MPP point in a way that it will drift up and down with voltage significantly, to see if it is still on proper MPP, and this will happen every once in a while. It is just how most of MPP algorithms work. This one seems to not have this functionality implemented or is simply badly implemented.

    • @rOSScOGITANS
      @rOSScOGITANS 2 года назад

      @@IgyBoyCRO i bought exactly the same inverter yesterday... f... Did you contact the assistance for that problem? is it available a firmware update?

    • @IgyBoyCRO
      @IgyBoyCRO 2 года назад

      @@rOSScOGITANS Yes, but after I reported it they requested that I upload/send them the data from the logs for at least couple of days when that was happening so they could troubleshoot it. But once I sent it, they stopped responding. :/

    • @rOSScOGITANS
      @rOSScOGITANS 2 года назад

      @@IgyBoyCRO i have deleted the order for sure, anyway it's a very rare model, no found other users of this inverter, no reports in some forum, nada de nada!

    • @IgyBoyCRO
      @IgyBoyCRO 2 года назад

      @@rOSScOGITANS It is fairly new model, so it might be that the later versions will come with all those issues fixed already, and I totally understand that this happens (at this price range it can't be perfect), but what annoys the most is not getting ANY support over the matter. So I can't recommend them really.

  • @bogdansergiul
    @bogdansergiul 3 года назад

    you should try adding more panells for this inverter close to max Voc-20%

    • @IgyBoyCRO
      @IgyBoyCRO 3 года назад

      I could try doing it, but that is not a solution. I do not want my array arranged like that due to specific arrangement of panels. Part of panels is in the shade for a part of the morning and afternoon, and if I put them in a single string, I do not get the max power from panels, as those couple of panels in shade bring down the production of the whole array. Also, proper MPP tracking algorithm should work regardless of the amount of connected panels. The proof is the fact that it works perfectly once you force it to "rethink" the MPP strategy by disconnecting the array. Also, I have previously had the 5kW version of their inverter, with same configuration for solar charger (90-450V) and it worked flawlessly for years.

  • @joflo308
    @joflo308 3 года назад

    Hello , i plan to buy one of these , how did you manage the issue? Thx

    • @IgyBoyCRO
      @IgyBoyCRO 3 года назад

      Well, turns out the inverter is total cr*ap. MPPT is also not working properly, sometimes it hangs for hours at 90V, while it should be near 200V (which is the nominal voltage for my array). I have a separate video showing this. While my other inverter produces 1kw of power this one just sits at 90V and wastes energy. Reported the problem and EASun asked to provide the data. After I already sent a video and offered to send the logs, I received no response on that topic. On semi-cloudy days this means a waste of couple hundred watt-hours if not kWh.On the grid-sync issue, EAsun has proven to not be worth the hustle. They provided no solution for the problem, and still require all sort of videos to demonstrate the fault. What is even worse, the inverter - even when powered down, provides power to the loads. I'll put the links to that video later. It is not publicly listed, and I have not edited videos for public showing, but now Im thinking of doing some lengthy video, counting and showing all the issues. So, if you were to ask me is it worth to invest into EAsun inverter at this point, the answer is NO! Invest some money and buy from MPP solar or other non-chinese inverter.

    • @IgyBoyCRO
      @IgyBoyCRO 3 года назад

      Outputing even when turned off: ruclips.net/video/PlJ1EwA9oNQ/видео.html

    • @IgyBoyCRO
      @IgyBoyCRO 3 года назад

      Issue with MPPT: ruclips.net/video/WmmWFuhn6cc/видео.html

    • @joflo308
      @joflo308 2 года назад

      Thx , i bought an iGrid 5.6 SV4 while i missed your answer … but thanks for feedback

    • @NoiseSHome
      @NoiseSHome Год назад

      @@IgyBoyCROthere is a hacked firmware available to solve the 90V problem. Easun is a cheap clone chinese thing, don’t expect much…

  • @Ianpheitmans
    @Ianpheitmans 3 года назад

    I found your video while searching for information about this inverter. This is an interesting problem but as the wiring look a bit messy to me (sorry) I can't really get a hold on how this is connected. At around 3:28 in your video you try to explain how the neutral is connected and that confuses me. So let me get this straight, you connected the OUTPUT neutral line to the INPUT neutral line via the busbar which, for the sake of this experiment you put a switch in between? Shouldn't the input (both neutral and fase) be strictly separated from the output circuitry?

    • @IgyBoyCRO
      @IgyBoyCRO 3 года назад

      Hi, yes, I do have to agree on the wiring. :) Althought, it is because the old inverter (also EASUN 5kW version )has just been removed and the new one was connected when the issue was discovered. Yes, the input AC neutral wire is directly coupled with AC out neutral wire. Most inverters work properly in this configuration - as it should be. The issue is not simple, however, and depends on how your house electrical installation is designed, and specifically I refer to the neutral-ground binding(check how different systems work by having a look at TN-S, TN-C, TN-C-S, TT and other grounding methods). Also, the EASUN itself(Voltronic, Axpert) recommend it to be connected this way. I could probably bypass the issue I am having here by doing the modification of the house electrical installation, but that is not an option. This has to work like this. Take a look at the MPP Solar inverter on it's side - it works like that for years. Even the previous 5kW inverter from EASUN worked in this configuration without issues for years. I had installed many of those inverters and this is the first one having this kind of an issue. EASUN engeneer is on this but can't seem to find what the issue might be. Already removed the SCR (parallel) board as part of the diagnosing process, disconnected all the loads etc, but nothing helps so far. If all fails, I will have to consider re-wiring the house installation, but that is really the last option, since the inverter itself should work in this configuration without issues.

    • @Basti2804
      @Basti2804 Год назад

      You have by this model no neutral!!! Nehme den output neutral vom input ab!!! Dann funktioniert es!! Die neutralleiter dürfen sich NICHT BERÜHREN BEIDE!!

  • @wr2956
    @wr2956 3 года назад

    Hi! I’m reasearching these all in one boxes, planning my own little self sufficient system. They look great! These things need programming through the setting menu screen. I think you need the instructions manual, you seriously need to go through the menu to set the output to 240v and set the wavelength to 50hz, I think that then should solve your problem. I hope this works for you

    • @IgyBoyCRO
      @IgyBoyCRO 3 года назад

      Hi, thank you for the suggestion, but the output is already set to 230V and 50Hz output, but as you can see from the video, has some issues when input AC is connected to grid, and the grid then goes off(simulated by disconnecting the live wire, but neutral remains connected.

  • @qdesign3d
    @qdesign3d 3 года назад

    is this Gcode setting can be use on X5SA-400 PRO ?

  • @tizonferrol
    @tizonferrol 3 года назад

    Hi, i have the same problem using tronxy software. Now i'm using Cura software with the same parameters. I don't the picture on the small screen but now my printer works. Be carefull with the retraction speed, i'm using 40 mm/s and the same speeds.

  • @ItalianNerdGamer
    @ItalianNerdGamer 3 года назад

    It happen only with those files, print something else and it will work

    • @IgyBoyCRO
      @IgyBoyCRO 3 года назад

      Well, the fact is, it will work if you pick the slicing settings in certain way. However, do not rely on it doing so with out-of-the-box firmware settings. It will sometimes work properly, while in other cases it will simply stop printing at random stages of print and go into a reset. I have updated the description of the video with instructions on how to resolve the issue.

  • @panda79
    @panda79 4 года назад

    3d model gcode have problem,change one gcode try

  • @TimHawkins2015
    @TimHawkins2015 4 года назад

    I have the same problem, tronxy just told me to reformat the we card. I'm investigating replacing the firmware with marlin, becuase the tronxy firmware seems to be junk. I have a new x5sa-400 too.

    • @IgyBoyCRO
      @IgyBoyCRO 4 года назад

      Hi Tim, I haven't updated the situation after this video, but the issue was really resolved with the information provided by Tronxy support. Namely they suggested the same thing that you mention (format the SD card), plus some additional things. To quote the email I received: 1. Format the SD card, and then print the test model to try. 2. Re-refresh the configuration file. Pls check and update below firmware, load these file into sd card, use machine print the gcode file below to finish update, then re-start the machine. 3. Use other slicing software, and do not center the model when placing it. After formatting the card the things started getting better, and the advice to not center the object on the bed did seem to work as well. But the configuration file they supplied helped most, as after uploading it to the printer it never did go into reboot again(I can send you the configuration it they haven't supplied it to you already). All in all, I am quite pleased with how it works now and have printed more than a couple kg PLA, TPU and PetG filaments so far. Retraction is a bit tricky to adjust to work perfectly as the bowden tube is really long, but it is tolerable. I hope you will get yours to work fine and enjoy the prints as well.

    • @baudouinnouvel8249
      @baudouinnouvel8249 4 года назад

      @@IgyBoyCRO thanks a lot ! i have the same issue.

    • @IgyBoyCRO
      @IgyBoyCRO 4 года назад

      Hi@@baudouinnouvel8249, nice to hear this helped resolve the issue for you!

    • @BKFingerstyle
      @BKFingerstyle 4 года назад

      @@IgyBoyCRO hi bro ! I also have a new x5sa-400 too. And i have the same problem. So great to hear this help of you. Can you send the configration ??? . Thank you very much !!! My email : kbtbatiep@gmail.com

    • @IgyBoyCRO
      @IgyBoyCRO 4 года назад

      @@BKFingerstyle Please check the description on the video. I have updated it with the link to configuration. Happy printing!