Expansion valve type hard shut off this is not a bad expansion valve. This is not a plugged
Просмотров 658 часов назад
This is a normal operation of what is called a hard shut off expansion valve Stop selling customers expansion valves because some one told you if it does not bleed over from the high side to the low side that means it’s plugged Not all the time Somewhere designed to operate like this 
AC COMPRESSOR CUTOUT, finding minimum RPM for the amount of heat load input by the sun. ☀️
Просмотров 14813 часов назад
Experimenting with compressor RPM maintaining the longest runtime. The whole idea is not to have the clutch kick out.. Looking for steady pressures that do not cycle . 
HUGE REFRIGERANT LEAK STOPS 🛑 DURING ADDING REFRIGERANT. 100% gone after a few minutes of running
Просмотров 6442 часа назад
This type of leak that shuts itself off, and it only leaks precisely at exact temperature or pressure later on. Eventually, it will leak and dump the refrigerant . It might be one day one week one month In a very few cases because I personally knew a few customers had this type of refrigerant leak actually last through the year . You never know But the one thing you do know, it will leak again 
A/C CUSTOMER DOES NO MAINTENANCE. Paid to fix after brakes $$$ (“ that’s expensive”)
Просмотров 5242 часа назад
When customers literally destroy their own car by lack of maintenance. 🧑‍🔧 That end up with extremely high repair bills. And then the customer says when it’s time to repair the extremely expensive engine or transmission or replace a compressor that they destroy by not maintaining they complain about the price 🤦‍♂️ 
AC hose manufacturing repair on a car. Audi $600 hose.. or repair for $213.
Просмотров 6064 часа назад
Replacing damage hose from a collision on a car while the hose fittings are still attached to the car never removed 
Heat pump system on 2023 Hyundai ionic 6 . When  it breaks, it’s coming to your shop.
Просмотров 8274 часа назад
There are so many components to break malfunction or have intermittent glitches. Are you guys ready to repair these?🤣
1/4” HIGH FLOW VACUUM FITTINGS Low restriction, high speed
Просмотров 2614 часа назад
VACUUM NEED FOR SPEED
Ferrari Shop having a problem diagnosing poor cooling. compressor kicking out high protection
Просмотров 3587 часов назад
This is a pattern of the condenser fan, not operating 
AC blend doors sticking partially open heater control valve sticking open blend doors foam crumbling
Просмотров 2177 часов назад
When one of these old Mercedes have been sitting for many years and you start up the blower little pieces of foam shoot out of the vents that are for ceiling the blend doors This will cause unwanted core air to bleed by or outside air Doors partially not fully closed or open will not allow your evaporator blend doors to fully open or close On this model when the heater core control valve leaks ...
Mercedes AMG needs a compressor a few other components that’s a easy five grand of evaporated 
Просмотров 1177 часов назад
Quick recovery on an AMG with a failed compressor 
CHARGING REFRIGERANT BY HIGH SIDE PRESSURE? Out of calibration fluid fan clutch bad readings.
Просмотров 3687 часов назад
All these guys out there who are taught to look at high side pressure to determine if the AC system is OK. But they’re doing this on a car that several years old with some miles in the fluid thermal and clutch no longer works the way it did when it was brand new So now the high side pressure easily goes up really high fast . When it should not So your diagnosis is wrong Your charging method is ...
12. Refrigerant mineral oil never been touched are the easiest to draw deep vacuum 
Просмотров 3229 часов назад
Mineral oil does not absorb moisture as much as PAG or POE oil 
Under 500 µm vacuum in three minutes vacuum decay two 534 microns 1988 Mercedes 
Просмотров 37614 часов назад
Under 500 µm vacuum in three minutes vacuum decay two 534 microns 1988 Mercedes 
AC RECHARGE 1988 Benz stored since 2016. Only 25 psi visual inspection.
Просмотров 24914 часов назад
AC RECHARGE 1988 Benz stored since 2016. Only 25 psi visual inspection.
Air conditioning new compressor 1969 Mercedes.
Просмотров 18516 часов назад
Air conditioning new compressor 1969 Mercedes.
AC 1989 Mercedes 17,000 miles on it. Somebody else retrofitted, high moisture contamination.
Просмотров 40216 часов назад
AC 1989 Mercedes 17,000 miles on it. Somebody else retrofitted, high moisture contamination.
UV Breast light easy to gained this front shaft seal leak
Просмотров 23216 часов назад
UV Breast light easy to gained this front shaft seal leak
AC system damaged by HIGH MOISTURE content.  rust flakes clog the expansion valve.
Просмотров 1,2 тыс.21 час назад
AC system damaged by HIGH MOISTURE content.  rust flakes clog the expansion valve.
Harbor freight little toy, vacuum pump.
Просмотров 45121 час назад
Harbor freight little toy, vacuum pump.
IR Camera infrared thermometer, false cold temperature reading 
Просмотров 23621 час назад
IR Camera infrared thermometer, false cold temperature reading 
WERE DID THE REFRIGERANT OIL GO ???🤔 Compressor failure.
Просмотров 1,2 тыс.День назад
WERE DID THE REFRIGERANT OIL GO ???🤔 Compressor failure.
How to add AC evaporators to old car with limited space. Electric compressor.
Просмотров 487День назад
How to add AC evaporators to old car with limited space. Electric compressor.
AC HYBRID COMPRESSOR HAS A CLUTCH & ELECTRIC MOTOR uses POE oil not PAG oil
Просмотров 236День назад
AC HYBRID COMPRESSOR HAS A CLUTCH & ELECTRIC MOTOR uses POE oil not PAG oil
12 CFM vacuum pump how fast can I get to 1000 µm or less compared to 2 CFM 
Просмотров 368День назад
12 CFM vacuum pump how fast can I get to 1000 µm or less compared to 2 CFM 
WHEN YOU OVER FILL A REFRIGERANT RECOVERY TANK
Просмотров 361День назад
WHEN YOU OVER FILL A REFRIGERANT RECOVERY TANK
NEW Welsh Vacuum Pump  filling fresh vacuum pump oil first time
Просмотров 183День назад
NEW Welsh Vacuum Pump  filling fresh vacuum pump oil first time
HARBOR FRIGHT 2 CFM VACUUM PUMP VS 12 CFM VACUUM PUMP comparison
Просмотров 459День назад
HARBOR FRIGHT 2 CFM VACUUM PUMP VS 12 CFM VACUUM PUMP comparison
Two CFM Harbor freight, vacuum pump, testing performance micron range
Просмотров 391День назад
Two CFM Harbor freight, vacuum pump, testing performance micron range
Testing a little harbor freight to CFM battery powered pump. A little on the slow side. 
Просмотров 278День назад
Testing a little harbor freight to CFM battery powered pump. A little on the slow side.